impro IMPROX DBV User manual

MODEL NUMBER: XDB902-1-0-GB-XX
XDB903-1-0-GB-XX
IMPROXDBV
ImproX (DBv) Vertical Mount Drop Box
INSTALLATION MANUAL
SPECIFICATIONS
Read/Write Capability..................
Impro Tags: All standard ImproX Credit Card
Tags, with or without the slot and clip.
Third-party Tags: Read only capabilities on
selected third-party Credit Card Tags.
Working Environment
XDB902-1-0-GB-XX...............
Mounted in a suitably rated, user supplied
cabinet; the Drop Box is designed to work in
an indoor or outdoor environment similar to
IP54.
XDB903-1-0-GB-XX...............
The Drop Box is designed to work in an indoor
or outdoor environment similar to IP66.
Input Voltage................................
12 V DC, polarity sensitive.
Power Requirements
Current (mA)
Power (W)
Input Voltage 12 V DC
Solenoid OFF.........................
45
0.54
Input Voltage 12 V DC
Solenoid ON...........................
800
9.60
Solenoid
Input Voltage..........................
12 V DC.
Type.......................................
Push, pull action.
Relays
Relay Output..........................
2 Relays each with NO, COM and NC
contacts.
Relay Allocation
Relay 1 ...........................
Factory configured to drive the Solenoid when
a Tag is inserted and read inside the Drop
Box.
Relay 2 ...........................
User configured to control hardware at the exit
point (typically a boom, vehicle gate or
turnstile).

XDB300-0-0-GB-04
December 2007
Page 2
Relays (Continued)
Relay Contact Ratings ...........
3 A at 24 V DC or 125 V AC.
1.5 A at 220 V AC.
Digital Inputs
Type ......................................
4 Dry-contact inputs.
Protection Range ...................
+50 V to -50 V continuous,
+80 V to -80 V surge.
LED “Diagnostic Indicators”
Status LED
Power On........................
Continuous Red.
Upgrade Mode................
Flashing Red (Steady).
RS485 Communications
Failure.....................................
Flashing Red (Intermittent).
Incoming RS485 Data............
Flashing Green LED.
Outgoing RS485 Data............
Flashing Red LED.
Digital Inputs (1-4)..................
Continuous Green on detected contact
closure.
Relays (1 and 2).....................
Continuous Red on activation of the Relay.
Blank Space

XDB300-0-0-GB-04
December 2007
Page 3
INSTALLATION INFORMATION
Accessories
Find the following when unpacking the ImproX DBv:
NOTE: The ImproX TD included in the construction of the ImproX DBv uses the
standard ImproX TT Hardware, with modified Firmware. The ImproX TD will
NOT, however, operate as an ImproX TT.
XDB902-1-0-GB-XX
NOTE: This version of the Drop Box does NOT include a Tag Retention Box for
catching the Tags.
An ImproX Vertical Mount Drop Box with an open frame construction. The Drop
Box includes a 1 m (7 ft) twisted, black, 0.5 mm, 2-Conductor Power Cable.
A Mechanical Drilling and Cutting Template.
Two Fixed Address Labels.
XDB903-1-0-GB-XX
An ImproX Vertical Mount Drop Box with a white powder coated mild steel
Cabinet. The Drop Box Cabinets design includes a Tag Retention Box for
catching the Tags. The Drop Box Throat Assembly includes a 1 m (7 ft) twisted,
black, 0.5 mm, 2-Conductor Power Cable.
One mild steel Mounting Bracket.
Two Keys.
Two PG7 Plastic Cable Glands.
One M10 Rawl Bolt.
Two Fixed Address Labels.
General
Remember the following when installing the ImproX DBv:
Communications Distance
The RS485 communications distance between the ImproX Controller and the LAST
ImproX unit in a cable run, MUST NOT exceed 1 km (1 090 yd). Achieve this by using
good quality screened, twisted 2-pair cable, with the screen EARTHED at one end.
Jumper Links
Long transmission lines or multiple “star” connections, may cause communication
problems. Placing a Jumper Link across the jumper [TR1] in the LAST UNIT AT THE
END OF THE CABLE RUN should solve the problem.
EARTH Connection
Connect the Drop Box to a good EARTH point. Using the RS485 Port, connect the
EARTH Lead to the „ ‟ Terminal. Mains EARTH can be used, but electrical noise
may exist.

