I-Tech IT-M7700 Series User manual

Programmable AC Power
Source
IT-M7700 Series User Manual
Model: IT-M7700 Series
Version: V1.9/4,2023

Notices
© Itech Electronic, Co.,
Ltd. 2023
No part of this manual
may be reproduced in any
form or by any means (in-
cluding electronic storage
and retrieval or translation
into a foreign language)
without prior permission
and written consent from
Itech Electronic, Co., Ltd.
as governed by interna-
tional copyright laws.
Manual Part Number
Trademarks
Pentium is U.S. registered
trademarks of Intel
Corporation.
Microsoft, Visual Studio,
Windows and MS Win-
dows are registered
trademarks of Microsoft
Corporation in the United
States and/or other coun-
tries and regions.
Warranty
The materials contained in this docu-
ment are provided “as is”, and is sub-
ject to change, without prior notice, in
future editions. Further, to the maxi-
mum extent permitted by applicable
laws, ITECH disclaims all warrants, ei-
ther express or implied, with regard to
this manual and any information con-
tained herein, including but not limited
to the implied warranties of merchant-
ability and fitness for a particular pur-
pose. ITECH shall not be held liable
for errors or for incidental or indirect
damages in connection with the fur-
nishing, use or application of this
document or of any information con-
tained herein. Should ITECH and the
user enter into a separate written
agreement with warranty terms cover-
ing the materials in this document that
conflict with these terms, the warranty
terms in the separate agreement shall
prevail.
Technology Licenses
The hardware and/or software de-
scribed herein are furnished under a li-
cense and may be used or copied only
in accordance with the terms of such
license.
Restricted Rights Legend
Restricted permissions of the U.S.
government. Permissions for software
and technical data which are author-
ized to the U.S. Government only in-
clude those for custom provision to
end users. ITECH follows FAR 12.211
(technical data), 12.212 (computer
software). DFARS 252.227-7015
(technical data–commercial products)
and DFARS 227.7202-3 (permissions
for commercial computer software or
computer software documents) while
providing the customized business li-
censes of software and technical data.
Safety Notices
A CAUTION sign denotes
a hazard. It calls attention
to an operating procedure
or practice that, if not cor-
rectly performed or ad-
hered to, could result in
damage to the product or
loss of important data. Do
not proceed beyond a
CAUTION sign until the in-
dicated conditions are
fully understood and met.
A WARNING sign denotes
a hazard. It calls attention
to an operating procedure
or practice that, if not cor-
rectly performed or ad-
hered to, could result in
personal injury or death.
Do not proceed beyond a
WARNING sign until the
indicated conditions are
fully understood and met.
A NOTE sign denotes im-
portant hint. It calls atten-
tion to tips or
supplementary informa-
tion that is essential for
users to refer to.

Copyright © Itech Electronic Co., Ltd. I
IT-M7700 Series User Manual
Quality Certification and Assurance
We certify that series instrument meets all the published specifications at time
of shipment from the factory.
Warranty
ITECH warrants that the product will be free from defects in material and work-
manship under normal use for a period of one (1) year from the date of delivery
(except those described in the Limitation of Warranty below).
For warranty service or repair, the product must be returned to a service center
designated by ITECH.
•The product returned to ITECH for warranty service must be shipped PRE-
PAID. And ITECH will pay for return of the product to customer.
•If the product is returned to ITECH for warranty service from overseas, all
the freights, duties and other taxes shall be on the account of customer.
Limitation of Warranty
This Warranty will be rendered invalid in case of the following:
•Damage caused by circuit installed by customer or using customer own
products or accessories;
•Modified or repaired by customer without authorization;
•Damage caused by circuit installed by customer or not operating our prod-
ucts under designated environment;
•The product model or serial number is altered, deleted, removed or made il-
legible by customer;
•Damaged as a result of accidents, including but not limited to lightning, mois-
ture, fire, improper use or negligence.

