3
EN
> 1.50 m
SYST-20-475-695 / Version 170512 / www.innotech.at
-If structural alteration work is performed close to the fall protection system following the
nalinspectionofthesafetysystem,youneedtoensurethattheworkwillnotaect
the safety of the installed fall protection system! If in doubt, consult a structural
engineer or contact the manufacturer.
-For horizontal use, only those lanyards may be used that are suited for this purpose
and have been tested for the respective edges (sharp edges, corrugated sheeting,
steel girders, concrete, etc.).
-Thereisahazardwhencombiningindividualelementsofthespeciedunits,sincethe
safe function of one of the elements can be impaired through the combination.
(Followthespecicinstructionsprovidedwitheachelement!)
-Before use, you must visually check the entire safety system (fall protection system and
anchor points (=guide bushes)) for obvious defects (e.g. loose screws, deformations,
abrasion, corrosion, defective roof sealing, etc.). If there are any doubts concerning the safe
function of the safety system, it must be inspected by an expert (written documentation).
-At least once a year, an expert must check the complete fall protection system
including the personal protective equipment used. The inspection by an expert
must be documented in the provided test log.
-After a fall and the resulting strain, you must stop using the fall protection system and
have it checked by an expert (component parts, fastening to the substrate, etc.).
-“SYST” was developed for personal safety and may not be used for other purposes.
Neverattachundenedloadstothesafetysystem.
-Do not use fall protection systems if wind speeds exceed normal parameters.
-Following strong storms, inspect the tin roof (substrate) before continuing to use
the safety system.
-Do not make any changes to the approved anchorage device.
-If used on sloping roofs, roof avalanches (ice, snow) must be avoided by means of
suitable devices to intercept snow.
-If you provide the fall protection system to external contractors, the familiarity with
theinstructionsforinstallationandusemustbeconrmedinwriting.
-If the equipment is sold in other countries, the instructions for installation and use
must be provided in the respective national language!
-For reasons of statics, you must maintain a margin of at least 1.50 m to the end of
the roof deck.
A product that no longer appears to be safe must not be used further,
and must be replaced immediately!
> 1.50 m
1SAFETY INSTRUCTIONS