XDB300-0-0-GB-04
December 2007
Page 4
Drop Box Connection
Distance between Drop Boxes
To avoid mutual interference, install the Drop Boxes alongside each other at least
500 mm (20 in) apart.
Antenna Reader Connection
Antenna Reader Distance
As the Drop Box makes use of the connections to “Reader 1”, “Reader 2”is available
for connection to any ONE of the available Antenna Readers.
The ideal cable distance between the Drop Box and its Antenna Reader ranges
between 2 m to 16 m (7 ft to 53 ft). Achieve this by using good quality screened,
twisted pair cable.
Distance between the Antenna Reader and the Drop Box
To avoid mutual interference, install the Antenna Reader and the Drop Box alongside
each other at least 150 mm (6 in) apart.
Distance between Antenna Readers from DIFFERENT Drop Boxes
To avoid mutual interference, install the Antenna Readers alongside each other at least
500 mm (20 in) apart.
Arc Suppression
Snubber devices are recommended for EMF Flyback and Arc Suppression when
driving an inductive load with the Relay, see Figure 1.
Figure 1: EMF Flyback and Arc Suppression
Blank Space

XDB300-0-0-GB-04
December 2007
Page 5
Mounting the Drop Box
CAUTION: Make certain that you mount the Drop Box on a vibration-free
surface.
NOTE: The Drop Box can be mounted against virtually any surface, including metal,
a maximum of 25 mm (0.98 in) thick.
XDB902-1-0-GB-XX
Mount the Drop Box against the side of a counter taking into consideration any security
issues, accessibility, routing of wires and visibility of the “Diagnostic Indicators”.The
Front Mouth Plate is mounted on the outside of the counter and the Throat Assembly is
mounted on the inside of the counter.
CAUTION: Make allowance, during installation, for the Tag Retention Box.
Ensure that the Tag Retention Box does NOT restrict the Tags from
dropping out of the Drop Box.
Figure 2: Sequence of Assembly
1. Mark out, drill and cut according to the indications on the Mechanical Drilling and
Cutting Template.
2. Connect the Drop Box as per Figure 4.
3. Place the Front Mouth Plate into position, using the Locating Pins on the back of
the Front Mouth Plate for correct location.
4. Slide the Throat Assembly from inside the counter onto the two Locating Pins, and
tighten using the Wing Nuts supplied.

XDB300-0-0-GB-04
December 2007
Page 6
XDB903-1-0-GB-XX
Mount the Drop Box in a suitable location on a cement slab. Take into consideration
any security issues, accessibility, routing of wires and visibility of the “Diagnostic
Indicators”.
Figure 3: Tag Retention Box Position
1. Position the Mounting Bracket inside the base of the Drop Box.
2. Mark out and drill the mounting hole.
3. Fix the Drop Box into position (using the Mounting Bracket and M10 Rawl Bolt).
4. Remove the Face Plate Assembly (including the Throat Assembly).
5. Connect the Drop Box as per Figure 4.
6. Re-attach the Face Plate Assembly.
7. Hang the Tag Retention Box in position 1 (see Figure 3) below the Throat
Assembly.
8. Mark out and drill two suitable holes for the Power Cable and Comms Cable.
9. Seal the Power Cable Hole and Comms Cable Hole using the supplied PG7 Cable
Glands.

XDB300-0-0-GB-04
December 2007
Page 7
Emptying the Tag Retention Box
1. Unlock the Tag Retention Cabinet.
2. Lift the Tag Retention Box off the lip located at position 1 (see Figure 3).
3. Turn the Tag Retention Box so that the lip faces away from the open Cabinet door.
4. Hang the Tag Retention Box on the lip located at position 2 (see Figure 3).
5. Empty the Tag Retention Box and return the Box back to position 1 (see Figure 3).
6. Lock the Tag Retention Cabinet.
Blank Space

XDB300-0-0-GB-04
December 2007
Page 9
Fixed Address Label
Once the ImproX DBv is installed, sketch a rough site plan. Attach the loose (additional
Fixed Address Labels packaged with the Drop Box) Fixed Address Labels in the
position of the Drop Box on the sketched site plan. When the system installation is
complete and all the units are represented on the site plan by their Fixed Address
Labels, file the site plan for future reference.
GUARANTEE OR WARRANTY
This product conforms to our Guarantee or Warranty details placed on our Web Site, to
read further please go to www.impro.net.
USER NOTES

XDB300-0-0-GB-04
December 2007
Page 10
USER NOTES

XDB300-0-0-GB-04
December 2007
Page 11
USER NOTES

XDB300-0-0-GB-04
December 2007
Page 12
USER NOTES
This manual is applicable to the ImproX (DBv) Vertical Mount Drop Box,
XDB902-1-0-GB-02 and XDB903-1-0-GB-01.
(The last two digits of the Impro stock code indicate the issue status of the product).
XDB300-0-0-GB-04
Issue 05
Dec
2007
ImproX DBv\English Manuals\LATEST ISSUE
\ImprXDBv-insm-en-05.docx
This manual suits for next models
2
Table of contents