Copyright © Itech Electronic Co., Ltd. II
IT-M7700 Series User Manual
Safety Symbols
Direct current ON ( power)
Alternating
current
OFF ( power)
Both direct and
alternating
current
Power-on state
Chassis (earth
ground) symbol.
Power-off state
Earth ( ground)
terminal
Reference
terminal
Caution Positive terminal
Warning ( refer to
this manual for
specific Warning
or Caution
information)
Negative terminal
A chassis
terminal
- -
Safety Precautions
The following safety precautions must be observed during all phases of opera-
tion of this instrument. Failure to comply with these precautions or specific warn-
ings elsewhere in this manual will constitute a default under safety standards of
design, manufacture and intended use of the instrument. ITECH assumes no li-
ability for the customer’s failure to comply with these precautions.

Copyright © Itech Electronic Co., Ltd. III
IT-M7700 Series User Manual
•Do not use the instrument if it is damaged. Before operation, check
the casing to see whether it cracks. Do not operate the instrument
in the presence of inflammable gasses, vapors or dusts.
•The instrument is provided with a power cord during delivery and
should be connected to a socket with a protective earth terminal, a
junction box or a three-phase distribution box. Before operation, be
sure that the instrument is well grounded.
•Please always use the provided cable to connect the instrument.
•Check all marks on the instrument before connecting the instru-
ment to power supply.
•Ensure the voltage fluctuation of mains supply is less than 10% of
the working voltage range in order to reduce risks of fire and elec-
tric shock.
•Do not install alternative parts on the instrument or perform any un-
authorized modification.
•Do not use the instrument if the detachable cover is removed or
loosen.
•To prevent the possibility of accidental injuries, be sure to use the
power adapter supplied by the manufacturer only.
•We do not accept responsibility for any direct or indirect financial
damage or loss of profit that might occur when using the
instrument.
•This instrument is used for industrial purposes, do not apply this
product to IT power supply system.
•Never use the instrument with a life-support system or any other
equipment subject to safety requirements.

Copyright © Itech Electronic Co., Ltd. IV
IT-M7700 Series User Manual
•SHOCK HAZARD Ground the Instrument. This product is provided
with a protective earth terminal. To minimize shock hazard, the in-
strument must be connected to the AC mains through a grounded
power cable, with the ground wire firmly connected to an electrical
ground (safety ground) at the power outlet or distribution box. Any
interruption of the protective (grounding) conductor or disconnec-
tion of the protective earth terminal will cause a potential shock
hazard that could result in injury or death.
•Before applying power, verify that all safety precautions are taken.
All connections must be made with the instrument turned off, and
must be performed by qualified personnel who are aware of the
hazards involved. Improper actions can cause fatal injury as well as
equipment damage.
•SHOCK HAZARD, LETHAL VOLTAGES This product can output the
dangerous voltage that can cause personal injury, and the operator
must always be protected from electric shock. Ensure that the out-
put electrodes are either insulated or covered using the safety cov-
ers provided, so that no accidental contact with lethal voltages can
occur.
•Never touch cables or connections immediately after turning off the
instrument. Verify that there is no dangerous voltage on the electro-
des or sense terminals before touching them.
•After using the device, turn off the power switch of the device be-
fore unplugging the power cord or disassembling the terminals. Do
not touch the cable or the terminal immediately. Depending on the
model, the dangerous voltage at the plug or terminal is maintained
for 10 seconds after the device is switched off. Make sure that there
is no dangerous voltage before touching them.
•Failure to use the instrument as directed by the manufacturer may
render its protective features void.
•Always clean the casing with a dry cloth. Do not clean the internals.
•Make sure the vent hole is always unblocked.
Environmental Conditions
The instrument is designed for indoor use and an area with low condensation.
The table below shows the general environmental requirements for the
instrument.

