8
Enertech Global WT Models, Rev.: B
Consumer Instructions: Dealer should
instruct the consumer in proper operation,
maintenance, lter replacements, thermostat
and indicator lights. Also provide the consumer
with the manufacturer’s Owner's Manual for the
equipment being installed.
Enertech Global D-I-Y Policy: Enertech Global’s
geothermal heat pumps and system installations
may include electrical, refrigerant and/or water
connections. Federal, state and local codes
and regulations apply to various aspects of the
installation. Improperly installed equipment can
lead to equipment failure and health/safety
concerns. For these reasons, only qualied
technicians should install a Enertech Global built
geothermal system.
Because of the importance of proper
installation, Enertech Global does not sell
equipment direct to homeowners. Internet
websites and HVAC outlets may allow for
purchases directly by homeowners and do-
it-yourselfers, but Enertech Global offers no
warranty on equipment that is purchased via
the internet or installed by persons without
proper training.
Enertech Global has set forth this policy
to ensure installations of Enertech Global
geothermal systems are done safely and
properly. The use of well-trained, qualied
technicians helps ensure that your system
provides many years of comfort and savings.
Equipment Installation: Special care should
be taken in locating the unit. All units should
be placed on a formed plastic air pad, or
a high density, closed cell polystyrene pad
slightly larger than the base of the unit. All units
should be located in an indoor area were
the ambient temperature will remain above
55°F and should be located in a way that
piping and ductwork or other permanently
installed xtures do not have to be removed for
servicing and lter replacement.
Electrical: All wiring, line and low voltage,
should comply with the manufacturer's
recommendations, The National Electrical
Code, and all local codes and ordinances.
Thermostat: Thermostats should be installed
approximately 54 inches off the oor on an
inside wall in the return air pattern and where
they are not in direct sunlight at anytime.
Loop Pumping Modules: Must be wired to the
heat pump’s electric control box. A special
entrance knockout is provided below the
thermostat entrance knockout. A pump
module connection block, connected to
the master contactor, and circuit breaker is
provided to connect the Pump Module wiring.
Desuperheater Package: Water heating is
standard on all residential units (units may be
ordered without). It uses excess heat during
both heating and cooling cycles, to provide
hot water for domestic needs. A double wall
desuperheater exchanger (coil) located
between the compressor and the reversing
valve, extracts superheated vapor to heat
domestic water; still satisfying its heating and
cooling needs. The water circulation pump
comes pre-mounted in all residential units, but
must be electrically connected to the master
contactor. Leaving it disconnected ensures that
the pump will not run without a water supply.
The Desuperheater package can make up to
60% (depending on heat pump usage) of most
domestic water needs, but a water heater is still
recommended.
Desuperheater Piping: All copper tubes
& ttings should be 5/8” O.D (1/2” nom)
minimum with a maximum of 50ft separation.
Piping should be insulated with 3/8” wall
closed cell insulation.
Note: Copper is the only approved material
for piping the desuperheater.
Section 3: Installation Considerations