Inkel MA-410 User manual

OPERATING
MUTRUCHOIY
me
Y
/
MODEL
MA-44¢
iy
y
MA-610
/
7)
MA-910
t
4f
+
/
PROFESSIONAL
_’
MUSIC
AMPLIFIER

Unpacking
and
Installation
Although
it
is
neither
complicated
to
install
nor
difficult
to
operate
your
stereo
amplifier,
a
few
minutes
of
your
time
is
required
to
read
this
manual
for
a
properly
wired
installation
and
becoming
familiar
with
its
many
features
and
how
to
use
them.
Please
take
a
great
care
in
unpacking
your
amplifier
and
do
not
discard
the
carton
and
other
packing
materials.
They
may
be
needed
when
moving
your
set
and
are
required
if
it
ever
becomes
necessary
to
return
your
set
for
service.
Never
place
the
unit
near
radiators,
in
front
of
heating
vents,
in
excessively
humid
or
dusty
location
to
avoid
early
damage
and
for
your
years
of
quality
use.
Connect
your
com-
plementary
components
as
illustrated
in
the
following
page.
Features
e
HIGH
RELIABILITY
To
assure
absolute
Jong-term
reliability,
the
output
section
of
each
channel
incorporates
Multiple
Emitter
Power
Transistor,
which
provide
safety
margin
4:1.
HIGH
POWER
DRIVE
Triple
diffused
high
power
driver
transistors
are
employed
along
with
high
speed,
high
voltage
devices
for
pre-driver
and
inverter
stages.
ENERGY
LIMITERS
Voltage-current
type
energy
limiters
are
incorporated
for
overload
protection
of
the
amplifier.
Due
to
the
large
safe
operating
area
of
the
output
stage,
the
limiter
does
not
actuate
until
driving
1.4
ohm
load
at
full
power.
¢
THERMAL
OVERLOAD
PROTECTION
In
MA-410
and
MA-610,
to
protect
the
output
stage
from
thermal
overload,
the
output
will
be
automatically
diconnected
from
the
load
(Loud
speaker)
by
use
of
thermal
switch
when
the
heatsink
reaches
to
95°C.
The
load
will
automatically
be
reconnected
when
the
temperature
drops
to
below
95°C.
In
MA-910,
when
the
temperature
of
main
heatsink
reaches
to
70°C,
fan
is
activated.
And
the
fan
is
stopped
when
the
temperature
drops
below
70°C.
AC
POWER
PROTECTION
When
a
harmful
DC
voltage
is
detected
at
the
output
terminals,
the
protection
relay
cuts
off
the
pri-
mary
AC
line.
SURGE
CURRENT
PROTECTION
:
These
amplifiers
are
provided
with
output
fuses
to
protect
the
loudspeakers
from
surge
current.
BRIDGED
MONO
FUNCTION
For
more
powerful
sound,
these
amplifiers
can
be
used
for
monoral
sound
by
selecting
the
mode
selec-
tor
to
bridged
mono
function.
,
,
Please
refer
to
BRIDGED
MONO
operation.

Rear
Panel
Connections
OUTR
AUDIO
MIXER
MULTI
AMP
SYSTEM
ELECTRONIC
CROSSOVER
[°
°
ea
os
Was
wae
Saae
Ea
Q
Le
SPEAKER
L
a
@

Front
Panel
and
Rear
Panel
Controls
jnKes
macro
PROFESSIONAL
MUSIC
AMPUFIER
1.
POWER
SWITCH
To
turn
the
Amplifier
ON
or
OFF,
press
the
upper
or
lower
of
this
switch
button.
2.
POWER
INDICATING
LED
This
LED
indicates
power
is
turned
ON.
3.
HANDLES
You
can
handle
this
amplifier
easily
by
using
these
handles.
4.
VU
meter
The
large
VU
meters
are
provided
to
monitor
the
output
power
of
each
channel.
5.
CLIP
INDICATORS
Two
LED
indicators
illuminate
when
the
input
signal
levels
exceed
3dB
above
clipping.
Then
you
had
better
properly
adjust
the
level
controls.
6.
LEVEL
CONTROLS
Separate
level
controls
are
provided
for
channel
one
and
channel
two
input.
Clockwise
rotation
of
the
controls
increases
level.