Copyright © Itech Electronic Co., Ltd. V
IT-M7700 Series User Manual
Environmental Conditions Requirements
Operating temperature 0℃~40℃
Operating humidity 20%~80% (non-condensation)
Storage temperature -20℃~70℃
Altitude Operating up to 2,000 meters
Installation category II
Pollution degree Pollution degree 2
In order to ensure the accuracy of measurement, it is recommended to oper-
ate the instrument half an hour after start-up.
Regulation Tag
The CE tag shows that the product complies with the
provisions of all relevant European laws (if the year is
shown, it indicates that the year when the design is
approved).
The UKCA tag shows that the product complies with
the provisions of all relevant United Kingdom laws (if
the year is shown, it indicates that the year when the
design is approved).
This instrument complies with the WEEE directive
(2002/96/EC) tag requirements. This attached product
tag shows that the electrical/electronic product cannot
be discarded in household waste.
This symbol indicates that no danger will happen or
toxic substances will not leak or cause damage in nor-
mal use within the specified period. The service life of
the product is 10 years. The product can be used
safely within the environmental protection period; oth-
erwise, the product should be put into the recycling
system.

Copyright © Itech Electronic Co., Ltd. VI
IT-M7700 Series User Manual
Waste Electrical and Electronic Equipment
(WEEE) Directive
Waste electrical and electronic equip-
ment (WEEE) directive, 2002/96/EC
The product complies with tag re-
quirements of the WEEE directive
(2002/96/EC). This tag indicates that
the electronic equipment cannot be
disposed of as ordinary household
waste. Product Category
According to the equipment classifi-
cation in Annex I of the WEEE direc-
tive, this instrument belongs to the
“Monitoring” product.
If you want to return the unnecessary
instrument, please contact the near-
est sales office of ITECH.

Copyright © Itech Electronic Co., Ltd. VII
IT-M7700 Series User Manual
Compliance Information
Complies with the essential requirements of the following applicable European
Directives, and carries the CE marking accordingly:
•Electromagnetic Compatibility (EMC) Directive 2014/30/EU
•Low-Voltage Directive (Safety) 2014/35/EU
Conforms with the following product standards:
EMC Standard
IEC 61326-1:2012/ EN 61326-1:2013 ¹²³
Reference Standards
CISPR 11:2015+A1:2016 Ed 6.1
IEC 61000-3-2: 2018 RLV
IEC 61000-3-3: 2013+A1:2017
IEC 61000-4-2:2008
IEC 61000-4-3 2006+A1:2007+A2:2010/ EN 61000-4-3 A1:2008+A2:2010
IEC 61000-4-4:2012
IEC 61000-4-5:2014+A1:2017
IEC 61000-4-6:2013+cor1:2015
IEC 61000-4-11:2004+A1:2017
1. The product is intended for use in non-residential/non-domestic environments. Use of the
product in residential/domestic environments may cause electromagnetic interference.
2. Connection of the instrument to a test object may produce radiations beyond the specified
limit.
3. Use high-performance shielded interface cable to ensure conformity with the EMC standards
listed above.
Safety Standard
IEC 61010-1:2010+A1:2016

