SI-002

SI-002 User Manual, version 1.0 Page: 2
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Warranty
All products manufactured by ICP DAS are under warranty regarding defective
materials for a period of one year, beginning from the date of delivery to the original
purchaser.
Warning
ICP DAS assumes no liability for any damage resulting from the use of this
product.ICP DAS reserves the right to change this manual at any time without notice.
The information furnished by ICP DAS is believed to be accurate and reliable.
However, no responsibility is assumed by ICP DAS for its use, not for any
infringements of patents or other rights of third parties resulting from its use.
Copyright
Copyright @ 2016 by ICP DAS Co., Ltd. All rights are reserved.
Trademark
The names used for identification only may be registered trademarks of their
respective companies.
Contact US
If you have any problem, please feel free to contact us.
You can count on us for quick response.
Email: service@icpdas.com

SI-002 User Manual, version 1.0 Page: 3
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Table of Contents
Table of Contents ..................................................................................3
1. Introduction .......................................................................................4
1.1. Features ....................................................................................................... 5
1.2. Specification ................................................................................................. 5
1.3. DIO Wiring Connection................................................................................. 7
1.4. Overview ...................................................................................................... 8
1.4.1. Front Panel......................................................................................... 8
1.4.2. Back Panel ......................................................................................... 9
1.5. Dimensions................................................................................................. 12
2. Getting Started ................................................................................13
2.1. Connecting to Network, PC and Power ...................................................... 13
2.2. Installing the MicroSIP Utility ...................................................................... 14
2.3. Using SI-002 connect to MicroSIP Utility .................................................... 15
3. Web Applications ............................................................................19
3.1. Connect to SI-002 web site ........................................................................ 19
3.1.1. Installing the eSearch Utility ............................................................. 19
3.1.2. Connecting ....................................................................................... 21
3.2. Web Configuration...................................................................................... 22
3.2.1. Function menu.................................................................................. 23
3.2.2. Login ................................................................................................ 23
3.2.3. User Account .................................................................................... 23
3.2.4. Standard Config................................................................................ 24
3.2.5. Audio Config ..................................................................................... 25
3.2.6. RFID Config...................................................................................... 26
3.2.7. Information ....................................................................................... 27

SI-002 User Manual, version 1.0 Page: 4
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
1. Introduction
SI-002 is video intercom door station that supports VoIP
technology and SIP communication protocol. With HA-401
product, households can see visitors' images and have a video
conversation with them when the door bell ringing, after identity
confirmation, they can open the door remotely. Using
high-resolution CMOS camera and advanced echo cancellation
technology can show a clearer picture and excellent audio quality
and timeliness of transport. It is a compact video intercom
solution for building residential.

SI-002 User Manual, version 1.0 Page: 5
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
1.1. Features
Full-duplex voice and video intercom
Support for SIP communications architecture
Using high-resolution camera 1080P (1920 x 1080)
Advanced echo cancellation technology
Built-in high sensitivity microphone and speaker
Built-in call button
Built-in Relay output channel (door control or alarms output)
Built-in Digital input channel (door magnetic switch detection
or external emergency button)
1.2. Specification
System
CPU
Cortex A8 CPU (720 MHz)
SRAM
512 MB
Flash Memory
512 MB
EEPROM
16 KB
Communication
Ethernet Port
10/100 Base-TX (Auto-negotiating, Auto
MDI/MDI-X, LED indicators)
Digital Input
Channels
2
Input Type
Dry contact (Source)
Dry Contact Level
Off Voltage Level:
Open
On Voltage Level:
Close to GND

SI-002 User Manual, version 1.0 Page: 6
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Relay Output
Channels
1
Output Type
Form C (N.O./COM./N.C.)
Contact Capacity
0.6A @ 125 VAC; 2A @ 30 VDC
HMI
Camera
1080P (1920 x 1080), CMOS Sensor
Audio
AMP 2.5 W; Digital microphone
Mechanical
Dimensions
102 mm x 161 mm x 41 mm (W x L x H)
Installation
Wall Mounting (Suitable for the European 86 mm x
86 mm outlet box)
Environment
Operating Temperature
-25 ˚C ~ +60 ˚C
Storage Temperature
-30 ˚C ~ +80 ˚C
Humidity
10 ~ 90 % RH, non-condensing
Power Supply
Input Range
+10 VDC ~ +48 VDC
Power Consumption
1.5 W @ 24 VDC Max.
Protection
Reverse Polarity Protection

SI-002 User Manual, version 1.0 Page: 7
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
1.3. DIO Wiring Connection

SI-002 User Manual, version 1.0 Page: 8
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
1.4. Overview
Here is a brief overview of the components and its descriptions for module status.
1.4.1. Front Panel
Speaker
Call Button
Camera
Microphone

