documentno.:X1-25_4.pdf
NDTFilm Processorstype:
produced byColenta
Tobe used to process all standardNDTFilms.
PRE-INSTALLATIONMANUAL
NDT FILM PROCESSOR
01/2013 TK
IndustrexM43ic

page2/9
documentno.:X1-25_4.pdf
NDT- Filmprocessor
Theprocessorisdesigned insuchawaythat onlya coldwatersupply, drainandpowerconnectionare
necessary.Theplumbingiscarriedoutaccordingto DIN1986/1988andmustcomplywithlocalplumbing
codes.Thecoldwatersupplymusthaveashut-offvalve/tapsystemconnectedwitha¾“outlet(washing
machineconnection)to theprocessor.
Makesurethatthe watersupplytap isalwaysaccessableasitmustbeopenedbeforeworkandclosed
afterwork.Bymeansofthepressure/flowregulator(integratedintothewatersolenoidvalveofthe
processor)theflowrateis controlledto2.5Lt/min assumingawatersupplypressureof0.3-10bar.
Itis recommendedtoinstallasecond watersupplyoutlet(withshut-offtap)andwithapprox.2.5mtr/8ftof
hoseforrackcleaningpurposes.
The draintubesofthe processorcanbedrainedseparatelyortogether,accordingtolocalregulations
andhealth/safetyrequirements.Thehoseconnectionsfromthe processortothe outlet (drain)are
enclosed.The fixer canbecollectedseparatelyinaplastic container(storagetank)ordirectlyconnected
toasilverrecoveryunit.The developer overflow can becollectedinaplastic container.Inordertoavoid
abackwash ofthedrained,usedchemicals,thedrainhosesshouldbefree ofbendsandwithaconstant
fall.Thedrainmustbe correctlyventilated!
Afloororwalldrainmaybeusedwhich should includeanantisyphonsystem.
Note:Donotusebrassorcopperin the drainlines.
Theminimumdiameterofthedrainlinesshouldbe 40mm.
Electrical:
Foroperation,aseperate 16Ampfusedsocketwithearthleakage protectionis required.
(forfurtherinformation,consulttheprocessordatasheet)
Replenishment:
Eachreplenisherstoragetankhasa30litre capacityandshouldbelocated ongroundlevelwitheasy
access -pleasetakenotice oftherequiredminimumwallclearenceforservicingandcleaning
Automatic Cooling:Theprocessorelectronicswillautomaticallydetectovertemperaturedeveloper
conditionsandthenactivatea coldwatercoolingsystem(Chiller).WhereaChillerisnot used,the
temperatureofthe incoming„mains“coldwatersupplyshouldbe between7 -15 C inorderforthe
coolingsystemtooperate efficiently.
Processorventilation: Theprocessoris suppliedwithan exhaustportlocatedatthefeedendofthe
processor.During installation,thesafetycoverof theportshouldberemovedbyaqualifiedpersonand
theopenportmustthen connectedtothemainexhaustfacilityatthe installationsite(with sufficientpower
toventilatethewarmexhaustairaway.
Where theprocessoris installed ina„through wall“locationwherebyan auto feederorfeedtable is
positioned ina darkroomandthemain bodyofthe processorisindaylight,it isimportantthatthe
darkroomispressurisedtoensureapositiveairflow fromfeedtodryerthusavoidingcondensationrelated
problems.
...........................seemoreaboutthis onpage6
IndustrexM43ic