Copyright © Itech Electronic Co., Ltd. VIII
IT-M7700 Series User Manual
Content
Quality Certification and Assurance .................................................................................. I
Warranty ............................................................................................................................ I
Limitation of Warranty........................................................................................................ I
Safety Symbols................................................................................................................. II
Safety Precautions............................................................................................................ II
Environmental Conditions................................................................................................ IV
Regulation Tag ................................................................................................................. V
Waste Electrical and Electronic Equipment (WEEE) Directive ....................................... VI
Compliance Information.................................................................................................. VII
1 Quick Reference................................................................................................................. 1
1.1 Brief Introduction...................................................................................................... 1
1.2 Front Panel at a Glance ........................................................................................... 2
1.3 Front Panel Keys at a Glance .................................................................................. 4
1.4 Rear Panel at a Glance............................................................................................ 6
1.5 Front Panel Display at a Glance .............................................................................. 8
1.6 Configuration Menu at a Glance ............................................................................ 10
1.7 System Menu at a Glance...................................................................................... 13
1.8 Optional Accessories ............................................................................................. 17
2 Inspection and Installation................................................................................................ 20
2.1 Verifying the Shipment........................................................................................... 20
2.2 Instrument Size Introduction .................................................................................. 21
2.3 Connecting the Power Cord................................................................................... 23
2.4 Connecting the Device Under Test (DUT) ............................................................. 26
2.5 Connecting the Interface........................................................................................ 29
2.5.1 USB Interface .............................................................................................. 30
2.5.2 GPIB Interface ............................................................................................. 31
2.5.3 LAN Interface............................................................................................... 31
2.5.4 RS-232 Interface ......................................................................................... 37
2.5.5 CAN Interface .............................................................................................. 39
2.5.6 RS-485 Interface ......................................................................................... 41
3 Getting Started ................................................................................................................. 43
3.1 Power-on the Instrument ....................................................................................... 43
3.2 Applying DC Output ............................................................................................... 45
3.3 Applying Waveform Output.................................................................................... 46
4 Operation and Application................................................................................................ 49
4.1 Select the Output Mode ......................................................................................... 49
4.2 Setting the Voltage Output Range ......................................................................... 50
4.3 Set the AC Output .................................................................................................. 51
4.3.1 Set the AC Voltage ...................................................................................... 51
4.3.2 Set the AC Frequency ................................................................................. 52
4.3.3 Set the AC Phase Angle .............................................................................. 52
4.3.4 Select the Output Waveform ....................................................................... 53
4.4 Set the DC Output.................................................................................................. 54
4.4.1 Set the DC Voltage ...................................................................................... 54
4.4.2 Set the DC Voltage Rise Time..................................................................... 54
4.5 Set the Over-current Protection Point ................................................................... 55
4.6 Turning the Output On and Off .............................................................................. 56
4.7 Step or Continue Output ........................................................................................ 56
4.8 Executing Measurement ........................................................................................ 57
4.8.1 Measurement Functions.............................................................................. 58
4.9 Function Operation ................................................................................................ 59
4.9.1 Function Menu at a Glance ......................................................................... 59
4.9.2 List Function ................................................................................................ 62
4.9.3 Dimmer Function ......................................................................................... 64
4.9.4 Surge/Trap Function.................................................................................... 65

Copyright © Itech Electronic Co., Ltd. IX
IT-M7700 Series User Manual
4.9.5 Digital I/O Function ...................................................................................... 67
4.9.6 Set the Output Timer Function .................................................................... 71
4.10 Protection Function.............................................................................................. 71
4.10.1 Set the Over-Voltage Protection (rms) ...................................................... 71
4.10.2 Set the Over-Voltage Protection (peak) .................................................... 72
4.10.3 Set the Under-Voltage Protection (rms) .................................................... 73
4.10.4 Set the Over-Current Protection (rms) ...................................................... 73
4.10.5 Set the Over-Current Protection (peak) .................................................... 75
4.10.6 Set the Over-Power Protection.................................................................. 76
4.10.7 Set the Current Limiting Protection ........................................................... 76
4.10.8 Set the Sense Check Protection ............................................................... 77
4.10.9 Limiting the Setting Value Range .............................................................. 78
4.11 System-Related Operations ................................................................................ 79
4.11.1 Switch Local/Remote Mode....................................................................... 79
4.11.2 Save and Recall Operations...................................................................... 79
4.11.3 Key Lock Function ..................................................................................... 80
4.11.4 Set the Beeper Status ............................................................................... 80
4.11.5 Set the Power-on State ............................................................................. 80
4.11.6 Restore the as-shipped settings................................................................ 81
4.11.7 View the System Information..................................................................... 85
4.11.8 Set the Relay Control ................................................................................ 86
4.12 External Analog Quantity Function (Option) ........................................................ 87
4.12.1 Definition of Analog Interface .................................................................... 87
4.12.2 Enable/Disable Analog Control ................................................................. 89
4.12.3 Analog Quantity Control ............................................................................ 90
4.12.4 Calibrate external voltage control.............................................................. 94
5 Multi-units operation ......................................................................................................... 96
5.1 Series Operation .................................................................................................... 96
5.2 Three-phase Operation.......................................................................................... 99
5.3 Multi-Channel Function........................................................................................ 103
6 Routine Maintenance ..................................................................................................... 106
6.1 Instrument Self-Test............................................................................................. 106
6.2 Cleaning and Maintenance .................................................................................. 106
6.3 Prompt Information Reference............................................................................. 107
6.4 Contact of ITECH Engineers ............................................................................... 108
6.5 Return for Repair.................................................................................................. 110
7 Technical Specification .................................................................................................. 111
7.1 IT-M7721.............................................................................................................. 111
7.2 IT-M7721L............................................................................................................ 113
7.3 IT-M7722.............................................................................................................. 115
7.4 IT-M7722D ........................................................................................................... 118
7.5 IT-M7722E ........................................................................................................... 120
7.6 IT-M7722L............................................................................................................ 122
7.7 IT-M7723.............................................................................................................. 124
7.8 IT-M7723D ........................................................................................................... 127
7.9 IT-M7723E ........................................................................................................... 129
A Appendix ........................................................................................................................ 132
A.1 Specifications of Red and Black Test Cables ..................................................... 132
A.2 Built -in Waveforms ............................................................................................. 133

