20m 40m
{
L2
A1
A2
Reed Switch
K8*
2K2 - 2W
A1+
A2-
Reed Switch
KD*
+
+
D = 20 ~ 40m
22R 5W
R
K8*
220R 5W
R
The sensors work in all voltage and current ranges displayed in the table bellow:
Operating Voltage Max. Switching Power Max. Switching Current Peak Current
110Vac 20VA 0.2A 0.5A @20ms
220Vac 20VA 0.1A 0.5A @20ms
5Vdc 2.5W 0.5A 1A @20ms
12Vdc 5W 0.5A 1A @20ms
24Vdc 10W 0.5A 1A @20ms
24Vac: NOT recommended
AC Current: Use K8 Filter*in parallel with the coil (A1 A2) of a contactor or relay.
DC Current: Use KD Filter* in parallel with the coil (A1 A2) of a contactor or relay.
*On accessories.icos.us check models and prices of Filters and Mini Contactor
K8 Snubber Filter for
electrical installation (AC)
(included)
Term of Warranty
Operation
Typical Connection to Contactor
Electrical Contact of Sensors - Attention to Install
! Never connect the sensor
directly to a motor, pump,
lamp or any other load
over 20W.
Always use a contactor or
relay.
Manual
C.01/Oct2017
0.1µF 400V
*For sale on accessories.icos.us
Flow Switches
Models for G 1/4” Port
IMPORTANT !
YOU MUST CHECK BEFORE INSTALLATION
For installations according to this guide:
02 (two) years warranty. Incorrect installation cancels the warranty.
All Sensors have been tested and approved during the manufacture process.
Reed Switch 20W/VA: Protect the Electrical Contact of your Sensor
Siemens 3RT1015 Contactor
Initial: 31.7VA
Rated: 5.1VA
icos.net
• Liquids with solid particles and/or fouling require prior
testing. Use lter before the Sensor to prevent the internal piston
from locking. Not recommended for industrial water waste.
• Liquids with ferrous and/or magnetic particles require
technical analysis: the Sensor contains magnetic components
inside. Use a magnetic lter before the Sensor to avoid
deposition/settling that will prejudice its operation.
Direct connection
to the sensor
Use 22R 5W*
resistor in series Use
24Vdc Voltage
• AUXILIARY CONTACTOR (mini contactor) mind the distance:
• SOLENOID VALVE or POWER CONTACTOR:
Use mini contactor or auxiliary relay.
• ELECTRONIC EQUIPMENT:
› Interface relay/relay coupler: Use 4K7 10W resistor.
› Timing relay and frequency inverter: Use 220R 5W*resistor.
Follow the instructions below to protect and extend the shelf life of the sensor:
Questions? Call us BEFORE you install:
+55 (15) 3032.9190
levelsensor.icos.us | datasheets.icos.us | videos.icos.us
K8 for AC
KD for DC
Snubber
Filter
Installing the snubber
lter extends the
lifespan of the sensor’s
electrical contact.
On datasheets.icos.us available technical specications
+55 (15) 3032.9190
Reed Switches are hermetically sealed
contacts actuated by a magnetic eld.
The life expectancy of a reed switch refers to a kind of load to be
used. Reed Switches of the highest reliability are applied in our
sensors, and their life expectancy can reach above two million
operations. However, when they are switching lamps, inductive or
capacitive loads, this number may decrease.
Switching Power
It is important to consider that the power specied by an electrical
load is often referred to the permanent working state.
For higher power, use an auxiliary relay or contactor as recommended
below, or similar.
Note: Reed Switches have reached over one million operations in
tests with contactor and K8* snubber lter.
PROTECTION PROCEDURES BELOW DESCRIBED CAN
IMPROVE THE REED SWITCH PERFORMANCE
Flow Switches and Level Switches for liquids
K8* Filter mounted in parallel
with the coil of an AC contactor,
increases the contact life.
KD* Filter mounted in parallel
with the coil of a DC relay,
increases the contact life.
Important: For distances greater than 40m, use 24Vdc voltage.
•Timing relay
•Frequency inverter
•Etc.
Important: For installation with relay coupler, use 4K7 10W resistor.
• Switching inductive loads
? Risk of failure (welding of the Reed Switch Contact) due to CAPACITANCE, which
can occur depending on the distance and cable used in the connection to the contactor.
• Connecting the sensor to a contactor in long distances, use resistor:
This resistor dampens the peak voltage caused by the
capacitance of cables and electronic equipment input.
• Connecting the sensor to an electronic equipment:
Contactor Contactor
BY448
or
1N4007
0
a
a
ara
a
a
a
a
a
a
ra
ar
53
26
49
13
98
32
Ø12
1
3
A-coding
On datasheets.icos.us available technical specications
O’Ring (NBR) for sealing
Parker code 2-111
(included)
GAS (BSP) Thread
The sealing is made on the ring.
It’s not necessary sealant tape
or over tightening
Installation
Maintenance
PPA (Polyphthalamide)
AISI 304 stainless steel
8mm2
25bar
0°C to 100°C | 140°C @1h
G 1/4” female (BSP - Parallel)
NBR (nitrilic rubber) O’Ring
M12 male plug (2 pins)
M12 female connector NOT included
IP66
Reed Switch 20W/VA (NO SPST)
71g
Body
Spring
Internal clearance
Maximum operating pressure
Operating temperature range
Inlet/outlet port
Sealing
Output connection
Enclosure rating
Electrical contact
Weight
• In applications without excessive vibration;
• Minimum distance of 20mm from any ferrous surface;
• Mounting with parallel port connection and O’Ring.
* Approximate values with reference in water
M12 female
connector
Male M12 plug
2 pins
Flow
Switch
Electrical Connection
Sealing
1. Open the plug, remove the spring and clean using a brush
if there is encrustation;
2. Mount the sensor again as illustrated beside;
3. Test the electrical contact using an ohmmeter, moving the
magnetic piston.
Flow Rate Sensitivity Adjustment
Results of the
sensitivity test
(xed in the package)
Allen wrench to
adjust the sensitivity
(included)
Suitable for Detection of Low Flows
Fluid ow through the sensor triggers precise displacement of a magnetic piston acting on an electrical contact (Reed Switch).
Mounting
WRONG
Hex screw for senstivity adjustment
Inlet tting
Flow
direction
Outlet
tting
Dimensions in millimeters.
UPWARD FLOW
In water. Set point accuracy: ±15%.
Repeatability (not considering the viscosity change of liquids): ±10%.
FLOW INCREASE - ON
FLOW DECREASE - OFF 8LPM
Scale Body Piston Spring O’Ring Plug
Output plug
M12 plug
Technical Specications
3-BL
1-BR
Flow Switches and Level Switches for liquids
Model Actuation range*
FA14B02-M12 From ~0.8 to ~5LPM
FA14B04-M12 From ~1.7 to ~7LPM
FA14B06-M12 From ~2.5 to ~8LPM

