• 2-Speed 1/3 Horsepower Motor
- 2.9 Amps on HIGH Speed
- 1.8 Amps on LOW Speed
• High Performance w/ Low Amp Draw
• Directional Airow
SPECIFICATIONS:
Power: 115 VAC, 60 HZ
Drive Motor: 1/3 Horsepower, 3-Speed
Weight: 25 Pounds
Cord: 25 feet
Outlet: Integral GFCI Duplex Power Outlet
HIGH 1100 1150 2.9
LOW 930 975 1.8
Speed RPM CFM AMPS
fHorizontal k45° Angle h90° Angle
The 2-speed OmniDry 2.9 Amp Air Mover delivers an outstanding 3480 FPM at 2.9 amps, is
stackable, features two daisy-chain GFCI outlets, a 25’ power cord, and a built-in cord wrap.
Weighing in at only 25 pounds, this capable air mover packs a punch.
Hydro-Force Manufacturing • www.hydroforce.com • 800-637-37891
TABLE OF CONTENTS
Introduction ...........................1
Specications ........................... 1
General Safety Warnings ................ 2
Operating Instructions..................2
Troubleshooting .......................3
Warranty...............................4
Warrantor ............................... 4
Warranties .............................. 4
User Responsibility ...................... 4
Freight.................................. 4
Limitations and Exclusions............... 4
Legal Rights............................. 4
USER INFORMATION
Serial No. _____________________________
Purchase Date _________________________
Dealer’s Name__________________________
OMNIDRY 2.9 AMP AIR MOVER

• NOT intended for outdoor use.
• Do not operate the unit with a cut or frayed power
cord
• Do not unplug the unit by pulling on the cord. Grasp
the plug rmly and pull it out of the wall socket or
power receptacle.
• Always use a grounded outlet.
• Never operate electrical equipment in standing
water.
• Never operate with safety grills removed. Personal
Injury may result!
• Do not stick ngers or other objects through the
safety grills.
• Never restrict airow to the unit. This may cause it to
overheat.
• Never service or clean this unit while it is plugged in.
• Never sit or stand on the unit or use as a shelf.
• Ensure that children do not have access to the
equipment. Do not allow children to play with or
near the equipment, or in its airow.
• To reduce risk of re or electric shock, do not use this
air mover with any solid-state speed control device.
• Do not leave device plugged in when not in use.
• Store this equipment indoors; do not expose to
harsh weather.
• Use only as described in this manual.
• Use only Manufacturer’s recommended attachments.
• Do not pull or carry by the cord, use the cord as a han-
dle, close doors on the cord, or pull the cord around
sharp edges.
• Do not run over cord.
• Keep cord and housing away from heated surfaces.
GENERAL SAFETY WARNINGS
OPERATING INSTRUCTIONS
1. Check the machine for any obstructions in the
fan or airow areas before plugging in the unit or
operation of the unit.
2. Adjust the machine to desired position for
operation by pulling it back to its preset angle
adjustments.
3. Plug the power cord into a GFCI outlet. Do not use
an extension cord in conjunction with the standard
power cord.
4. Push the TEST button on the GFCI Duplex power
outlet. FCI should trip.
• If GFCI trips, push the RESET button to reset
GFCI and proceed with set-up
• If GFCI does not trip, the GFCI Duplex power
outlet should be replaced
5. Plug additional air movers into the GFCI Duplex
Power Outlet as needed. (Amp draw of OmniDry
air mover and the additional air movers or other
accessories plugged in the GFCI Duplex Power
Outlet must not exceed 12 amps.)
6. The OmniDry 2.9 air mover has two power settings.
Press the button to HIGH or LOW, depending on the
desired speed.
CAUTION
• Do not handle plug with wet hands.
• Turn the unit o before unplugging.
• Do not use when you are tired, distracted or under the
inuence of drugs, alcohol or medication.
When using any electrical equipment, basic
precautions should always be followed, including
the following:
Hydro-Force Manufacturing • www.hydroforce.com • 800-637-37892

