Innotech SPAR-11 Series User manual

© INNOTECH Arbeitsschutz GmbH. Errors, misprints, technical changes reserved!
© INNOTECH Arbeitsschutz GmbH. Errors and misprints excepted. We reserve the right to make technical changes.
SPAR-11
Instruction manual
DE – ACHTUNG: Die Verwendung des INNOTECH-Produkts ist erst zulässig, nachdem die
Gebrauchsanleitung in der jeweiligen Landessprache vollständig gelesen und verstanden wurde.
DE
EN – ATTENTION: Use of the INNOTECH product is permitted only after the instruction
manual has been read and fully understood in the respective language.
EN
IT – ATTENZIONE: L'utilizzo del prodotto INNOTECH è permesso solo previa lettura e
comprensione dell'intero manuale di istruzioni nella lingua del relativo paese di utilizzo.
IT
FR – ATTENTION : L'utilisation du produit INNOTECH n'est autorisée qu'après avoir
entièrement lu et compris la notice d'utilisation dans la langue du pays concerné.
FR
NL – ATTENTIE: Dit INNOTECH-product mag pas gebruikt worden nadat u de gebrui-
kershandleiding in de taal van het betreffende land gelezen en begrepen hebt.
NL
SV – O B S : Denna INNOTECH-produkt får inte användas förrän bruksanvisningen på
respektive lands språk har lästs igenom och förståtts.
SV
DK – GIV AGT: Du må først bruge et produkt fra Innotech, efter du har læst og forstået
brugsvejledningen i fuldt omfang i dit lands sprog.
DK
ES – ATENCIÓN: Se autorizará el uso de los productos INNOTECH una vez que se hayan
leído y entendido las instrucciones de uso en el idioma del país.
ES
PT – ATENÇÃO: O uso do produto INNOTECH apenas é permitido depois de ter lido e
compreendido na totalidade as instruções de uso na respetiva língua nacional.
PT
PL – UWAGA: Produkty firmy INNOTECH mogą być używane dopiero po dokładnym
zapoznaniu się z całą instrukcją obsługi w ojczystym języku.
PL
TR – DİKKAT: INNOTECH ürününün kullanımına ancak ilgili ülkenin dilinde sunulmuş
olan kullanım kılavuzunun tamamen okunmasından ve anlaşılmasından sonra izin verilir.
TR
SL – POZOR: Uporaba izdelka INNOTECH je dovoljena šele po tem, ko ste navodila preb-
rali v celoti v ustreznem jeziku svoje dežele in jih tudi razumeli.
SL
CZ – POZOR: Práce s výrobkem INNOTECH je povolena teprve po kompletním přečtení a
porozumění návodu k použití v jazyku daného státu.
CZ
SK – POZOR: Produkt INNOTECH môžete používať až po prečítaní a porozumení celého
návodu na použitie pre príslušnú krajinu.
SK
HU – FIGYELEM: Az INNOTECH termékek használata csak azt követően engedélyezett,
hogy saját nyelvén elolvasta és megértette a teljes használati utasítást.
HU
ZH – 注意:只有在仔细阅读并完全理解了当地语言的使用说明后,才能使用 INNOTECH 公司的产品。
ZH

2SPAR-11/180226/www.innotech.at
EN
1TABLE OF CONTENTS
[2] DESCRIPTION OF SYMBOLS 3
[3] SAFETY INSTRUCTIONS 4
[4] COMPONENTS/MATERIAL 6
[5] USE 7
[6] INSPECTION 8
[7] WARRANTY 9
[8] APPROVAL 9
[9] SIGNS & MARKINGS 10
[10] DIMENSIONS 11
[11] INSTALLATION TOOLS 12
[12] INSTALLATION SUBSTRATE 12
[13] INSTALLATION 14
[14] LOAD DIRECTIONS 18
[15] DISPOSAL 18
[16] ACCEPTANCE LOG 19
[17] RESTRAINT SYSTEM INSTRUCTIONS 21
[18] TEST LOG 22
[19] DEVELOPMENT & SALES 24

