IFM SmartModul CR2512 Application guide

Device manual
SmartModul
Input/output module
CR2512
80269925 / 00 01 / 2018
UK

SmartModul CR2512
2
Contents
1 Preliminary note � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
2 Safety instructions � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
3 Function and features� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
4 Function � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 4
5 Mounting� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
6 Electrical connection� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 5
7 Set-up � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
7�1 PLC configuration in CODESYS 2�3 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
7�2 PLC configuration in CODESYS 3�5 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
7�2�1 Heartbeat configuration � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
7�2�2 SyncMonitoring � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8
7�3 Electronic Data Sheet� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8
8 Parameter settings � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
8�1 Parameter list � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
9 Technical data� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �11
10 Object directory� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 16
11 Fault correction � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 24
11�1 EMCY Object � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 24
12 Maintenance, repair and disposal� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25
13 Approvals / standards � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25
14 Terms and abbreviations� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 25

UK
SmartModul CR2512
3
1 Preliminary note
Technical data, approvals, accessories and further information at www�ifm�com�
►Instruction
→Cross-reference
Important note
Non-compliance can result in malfunctions or interference�
Information
Supplementary note
2 Safety instructions
This description is part of the unit� It contains texts and drawings concerning the
correct handling of the controller and must be read before installation or use�
Observe the information of the description� Non-observance of the notes, operati-
on which is not in accordance with use as prescribed below, wrong installation or
handling can result in serious harm concerning the safety of persons and plant�
The device may only be installed, connected and commissioned by qualified per-
sonnel�
Disconnect the device externally before doing any work on it� If necessary, also
disconnect separately supplied output load circuits�
In the case of malfunctions or uncertainties please contact the manufacturer�
Tampering with the device can lead to considerable risks for the safety of persons
and plant� It is not permitted and leads to an exclusion of any liability and warranty
claims�
3 Function and features
Das E/A-Modul CR2512 dient zur dezentralen Auswertung von Sensorsignalen
und zur Ansteuerung von Aktoren und Proportionalventilen� Über die integrierte
Strommessung kann der Spulenstrom überwacht und zur Regelung genutzt wer-
den�

SmartModul CR2512
4
4 Function
●The module supports binary inputs and binary/analogue outputs and is there-
fore classified in the device profile "I/O module" to CiA DS 401�
●As regards the input/output functions, the module can be configured and it
supports the following functions:
– binary inputs (can also be used as node ID selector)
– binary outputs with/without current detection; up to 4 A
– PWM outputs with/without current detection; up to 4 A
– current-controlled PWM outputs, up to 4 A
– selectable current measuring range 0���1 A or 0���4 A�
●There are 1 server SDO and the 4 default PDOs to CiA DS 401�
The PDO mapping cannot be changed (static PDO mapping)� The default iden-
tifiers are assigned according to the "predefined connection set"�
●The COB IDs of the PDOs as well as the transmission type (synch / asynch) of
the individual PDOs can be configured�
●The module expects a synch object�
The CAN identifier of the synch object can be configured�
●The module supports "node guarding" and "heartbeat"�
The "guard time",the "life time factor" and the "heartbeat time"can be confi-
gured�
When there are no heartbeat or node guarding signals, the outputs are auto-
matically switched off by the operating system�
●The module generates an emergency object� The COB ID of the EMCY object
can be configured�
●The module stores the last error�
The error code of the corresponding emergency object is stored�
●The module supports a reset function, i�e� assignment of the parameters to the
factory default values (→ 9.1 Parameter list) upon request�

UK
SmartModul CR2512
5
5 Mounting
In order to expose the module to the minimum mechanical stress it should pre-
ferably be mounted horizontally or vertically on the mounting panel� The module
must be fixed with four screws to DIN 7500 or DIN 7984 (M5 x L)�
If possible, the module should be mounted in such a way that the cable entry of
the plug points downwards�
As the self-heating of the electronics of the unit is dissipated via the housing, suffi-
cient cooling must be ensured in case of "sandwich mounting" of modules�
6 Electrical connection
To ensure the protection of the device against electrical interference and the
safe function of the device, the housing must be connected to the ground of
the vehicle�
1: Drill hole for ground connection
►Establish a connection between the device and the ground of the vehicle using
M5 screws�
►To protect the whole system (wiring and module) the individual electric circuits
must be protected�
Designation Potential Pin No. Fuse
Operating voltage sensors/module VBBS23 2 A
Operating voltage outputs VBBO05 15 A

