connected to an external fan as the power supply of the external
fan and also can be used as electronically parallel connection with
another S1 or M1 humidifier.
4. Setting
There are three rubber keys for setting on the control unit. The
humidifier is factory set at 70%RH and can be adjusted by user to
any value from 60%RH to 80%RH. Key ‘▲’ is to increase the
humidity setting value. Key ‘▼’ is to decrease humidity setting
value. The displayed humidity value is equal to the humidity value
measured by the built-in sensor plus a calibration value. The built-in
fan will run to blow the moist airflow to the humidor when the
displayed humidity value is lower than setting value. The fan will
stop when the displayed humidity value is equal or higher than
setting value. Key ‘C’ is for calibration. You may adjust calibration
value to get more accurate value if you are sure another hygrometer
on your hand is more accurate. The factory setting calibration value
is zero. Click key ‘C’ and you will see the calibration value
displayed from LED, within 3 seconds, press Key ‘▲’ or ‘▼’ to
increase or decrease the calibration value within a range of -5.0 to
+5.0. For example, if the displayed humidity value from the
humidifier is 2%RH higher than the humidity value measured by a
high accurate hygrometer, you may set calibration value as -2.0 ,
and then the displayed humidity value on the humidifier will equal
to the measured humidity value plus the calibration value -2.0. The
setting values will not be lost even power off.
5. Alarms
There are two alarms for built-in fan error and lack of water. LED
will display ‘ ’ and buzzer will alarm to indicate ‘Fan error’ in
case of fan failure. LED will display ‘ ’ and buzzer will alarm to
indicate ‘Lack of water’ in case the measured humidity value is
10%RH at least lower than humidity setting value for two hours
that mostly be caused by lack of water. Alarm ‘Lack of water’ could
be happened in case the size of your humidor or cigar cabinet
exceeds the capability of the humidifier or the humidor/cigar cabinet
is not sealed well.
6. Location
You may put the humidifier in a humidor or a cigar cabinet after the
humidifier has been installed and set to regulate the desire humidity
level. Make sure the air paths of the humidifier has not been blocked.
It is recommended the humidifier to be placed with the LED up
toward. Keep at least 2 inch (50mm) clearance from the side air
outlet of humidifier to cigars or wall of a humidor and 0.2 inch
(5mm) clearance from the top air inlet to the lid. For a cabinet
application, it is recommended that the humidifier to be placed on
the centre position of the top layer, and if there are more humidifiers,
the second humidifier to be placed on the centre position of the
middle layer.
7. Warranty
Smart-lion Technology Co., Ltd. warrants goods of its
manufacture as being free of defective materials and faulty
workmanship. If the warranted goods are returned to
Smart-lion company during the warranty period of one year
after purchasing date. We will repair or replace the electronic
parts without charge those items it finds defective. The
warranty only applies to original purchaser at retailed and may
not be transferred.