10.
11.
Bridged
Mono
Operation
.
Set
Mode
Selector
to
MONO.
.
INPUT
CONNECTORS
These
XLR
jacks
are
for
unbalanced
input
signal.
A
nominal
RMS
voltage
of
1.5
volts
will
drive
the
amplifier
to
rated
output,
and
the
input
impedance
are
nominally
15000
ohms.
.
MODE
SELECTOR
Bridged
mono
operation
is
easily
achieved
by
this
recessed
slide
switch.
The
input
is
applied
to
chan-
nel
one
only,
and
the
corresponding
front
panel
gain
control
is
used
to
set
the
level.
Please
note
Bridged
Mono
Operation.
.
OUTPUT
TERMINALS
Output
terminals
are
dual
five-way
binding
posts,
which
are
identified
as
to
polarity
with
a
red
and
a
black
terminals.
We
suggest
the
use
of
dual
banana
plugs
as
a
convenient
and
reliable
method
of
hook-up.
Do
not
parallel
the
two
outputs
of
each
channel
by
connecting
them
(together,
or
parallel
them)
with
any
other
amplifier
output.
FUSE
HOLDER
This
fuse
holder
contains
AC
primary
fuse.
When
fuse
is
blown
out,
it
should
be
replaced
with
the
same
type
just
like
following
table.
If
it
continues
to
blow,
stop
replacing
fuse
and
refer
servicing
to
qualified
personnel.
AC
100V/120V
AC
220/240V
*
Output
fuses
are
built
in
the
sets.
AC
POWER
CORD
Plug
this
AC
input
cord
into
AC
outlet.
.
Connect
a
mono
input
signal
to
channel
one
input
jack.
.
Connect
the
speaker
load
to
the
two
red
terminals
of
each
channels.
Please
confirm
the
(+)
terminal
of
speaker
to
channel
one
and
the
(—)
terminal
to
channel
two.
.
Do
not
use
the
black
terminals
of
each
channel.
5.
Please
notice
to
connect
the
speaker
impedance
8
ohm
or
above.
.
And
adjust
the
channel
one
volume
not
to
illuminate
the
clip
LEDs
of
front
panel.
si
ase

Specifications
MODEL
MA-410
MA-610
MA-910
Rated
Output
Power
at
8
ohms,
1KHz
(Bridged
Mono)
260W
560W
700W
at
8
ohms,
1KHz
(Stereo
per
CH)
100W
175W
300W
at4
ohms,
1KHz
150W
280W
400W
Total
Harmonic
Distortion
Channel
Separation
at
1
KHz
Dimensions
483(W)x
133(H)x385(D)mm
483(W)x177(H)
x385(D)mm
Weight
(Net)
18
Kg
19
Kg
27
Kg
Power
Requirement
AC100V/120V/220V/240V
,
50Hz/60Hz