SmartModul CR2512
6
7 Set-up
7.1 PLC configuration in CODESYS 2.3
Parameter setting of the device functions and of the CAN interface is directly done
from the application programmed with CODESYS 2�3� To do so, the "Electronic
Data Sheet" (EDS) is integrated via the CODESYS PLC configuration�
CODESYS dialogue "PLC configuration" (example)
For a description of the setting and application of the "PLC configuration“ dialogue
see the CODESY manual and the CODESYS online help�

UK
SmartModul CR2512
7
7.2 PLC configuration in CODESYS 3.5
The "Electronic Data Sheet“ (EDS) is installed in the [Device Repository]� Proceed
as follows in the main menu:
►Click on [Tools] / [Device Repository]�
►Select [Fieldbuses] / [CiA CANopen] / [CiA Remote Device] and click on [In-
stall]�
►Select EDS file and click on [Open]�
> In CODESYS 3�5 the devices are integrated as CiA remote devices in the de-
vice tree under a [CANopen_Manager] element�
The CANopen communication is configured via the CODESYS configuration
editor�
7.2.1 Heartbeat conguration
The function [Reset Node] must be activated on the tab [General] so that the
device applies the parameters set for heartbeat monitoring of the CANopen
Manager�

SmartModul CR2512
8
7.2.2 SyncMonitoring
To activate the device-internal monitoring of the Sync cycle, the monitoring time
has to be written into the object directory entry 0x1006� This is possible by
supplementing the SDO list in the CANopen configurator or during the operating
time via the function block COP_SDOwrite�
The monitoring time is indicated in microseconds [μs].
7.3 Electronic Data Sheet
The EDS contains the description of all parameters and I/O data of the device in a
format defined by CANopen� The EDS files are provided for all CANopen slaves by
ifm electronic�
The EDS files are available at www�ifm�com�

UK
SmartModul CR2512
9
8 Parameter settings
Automatic saving of the communication and unit parameters can be activated or
deactivated by means of the "save all parameters" entry (see object directory,
index 1010)� When the value 0x02 is entered into SIdx 01, all parameters are auto-
matically saved if changes were made�
With the value 0x00 there is no automatic saving, i�e� changed parameters will only
be valid until the unit is switched off or until the next reset is made�
With the function "restore" (see object directory, index 1011) the parameters (ex-
cept the baud rate and the node ID) can be assigned to the factory default values�
With the next power on they become valid�
Control characteristics (index 2004���7)
The current control behaviour can be parameterised separately for each channel
pair in the P and I values� For each of the 4 output pairs the max� load current [mA]
has to be indicated� By means of this value the respective measuring range (1 A or
4 A) is automatically selected�
Explanation of the abbreviations:
0x���= hexadecimal number
0b���= bit-coded
0d���= decimalnumerical value
str = string
rw = read-write
ro = read only
u8 = unsigned 8 bit
u16 = unsigned 16 bit
u32 = unsigned 32 bit