3
EN
SPAR-11/180226/www.innotech.at
2DESCRIPTION OF SYMBOLS
Supplementary information/Instruction
Warning/danger information
For an IMMEDIATE threat of danger that can cause serious physical
injuries or death.
ücorrect incorrect
For a POTENTIALLY dangerous situation that causes serious physical
injuries or death.
For a POTENTIALLY dangerous situation that could lead to minor physical
injuries and damage to property.
!
DANGER
!
WARNING
CAUTION
!
Wear protective gloves!
Wear safety spectacles!
Comply with manufacturer's instructions/applicable instruction manuals.

4SPAR-11/180226/www.innotech.at
EN
3SAFETY INSTRUCTIONS
- The safety system may be installed or used only by persons who are:
• trained in "personal protective equipment" (PPE).
• in good physical and mental health Medical conditions such as
Cardiovascular problems, intake of medicines, consumption of
alcohol,... negatively affect the safety of the user.
• familiar with the locally applicable safety regulations.
- The restraint system may be installed only by experts familiar with the roof safety
system and in compliance with the current state of the art.
- When installing/using the INNOTECH "SPAR-11" anchorage device, the respective
accident prevention regulations (e.g.: working on roofs) must be complied with.
-A plan must be available that species the rescue procedures for all possible
emergencies. Attention! After a fall, an extended period of suspension in the
personal protective equipment can cause severe injuries or even death (suspension
trauma).
- Before starting work, ensure that no objects from the work site can fall to the
ground. The area below the work site (pavement, etc.) must be kept clear.
- Plan, install, and use the anchor point in such a manner that no fall over the edge
is possible if the personal protective equipment (PPE) is used properly. See planning
documents at www.innotech.at.
- At the access to the roof safety system you must document the positions of the
anchorage devices by means of diagrams (e.g. sketch of the roof top view).
- Do not make any changes to the safety system.
- If used on inclined roof surfaces, roof avalanches (ice, snow) must be avoided by
means of suitable snow interception devices.
- After a fall and the resulting strain, you must stop using the safety system, and have
it checked by an expert (component parts, fastening to the substructure, etc.).
-If you supply the safety system to external contractors, these latter must conrm in
writing that they have understood this instruction manual.
- If the equipment is sold to another country, the instructions of use must be provided
in the respective national language.
- Comply with the local lightning protection regulations.
The following safety instructions and the latest state of the art must be complied
with.
3.1 GENERAL

5
EN
SPAR-11/180226/www.innotech.at
3SAFETY INSTRUCTIONS
If uncertainties arise during the installation, it is imperative that you contact
the manufacturer.
3.2 FOR SAFE INSTALLATION
3.3 FOR SAFE USE
- All stainless steel bolts must be greased with a suitable lubricant before installation
(provided: Weicon AntiSeize ASW 10000 or equivalent quality).
- Ensure that stainless steel does not come into contact with swarf or steel tools, as
this can lead to corrosion.
-Use dowel logs and photos of each installation situation to document the professional
attachment of the safety system to the building structure.
- The roof covering must be correctly sealed as per applicable guidelines.
- The minimum free space necessary under the edge is calculated as follows:
Deformation of the anchorage device under load + manufacturer's specication for
the personal protective equipment used + body height + 1 m safety distance.
- Correct use of the individual elements including “personal protective equipment”
must be ensured, because otherwise the safe functioning of the safety system is
NOT guaranteed.
- Attachment to the INNOTECH "SPAR-11" is always made with one carabiner
through the rotating anchorage eye, and this must be used with personal protective
equipment in accordance with EN 361 (safety harness) and EN 363 (fall arrest
system).
-ATTENTION! For horizontal use, lanyards may be used only if they are suited
for this purpose and have been tested for the respective edges (sharp edges,
trapezoidal sheeting, steel girders, concrete, etc.).
- Do NOT use restraint systems if wind speeds are higher than normal.
-Children and pregnant women must NOT use the safety system.

