[Louver removal/installation procedure]
Louver removal procedure
Louver installation procedure
When installing the louver to the main unit, align and insert the tongue of the
louver into the groove of the main unit. After inserting the tongue into the groove,
turn the louver clockwise to install.
* Do not touch inside the device when removing and installing the louver, otherwise accidents
or problems with operation may occur.
[Discharge needle unit removal/installation procedure]
When using a ultrasonic cleaner for cleaning,
remove the discharge needle unit.
Discharge needle unit removal procedure
Discharge needle unit installation procedure
As shown in the figure above, install the louver and the discharge needle unit so that
the claw of the louver is inserted into the hole of the discharge needle unit. (Note: 3)
Turn the discharge needle unit clockwise until it stops to install.
Notes: 1) If replacing the louver, install the discharge needle unit to the replacement louver.
Notes: 2) When turning the discharge needle unit, do not apply any more force than is necessary,
otherwise the louver or the discharge needle unit may become damaged.
Notes: 3) Confirm the side of the discharge needle unit to install. If installed on the wrong side, the
discharge needle unit or the louver may become damaged.
Option (sold separately)
ER-F12ANT : Discharge needle unit x 1
Cleaning and replacement procedure for fan filter
Install a fi lter in accordance with the operating environment.
Remove the fi lter cover. Disengage the clasps in the places indicated by in the illustration
below, and then pull the fi lter cover in the direction of the arrow to remove it. (Refer to the
illustration below.)
Clean away any dust and dirt adhering to the fi lter. If the fi lter is particularly dirty,
wash it in water. If washing the fi lter in water, let it dry thoroughly before reusing it.
Install the fi lter. Install the fi lter cover.
* If the device is used while the fi lter is still wet, accidents or problems with operation may occur.
* If the fi lter will not come clean, it should be replaced.
* Be careful not to let anything get inside the device while the fi lter is removed.
Option (sold separately)
ER-F12FX5 : Replacement fi lter x 5
Filter cover
Filter cover
Filter
Main unit
Main unit
8TROUBLESHOOTING
Be sure to turn off the power before checking the discharge unit or the fan unit.
Problem Main cause Remedy
Discharge error
indicator (DSC
ERROR)
lights up.
Condensation
Foreign objects
F.G. not connected
• An abnormal discharge is probably occurring.
Turn off the power and check that the tip of the
discharge needle is intact and free from foreign objects,
and also check that the discharge needle unit is
correctly installed to the louver.
• If the error indicator remains lit even after the discharge
needle has been cleaned, check if the area around the
needle is dirty.
• Check that the F.G. terminal is securely grounded.
Fan error indicator
(FAN ERROR)
lights up
.
Fan is covered
Fan is blocked
Foreign objects
• Turn off the power and check that the filter is not dirty or
blocked.
• Check that there are no foreign objects inside the
product.
9SPECIFICATIONS
Type Standard fan type Low-volume fan type
Item Model No. ER-F12 ER-F12S
Charge removal time1sec. approx. (Note 1) 1.5 sec. approx. (Note 1)
Ion balance ±10 V or less (Note 2) ±10 V or less (Note 2)
Power supply voltage 24 V DC ±10% 24 V DC ±10%
Power consumption 700 mA or less 400 mA or less
Discharge method High-frequency AC methodHigh-frequency AC method
Discharge output voltage ±2 kV approx. ±2 kV approx.
Max. fan speed 5.3 m/s (Note 2) 4.0 m/s (Note 2)
Max. fan volume 3.68 m3/min 2.50 m3/min
Error output
NPN transistor/open collector
• Max. sink current: 50 mA
•
Applied voltage: 30 V DC or less (between output terminal and 0 V)
• Residual voltage: 1 V or less (at input current of 50 mA)
Output operation OFF when discharge error or fan error detected
Normally ON
Short-circuit protection
Incorporated
Discharge halt output Discharge halt: Short-circuited to 0 V
Discharge (operation start): Open
Indicators
POWER Green LED (Lights up when power on)
DSC Green LED (Lights up during normal discharge)
DSC ERROR Red LED (Lights up when discharge error detected)
FAN ERRORRed LED (Lights up when fan error detected)
Ozone generation amount 0.04 ppm or less (Note 1)
Pollution level
2
Ambient temperature
0 to + 50°C (No dew condensation) / Storage : -10 to + 65°C
Ambient humidity
35 to 65% RH (No dew condensation) / Storage : 35 to 65% RH
Vibration resistance
10 to 55 Hz frequency, 0.75 mm amplitude in X, Y and Z directions for two hours each
Over-voltage category I
Material Enclosure: ABS Louver: ABS Discharge needle: Tungsten
Discharge needle unit: PBT Bracket: SPHC
Grounding method C (capacitor) grounding
Weight 790g approx. (main unit only)
Accessories
●Louvers ● Caution label: 1 set
Straight louver: 1 (Note 3 ) ● Rubber cushion: 1
Angle louver: 1
Notes: 1) Typical value at 200 mm from directly in front of discharge outlet, fan speed MAX, straight
louver, with no fi lter installed.