SmartModul CR2512
10
8.1 Parameter list
Parameter Index in object
directory
Default (factory
preset)
Change
automatically
saved
Change effective
Manufacturer Specific Profile Area; index 2000 to 5FFF
I/O Configuration 2000 binary inputs/outputs adjustable after PreOp
PWM-Frequenz 2001 0x64 (100Hz) adjustable after PreOp
Control parameters
(P/I values, max� current)
Channel 1/2
Channel 3/4
Channel 5/6
Channel 7/8
2004
2005
2006
2007
-
-
-
-
adjustable
adjustable
adjustable
adjustable
after PreOp
after PreOp
after PreOp
after PreOp
Node-ID 20F0, 20F1 0x20 (0d32) yes after a reset
Baud rate 20F2, 20F3 0x04 (125 kBit/s) yes after a reset
Communication Profile Area; Index 1000 to 1FFF
COB-ID Synch Object 1005 0x80 adjustable after a reset
Communication Cycle 1006 0x00 (Off) adjustable immediately
Guard Time 100C 0x00 (Off) adjustable immediately
Life Time Factor 100D 0x00 adjustable immediately
Save Parameter 1010 0x02
(AutoSave ON) yes immediately
COB-ID EMCY 1014 0x80 + Node-ID adjustable after a reset
Consumer Heartbeat time 1016 0x00 (Off) adjustable immediately
Producer Heartbeat time 1017 0x00 (Off) adjustable immediately
COB-ID Rec PDO 1 1400 01 0x200 + Node-ID adjustable after a reset
Trans Type Rec PDO 1 1400 02 0x01 (synchronous) adjustable immediately
COB-ID Rec PDO 2 1401 01 0x300 + Node-ID adjustable after a reset
Trans Type Rec PDO 2 1401 02 0x01 (synchronous) adjustable immediately
COB-ID Trans PDO 1 1800 01 0x180 + Node-ID adjustable after a reset
Trans Type Trans PDO 1 1800 02 0x01 (synchronous) adjustable immediately
Event Timer Trans PDO 1 1800 05 0x00 adjustable immediately
COB-ID Trans PDO 2 1801 01 0x280 + Node-ID einstellbar after a reset
Trans Type Trans PDO 2 1801 02 0x01 (synchronous) adjustable immediately
Event Timer Trans PDO 2 1801 05 0x00 adjustable immediately
The life time factor 0 is interpreted as 1�
The first guard protocol is assessed as "start guarding" even if guarding is not
active at this time (guard time = 0)�

UK
SmartModul CR2512
11
9 Technical data
132
5,5
26
80
15
45°
153
LED
43
±0,5
±1
106,5 ±1
Control systems
\DATEN\100\DB-FORM—PZD/03/12/96
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
06.11.2014
CR2512
SmartModule
I/O module
digital and analogue
for R 360 system
CANopen
interface
Supply voltage
10...32 V DC
We reserve the right to make technical alterations without prior notice. CR2512 / page 1
Technical data 4 digital inputs
8 digital/PMW outputs with integrated current measurement
Housing closed screened metal housing
with flange fastening
Dimensions (l x w x h) 132 x 43 x 153 mm
Installation by means of 4 M5xL screws to DIN 7500 or DIN 7984
mounting position horizontal or vertical to the mounting wall
Connection 55-pin connector, latched, protected against reverse polarity
type AMP housing or Framatome
AMP junior timer contacts, crimp connection 0.5/2.5 mm²
Weight 0.95 kg
Inputs 4
can be configured as digital, for positive sensor signals (low side)
and can be used for selecting the node ID offset
Outputs 8
can be configured as digital, positive-switching (high side)
analogue, PWM channel (PWM value 0 ‰; 50...1000 ‰)
analogue, current-controlled channel (20...1000mA; 80...4000mA)
Switching current per output max. 4 A
(with / without current monitoring)
Total current max. 12 A
Supply voltage UB10...32 V DC
Current consumption ≤50 mA
(without external load at 24 V DC)
Operating temperature – 40...85 °C
Storage temperature – 40...85 °C
Protection IP 67
(for inserted plug with individually sealed cores e.g. EC2084)
Interface CAN interface 2.0 B, ISO 11898
Baud rate 20 Kbits/s...1 Mbit/s
(default setting 125 Kbits/s)
Communication profile CANopen, CiA DS 301 version 4, CiA DS 401 version 2.1
Node ID (default) hex 20 (= dec 32)
Status LED two-colour LED (red/green)

SmartModul CR2512
12
CR2512 Operating status
Status LED
Test standards and regulations
Climatic test Moisture/heat to EN 60068-2-30, test Db
(≤95% rel. humidity, non-condensing)
salt mist test to EN 60068-2-52, test Kb, severity level 3
protection test to EN 60529
Mechanical resistance vibration to EN 60068-2-6, test Fc
shock to EN 60068-2-27, test Ea
bump to EN 60068-2-29, test Eb
Immunity to to ISO 7637-2, pulses 2a, 3a, 3b, severity level 4, function state A
conducted interference to ISO 7637-2, pulse 5, severity level 4, function state B
to ISO 7637-2, pulse 1, 2b, severity level 4, function state C
Immunity to interfering fields according to UN/ECE-R10 at 100 V/m (E1 type approval)
and EN 61000-6-2 (CE)
Interference emission according to UN/ECE-R10 (E1 type approval)
and EN 61000-6-4 (CE)
Control systems
\DATEN\100\DB-FORM—PZD/03/12/96
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
06.11.2014We reserve the right to make technical alterations without prior notice. CR2512 / page 2
LED Status Description
green OFF no supply voltage
ON module in stand-by mode
CANopen status: PREOPERATIONAL / PREPARED
outputs = OFF
1.0 Hz At least one input was configured as node ID selector.
After power on LED flashes n times according to the set
node ID offset.
Then the module changes into the CANopen status
PREOPERATIONAL
2.0 Hz module active
CANopen status: OPERATIONAL
outputs are updated
red OFF communication OK
ON communication disturbed
• node guard / heartbeat error
(if node guarding/heartbeat is activated)
• no synch objects
(if synch monitoring is activated)
During the start-up or reset of the controller
the green and the red LEDs light simultaneously.
This appears as orange.

