Ikegami DA-14 User manual

Instruction Manual
IKEGAMI
Amplifiers
Thank you very much for purchasing one of our amplifiers. Please read
this manual before using the amplifier. When using this product, always
follow the instructions contained in this manual, and pay attention to the
safety information.
37 Brook Avenue Maywood,NJ07607 TEL: (201)368-9171 Fax: (201)569-1626 Web:www.ikegami.com
DA-14 DA-16
DA-26 DA-43A
DA-112 DA-1200
DA-3400 DA-6200
MDS-14

WARNING!
Do not expose this product to water, rain or moisture.
Doing this can result in electric shock or fire.
Never take this product apart or try to modify it.
Doing so is very dangerous and could result in electric shock.
Do not store this product near open flame.
Do not use this product near open flame or place lit or flammable items, such as candles,
incense, ect., on it.
Do not place any containers filled with water or other liquids near this product.
Doing so could result in fire or electric shock if the liquid spills and enters the product or gets
it wet. If a liquid spills near this product, unplug the product immediately.
Do not remove or insert the power supply with wet hands.
Doing so could result in electric shock.
Do not use the power supply in any of the following ways. Doing so could result in fire
or electric shock.
Modifying or heating the power cable
Damaging the power cable
Bending or tugging on the power cable unnecessarily
Knotting or kinking the power cable
setting heavy objects on the power cable
When moving this product , first unplug the power supply from the outlet. Do not tug
the cable or move this product with the power supply plugged into the outlet.
Doing so could damage the cable, possibly resulting in fire or electric shock.
To reduce the risk of electric shock, do not remove the cover.
No parts inside the product can be serviced by the user. If your product needs service contact
Ikegami Electronics (U.S.A.) Inc. at (201)368-9171
Usage Environment
Avoid using or storing this product in areas such as those listed below. Doing so could
damage the product or cause it to malfunction.
Areas exposed it heat or flames
Humid areas and areas where water is used
Handling this product
Do not drop or apply a strong force to this product or any included or connected parts.
Do not spill liquids around or inside this product or drop flammable objects around or
inside it.
Power Supply
Only use the supplied power supply which is designed specifically for this product.
Do not allow the plug to come into contact with metal or water.
This Product is not designed for contact medical use
Do not use this product for medical applications that could result in patient contact.
37 Brook Avenue Maywood, NJ 07607 TEL: (201)368-9171 Fax: (201)569-1626 Web: www.ikegami.com

37 Brook Avenue Maywood, NJ 07607 TEL: (201)368-9171 Fax: (201)569-1626 Web: www.ikegami.com
This manual covers the DA-43 family, the DA-43, DA-26 and the DA-112. It also covers the DA-14/16
family and the DA-3400 series distribution amplifiers.
Connections:
POWER
12-18VDC
UNGND ED.
MA DE I N USA
INPUT
INPUT
INPUT
INPUT
V IDEO
SOU R CE
DA-43/DA-4300 (One channel shown used)
Any unused inputs and outputs can be left open and unterminated and will not affect the other signals being
fed in and out of the unit.
POWER
12-18VDC
UNGND ED.
MA DE I N US A
INPUT
INPUT
DA-26, DA-6200 ( 4 of 6 outputs used only)

d) Reinstall the cover and connect the power.
To Install a BNC connector on the CAT-5 cable:
1
p
air from CAT-5 cable
Push and crimp
Placement in system: The DA-43A should be placed as near the end of a system as possible.
1) Disconnect the feed from the camera at the end by the monitor, switcher or VCR. Connect the camera
feed to DA-43A
2) input. Connect one output to your Monitor, switcher or VCR. and verify that the hum is reduced or
eliminated.
3) Adjust the front panel video gain for the desired level
75 ohm Coax
100 ohm UTP CAT-5
There is one suitcase jumper located behind each input BNC
Suitcase Jumper Positioning
DA-43A
Setup options for suitcase jumper

37 Brook Avenue Maywood, NJ 07607 TEL: (201)368-9171 Fax: (201)569-1626 Web: www.ikegami.com
The DA-26/DA-6200 has 2 one in and 6 out amplifiers. The unused input and outputs can be left open and
unterminated with no affect on the signals on the other channels.
POWER
12-18VDC
UNGND ED.
MADEIN USA
INPUT
DA-112/DA-1200 (7 of 12 outputs shown used)
Trouble shooting: The input stage of the DA-43 series distribution amplifiers is a differential type. This
is used to minimize the potential for ground loops. This does not mean that there will not be ground loops in
the system. The outputs to the monitors are all common and can create ground loop problems. The ground
difference between the camera and the DA can be so great as to overcome the differential amplifiers
capabilities.
If a ground loop condition occurs: Disconnect all of the outputs of the DA except one. If the groundloop goes
away and you get a clear picture, your problem is between the monitors and not the camera to DA feed. If the
groundloop problem still exists with only one monitor, the Camera side groundloop problem is severe and a
hum bucking transformer is recommended.
To solve the monitor side groundloop problem:
Most of the time the problem is on the cable that connects the furthest point. When testing for monitor side
ground loops, leave this cable for last. Begin by connecting the closest monitor to a DA output. Then add a
second monitor and check for ground loops. If there are none, disconnect the second cable, mark it as good
and connect another monitor and again check for any problems. Continue checking each cable until all of the
individual monitors have been checked. Now reconnect all of the monitors, one at a time and watch for the
ground loop problem to appear. Usually you will find that the problem is caused by one feed only and
by using a DA-20 or a Hum bucking transformer at the monitor location, the problem will go away.

37 Brook Avenue Maywood, NJ 07607 TEL: (201)368-9171 Fax: (201)569-1626 Web: www.ikegami.com
MDS-14/16 Series
WARNING! The DC power cannot be the from the same supply as the DC camera or video source. It must
be from an isolated source. For units that can work with a common DC source use the MDS-12.
+12VDC (WIRE WITH WHITE TRACE)
GND (WIRE WITH NO TRACE)
DA-14/16 Series:
The DA-14 and the DA-16 are 1 in and 4 out for the DA-14 and 1 in and 6 out for the DA-16. These DA's
have a standard input terminated in 75 ohms. Any unused outputs can be left unterminated.

Limited Warranty:
Ikegami Electronics warrants this product and all accessories provided with it to be free ofdefects
in material and workmanship for a period of 5 years after the original date of purchase. This
warranty does not cover damage to the product resulting from accident, misuse or
modification.
How the warranty works
If this product, or any of the accessories supplied with it, become defective within the
warrantyperiod, Ikegami Electronics (USA) Inc.will at its discretion repair, or replace the
product with an equivalent unit of equal or higher value without charge. Overland return
transportation from Ikegami Electronics (USA) Inc.. to the user is free ofcharge.
How to get service
Please contact Ikegami byphone for return authorization number and then return the defective unit,
transportation prepaid and a dated proof of purchase to:
Ikegami Electronics (USA) Inc.
37 Brook Avenue
Maywood, NJ07607
Obtaining Technical Help/Service
Web Site: www.ikegami.com
Phone: (201) 368-9171
Fax: (201) 569-1626
In no event shall Ikegami Electronics.be liable for Consequential Damages.
Some states do not allow exclusion or limitation of incidental or consequential damages, so the above
limitation may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
37 Brook Avenue Maywood, NJ 07607 TEL: (201)368-9171 Fax: (201)569-1626 Web: www.ikegami.com
This manual suits for next models
8
Table of contents