Notes: 2) Typical value at 300 mm from directly in front of discharge outlet, fan speed MAX, straight
louver, with no fi lter installed.
Notes: 3) The discharge needle unit is loaded on the straight louver before shipment.
10
CAUTIONS
This product has been developed / produced for industrial use only.
Do not use this product for any purpose other than charge removal and dust removal.
Do not use this product in enviroments which are outside the specification range,
otherwise operating problems or damage may occur. In addition, the operating life
of the product may become significantly reduced.
Never disassemble, repair or modify this product, otherwise operating problems or
accidents may occur.
Do not dispose of this product by burning it, otherwise it may explode or toxic
fumes may be generated.
This product generates ozone, so be sure to provide adequate ventilation if using it
in a confined space.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Be sure to turn off the air and the power supply before carrying out any cable
connection or inspection work. If this is not done, operating problems, damage or
electric shocks may occur.
After connecting the cables, check that the connections are correct before turning on the
power. If the cables are connected incorrectly, operating problems or accidents may occur.
Verify that the supply voltage variation is within the rating.
When using as a CSA and UL compliant product, use a CLASS 2 CSA/UL certified
power supply, or a CSA/UL certified power supply that has been evaluated as a
Limited Power Source as specified in CAN/CSA-C22.2NO.60950-1/UL60950-1.
It takes approximately 5 seconds after the power is turned on before the fan
operation stabilizes. To ensure proper charge removal performance, do not use the
product until sufficient time has elapsed.
Do not turn the power back on immediately after it has been turned off, otherwise
operating problems or accidents may occur. In addition, the operating life of the
product may become significantly reduced. Wait at least 2 seconds before turning
the power back on again.
Do not use any cables which have any damage (such as splitting or cracking),
otherwise operating problems or accidents may occur.
Avoid using the product in places where there are high levels of steam or dust in
the air or where it might be directly exposed to water, oil or welding spatter.
Avoid use at an elevation higher than 2000m, and outdoor use.
Do not touch the discharge needle with hard objects such as tools. If the discharge
needle becomes broken, it will not provide sufficient charge removal performance,
and moreover operating problems or accidents may occur.
Do not use this product while the fi lter is blocked, otherwise accidents or problems
with operation may occur.
Clean or replace the fi lter at regular intervals.
Be sure to turn off the power before replacing the fi lter.
Install the product so that it is at least 100 mm away from the objects being charged.
When installing this product, be sure to securely install the main unit and the
bracket. If they are not securely installed or if constant vibration or shocks are
applied, accidents or problems with operation may occur.
Do not place any objects which may obstruct air fl ow within 20 mm the front of the
fan air intake, otherwise accidents or problems with operation may occur.
Use cables that are 0.15mm2or more and 30 m or less in length for wiring.
Also, keep the wiring as short as possible in order to prevent naise.
If this product ceases functioning or is no longer required, dispose of it according to
appropriate local waste disposal regulations.
11
CSA/UL COMPLIANT PRODUCT
This product complies with CSA and UL standards, and has been certified by TUV SUD.
Open
Turn the louver in the direction
of the arrow. Remove the louver from the main unit.
Groove of the
main unit Tongue of the
louver
Hold the louver and turn the discharge needle
unit counterclockwise. (Note: 2)
Remove the discharge needle unit from the
louver to the direction shown in the figure.
Discharge
needle unit
Louver (Note: 1)
Hole of the discharge
needle unit
Details of the