UK
SmartModul CR2512
13
CR2512 Characteristics of the inputs/outputs
Outputs ■Semi-conductor outputs (high side), short-circuit and overload protection
Channels 1...8 switching voltage 10...32 V DC
can be configured as ... switching current max. 4 A (with/without current monitoring)
total current max. 16 A
The current measurement of 2 channels each can be selected by means of the wire
connections. The following channels are combined: 1+2, 3+4, 5+6, 7+8.
■PWM outputs
Two outputs each are combined (1+2, 3+4, 5+6, 7+8).
The output signal is present at only one of the two outputs while the other output is
OFF (e.g. left/right or up/down functions).
It is possible to immediately switch over from one output to the other.
PWM frequency 20...250 Hz
pulse/break ratio 0 ‰; 50...1000 ‰
resolution 1 ‰
switching current max. 4 A (referred to PWM value 1000‰)
With smaller PWM values this current value is reduced.
value range -1000...+1000 ‰
Values > +1000‰ are internally rounded to +1000 ‰.
Values < -1000‰ are internally rounded to -1000‰.
With the values between -50...+50 ‰ the output is switched off.
value output +50...+1000‰ are present at the odd-numbered outputs
(channels 1, 3, 5, 7)
-1000...-50‰ are present at the even-numbered outputs
(channels 2, 4, 6, 8)
■Current outputs
With the configuration as "current-controlled output" two outputs each are
combined (1+2, 3+4, 5+6, 7+8).
PWM frequency 20...250 Hz
control range 20...1000 mA / 80...4000 mA (see control parameters)
control characteristics can be set via the object directory (see control parameters)
setting resolution 1 mA
precision ± 2% FS
switching current max. 4 A
load resistance min. 3/12 Ω(at UB= 12 V DC)
min. 6/24 Ω(at UB= 24 V DC)
value range -4000...+4000 mA
Values > +4000 mA are rounded to +4000mA.
Values < -4000 mA are rounded to -4000mA.
Values -80...+80 mA are interpreted as "OFF".
value output 80...4000 mA are present at the odd-numbered channels
(1, 3, 5, 7)
-4000...-80 mA are present at the even-numbered channels
(2, 4, 6, 8)
Digital and PWM/current output can be combined to one connection pair, i.e. one
output acts as binary, the other output as PWM/current output.
The outputs can then be switched separately from each other.
Control parameters By indicating the max. load current [mA] for each output pair the respective control or
value range (1000 or 4000mA) is selected automatically.
In addition the P/I behaviour of the current control function for each output pair can
be parameterised.
Free-wheel diode is integrated! To avoid a falsification of the measuring result, no external free-wheel diode must be
connected in parallel with the load in the "current-controlled output" operating mode.
Inputs ■Binary inputs, for positive sensor signals (low side)
Channels 9...12 switch-on level 0.4...0.7 UB
can be configured as ... switch-off level 0.2...0.24 UB
input resistance 3 kΩ
input frequency 50 Hz
■Node ID selector
Each input can be allotted a value between 20and 23. The resulting numerical value
is added to the basic node ID according to the input and the value.
If inputs are configured as node ID selector, the module does not go into the PRE-
OPERATIONAL status after switch-on before a valid signal (”0” or ”1”) has been
present at the selector inputs for at least 500ms and the resulting node ID has been
received.
It must be possible to clearly assign the value of the node ID selector to the inputs,
i.e. the inputs must have different values!
Control systems
\DATEN\100\DB-FORM—PZD/03/12/96
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
06.11.2014We reserve the right to make technical alterations without prior notice. CR2512 / page 3