6SPAR-11/180226/www.innotech.at
EN
4COMPONENTS/MATERIAL
A) Instruction manual
B) Lubricant: Weicon AntiSeize ASW 10000
C) Anchorage eye: Stainless steel AISI 304
D) M16 Lock nut: Stainless steel AISI 304
E) Hex nut M16: Stainless steel AISI 304
F) 2x Washer M16: Stainless steel AISI 304
G) Hex bolt M16x70 mm: Stainless steel AISI 304
ABC
DEGF
4.1 INNOTECH "SPAR-11-50"
4.2 INNOTECH "SPAR-11-125"
A) Instruction manual
B) Lubricant: Weicon AntiSeize ASW 10000
C) Anchorage eye: Stainless steel AISI 304
D) M16 Lock nut: Stainless steel AISI 304
E) Hex nut M16: Stainless steel AISI 304
F) Washer M16 3D: Stainless steel AISI 304
G) Threaded rod M16x170 mm: Stainless steel AISI 304
ABC
DEGF

7
EN
SPAR-11/180226/www.innotech.at
4COMPONENTS/MATERIAL
INNOTECH "SPAR-11" was developed as an anchor point for personal safety
for 3 people (including 1 person for rst aid use) and is suitable for the following fall
protection systems in accordance with EN 363:2008:
- Restraint systems
- Fall arrest systems
- Rescue systems
Comply with the manufacturer's instructions for the personal
protective equipment being used.
5INTENDED
USE
DANGER TO LIFE through incorrect use.
- INNOTECH "SPAR-11" must be used ONLY for personal safety.
-NEVER suspend loads from the INNOTECH "SPAR-11".
!
DANGER
4.3 INNOTECH "SPAR-11-200-500"
A) Instruction manual
B) Lubricant: Weicon AntiSeize ASW 10000
C) Anchorage eye: Stainless steel AISI 304
D) M16 Lock nut: Stainless steel AISI 304
E) 6x Hex nut M16: Stainless steel AISI 304
F) 2x Washer M16 3D: Stainless steel AISI 304
G) Threaded rod M16x250-550 mm: Stainless steel AISI 304
ABC
DEGF

8SPAR-11/180226/www.innotech.at
EN
6.1 INSPECT BEFORE EVERY USE
6INSPECTION
If there are any doubts concerning the reliable operation of the fall
protection system, it must NO LONGER be used and must be checked
by an expert (written documentation).
If necessary, the product must be replaced.
DANGER TO LIFE from damage to the INNOTECH "SPAR-11".
- INNOTECH "SPAR-11" must be in perfect working condition.
- Do NOT use INNOTECH "SPAR-11" any longer if:
• Damage or wear to its components are obvious.
• Other defects were observed (loose threaded joints, deformation,
corrosion, wear, etc.),
• Strain has occurred due to a fall (exception: provision of rst aid).
• It is not possible to read the product labelling.
!
DANGER
Prior to each use, INNOTECH "SPAR-11" must be checked visually for any obvious
defects.
Refer to the test log for inspection intervals.
6.2 INSPECT ANNUALLY
Have INNOTECH "SPAR-11" checked at least once per year by an expert who is familiar
with the safety system. The user's safety depends on the eectiveness and durability of
the equipment.
Shorter inspection intervals may be required, depending on the intensity of use and the
environment (e.g. in corrosive atmospheres, etc.).
Document the inspection by the expert in the test log of the instruction manual, and
keep this with the instruction manual.
Check the entire safety system's suitability for use, on the basis of the acceptance log
and test log.