SI-002 User Manual, version 1.0 Page: 9
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Call Button with LED Indicator
When the module is off line and user push call button, the module will dial to
preset sip client. When the module is online and user push call button, the
module will end current call.
LED Indicator is shown current status, as shown in the below.
LED Action
Current status
High brightness
On line
Low brightness
Off line
1.4.2. Back Panel
Ethernet Port
J1 Connector
(Pin 1 ~ 8)
RSW

SI-002 User Manual, version 1.0 Page: 10
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
RSW (Rotary Switch)
.
RSW Value
Function
A
Set network interface to DHCP
mode
B
Set network interface to static IP
mode.
IP: 192.168.72.30
Mask: 255.255.0.0
Gateway: 192.168.1.1
E
FW Update Mode
F
Recover system settings
Other
N/A
Ethernet Port
An Ethernet port is an opening on SIP network equipment that Ethernet cables
plug into. Ethernet ports accept cables with RJ-45 connectors.
J1 Connector

SI-002 User Manual, version 1.0 Page: 11
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Pin
Name
Description
1
+Vs
V+ of Power Supply(
2
GND
GND of Power Supply
3
DI0
Digital Input CH0
4
DI1
Digital Input CH1
5
DI.GND
Digital Input GND
6
RL.NO
Relay Normally-Open
7
RL.COM
Relay Common
8
RL.NC
Relay Normally-Closed

SI-002 User Manual, version 1.0 Page: 12
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
1.5. Dimensions
All dimensions are in millimeters.

SI-002 User Manual, version 1.0 Page: 13
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
2. Getting Started
If you are a new user, begin with this chapter, it includes a guided tour that provides a
basic overview of installing, configuring and using the SI-002.
2.1. Connecting to Network, PC and Power
The SI-002 is equipped with an RJ-45 Ethernet port for connection to an Ethernet
hub/switch and PC. Please set RSW of SI-002 and PC Network as below.

SI-002 User Manual, version 1.0 Page: 14
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
2.2. Installing the MicroSIP Utility
The MicroSIP Utility is a open source portable SIP softphone based on PJSIP stack
for Windows OS. The user can use this Utility to connect with SI-002.
Step 1: Get the MicroSIP Utility tool
The MicroSIP Utility can be obtained from below link:
http://www.microsip.org/downloads
Step 2: Follow the prompts to complete the installation

SI-002 User Manual, version 1.0 Page: 15
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
2.3. Using SI-002 connect to MicroSIP Utility
When RSW of SI-002 set to B, SI-002 will use a default IP settings to connect PC.
The default IP settings are as follows:
SI-002
IP Address
192.168.72.30
Subnet Mask
255.255.0.0
PC side
IP Address
192.168.255.1
Subnet Mask
255.255.0.0
Step 1: Run the MicroSIP Utility
Double-click theMicroSIP Utility shortcut on your desktop.

SI-002 User Manual, version 1.0 Page: 16
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Step 2: MicroSIP settings
a. Click Menu => Settings
b. Select audio codec (enable PCMU, PCMA, GSM) and video codec (enable
H.263+)
Step 3: Making a Phone call
Press call button of SI-002 to call MicroSIP and then the MicroSIP will show
Incoming call. Press "Answer with video" button of MicroSIP to answer call.

SI-002 User Manual, version 1.0 Page: 17
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Step 4: Answer call
Press "Answer with video" button of MicroSIP to answer call. The PC will
show local video and remote video and hear voice from SI-002.

SI-002 User Manual, version 1.0 Page: 18
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com

SI-002 User Manual, version 1.0 Page: 19
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
3. Web Applications
The SI-002 contains an advanced web configuration system that provides users with
configure SI-002 through a standard web browser.
3.1. Connect to SI-002 web site
3.1.1. Installing the eSearch Utility
The user can get current IP of SI-002 by eSearch Utility.
Step 1: Get the eSearch Utility tool
The eSearch Utility can be obtained from below link:
http://www.icpdas.com/root/product/solutions/software/utilities/vxcomm.html
Step 2: Run the eSearch Utility

SI-002 User Manual, version 1.0 Page: 20
Copyright © 2016 ICP DAS Co., Ltd. All Rights Reserved. E-mail: service@icpdas.com
Double-click the eSearch Utility shortcut.
Step 3: Choose “Search Servers”button
After pressing "Search Servers' button, that will search all of the SI-002
modules on your network.
After search, it will show all
of SI-002 modules, the user
can get IP of SI-002
Other manuals for SI-002
2
Table of contents
Other ICP DAS USA Intercom System manuals
Popular Intercom System manuals by other brands

Vimar
Vimar Elvox 6600 Series Installer's guide

Esse-ti
Esse-ti Diamante user manual

tema
tema AA-560 Technical and installation manual

Cardo Systems
Cardo Systems Spirit HD Pocket guide

Bellman & Symfon
Bellman & Symfon BE1411 user manual

AMX
AMX Metreau Entry Communicator with Display... Operation/reference guide