HYDRACOOLING M100 Series User manual

M100 SERIES - INSTALLATION AND OPERATION MANUAL - V0
EN - Translation from the original manual

2
HYDRACOOLING LDA
Parque Industrial de Guimarães
1ª Fase, Pavilhão G15
4805-661 Guimarães, Portugal
Telephone: (351) 253 470 340
Email: mail@hydracooling.pt
Website: www.hydracooling.pt

3
Symbols
For your own protection you must use gloves and safety shoes.
Equipment performance can be compromised.
Damage may include persons.
Flammable.

4
General warnings
The instructions set in this manual should be read before using
the appliance.
Make sure that this manual it’s always available and on site.
The appliance must be handled only by qualified technicians.
Maintenance operations must be performed by qualified and au-
thorized technicians.
All data, information and instructions are conformant to the ap-
plicable legal regulations and standards.
The manufacturer declines all responsability regarding bad use of
the appliance, non compliance with local regulations and stand-
ards, handling by non qualified and non authorized technicians,
and non authorized replacements.
All appliances are class 3 (25°C/60%HR) tested.
If the environment exceed class 3 conditions, a deminuiting per-
formance should be expected.
Always check the marking plate.
At the end of production HYDRACOOLING products are carefully
inspected. No damaged units are sent out.
The appliance must be perfectly leveled.
The appliance must be located in an indoor environment.
The appliance must be connected to a grounded outlet.
Do not connect the appliance to a multiple block of outlets.
If the power cord gets damaged contact the manufacturer.
Do not storage explosive substances such as aerossol cans.

5
Always respect the loading lines.
Keep condenser area always free of obstacles.
The appliance has automatic defrost.
Do not use alternate means of defrosting besides the ones men-
tioned by the manufacturer.
Do not use electrical apparatus inside the refrigerated compart-
ment other than ones authorized by the manufacturer.
All maintenance actions must be done with the appliance fully
disconnected.
Check regularly for dirt in the condenser.
For proper end of life of the appliance go to the approppriate
local center.
All complaints must mention model and serial number.
To fully disconnect the appliance, power cable must be pulled out.
This manual can be found at www.hydracooling.pt.
General warnings
Refrigeration system charged with flammable refrigerant.
Make sure that personnel are aware that the appliance contains
a flammable refrigerant.
Maintenance operations must be performed by qualified techni-
cians to handle flammable refrigerants.
Keep clear of obstruction all ventilation openings in the appliance
enclosure or in the structure for building-in.
Do not damage the refrigerant circuit.

6
Symbols 3
General warnings 4
1. Guarantee, standards and regulations 8
1.1. Guarantee 8
1.2. EU declaration 9
2. Technical data 10
2.1. Model description 10
3. Installation 19
3.1. Unpacking 19
3.2. Packaging contents 20
3.3. Damage verification 20
3.4. Location 21
3.5. Joining/Assemblies 22
3.6. Electrical connections 37
3.7. Remote systems 37
4. Operation 40
4.1. Safety marks 40
4.1.1. Safety marks for appliances with flammable refrigerant 41
4.2. Control panel and features 43
4.3. Loading 47
4.4. Temperature regulation 48
4.5. Defrost 48
4.6. Electronic controller 48
5. Cleaning and maintenance 53
5.1. Exterior cleaning 53
5.2. Interior cleaning 53
5.3. Lights replacement 54
5.4. Shelf removal 55
5.5. Panels and grille removal 56
5.6. Sliding condensing unit 57
5.7. Condenser cleaning 58
5.8. Evaporator cleaning 58
5.9. Sewage 62
5.10. Evap pan cleanning 63
5.11. Model display conversion 63
6. Troubleshooting 64
7. Service 66
8. End of life 67
9. Notes 68
Annexes 69
INDEX

7
This page has been left blank intentionally.

8
1. Guarantee, standards and regulations
1.1. Guarantee
Guarantee doesn’t cover defects originated during unpacking.
Guarantee doesn’t cover malfunction due to poor installation or incorrect operation of
the appliance.
Guarantee doesn’t cover acts of negligence.
Guarantee doesn’t cover inproper electrical connections.
Guarantee doesn’t cover models with defaced marking plate.
Guarantee doesn’t cover glass breaking.
Guarantee doesn’t cover defects on appliances with non original parts.
Guarantee doesn’t cover waste of food due to malfunction.
Guarantee doesn’t cover defects due to maintenance or cleaning operations period fail-
ures stated in this manual.
Guarantee doesn’t cover appliance handling by non authorized and non qualified technician.
Guarantee doesn’t cover defects due to grid electrical fluctuations.
All complaints must be done accompanied by the model and serial number.
The guarantee it’s in accordance with all relevant standards and regulations, between
the parties involved (seller and buyer). The period to file a complaint about a defect or
contract failure is 12 months.