page3/9
documentno.:X1-25_4.pdf
EnvironmentRequirements
RoomTemperature: 15-30°C(59-86°F)
Relative Humidity: 40-76%RH(noncondensingoveroperatingtemperaturerange)
Altitude: Maximumaltitude2424m(8000ft)abovesealevel.
AmbientLight: Roomlighting shouldnotexceed450lux(150 ft-candles) atthe
PROCESSOR.Theroommustbecapableofgoingcompletelydark
whenloadingfilmintothePROCESSOR.
HeatOutput: 2200Btu/hour
Ventilation:
•Volume-full load,2,100 L/min(75ft3/min),maximum,24hoursperday
•66°C(150°F)maximum
•EXHAUSTDUCTfromthebuildingwith anAdjustableAirGap-0.76
-2.54 mm(0.03-0.10in.)of water
•10.2 cm(4in.)DUCT0.25-1.02mm
Checklocalcodesforventingrequirements.
•Ifventingis notcorrect,fumeswill corrodethe equipment.DonotinstallthePROCESSORor
ACCESSORIESifthe ventingis notcorrect.
•Ifthe PROCESSORisinstalledwithanAUTOFEEDERorFEEDTABLEis located inthedarkroomandthe
PROCESSORis installedinadaylightlocation,thedarkroommusthaveadequatepressuretoensurea
positiveairflowfromtheFEEDtothe DRYER.Thisshouldavoidcondensationproblems.
•Theairflowiscorrectwhenthefumesareflowingoutthe PROCESSORthroughtheEXHAUSTHOSE.
•Iftheventilationistobeconnectedto thePROCESSOR,measurenegativestaticpressureinthe
EXHAUSTDUCT.Seeonthepagex.
PlumbingRequirements
•Allplumbingrequirementsmustcomplywithlocalandnationalcodes.DonotuseIRONPIPES.
•AllDRAINmaterialmustbemadeof chemicallyresistant,non-corrosivematerial.UsePVCorthe
equivalent.
WaterSupply •Temperature
–10°-60°C(64°-140°F)
–Ifthetemperatureofthewatersupplyishigherthan60°C(140°F),installa
WATERCHILLER.
–AtemperedwatersupplyisrecommendedforcleaningthePROCESSORandfor
mixing chemicalsmanually.
• Filtered
–50-micronWALTERFILTEREDisrecommendedinthe inputwaterline
•Flow Volume
– 2.5L/min
• Pressure
–3-10bars
•Location:
–AccessibletoboththePROCESSORandtheREPLENISHMENTTANKS
HOSES 2-waymagneticVALVEwith 3/4”HOSE connectionusing aDVGWsystemdeviceor
PIPEdevice
DRAIN •Size:32mm (5.4in.)HOSEconnection
•MinimumDiameter-7.6cm(3in.)withnoobstructions
•DistancefromPROCESSOR-1.5m(60 in.)
•Heightfromfloor-TopoftheDRAINorDRAINCONTAINERSmustbelowerthan
thebottomof thePROCESSOR.
•Capacity
–1L/min(1/4gal/min)duringnormaloperation
–2.85 L/min3/4gal/min)fordrainingallthreesolutionstogether
–0.95L/min(1/4gal/min)ifeachsolutionisdrainedseparately

page4/9
documentno.:X1-25_4.pdf
DEV
FIX
3/4"Watersupply
Drain
DEV
FIX
2x30LReplenishmentcontainersare
suppliedwiththeprocessor.
WaterSupply,Drainconnection and Replenishment:
Exhaust-port
(see moreon page6)
OPTIONAL

page5/9
documentno.:X1-25_4.pdf
WaterIN
totheProcessor
for cleaning
1
3
34
5
1
2
3
8
9
10
2
5
7
8
2
7
3
6
11
1
6
11
33
3
3
Watersupply-kitassy: OrderNo.:90 60 008
12 12
12
Pos. No.Part No. Beschreibung Description Quantity
190 45 000 Schlauchholländer3/4"Hoseconnector- 3/4in 3
290 45 001 Kugelhahn 3/4" InLineTap 3
3 90 45 002 Doppelnippel3/4" 3/4in straightfitting 8
4 90 45 003 T-Stück3/4" T-Fitting 3/4in 1
590 45 004 Bogen 3/4"-90° 3/4in Elbow-90° 2
6 90 45 005 Reduzierung Male/Femalefitting 2
7 90 45 007 Holländer Filterinlet/outletfitting 2
8 90 45 009 Dichtung Flatwasher 2
9 90 45 027 Filtergehäuse FiterHousing 1
10 90 45 035 Filterpatrone FilterCartridge 1
11 90 70 420 Schlauch1/2" Hose1/2" 4meters
12 90 81 826 Schlauchklemme Hoseclamp 3
1