SmartModul CR2512
14
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
06.11.2014We reserve the right to make technical alterations without prior notice. CR2512 / page 4
Supply
Output
CAN
Interface
23
01
05
02
38
20
08
50
15
14
32
33
51
03
39
21
27
04
40
22
09
25
41
42
28
16
52
34
10
17
53
35
29
18
54
36
11
19
55
37
30
06
47
43
Input
07
48
44
24
49
45
26
31
46
Abbreviations
CANH= CAN interface (high)
CANL= CAN interface (low)
GNDO= GND (output)
GNDS= GND (sensors/module)
PWM = output for pulse-width modulated signals
VBBO= supply voltage (output)
VBBS= supply voltage (sensors/module)
CR2512 Wiring

UK
SmartModul CR2512
15
Control systems
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
06.11.2014We reserve the right to make technical alterations without prior notice. CR2512 / page 5
02
38
20
08
Channel 1
OUT
Current
GND
VBB
O
VBB
S
GND
S
1
1
+VBB
O
03
39
21
27
OUT
Current
GND
2
2
+VBB
O
Channel 2
02
38
20
08
OUT
Current
GND
VBB
O
VBB
S
GND
S
1
1
+VBB
O
03
39
21
27
OUT
Current
GND
2
2
+VBB
O
02
38
20
08
OUT
Current
GND
VBB
O
VBB
S
GND
S
1
1
+VBB
O
03
39
21
27
OUT
Current
GND
2
2
+VBB
O
Channel 1
Channel 2
Channel 1
Channel 2
CR2512 Configuration examples (outputs channel pair 1/2)
Example 1
Example 2
Example 3
digital
e.g. two-way valves
digital
e.g. two-way valves
with current monitoring
PWM or current-controlled
e.g. proportional valve
digital
e.g. two-way valves
PWM or current-controlled
e.g. proportional valve
output functions

SmartModul CR2512
16
10 Object directory
Manufacturer Specific Profile Area; index 2000 to 5FFF
Index S-Idx Name Typ Default Beschreibung
2000 0 I/O Configuration u8, ro 0x0C Number of the entries
(= number of the output channels)
2000 1 Configuration
channel 1 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 2 Configuration
channel 2 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 3 Configuration
channel 3 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 4 Configuration
channel 4 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 5 Configuration
channel 5 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 6 Configuration
channel 6 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 7 Configuration
channel 7 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
2000 8 Configuration
channel 8 (output) u8, rw 0x02
0 = OFF
2 = binary output
4 = analogue output (PWM)
5 = analogue output (current-controlled)
Explanation of the abbreviations:
0x���= hexadecimal number
0b���= bit-coded
0d���= decimal numerical
str = string
rw = read-write
ro = read only
u8 = unsigned 8 bit
u16 = unsigned 16 bit
u32 = unsigned 32 bit

UK
SmartModul CR2512
17
Index S-Idx Designation Type Default Description
2000 9
Configuration
channel 9
(input 1)
u8, rw 0x01
0 = disabled
1 = binary input
100 = Node-ID-selector, value 20= 1
101 = Node-ID-selector, value 21= 2
102 = Node-ID-selector, value 22= 4
103 = Node-ID-selector, value 23= 8
2000 10
Configuration
channel 10
(input 2)
u8, rw 0x01
0 = disabled
1 = binary input
100 = Node-ID-selector, value 20= 1
101 = Node-ID-selector, value 21= 2
102 = Node-ID-selector, value 22= 4
103 = Node-ID-selector, value 23= 8
2000 11
Configuration
channel 11
(input 3)
u8, rw 0x01
0 = disabled
1 = binary input
100 = Node-ID-selector, value 20 = 1
101 = Node-ID-selector, value 21= 2
102 = Node-ID-selector, value 22 = 4
103 = Node-ID-selector, value 23= 8
2000 12
Configuration
channel 12
(input 4)
u8, rw 0x01
0 = disabled
1 = binary input
100 = Node-ID-selector, value 20 = 1
101 = Node-ID-selector, value 21= 2
102 = Node-ID-selector, value 22 = 4
103 = Node-ID-selector, value 23= 8
If several inputs are configured as node ID selector, different values have to be assigned!
2001 0 PWM
Frequency u8, rw 0x64
(100 Hz)
Setting in Hz (20���250 Hz)
If an invalid value is entered, the previ-
ous value remains valid�
2002 0 Actual current
values u8, ro 0x04
Number of the entries
(= number of the current measuring
channels)
2002 1 Current values
channel 1, 2 u8, ro – Actual current value in mA
2002 2 Current values
channel 3, 4 u8, ro – Actual current value in mA
2002 3 Current values
channel 5, 6 u8, ro – Actual current value in mA
2002 4 Current values
channel 7, 8 u8, ro – Actual current value in mA
2004 0 Control parame-
ters channel 1, 2 u8, ro 0x03 Number of the entries
(= number of the control parameters)
2004 1 P value channel
1, 2 u8, rw 0x32
P value of the current control function
channel 1, 2 (= value in % referred to the
presetactual value difference)
2004 2 I value channel
1, 2 u8, rw 0x14
I value of the current control function
channel 1, 2 (= value in % referred to the
presetactual value difference)