Quick Reference
1Quick Reference
This chapter briefly introduces the front panel, rear panel, keyboard button func-
tions and front panel display functions of this series instrument to ensure a quick
understanding of the appearance, structure and key usage features of the in-
strument before operating the instrument. This chapter does not introduces
each operating characteristics in detail. It is just a quick reference guide to help
you quickly learn the operating characteristics of the instrument.
♦Brief Introduction
♦Front Panel at a Glance
♦Front Panel Keys at a Glance
♦Rear Panel at a Glance
♦Front Panel Display at a Glance
♦Configuration Menu at a Glance
♦System Menu at a Glance
♦Optional Accessories
1.1 Brief Introduction
ITECH newly-launched IT-M7700 High Performance Programmable AC Power
Supply combines intelligence and flexibility, breaks through the huge defects of
the traditional AC power source, reduces the size to only 1⁄2 1U, maximizes
space utilization. Built-in power meter and arbitrary waveform generator make it
convenient to simulate various arbitrary waveform outputs. IT-M7700 is de-
signed with advanced technologies of programmable AC and DC power sup-
plies, and can be widely used in multiple fields such as power energy products,
home appliances and industrial electronics.
Features:
•1⁄2 1U compact design, increased space utilization
•AC, DC, AC + DC output modes, DC voltage offset simulation in AC + DC
mode
•Built-in AC power meter with powerful functions
•Built-in abundant waveform database, including 30 harmonic distortion
waveforms *1
•List mode, simulate civil AC working condition, realize instantaneous power
interruption simulation function *1*2
•Arbitrary waveform output function, user can customize waveforms *1
•Harmonic analysis and simulation function *1
Copyright © Itech Electronic Co., Ltd. 1

Quick Reference
•Surge/Trap function *1
•Front and rear edge Dimmer phase dimming function Settable output wave-
form start/stop phase angle *1
•Settable output waveform start/stop phase angle
•Higher voltage available by two units in series connection *1*3
•Three phase output available by three units Y-type external
connections *1*3
•CF=6,good for the inrush current test at the start moment *1*4
•Optional interfaces include RS232, RS485, CAN, LAN, GPIB, USB_TMC,
USB_VCP, external analog, IO. Flexible and cost effective
*1 IT-M7721L/IT-M7722L do not support this function.
*2 Realize by PC software.
*3 Available on IT-M7721/7722/7722D/7722E/7723D/7723E.
*4 Only available for the model IT-M7722D,IT-M7723D.
Model Selection Table for IT-M7700 Series:
Model Power(AC/DC) Voltage Current Frequency Height
IT-M7721 300 VA/300 W 300 V 3 A 45~1000 Hz 1U half-rack
IT-M7722 600 VA/600 W 300 V 6 A 45~1000 Hz 1U half-rack
IT-M7723 1200VA/1200W 300V/600V 12A/6A 45~1000 Hz 1U
IT-M7722D 300 VA/300 W 300 V 3 A 45~1000 Hz 1U half-rack
IT-M7723D 750 VA/750 W 300 V 7.5 A 45~1000 Hz 2U half-rack
IT-M7722E 1000VA/1000W 300V 10A 45~1000 Hz 2U half-rack
IT-M7723E 1500VA/1500W 300V 15A 45~1000 Hz 2U half-rack
IT-M7721L 300 VA/300 W 300 V 3 A 45~100 Hz 1U half-rack
IT-M7722L 600 VA/600 W 300 V 6A 45~100 Hz 1U half-rack
For detailed technical specifications, please refer to 7 Technical
Specification.
1.2 Front Panel at a Glance
The front panel of this series instruments is shown below.
Copyright © Itech Electronic Co., Ltd. 2

