• Installaon and service must be performed by a qualified installer (for example, a
licensed plumber or gas fier), otherwise the warranty will be void.
• The installer (licensed professional) is responsible for the correct installaon of
the micro-boiler and for compliance with all naonal, state/provincial, and local
codes.
• The manufacturer does not recommend installing the micro-boiler in a pit or
locaon where gas and water can accumulate.
• Do not have the vent terminal poinng toward any operang window, door, or
opening into a building.
• Do not install the micro-boiler next to any source of airborne debris, such as a
clothes dryer and a vent that can cause debris to be trapped inside the combuson
chamber, unless the system is direct-vented.
• The manufacturer does not recommend installing the micro-boiler in an ac due
tosafety issues. If you install the micro-boiler in an ac:
• Make sure the micro-boiler will have enough combuson air and proper
venlaon.
• Keep the area around the micro-boiler clean. When dust collects on the flame
sensor, the micro-boiler will shut down on an error code.
• Place the micro-boiler in a locaon that provides easy access for service and
maintenance.
• A drain pan, or other means of protecon against water damage, is required to
be installed under the micro-boiler in case of leaks.
• It is recommended to direct vent the heater.
WARNING
• Damage caused by water quality is not covered by the warranty.
• Only potable water or potable water / glycol mixtures can be used with this
micro-boiler. Do not introduce pool or spa water, or any chemically treated
water into the micro-boiler.
• Water hardness levels must not exceed 7 grains per gallon (120 ppm) for single
family domesc applicaons or more than 4 grains per gallon (70 ppm) for
all other types of applicaons. Water hardness leads to scale formaon and
may affect / damage the micro-boiler. Hard water scaling must be avoided or
controlled by proper water treatment.
• Water pH levels must be between 6.5 and 8.5
• Well water must be treated.
• Do not install the micro-boiler where water, debris, or flammable vapors may get
into the flue terminal.
• Although the micro-boiler is designed to operate with minimal sound, the
manufacturer does not recommend installing the micro-boiler on a wall adjacent
toa bedroom, or a room that is intended for quiet study or meditaon, etc.
• Locate your boiler close to a drain where water leakage will not do damage to
surrounding areas. As with any fluid heang appliance, the potenal for leakage
at some me in the life of the product does exist. The manufacturer will not be
responsible for any water damage that may occur. If you install a drain pan under the
micro-boiler, ensure that it will not restrict the combuson air flow .