MODEL
MA-910
VOLUME
BD.(4005117500)
°
;
CHANNEL
ONE
'
LEVEL
METER
d
!
THERMAL
SWITCH
‘
=
q
NN
Z
O
O
CHANNEL
ONE
OUTPUT
FUSE
Or.O
;
CHANNEL
ONE
x
|
Aearssow
|
‘1
OUTPUT
CHANNEL
ONE
(HPUT
LBV
(Optien
:
0.
778¥)
|
(
ar
(6)
O
6
§
=
;
owe!
alk
O
TO
AR
UI
SUB
BD.(40051
16600)
R6C2
OUTPUT
BRIDGED
MONO
ane
CHANNEL
TWO
OUTPUT
FUSE
ONO
O
JN
Z|
OUTPUT
CHANNEL
TWO
O
Se
es
al
me
FAN
MOTOR
141LS-2282
CHANNEL,
Two
INPUT
1,
8V@ptten
|
0.
778V)
CLIP
FROM
CH2
CHANNEL
TWO
(SAME
AS
CHANNEL
ONE
)
INPUT
TO
CH2
PROTECTION
RELAY
BRIDSED
MOHD
BRIDGED
BD.
eT.
(40051!
7600)
(2828098810)
POWER
BD.
(40051
17400)
t20v,
50
/60r2
22V/50Hz
FOR
UL,CSA
VERSION
PGR.
GENERAL
——
SERVICE
INFORMATION——
EUROPE
VERSION
1,
RESISTANCE
VALUES
ARE
INDICATED
IN
OHMS
UNLESS
OTHERWISE
SPECIFIED.
(K
=1000,
M=100,000)
2.
CAPACITANCE
VALUES
ARE
SHOWN
IN
MICROFARADS
UNLESS
OTHERWISE
NOTED
.
(A
MICRO-
MICROFARADS
)
3.
ALL
VOLTAGES
ARE
REFERED
TO
GROUND
UNDER
THE
FOLLOWING
CONDITIONS.
@505
:
TRIAC
TC25C
60
'
ac:
RMS
Q10!
-
9103,
0401
,
0402
,
0591-0504,
O60!
*
KTC
2240BL
4
——
PRECAUTION
——
2104,
Q110
:
KTCIOISY
(A)
ALL
COMPONENTS:
manxen
A\
must
BE
REPLACED
ONLY
WITH
ORIGINAL
TYPE
SPECIMED
BY
Q105,
Q112:
2NS41B.
‘THE
MANUFACTURER
,
DONG
WON
PA
SOUND
AND
INSTALLED
AS
THE
ORIGINAL
wiTH
Q107,
0108:
2N3440
@)
SPACERS
AND
POSITIONED
AWAY
PROM
ADJACET
COMPONENTS
WHERE
APPLICABLE
.
Q109
:
KTCISISY
1B)
ALL
SOLDERING
MUST
BE
DONE
IN
A
PROFESSIONAL
MANNER
USING
SOLDER
WITH
Qitl,
Qr13-—O123
:
280424
RESIN
CORE
ONLY.
125,26
:
KTASTOBL
"a
C)
ALL
COVES,
SHIELD
ANO
INSULATING
SPACERS
MUST
BE
REPLACED
BEFORE
RETURNING
Q106
|
28C
3423
APPLIANCE
TO
CUSTOMER
|
DIOi
-
DIOB,
Dit,
DiI4
>
COGae
1D)
A
DAMAGED
POWER
SUPPLY
CORD
MUST
BE
REPLACED
BEFORE
RETURNING
APPLIANCE
D109,
DIO,
DIIS
:
1IN4004
To
CUSTONER
EDI,
DOO!
:
PB2sz
EBC
Pg
£)
A
DIELECTRIC
TEST
CONBISTING
OF
ISOOVAC
GOHZ
18
TO
BE
APPLIED
BETWEEN
BOTH
ec.
BLADES
OF
THE
POWER
SUPPLY
CORD
ATTACHMENT
PLUG
AND
THE
EXPOSE
CONDUCTIVE
Bec
Baes
2usais,
KTc
1815¥
SURMACE
OF
THE
APPLIANCE
FOR
A
PERIOD
OF
NOT
LESS
THAN
ONE
SECOND
BEFORE
20040
wawiey
RETURNING
TO
APPLIANCE
TO
CUSTOMER.
PY
THE
—BAW-E-
MARKED
RESISTORS
ARE
MOUNTING
ABOVE
THE
P.C.B
ON
SLEEVES.
eto.
9007009420