This manual suits for next models

2

Other Icos Switch manuals

Icos LA12N-40 User manual

Icos

Icos LA12N-40 User manual

Icos MVS6000 User guide

Icos

Icos MVS6000 User guide

Popular Switch manuals by other brands

Vista QSW4 instruction manual

Vista

Vista QSW4 instruction manual

SMC Networks ZSE40A instruction manual

SMC Networks

SMC Networks ZSE40A instruction manual

Conceptronic HUBBIES09B manual

Conceptronic

Conceptronic HUBBIES09B manual

AETEK H51-044-30-150 Quick installation guide

AETEK

AETEK H51-044-30-150 Quick installation guide

JenLogix Palert PX-01 Series user manual

JenLogix

JenLogix Palert PX-01 Series user manual

Sky now user manual

Sky

Sky now user manual

Panasonic GA-AS48T installation guide

Panasonic

Panasonic GA-AS48T installation guide

Linkskey LDV-DM02ESK Quick installation guide

Linkskey

Linkskey LDV-DM02ESK Quick installation guide

nLight rPODU instructions

nLight

nLight rPODU instructions

Edimax ES-5824P datasheet

Edimax

Edimax ES-5824P datasheet

Kramer WP-20CT user manual

Kramer

Kramer WP-20CT user manual

MiLAN MIL-SME801P release note

MiLAN

MiLAN MIL-SME801P release note

H3C S5560S-EI Series installation guide

H3C

H3C S5560S-EI Series installation guide

Cisco Catalyst 2960 Series Hardware installation guide

Cisco

Cisco Catalyst 2960 Series Hardware installation guide

Atop EH7506-4PoE-2SFP user manual

Atop

Atop EH7506-4PoE-2SFP user manual

ANTAIRA LMP-0804G-SFP Series Hardware manual

ANTAIRA

ANTAIRA LMP-0804G-SFP Series Hardware manual

Goobay MS-506 quick start guide

Goobay

Goobay MS-506 quick start guide

PCB Piezotronics IMI SENSORS EX686B01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS EX686B01 Installation and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.