Quick Reference
•IT-M7721/IT-M7722/IT-M7721L/IT-M7722L/IT-M7722D front panel
•IT-M7723 front panel
•IT-M7723D/IT-M7722E/IT-M7723E front panel
No. Name Description
1[Shift]key Composite key, combined with other keys to realize
functions marked above keys.
2[Link](Local)
key
The functions is described as follows.
•[Link] key. When the instrument is connected to
the PC through the LAN interface, this key will
light up.
•Local switch key. In remote control, press
[Shift] + [Link] (Local) keys to switch the instru-
ment to local control mode.
3 Power switch Turns the instrument on or off.
4 Vacuum fluo-
rescent display
Displays all instrument functions. The information
changes based on selected function.
Copyright © Itech Electronic Co., Ltd. 3

Quick Reference
No. Name Description
5 Function keys
group
Please refer to 1.3 Front Panel Keys at a Glance for
detailed description about the function keys.
6 Push button
rotary
The functions is described as follows.
•Rotate the push button rotary to adjust the value
setting or scroll pages to view menu items. Ro-
tate the push button rotary clockwise to increase
the set value and anticlockwise to decrease the
set value
•Pressing the push button rotary acts like press-
ing [Enter] key to confirm an operation.
7 The left/right
navigation keys
and composite
keys
The functions is described as follows.
•The left and right navigation keys are used to
adjust the cursor to the specified position or
scrolls pages to view menu items.
•Save/Recall the present settings.
8 Numeric keys The Numeric entry keys do the following.
•The 0 through 9 keys enter numbers.
•The (.) key is the decimal point.
•The ± key is used to enter a positive or negative
signs.
1.3 Front Panel Keys at a Glance
The keys introduction of IT-M7700 series power source is shown as follows.
•IT-M7721/IT-M7722/IT-M7721L/IT-M7722L/IT-M7722D/IT-M7723D/IT-
M7722E/IT-M7723E keys
•IT-M7723 keys
Copyright © Itech Electronic Co., Ltd. 4

Quick Reference
Table 1–1 Keys Description
Key Name Description
[Select] •AC Mode: Switches the AC main interface. Use this
key to switch the AC main interface 1 and AC main in-
terface 2.
•DC Mode: [Select] key is not available.
[V-set] Sets the output voltage value.
[I-set] Sets the OCPrms value.
[AC] Press the [AC] key to set the instrument to AC output
mode.
[DC] Press the [DC] key to set the instrument to DC output
mode.
[F-set] •AC Mode: Sets the frequency value.
•DC Mode: [F-set] key is not available.
[On/Off] Turns the instrument output on or off. When lit, indicates
that the output is on.
[Esc] Press this key to exit the current operation interface.
[Enter] Selects the menu item or confirm an operation.
[0]-[9] Numeric keys.
+/– Positive and negative signs.
.Decimal point.
The left and right navigation keys are used to adjust the
cursor to the specified position or scrolls pages to view
menu items.
Copyright © Itech Electronic Co., Ltd. 5