9
EN
SPAR-11/180226/www.innotech.at
7WARRANTY
For normal conditions of use, the guarantee period for manufacturing defects on all
parts is 2 years from the date of purchase. The time limit is shortened for use in
corrosive atmospheres.
If there is strain (a fall, weight of snow, etc.), the warranty claim is void for those
components that are designed to absorb energy or to deform.
For system installation, and for components planned and installed
by expert installation companies under their own responsibility,
INNOTECH assumes neither responsibility nor warranty in the case
of improper use.
8APPROVAL
INNOTECH "SPAR-11" was tested and certied as an anchorage device as per
EN 795:2012 TYPE A and CEN/TS16415.
The notified authority participating in the type test is:
DEKRA EXAM GmbH, Dinnendahlstr. 9, 44809 Bochum, Germany C0158
The type test was performed in accordance with EN 795:2012
Authority that participated in the national technical approval, as per federal state
building code:
Deutsches Institut für Bautechnik (DIBt), Kolonnenstrasse 30 B, D-10829 Berlin,
Germany Z-14.9-732

10 SPAR-11/180226/www.innotech.at
EN
9SIGNS & MARKINGS
A) Name or logo of the manufacturer/retailer: INNOTECH
B) Type designation: EAP-SPAR-11
C) Signs stating that the instruction manual
must be followed:
D) Maximum number of persons that can be secured: 3 (including 1 person for
provision of rst aid)
E) Year of manufacture and manufacturer's JJJJ-..-...
serial number:
F) Number of the applicable standard: EN 795:2012 TYPE A
G) DIBt approval number: Z-14.9-732
for SPAR-11-50 only
S
P
A
R
-
1
1
-
X
X
X
9
5
7
:
2
N
0
E
1
.
2
.
.
-
T
.
.
Y
-
P
J
J
A
J
J
max.
AB
C
D
EF
S
P
A
R
-
1
1
-
5
0
9
5
7
:
N
2
E
0
1
.
2
.
.
-
T
.
.
Y
-
P
J
J
A
J
J
max.
Z-14.9-732
AB
C
D
EF
G

11
EN
SPAR-11/180226/www.innotech.at
10 DIMENSIONS
50
M16
28
[mm]
130
M16
L
M16
Standard length (L): 200/300/400/500 mm
(Special lengths upon request)
SPAR-11-50
SPAR-11-125
SPAR-11-200-500
Clamping area = usable
thread length less 110 mm

12 SPAR-11/180226/www.innotech.at
EN
11 INSTALLATION TOOLS
12 INSTALLATION SUBSTRUCTURE:
12.1 CONCRETE
The basic requirement for professional/correct installation is statically load-bearing
construction concrete (solid concrete) with a concrete quality of a minimum of
C20/25, and the use of the original fasteners listed in this instruction manual.
DANGER TO LIFE as a result of installation on unsuitable installation substrate.
- Install INNOTECH "SPAR-11" on statically load-bearing construction concrete (solid
concrete) having a concrete quality of at least C20/25.
-DO NOT install on screed, levelling concrete, blinding concrete etc. ...
-In case of doubt, have the installation substructure checked by a structural
engineer or by the manufacturer.
APPROVED ADHESIVE:
COMPOUND MORTAR
FISCHER (compound mortar) FIS SB 390 S (INNOTECH "MONT-FIS-SB-390-S")
HILTI HY 200
Not included in the delivery!
[mm]
Ø = 18
AF = 24
2x

13
EN
SPAR-11/180226/www.innotech.at
100
≥
140
≥
24
≥
≥
47
12 INSTALLATION SUBSTRUCTURE:
Wooden formwork
140
≥
100
≥
==
140≥
140≥
≥ 47
= =
12.2 WOOD
≥
20
≥
20
47
≥
≥
4
12.3 STEEL CONSTRUCTION

14 SPAR-11/180226/www.innotech.at
EN
13 INSTALLATION
13.1 CONCRETE
1.
2.
≥ 300
18
O
130
160
≥
4x
ALTERNATING

15
EN
SPAR-11/180226/www.innotech.at
13 INSTALLATION
3. FISCHER compound mortar FIS SB 390 S
(INNOTECH "MONT-FIS-SB-390-S") or HILTI HY 200
DANGER TO LIFE if UNAPPROVED adhesives are used.
- Use only approved adhesives
(see section on installation substructure).
!
DANGER
3
2
1
Adhere to the setting time!