MODEL
MA-410
MA-610
a
TOSARIUL
=
(MA-
410)
VOLUME
BO
4005117500
“o
|
an
q.
7
oe.
ens
oan
om
INPUT
1.5V
(Option
:
0.775)
cao
—
|
©
CHANNEL
ONE
OUTPUT
FUSE
a
cab
O
RI39
47KB
p12
|]
over
cram,
one
cue
ouTPuT
BRIDGED
MONO
]
OUTPUT
CHANNEL
TWO
PT
CHANNEL
Two
(2828096000
MA-410)
LEVEL
METER
(2828098800
MA-G10
(SAME
AS
CHANNEL
ONE
)
PT
(2828096010
MA-410)
(2828096010
MA-
610)
(2828098900
MA-610)
Owe
A
&
Subs
=
ols
POWER
BD
4005117400
——
SERVICE
WIPORMATION—
1,
REMSTANCE
VALUES
ARE
INDICATED
IN
OHMS
UMLESS
OTHERWISE.
(K=1,000,
M=1,000,000)
:
:
2.
CAPACITANCE
VALUES
ARE
SHOWN
I
MICROFADADS
UNLESS
OTHERWISE
NOTED.
(M=
MICRO—MICROPARADS)
we
Pombo
3.
ALL
VOLTAGE
ARE
REFERED
TO
GROUND
UNDER
THE
FOLLOWING
CONDITIONS.
=
——
NOTES
ac
cams
3
one
3
[=
[=
[=
[el
2)
ALL
COMPONENTS
manKED
/|\MUST
BE
REPLACED
ONLY
WITH
ORIGINAL
TYPE
SPECIFIED
@Y
THE
=
C908;
Foe:
-f
MANUFACTURER
,
DONG
WON
PASOUND
AND
INSTALLED
AS
THE
ORIGINAL
WITH
SPAGERS
AND
POSITIONED
ANAY
FROM
ADJACENT
COMPONENTS
WHERE
APPLICABLE.
8)
ALL
SOLDERING
MUST
BE
DONE
IN
A
PROFESSIONAL
MANNER
USING
SOLDER
WITH
RESIN
CORE
ONLY.
C)
ALL
COVERS,
SHIELD
AND
INSULATING
SPACERS
MUST
BE
REPLACED
BEFORE
RETURNING
APPLIANCE
TO
CUSTOMER
0)
A
DAMAGED
POWER
SUPPLY
CORD MUST
BE
REPLACED
APPLIANCE
TO
CUSTOMER.
€)A
DIELECTRIC
TEST
COSISTING
OF
ISOOV
AC
GOHE
[S
TO BE
APPLIED
BETWEEN
BOTH
BLADES
OF
THE
POWER
SUPPLY
CORD
ATTACHMENT
PLUG
AND
THE
EXPOSE
CONDUCTIVE
SURFACE
OF
THE
APPLIANCE
FOR
A
PERIOD
OF
NOT
LESS
THAN
ONE
SECOND
BEFORE
RETURNING
TOAPPLIANCE
TO
CUSTOMER.
F)
THE
PW
MARKED
RESISTORS
ARE
MOUNTING
ABOVE
THE
P.C.B
ON
SLEEVES.
—noTe—
e101
-
at08
OPTION.
401
—
oe
|
KTC
220080,
@501—
500
120,
121,
RIBZ,
RIZE
>
MA-
GIO
ONLY
0104,
G108
:
KTA
970M
gi08
1
2903423
i
0106,
02
:KTIOISY
one-o1@
;
280424
:
<
-s
£
KTC
188
¥
aw
iwTeIMBY
ow
p09)
pon
RTA
1OSY
Q107,
@11K
|
2NB
4S
ou
KTA
970
SL
@108,0116
:2N3440
DNO,DIT
=
1N4004
kre
22408L
ON3,
One
=
KTCZZ8Y
oot
1
PB2sz
This manual suits for next models
2
Table of contents
Other Inkel Amplifier manuals