SmartModul CR2512
18
Index S-Idx Designation Type Default Description
2004 3 max� current
channel 1, 2 u16, rw 0xFA0 max� possible load current in mA (=
current at 1000‰ PWM)
2005 0 Control parame-
ters channel 3, 4 u8, ro 0x03 Number of the entries
(= number of the control parameters)
2005 1 P-Anteil Kanal
3, 4 u8, rw 0x32
P value of the current control function
channel 3, 4 (= value in % referred to the
presetactual value difference)
2005 2 I value channel
3, 4 u8, rw 0x14
I value of the current control function
channel 3, 4 (= value in % referred to the
presetactual value difference)
2005 3 max� current
channel 3, 4 u16, rw 0xFA0 max� possible load current in mA
(= current at 1000‰ PWM)
2006 0 Control parame-
ters channel 5, 6 u8, ro 0x03 Number of the entries
(= number of the control parameters)
2006 1 P value channel
5, 6 u8, rw 0x32
P value of the current control function
channel 5, 6 (= value in % referred to the
presetactual value difference)
2006 2 I value channel
5, 6 u8, rw 0x14
I value of the current control function
channel 5, 6 (= value in % referred to the
presetactual value difference)
2006 3 max� current
channel 5, 6 u16, rw 0xFA0 max� possible load current in mA (=
current at 1000‰ PWM)
2007 0 Control parame-
ters channel 7, 8 u8, ro 0x03 Number of the entries
(= number of the control parameters)
2007 1 P value channel
7, 8 u8, rw 0x32
P value of the current control function
channel 7, 8 (= value in % referred to the
presetactual value difference)
2007 2 I value channel
7, 8 u8, rw 0x14
I value of the current control function
channel 7, 8 (= value in % referred to the
presetactual value difference)
2007 3 max� current
channel 7, 8 u16, rw 0xFA0 max� possible load current in mA (=
current at 1000‰ PWM)
20F0
20F1 0Setting of the
Node ID u8, rw 0x20
(= 0d32)
The node ID used to access the module
in the CANopen network�
20F2
20F3 0Setting of the
Baud rate u8, rw 0x04
Baud rate of the CAN network
0 = 1000 kBaud
1 = 800 kBaud
2 = 500 kBaud
3 = 250 kBaud
4 = 125 kBaud (default)
5 = 100 kBaud
6 = 50 kBaud
7 = 20 kBaud
The entries 20F0/20F1 and 20F2/20F3 must always contain identical values� The new entries are valid after
a reset (switching the module off/on)�
Values outside the permissible ranges will be rejected�

