Remove the complete xture from the packaging. If the canister and
luminaire are to be installed separately detach the luminaire from the
canister and place it back in the packaging and store securely.
If not discard the packing in an environmentally friendly way.
Dig a hole 20cm (8”) diameter and 30cm (12”). Place drainage material
in the bottom of the hole to drain away water and stop water level
build up. (See Fig. 1).
Sit mounting canister into the hole. Make sure that the top of the
canister is ush and level with the nished oor or ground level
(see Fig. 2).
Draw the power supply cable up through the centre of the canister
ready for connection to the luminaire.
Place blue ange protector into the top of the canister and press rmly
into place. This will protect the bronze or stainless steel ange as well
as stopping debris lling the canister. If grout is to be used with tiles
etc. then remove the ange protector before grouting is started.
NOTE: Do not backfill with stones, scoria or any material that will
leave air gaps next to the canister.
Concrete is strongly recommended to backfill the canister hole.
Concrete will conduct away 40% more heat than soil.
Fig. 2
Fig. 1
For Direct bury. Make a waterproof connection with the Input and
dimming cables. (See Fig.3a)
Place the luminaire into the hole. Make sure the ange is ush with the
ground level and then back ll around the luminaire. Compact the
surrounding substrate to ensure good heat conductivity. Place
drainage material in the bottom of the hole to drain away water and
stop water level build up.(see Fig. 2a).
Fig. 2a