Quick Reference
Display is only used to prompt that the [Select] key is the display switch key
of the AC main interface, and has no other functions.
Composite key [Shift], combined with other keys to realize functions marked
above keys. The detailed functions are listed as follows.
Table 1–2 Composite keys Description
Key Name Description
[Shift]+[V-set](Config) Enter the Config menu.
[Shift]+[I-set](Function) Enter the Function menu.
[Shift]+[DC](System) Enter the System menu.
[Shift]+[F-set](Protect) Enter the Protect menu.
[Shift]+[On/Off]
(Trigger)
Generate a local trigger signal.
[Shift]+[Enter](lock) Turn the keyboard lock on or off.
[Shift]+ (Save) Saves the present settings.
[Shift]+ (Recall) Returns the instrument to the specified setup.
1.4 Rear Panel at a Glance
The rear panel of this series instruments is shown below.
•IT-M7721/IT-M7722/IT-M7721L/IT-M7722L/IT-M7722D rear panel
•IT-M7723 rear panel
Copyright © Itech Electronic Co., Ltd. 6

Quick Reference
•IT-M7723D/IT-M7722E/IT-M7723E rear panel
No. Name Description
1 Output terminals AC or DC output terminals and chassis ground ter-
minals, used to connect DUT.
2 System bus
interfaces
Used for communication between instruments in
three phase or series operation feature.
3 Extended option-
al interface
Optional interfaces: (Plastic plugs are inserted by
default when the user does not purchase the
interface.)
•USB and LAN interfaces;
•GPIB interface;
•RS-232 and CAN interfaces;
•Analog and RS-485 interfaces.
4 Remote sense
terminals, Output
lock terminals
and I/O terminals
The descriptions of each terminals are as follows.
•SL+ and SN- are remote sense terminals, used
for maximizing measurement accuracy.
•L+ and N- are output terminals. These two ter-
minals are not suitable for transmitting large
current. Therefore, they cannot be connected
to the DUT, which are only used for short circuit
during local measurement.
•I/O function, please refer to 4.9.5 Digital I/O
Function.
Copyright © Itech Electronic Co., Ltd. 7

Quick Reference
No. Name Description
5 Ground screw Ground screw for making chassis ground
connections.
6 AC power input
socket
Used to connect AC power to start instrument,
supports 100 V to 240 V.
1.5 Front Panel Display at a Glance
The IT-M7700 series power supply has different display information under the
AC mode and the DC mode. Details are as follows.
•Under the AC mode, the AC main interface 1 is displayed as follows:
No. Name Description
1 Vac set value
/Vrms meter
value
•When output is Off, the AC voltage setting
value is displayed.
•When output is On, the Meter value of volt-
age effective value is displayed.
2 OCPrms set
value
/Irms meter
value
•When output is Off, the OCPrms setting val-
ue is displayed.
•When output is On, the Meter value of cur-
rent effective value is displayed.
3 Freq set value
/Freq meter
value
•When output is Off, the frequency setting val-
ue is displayed.
•When output is On, the Meter value of fre-
quency value is displayed.
4 P meter value Displays the Meter value of the active power.
Copyright © Itech Electronic Co., Ltd. 8

Quick Reference
No. Name Description
5 Ip meter value Displays the Meter value of the maximum cur-
rent peak value.
6 PF meter value Displays the Meter value of the power factor.
•Under the AC mode, the AC main interface 2 is displayed as follows:
No. Name Description
1 Vac set value
/Vrms meter value •When output is Off, the AC voltage set-
ting value is displayed.
•When output is On, the Meter value of
voltage effective value is displayed.
2 OCPrms set value
/Irms meter value •When output is Off, the OCPrms setting
value is displayed.
•When output is On, the Meter value of
current effective value is displayed.
3 Q meter value Displays the Meter value of the reactive
power.
4 P meter value Displays the Meter value of the active
power.
5 S meter value Displays the Meter value of the apparent
power.
6 vTHD meter value Displays the Meter value of the total voltage
harmonic distortion.
iTHD meter value Displays the Meter value of the total current
harmonic distortion.
Copyright © Itech Electronic Co., Ltd. 9
Other manuals for IT-M7700 Series
2
This manual suits for next models
9
Table of contents
Other I-Tech Portable Generator manuals