UK
SmartModul CR2512
19
Communication Profile Area; index 1000 to 1FFF
Index S-Idx Designation Type Default Description
1000 0 Device type u32, ro 0x000B0191 Profile 401;
Inputs and outputs, binary and analogue
1001 0 Error register u8, ro 0x00
Bit-coded to profile 301, the following is
supported:
0b 0000 0000 no error
0b 0000 0001 generic error
0b 0001 0000 communication error
0b 1000 0000 manufacturer specific
1003 0 Pre-defined
errorfield u8, ro 0x02 An error list with 1 entry is supported�
1003 1 Error history u64, ro 0x00
Error occured, coded according to
the EMCY list, the last error is in the
subindex 1�
1005 0 COB-ID
synch objekt u32, rw 0x00000080
- Module generates no synch message
(bit 30 = 0)
- 11-bit identifier system (bit 29 = 0)
- Identifier of the synch message
1006 0 Communic�
Cycle u32, rw 0x00000000 Max� time between 2 synch objects in
µs Useful resolution = 1ms
1008 0 Device name str, ro CR2512 Device name
1009 0 HW Version str, ro x�x Hardware version
100A 0 SW Version str, ro x�x Software version
100C 0 Guard time u16, rw 0x0000
Time in ms
Within this time the output module ex-
pects a "node guarding" of the network
master�
If the value 0 is entered here, this func-
tion is not supported� Note:
Node monitoring with "node guarding"
or "heartbeat" can only to be used as an
alternative�
100D 0 Life time factor u8, rw 0x00
If no "node guarding" is received for
"guard time" x "life time", the module
switches the outputs off�
The module changes the CANopen
status to PREOP�
The result from "guard time" x "life time"
must be between 0 and 65535�
1010 0 Number of save-
options u8, ro 0x01 Number of the "save" options
1010 1 "Save all para-
meters” u32, rw 0x02
Automatic saving of all changed para-
meters OFF/ON�
0 = AutoSave OFF
2 = AutoSave ON

SmartModul CR2512
20
Index S-Idx Designation Type Default Description
1011 0 Number of
restore-options u8, ro 0x01 Number of the "restore" options
1011 1 "reset for all
parameters” u32, rw 0x01
If the string "load" is entered here, the
parameters are assigned to the factory
default values and are valid after the
next reset�
1014 0 COB-ID
Emergency u32, rw 0x00000080
+ Node-ID
- EMCY is valid (Bit 31 = 1)
- EMCY is not valid (Bit 31 = 0)
In default setting the EMCY
transfer is deactivated�
- 11 Bit ID (Bit 29 = 0)
- ID = 0x80 + Node-ID
CAN-Identifier can be change by the
user�
1016 0
Number of op-
tions Consumer
heartbeat time
u8, ro 0x01 Number of the monitored units
1016 1 Consumer heart-
beat time u32, rw 0x00
Heartbeat monitoring time for node
n� Monitoring of only one node is
supported�
0x0nntttt = monitoring time [ms]
0x0nntttt = node number
(If nn or tttt = 0, no monitoring is carried
out)
Note:
Node monitoring with "node guarding"
or "heartbeat" is only to be used as an
alternative�
1017 0 Producer heart-
beat time u16, rw 0x00 Time interval [ms] where the inclination
sensor generates a producer heartbeat�
1018 0 Number of iden-
tity objects u8, ro 0x01 Device identification
1018 1 Vendor-ID u32, ro 0x0069666D Vendor ID to CiA specification
1200 0 Server SDOs u8, ro 0x02 Number of the entries
1200 1 COB-ID
Rec SDO u32, ro 0x600 +
Node-ID
- SDO ist gültig (Bit 31 = 0)
- CAN-ID des Receive SDOs
1017 2 COB-ID
Trans SDO u32, ro 0x580 +
Node-ID
-SDO is valid (bit 31 = 0)
-CAN ID of the transmit SDO
1400 0 Receive PDO 1 u8, ro 0x02 Number of the entries Rec PDO 1
Binary outputs
1400 1 COB-ID PDO 1 u32, rw 0x200 +
Node-ID
-PDO is valid (bit 31 = 0)
-CAN ID of the 1st Rec PDOs
Table of contents
Other IFM I/O System manuals

IFM
IFM AL1352 User manual

IFM
IFM AL4103 User manual

IFM
IFM CR2016 Application guide

IFM
IFM ioControl CR2050 Application guide

IFM
IFM CompactModule Metal CR2031 Application guide

IFM
IFM DSU100 User manual

IFM
IFM AL4042 User manual

IFM
IFM AL19 Series User manual

IFM
IFM AL1950 Application guide

IFM
IFM Ecomat 100 CR2011 Application guide
Popular I/O System manuals by other brands

Rockwell Automation
Rockwell Automation FLEX 1794-TB2 installation instructions

ACT
ACT ACTPRO IOM Installation and configuration instructions

Wenglor
Wenglor EFBL001 operating instructions

Diamond Systems
Diamond Systems DS-MPE-GE210 quick start guide

Johnson Controls
Johnson Controls IOM2721 installation guide

M-system
M-system R3-PC16A instruction manual