9
EU Declaration of Conformity
We,
Manufacturer HYDRACOOLING, Lda
Address Parque Industrial de Guimarães 1ª Fase, Pavilhão G15,
4805-661 Guimarães
Country Portugal
Phone number +351 253 470 340
Fax number +351 253 470 349
Declares that the DoC is issued under our responsibility for the following
product:
Product/model M100 Series
Type Horizontal display cabinet open and closed to serve
over, with storage and condensing unit
The object of the declaration described above is in accordance with relevant
harmonized legislation of the Union:
Machinery Directive (MD) 2006/42/EU
Low Voltage Directive (LVD) 2014/35/EU
Electromagnetic compatibility (EMC) Directive 2014/30/EU
Restricted substances directive (Rohs) 2011/65/EU
Directive on waste electrical and electronic equipment (WEEE) 2012/19/EU
The following harmonized standards and technical specifications have been
applied:
Title Date of the standard/specification
EN 60335-1 2012/A11:2014
EN 60335-2-89 2010+A1:2012
EN 61000-3-2 2006 + A1:2009 + A2:2009
EN 61000-3-3 2008
EN 55014-1 2006 + A1:2009 + A2:2011
EN 55014-2 1997 + A1:2001 + A2:2008
EN 378-1 2008/A2:2012
EN 378-2 2008/A2:2012
EN 12100 2010
Place and date
of issue: Guimarães, 2018-05-01
Eduardo Oliveira
CEO
1.2. EU Declaration

10
M100-VD
2. Technical data
2.1. Model description
The models M100SS/M100VC/M100VD part of M100 series are refrigerated display cab-
inets, IHC2/IHC8 tipology. The M100 series ventilated cooling system provides balance
and maintenance of temperature for the operating range of 0°C and 2°C, ideal for any
type of packaged food items and beverages. Designed for holding and maintaining tem-
perature only, this appliance will ideally operate under Class 3 (25°C/60%RH) conditions.
All models have LED lighting.

11
M100-SS

12
M100-VC

13
M100-VD

14
M100SS Model
230/50
1525x881x1100
1525x881x1592
1,37
262
1,17
160
0/4
815
R452A
2140
R290
3
1267
7,09
64
0,40
230/50
1970x881x1100
1970x881x1592
1,79
343
1,53
160
0/4
815
R452A
2140
R290
3
1267
7,09
64
0,40
230/50
2570x881x1100
2570x881x1592
2,36
452
2,02
160
0/4
1025
R452A
2140
R290
3
1508
8,31
96
0,60
Spec
150
200
250
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R R RN N NSC
SC
SC
| | || | || |
SC - Self contained
R- Remote
N- Neutral
Voltage (V)/Frequency (Hz)
Dimensions (LxHxD)(mm)
Service dimens (LxHxD)(mm)
TDA (m2)
Net Volume (l)
Refrigerated shelf area (m2)
Load limit (kg/m2)
Operating temperature (°C)
Cooling capacity (W)(-10°C)
Refrigerant
Amount (g)
GWP
Refrigerant
Amount (g)
GWP
P (W)
I (A)
Noise (db)
Weight (kg)
DEC (kWh/24h)
SEC (kWh/24h/m2)

15
M100VC Model
Spec
230/50
1525x1201x1100
1525x1201x1947
0,97
262
1,17
160
0/4
815
R452A
2140
R290
3
1303
7,19
100
0,50
230/50
1970x1201x1100
1970x1201x1947
1,27
343
1,53
160
0/4
815
R452A
2140
R290
3
1327
7,24
124
0,55
230/50
2570x1201x1100
2570x1201x1947
1,67
452
2,02
160
0/4
1025
R452A
2140
R290
3
1574
8,49
162
0,77
150
200
250
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R R RN N NSC
SC
SC
| | || | || |
SC - Self contained
R- Remote
N- Neutral
Voltage (V)/Frequency (Hz)
Dimensions (LxHxD)(mm)
Service dimens (LxHxD)(mm)
TDA (m2)
Net Volume (l)
Refrigerated shelf area (m2)
Load limit (kg/m2)
Operating temperature (°C)
Cooling capacity (W)(-10°C)
Refrigerant
Amount (g)
GWP
Refrigerant
Amount (g)
GWP
P (W)
I (A)
Noise (db)
Weight (kg)
DEC (kWh/24h)
SEC (kWh/24h/m2)

16
815
R452A
2140
R290
3
1303
7,19
100
0,50
230/50
1525x1201x1100
1525x1201x2094
0,97
262
1,17
160
0/4
230/50
1970x1201x1100
1970x1201x2094
1,27
343
1,53
160
0/4
815
R452A
2140
R290
3
1327
7,24
124
0,55
230/50
2570x1201x1100
2570x1201x2094
1,67
452
2,02
160
0/4
1025
R452A
2140
R290
3
1574
8,49
162
0,77
150
200
250
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M100VD Model
Spec R R RN N NSC
SC
SC
| | || | || |
SC - Self contained
R- Remote
N- Neutral
Voltage (V)/Frequency (Hz)
Dimensions (LxHxD)(mm)
Service dimens (LxHxD)(mm)
TDA (m2)
Net Volume (l)
Refrigerated shelf area (m2)
Load limit (kg/m2)
Operating temperature (°C)
Cooling capacity (W)(-10°C)
Refrigerant
Amount (g)
GWP
Refrigerant
Amount (g)
GWP
P (W)
I (A)
Noise (db)
Weight (kg)
DEC (kWh/24h)
SEC (kWh/24h/m2)

17
Marking plate

18
Fgas plate

19
11
33
22
44
3. Installation
3.1. Unpacking

20
3.2. Packaging contents
The package received with your M100 series model includes the items arranged in the
table below.
Item Model
Installation and Operating Manual M100 SS/VC/VD
EU Declaration M100 SS/VC/VD
Electrical diagram M100 SS/VC/VD
Exhibition M100 VC/VD
Accessories M100 SS/VC/VD
Luminaires M100 VC/VD
Fish tray M100 VC/VD
3.3. Damage verification
After rigorous inspection, all units leave HYDRACOOLING without any damage or defect.
HYDRACOOLING shall not be liable for any defect occurred at the time of transportation
or unpacking.
In order to complain to the carrier, possible damage, must be checked in the following
points:
- Doors
- Outdoor panels
- Shelves
- Glasses
- Painting
- Knobs
- Structure
- Base
This manual suits for next models
3
Table of contents