16 SPAR-11/180226/www.innotech.at
EN
13 INSTALLATION
5.
125
≥
100 EN 795
≥
300 DIBt
18O
125
≥
100 EN 795
≥
300 DIBt
18
O
4.
2x

17
SPAR-11/180226/www.innotech.at
EN
100
≥
140
≥
24
≥
≥
47
13 INSTALLATION
13.3 STEEL CONSTRUCTION
2x
≥
20
≥
20
47
≥
≥
4
13.2 WOOD
2x
Wooden formwork
140
≥
100
≥
==
140≥
140≥
≥ 47
= =

18 SPAR-11/180226/www.innotech.at
EN
14 LOAD DIRECTIONS
DANGER TO LIFE when used in UNAPPROVED load directions.
- Use INNOTECH "SPAR-11" only in the approved load directions.
!
DANGER
Concrete EN 795
Wood
Steel construction
Concrete DIBt

19
EN
SPAR-11/180226/www.innotech.at
15 DISPOSAL
ORDER NUMBER:
PROJECT:
CLIENT: Specialist:
Company address:
CONTRACTOR: Specialist:
Company address:
INSTALLATION: (ýmark with a cross where applicable)
PRODUCT: Item SPAR-11 Year of manufacture/Serial number: ___________
Single anchor point (EAP)
Specialist:
Company address:
ACCEPTANCE LOG NO. ____ (PART 1/2)
SPAR-11
Do NOT dispose of the safety system in household waste.
As per national requirements, collect the used parts together, and dispose of
them in an environmentally correct manner.
16 COPY TEMPLATE
ACCEPTANCE LOG

20 SPAR-11/180226/www.innotech.at
EN
16 COPY TEMPLATE
ACCEPTANCE LOG
FASTENER/PHOTO DOCUMENTATION
PRODUCT: Item Year of construction/Serial number:
Identication marking of anchorage point (e.g.: INNOTECH "STABIL-STA-10-300",
INNOTECH "FALZ-15-45", ...)
Installation substrate:
(e.g.: solid concrete, quality: C20/25, wood rafter dimension, for sheet metal roofs: roof manufacturer, profile, material, sheet metal
thickness, etc.)
Date: Location:
Dowel type:
BEF/Sticker?/
Designation
Setting
depth:
[mm]
Drill bit Ø:
[mm] Torque:
Photos:
(storage
location)
mm mm Nm
mm mm Nm
The installation company who signs warrants correct workmanship (edge spacing, inspection of the substructure, proper cleaning of
bores, compliance with curing times and processing temperature, compliance with the dowel manufacturer's guidelines, etc.)
The client accepts the work performed by the contractor. The instruction manual, documentation of the fastenings, and photo
documentation and test logs have been transferred to the client (building owner) and are to be made available to the user. When
accessing the safety system, the building owner must document the positions of the attachment devices by means of diagrams (e.g.
sketch of the roof top view).
The expert tter familiar with the safety system conrms that the installation work has been executed correctly, as per
the state of the art, and as per the manufacturer's instructions of use. The technical safety reliability is conrmed by
the installation company.
Handover of: (e.g: personal protective equipment PPE, fall arrest devices HSG, storage cabinet, etc.)
Item Item Item Item
Included in lightning protection system? YES NO
Comments:
Name:
ACCEPTANCE LOG NO. ____ (PART 2/2)
SPAR-11
Client
Date, company stamp, signatureDate, company stamp, signature
Inspection: contractor (expert who is familiar
with the safety system)
This manual suits for next models
3
Table of contents
Other Innotech Rack & Stand manuals

Innotech
Innotech LOCK-11 User manual

Innotech
Innotech SAND-01 User manual

Innotech
Innotech SYST-20-475-695 Series User manual

Innotech
Innotech SYST-01-410-610 User manual

Innotech
Innotech SOPV-NOVO-AIO User manual

Innotech
Innotech STA-16 User manual

Innotech
Innotech BARRIER-VARIO User manual

Innotech
Innotech QUAD-13 User manual

Innotech
Innotech SAND-01 Instruction manual

Innotech
Innotech BEF-210-A2 User manual