TROUBLESHOOTING
Symptom Problem Solution
Unit will not turn on Not plugged in Plug machine in 120V outlet
No power from outlet Reset GFCI or move to new outlet
Switch is worn Replace Switch
Tripped circuit breaker Reset Breaker
Tripped GFCI Reset GFCI
Damaged power cord Repair or Replace Power Cord
Capacitor on motor is bad Replace motor
Motor is bad Replace motor
Air mover will not operate on all
speeds Switch is worn Replace switch
Capacitor on motor is bad Replace motor
No power from GFCI Duplex Power
Outlet Tripped GFCI Reset GFCI
Wire loose Repair wiring to outlet
Outlet is worn Replace outlet
GFCI trips when air mover is
plugged in Cord is worn or damaged Repair or Replace Power Cord
Switch is bad Replace switch
Air mover is wet Allow air mover to dry & retest
GFCI is bad Replace outlet
GFCI trips when air mover is
turned on Cord is worn or damaged Repair or Replace Power Cord
Switch is bad Replace switch
Motor is bad Replace motor
Air mover is wet Allow air mover to dry & retest
The fan is rubbing Fan has moved on motor Reset fan & tighten set screw
Motor mount is loose Tighten motor mount
Motor mount is broken Replace Motor
Motor shaft bent Replace Motor
Fan is damaged Replace fan
Air mover is making strange noises Foreign object in fan Turn o motor & remove object
Fan is rubbing See above topic
Fan is damaged Replace fan
Motor bearing is worn Replace motor
Hydro-Force Manufacturing • www.hydroforce.com • 800-637-37893

WARRANTOR:
HYDRO-FORCE, INC.
4282 SOUTH 590 WEST
SALT LAKE CITY, UT 84123
Toll Free: (800) 637-3789
USER RESPONSIBILITIES:
Warranty service must be performed by a service
provider authorized by Hydro-Force. To obtain war-
ranty service, you must rst acquire a Return Material
Authorization (RMA). To get an RMA you must present
proof of purchase (or lease), by the use of a warranty
card, original sales receipt, or other reasonable and
reliable means.
To obtain an RMA, call Hydro-Force at (800) 637-3789
and ask for the Customer Service Department, which
will then issue an RMA number and will arrange for
repair or replacement, at our option.
WARRANTIES:
This warranty covers the Hydro-Force Centrifugal Air
Mover.
One Year - 100% parts and labor
(all components).
Five Years
- Only materials and workmanship
of the housing are covered.
If defect in materials or workmanship occurs within
the warranty period, Hydro-Force will repair or replace
the defective unit or part.
FREIGHT:
Freight to and from the service provider is the respon-
sibility of the end user. The end user is responsible for
normal care and proper return packaging.
LIMITATIONS AND EXCLUSIONS:
This warranty does not cover any defect, malfunction,
etc. resulting from misuse, abuse, lack of normal care,
corrosion, freezing, tampering, accident, modication,
unauthorized or improper repair or installation, acts
of nature, or any cause beyond the reasonable control
of their distributor or of Hydro-Force, Inc.
If any Hydro-Force Centrifugal Air Mover part is re-
paired or replaced, the new part shall be warranted
for the balance of the original warranty (but all war-
ranty periods will be extended by the period of time,
if any, that the Hydro-Force Air Mover is out of service
while awaiting covered warranty
service).
Warranty service will be performed during
normal working hours.
UPON THE EXPIRATION OF THE WRITTEN WARRANTY
APPLICABLE TO THE HYDRO-FORCE AIR MOVER OR
ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED
BY LAW INCLUDING MERCHANTABILITY AND FIT-
NESS FOR PARTICULAR PURPOSE, SHALL ALSO EX-
PIRE ALL WARRANTIES MADE BY HYDRO-FORCE ARE
SET FORTH HEREIN, AND NO CLAIM MAY BE MADE
AGAINST HYDRO-FORCE BASED ON ANY ORAL WAR-
RANTY. IN NO EVENT SHALL HYDRO-FORCE, INC., IN
CONNECTION WITH THE SALE, INSTALLATION, USE,
REPAIR, OR REPLACEMENT OF ANY HYDRO-FORCE
AIR MOVER OR PART THEREOF BE LIABLE UNDER ANY
LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CON-
SEQUENTIAL DAMAGES INCLUDING, WITHOUT LIMI-
TATION, WATER PRECAUTIONS AGAINST SAME), LOST
PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY
REAL OR PERSONAL PROPERTY.
Some states do not allow limitations on how long and
implied warranty lasts, and some do not allow the
exclusion or limitation of incidental or consequential
damages, so one or both of these limitations may not
apply to you.
LEGAL RIGHTS:
This warranty gives you specic legal rights, and you
may also have other rights which vary from state to
state.
WARRANTY
Hydro-Force Manufacturing • www.hydroforce.com • 800-637-37894
This manual suits for next models
2
Table of contents