page6/9
documentno.:X1-25_4.pdf
external exhaustfan
processor
exhaustport
(dis100mm)
flexible hoseorfixedpiping system
(dia100mm)
airflow
positionformeasurement
Asmentionedearlier,toprotecttheprocessoraswellasanyequipment thatmaybedirectlyinterfaced
toorwiththeprocessor,theprocessormustbe connectedtoanexternalexhaustsystem.
(failuretocorrectlyventilatethe processoranddryerexhaustwillresultin corrosion
within the processorandinterfacedequipment-inaddition,theprobabilityofprocessor-related film
artifactsis increased).Theexhaustsystemprovidedattheinstallationsiteshouldcomplyasfollows:-
1) Thedisposaloftheeffluentairmustcomplywithalllocalenvironmentalsafetlycodesandregulations.
2) Thefollowing calculationshouldbe used todeterminethe fficiencyofthe systemprovidedandthatthe
thecorrectamountofend tobeconnectedto theprocessor.Topreventventurieffectattheductopening,
allmeasurementsshouldbemadeatapoint30cmfromthe openendoftheductto beattached tothe
processor.
3) MeasurementcanbemadetypicallyusingaDwyerAirMeter(seetheimage below)Ifsucha device is
notavailable,contactyourlocalrepresentiveforfurtherinformations.
4) If solidmetalorrigidplasticductingis attachedtotheprocessorin a mannerwhich wouldprevent easy
removal,asmallholemaybecreatedatapoint approximately30 cmfromthe processorventilation
port.The„L“shapedmetaltubeprovided withtheDwyerAirMetercan thenbeinserted throughthe
opening. When measuringnegative air,the tubetipopening shouldbe pointedinthedirectionof airflow
awayfromthe processor.Theprocessormustbede-energizedwhenmakingairmeasurements.Theair
metershouldbeheldintheverticalpositiontoassurethe greatestaccuracy.Themetertubing mustnotbe
kinked.
Itis mostimportant that negativeairflow inthe processorexhaustductremains
constantwhentheprocessoris intherun,standby,and shut-downmodes.
Whenprocessorsareinstalledindarkroomwall openings,itis mostimportant
thatdarkroomairpressureexceedstheairpressureofthearea surrounding
thedarkroomThis is intendedtopreventaircascadingthroughtheprocessor
intothe darkroomarea.Properbalancingof dark/lightedroomairinaddition
tocorrectdryerventingwillnotonlymaximizecontainmentof chemicalfumes
andvaporswithintheprocessoranditsdryerexhaustingsystem,butthe
incidenceof filmartifactsoccurringintheout-of-solutiontransport roller
sectionswill begreatlyreduced.Topreventpositiveairflowfromflowing back
intothe processorfromthebuildingexhaustthereshouldbean airgapnot
exceedingmorethan5.08cm(2.0in.)between theprocessorexhausthose
andthebuildingexhaust.thiswillbenefitthesiteintwo ways:
1.The gapcanbeadjustedtoprovidecorrectnegativeflow incaseswhere
buildingexhaustexceedsrequirements.
2.Preventpositiveflow returningtotheprocessor.
NeagtiveStaticPressure-Waterhead
at100mmtubesize: min0,76mm-max.1.02mm
NOTE:Iftheventilation tubing is connectetto house-internal exhaust
system,anair-gabof 5cm(2inch) has to beprovidedaccordinghly.

page7/9
documentno.:X1-25_4.pdf
recommendedInstallation:"Free-standing"
Dark
Stop cock
50cm
PositiveAir
Pressure

page8/9
documentno.:X1-25_4.pdf
recommendedInstallation:"ProcessorDarkroom-Exittolight"
Dark
Daylight
Stop cock
50cm
PositiveAir
Pressure

page9/9
documentno.:X1-25_4.pdf
recommendedInstallation:
"InfeedinDarkroom-processorindaylight"
Dark
Daylight
Stop cock
50cm
PositiveAir
Pressure
Other manuals for M43ic
1
Table of contents
Other Industrex Computer Hardware manuals
Popular Computer Hardware manuals by other brands

ADLINK Technology
ADLINK Technology NuDAQ PCI-9111DG user manual

VIA Technologies
VIA Technologies VAB-3000 quick start guide

NETGEAR
NETGEAR WG511v1 - 54 Mbps Wireless PC Card 32-bit... installation guide

Asus
Asus TXP4 user manual

Omron
Omron CP1L - 12-2007 Operation manual

EK-Quantum
EK-Quantum LGA1700 user guide