CAUTION: This product is sensitive to Electrostatic Discharges (ESD). Take precautions while handling the product by using
proper grounding straps at all times.
PHYSICAL SPECIFICATIONS
Length: 76 mm (3.00 in)
Width: 48 mm (1.90 in)
Height: 17 mm (0.67 in)
Weight: 34 g (1.20 oz)
Readers: 1
Supervised Inputs: 6
Relay Outputs: 2
This Freedom device is tested to:
Electrical: UL294
EMI Radiation: FCC Part 15 Class B
INSTALLATION REQUIREMENTS
Freedom Bridges should only be installed in dry, non-condensing environments. The ambient temperature of the
environment should range between -40°C and 50°C.
Freedom Encryption Bridges should only be mounted to non-conductive surfaces. Incorrect mounting may short-circuit
the electronics, which will cause it to malfunction.
DC power, reader, input contact, and output device wires should be between 16-28 AWG. They should also be stripped
5.5mm to sufficiently fit the terminal blocks and ensure that they do not come in contact with each other.
INSTALLATION PROCEDURE
For each of the following steps, be sure to reference the wiring diagram on page 2 for additional details:
1. Connect an RS-485 Reader to the RS-485 Reader Input on the Freedom Bridge. The selection of 2-wire or 4-wire
operation is done via UDP configuration, as is the baud rate (nominally 57600)
a. A 2-wire RS-485 reader must be connected with a 4-position connector for +12, A, B, 0v, leaving the other 2 pins (R- and R+)
empty. Connect the +12, A, B and the reader shield wire to 0v terminals on the Reader Input.
b. A 4-wire RS-485 requires a 6-position connector for +12, T-, T+, 0v, R-, R+, where T- means Transmit Inverted signal, and R+
means Receive non-inverted signal.
2. Any unused wires on the reader must be evenly snipped and have their tips insulated using electrical tape or
equivalent. The shield wire on the reader must also be completely insulated to prevent ground loops.
3. If you have any supervised input contacts, wire them to the Digital Contact Inputs using Method 1 or Method 2.
4. If you have any non-supervised input contacts, wire them to the Digital Contact Inputs.
5. If you have a relay output contact, wire it to the Relay Output.
6. Supply power to the Freedom Bridge using either or both of the following methods:
a. Wire 12 - 16Vdc power, up to 400mA, directly to the terminal on the Freedom Bridge.
b. Connect a Cat5, 5e, or Cat6 cable from any non-PoE port on an Ethernet Switch to the RJ-45 port on the
Freedom Bridge.
Note: Ethernet only supports a maximum cable segment length of 100m (328ft). Greater lengths can be achieved
by adding switches or repeaters every 100m (328ft).
7. To add the Freedom Bridge to a Freedom Server and configure it, refer to the Freedom Version 8 Software Guide.
A flashing green “Ready”LED light on the Freedom Bridge circuit board indicates that the bridge is attempting to connect to the server.
A solid green “Ready”LED light indicates that the Freedom Bridge has established a connection to the server and is ready to use.
50-40-485 FREEDOM RS485 BRIDGE™ Installation Guide
EM-40-1HA
Base Plate Mounting
Dim
mm
in
A
116.07
4.57
B
78.74
3.10
C
15.24
0.60
D
85.59
3.37
E
10.16
0.40
F
58.42
2.30
1
Optional DC Power In
0v
DC Power Ground
+12
DC Power Input
Requirements:

10 –16 Vdc
350 mA (50 mA internal)
11/05/19WIRING REFERENCE EM-40-1HAa
Relay Output
Nc
Normally Closed
C
Common
No
Normally Open
Relay Contact:

DC: 30 Vdc @ 1Adc
Digital Contact Inputs
R1-R6
Ground
In1-
In6
Non-Supervised or
Supervised Inputs 1-6
RS-485 Reader (2 Wire)
+12
Power Output
A
Data A Input
B
Data B Input
0v
Ground
RS-485 Reader (4 Wire)
+12
Power Output
T-
Transmit Inverted signal
T+
Transmit non-inverted signal
0v
Ground
R-
Receive inverted signal
R+
Receive non-inverted signal
Power Output using DC:

8.5 –16 Vdc
350 mA Max. Current
Reset Button
Press and hold this button for
10 seconds to reset the
configuration back to default.
50-40-485
NOTE: As long as the total current of
the reader plus a door strike DOES
NOT EXCEED 300mA, you may
power the door strike using the
power out and ground from the
Reader Input terminal block.
1
2
3
4
5
2
3
4
5
1
Black
1N4005
Diode
Red

Popular Wireless Access Point manuals by other brands

ADTRAN NetVanta 150 Specifications

ADTRAN

ADTRAN NetVanta 150 Specifications

Edimax EW-7206APg installation guide

Edimax

Edimax EW-7206APg installation guide

DCN WL8200-XW2 Operation manual

DCN

DCN WL8200-XW2 Operation manual

IgniteNet Spark AC750 quick start guide

IgniteNet

IgniteNet Spark AC750 quick start guide

ADTRAN BLUESOCKET 2135 quick start guide

ADTRAN

ADTRAN BLUESOCKET 2135 quick start guide

Nile NWA1000 manual

Nile

Nile NWA1000 manual

ZyXEL Communications NWA570N user guide

ZyXEL Communications

ZyXEL Communications NWA570N user guide

Aruba Networks 175 series datasheet

Aruba Networks

Aruba Networks 175 series datasheet

Adaptive 12883004SP manual

Adaptive

Adaptive 12883004SP manual

Motorola AP 7161 installation guide

Motorola

Motorola AP 7161 installation guide

Siemens SCALANCE W700 Reference manual

Siemens

Siemens SCALANCE W700 Reference manual

EnGenius EOC5510 user manual

EnGenius

EnGenius EOC5510 user manual

AT&T Alcatel-Lucent 9363 Metro Cell installation guide

AT&T

AT&T Alcatel-Lucent 9363 Metro Cell installation guide

3Com 3CRWE675075 - 11a/b/g Wireless LAN Workgroup... quick start guide

3Com

3Com 3CRWE675075 - 11a/b/g Wireless LAN Workgroup... quick start guide

MRV Communications MRW55 user guide

MRV Communications

MRV Communications MRW55 user guide

TP-Link Auranet Series user guide

TP-Link

TP-Link Auranet Series user guide

Aruba 503H installation guide

Aruba

Aruba 503H installation guide

ActionTec V2000H manual

ActionTec

ActionTec V2000H manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.