ID Lock 1000 Mode specification
HF RFID Reader Page 3 of 7
Contents
1Mode specification...................................................................................................................................................4
1.1 Fixed private mode ............................................................................................................................................ 4
1.2 Temporary public mode..................................................................................................................................... 4
1.3 Fixed public mode.............................................................................................................................................. 4
1.4 Random public mode (factory default).............................................................................................................. 4
2Introduction of Function Buttons .............................................................................................................................4
2.1 Button 1: Set manage card ................................................................................................................................ 4
2.2 Button 2: Set delete card................................................................................................................................... 4
2.3 Button 3: Change mode..................................................................................................................................... 5
2.4 Button 4: Set single/double card mode............................................................................................................. 5
3Sound Prompt Function............................................................................................................................................5
3.1 Card read prompt .............................................................................................................................................. 5
3.2 Unlock/Lock ....................................................................................................................................................... 5
3.3 Warning ............................................................................................................................................................. 5
4Security Function......................................................................................................................................................5
4.1 Locking of illegal card......................................................................................................................................... 5
4.2 Low voltage alarm.............................................................................................................................................. 5
4.3 Power saving...................................................................................................................................................... 5
5Installation...............................................................................................................................................................6
6Technical Data..........................................................................................................................................................7

Mode specification Instruction Manual
Page 4 of 7 RFID Devices
1Mode specification
Setting mode: Press button 3
1.1 Fixed private mode
After sound “di”, lock bolt stick out.
Read the card →motor rotate, lock open →after 3s, lock bolt stick out, lock close
1.2 Temporary public mode
After sound “di, di”, the lock bolt retracts.
•It keeps unlock before read any temporary card.
•Users can swiping any card to lock, and use the same card to open.
1.3 Fixed public mode
After sound “di, di, di”, the lock bolt stick out.
•It keeps lock before read card.
•After change to fixed public mode, need to set fixed card through manage card.
•After set fixed card, swiping card to open lock, the lock bolt will keep retracted.
•Swiping the fixed card to close the lock.
1.4 Random public mode (factory default)
•Before setting mode, user can use any card to close the lock, and need use the same card to open the lock.
•After setting mode and setting manage card, change to temporary public mode.
2Introduction of Function Buttons
2.1 Button 1: Set manage card
Press button 1 for 2s, the lock issue a short “di”, then enter into card configuration, swiping one card to be manage card.
•After long sound “di”, the green light will flash, it means setting the card successfully.
•After two short sound “di, di”, the red light will flash, it means setting the card unsuccessfully.
•Can only set one card to be managing card.
•The manage card can only be used to set card but cannot be used to open the lock (Only temporary public mode
can open the lock).
Remark: Set user card (only Fixed private mode & Fixed public mode)
•Swiping manage card, the lock issue “di”, then enter into card configuration, the green light will flash , then
swiping one card to be user card.
•After sound “di”, it means setting the user card successfully.
•Can set user card continuously as long as the green light flash.
Each lock can accept 50pcs card at most.
2.2 Button 2: Set delete card
•Press button 2 for 2s, the lock issue a short “di” and enter into setting card, swiping one card to be delete card.
•Delete card can delete all users cards at one-time but cannot delete the manage card.
•Delete card cannot be used to open the lock.

ID Lock 1000 Sound Prompt Function
HF RFID Reader Page 5 of 7
2.3 Button 3: Change mode
•Factory mode: Random public mode .
•Press button 3, the lock issue a short “di” and enter into fixed private mode.
•Press button 3, the lock issue short “di, di” and enter into temporary public mode.
•Press button 3, the lock issue short “di, di, di” and enter into fixed public mode.
2.4 Button 4: Set single/double card mode
•Press button 4, the lock issue a short “di” and enter into single card mode. Under this mode, can only set user
card.
•Press button 4, the lock issue short “di, di” and enter into double card mode. Under this mode, can set user card
+ staff card at the same time.
Notes:
•After change mode, user cards and staff cards will be invalid. But manage card and delete card are still valid.
•Press button “Reset”, the lock issue short “di, di, di” and will be initialized. All cards will be invalid and lock system
will be back to random public mode.
3Sound Prompt Function
3.1 Card read prompt
According to different functions or states, the lock will issue sound as: “di”, “di, di”, “di, di, di” or a long “di”.
3.2 Unlock/Lock
After read the card successfully, the motor will rotating back and forth, the lock will issue sound “di”
3.3 Warning
Can set warning tone if the door keeps open for long time .(User can require the time setting when manufacture).For
example , if the door is not closed for more than 30 seconds, the buzzer will issue an on-going long “di” to remind user that
the door is not closed (This function can be only used in private mode.)
User can press button 1 and button 2 at the same time to choose whether need warning function or not.
4Security Function
4.1 Locking of illegal card
•If read the lock with illegal card for 5 times, the system will be locked and use the correct card can read or set.
•In locking condition, if read any card, it will issue "di di di di di" as the alarm sound.
4.2 Low voltage alarm
•4.5V ±0.1V. If read card, the lock will issue “di di di” as the alarm sound.
•4.0V±0.1V. After unlock for the last time, the motor stops working. The lock is open and cannot be closed any
more. User need to change the battery.
4.3 Power saving
If there is no any operation, lock system will enter into sleeping mode after 3seconds.

Installation Instruction Manual
Page 6 of 7 RFID Devices
5Installation
Drawer
Ordinary cabinet door
Sliding cabinet door

ID Lock 1000 Technical Data
HF RFID Reader Page 7 of 7
6Technical Data
Name
Electronic RFID lock
Model
ID Lock 1000
Material
ABS
Size
Lock body (L × W × H): 80 × 80 × 27 mm;
Lock hook (L × W × H): 75 × 27 × 21.5 mm
Weight
200 g (with lock hook)
Battery
DC 6V (4 × 1.5V AAA size)
Driven mode
Motor/servo
Static power consumption
70 µA
Dynamic power consumption
200 mA
Warning voltage
4.5 V
Unlock way
RFID card/ 13.56 Mhz
Response time
Less than 500 ms
Working temperature
-15…+55 °C
Working humidity
5…95 % RH
Working life
Standby mode: 1 year
Test
Salt spray testing 72 hours
Application
Dormitory storage locker; gym cabinet; swimming pool storage locker; drawer
Table of contents
Other iDTRONIC Other manuals
Popular Other manuals by other brands

HBM
HBM MGCplus operating manual

PIRASTRO
PIRASTRO KorfkerRest Model 2 instruction manual

Heath Company
Heath Company Heathkit HD-1410 manual

ADDAC System
ADDAC System ADDAC304 Assembly guide

Plasma Air
Plasma Air PlasmaPURE AutoClean 1500 Installation, operation & maintenance manual

AVO
AVO Turboworld's Bolt-on instructions