ATTENTION INSTALLERS:
These instrucons must be
le with the customer
30 Day Technical Support: 01908 226545
This service is only available to customers from
the day of delivery Mon-Fri 10:30-15:30, please
have your supplier’s details and your postcode to
hand before calling.
Replacements Parts: Inside of your warranty
period contact: www.insigniarange.co.uk/support
Spares/Replacements Parts: Outside of your
warranty period visit www.insigniaoutlet.co.uk
WARRANTY REG NO: _______________________
To claim your full 2 year warranty, register your shower within 90 days at: www.insigniarange.co.uk/warranty
CHECK ALL CONTENTS BEFORE BUILD COMMENCES. NO RETURNS CAN BE MADE
ONCE THE BUILD HAS STARTED AS IT IS DEEMED ACCEPTANCE OF PRODUCT!

www.insigniarange.com Last Modied: 20/08/2020
02
Contents
Thank you for your purchase 3
Tips for assembly 4
Electrical/Pressure/Tool requirements 5
Box contents 6
Screw Pack contents 7
Levelling the Tray/Installing the Waste 8
Applying RubberGum 9
Installing the Right Side Panel and Right Column 10
Installing the Back Panel 11
Accessories Installaon 12
Installing the Le Column 13
Installing the Right Corner Upright 14
Connecng the Framework 16
Installing the Framework 17
Installing the Le Corner Upright 19
Installing the Le Side Panel 21
Installing the Roof 23
Installing the Right Front Fixed Glass 24
Installing the Right Front Fixed Glass Seals 25
Installing the Le Front Fixed Glass 26
Installing the Le Front Fixed Glass Seals 27
Installing the Door Handles, Seals and Magnets 28
Installing the Door Wheels and Doors 29
Valve/Water Connecons 30
Control Panel Connecons 31
Steam Generator Connecons 32
Connecng the Water Supply 34
Signing o your Shower 35
Control Panel Instrucons (Steam Version) 36
Control Panel Instrucons (Shower Cabin Version) 37
Bluetooth and Radio Tuning Instrucons 38
Parts list 39
Steam Room & Shower Safety Guide 40
Steam Room Usage Guide 41
Bathroom Electrical Zones 42
WEEE Compliance Statement 44

www.insigniarange.com Last Modied: 20/08/2020
03
Thank you for your recent purchase of an Insignia shower. Please read this booklet
with great care to ensure you get the best out of your build and have a shower that
will last for many years to come! Like everything, in order to obtain a rst class
product that will serve you well for many years, the eort and correctness put into the
assembly will reect in the quality of your nish.

www.insigniarange.com Last Modied: 20/08/2020
04
Before we start, here’s our 4 top ps which may assist you...
TIP 1—Building Your Shower
This product is suitable for a DIY build, providing you are condent in your DIY abilies. Please look through this build guide and decide
on whether you feel condent in undertaking this task. If you are not, seek the services of a professional and show them these
instrucons before hiring.
TIP 2—Hard Water
Due to the nature of this product we highly advise the purchase and ng of a water soener.
(Please note: limescale build up may cause damage to your shower and will not be covered under warranty)
TIP 3—Installaon
These showers are designed to be free standing and movable from their locaon should you have the need to replace anything.
ALWAYS USE Flexible braided water inlet pipes (not supplied) at least a metre long (not central heang plasc type!)
NEVER FIX with rigid pipes, NEVER FIX the unit to the wall or oor.
TIP 4—Sealing
When using Insignia’s RubberGum, please ensure the product does not come in contact with your silicone as this will cause the
RubberGum to fail and will not adhere as intended. Rubbergum is immediately waterproof and will gain addional strength over me.

www.insigniarange.com Last Modied: 20/08/2020
05
We recommend a BAR pressure between 2.5 and 3.4 BAR. If
you have a combi boiler system no problem should be
experienced. If you have a gravity feed older type installaon
(hot water tank type usually less than 1 BAR) you will almost
certainly need a pump. We cannot advise on which type of
pump is used, locaon or design because all house plumbing
layouts vary. This is a job for your installer/plumber. The end
delivery however must fall within the scope above.
Important Note Do not exceed 3.4 BAR pressure under any
circumstances. Warranty is void if so as damage will occur. If
you have a combi supply, please use a pressure reducing valve
if required to lower the BAR pressure to the shower.
Please Remember that this product is free standing and is
designed to be pulled away from the wall.
The waste hose must be of a exible type (1m exible waste
supplied).
The water supply pipes need to be at least 1 metre in length
and must be that of a exible braided type (not supplied).
DO NOT OVERTIGHTEN THE BRAIDED HOSES AS IT CAN CAUSE
THE CONNECTION TO POP AFTER A FEW WEEKS OF USE.
Always t easy to get to isolaon taps on both hot and cold
water supply (not supplied). Just like a dishwasher or washing
machine, this product MUST be isolated when not in use.
You will require:
• Scissors
• Knife
• Spirit Level
• Lond Nosed Pliers
• Tape Measure
• Philips Screwdriver
• Electric Drill
• Safety Gloves
• Safety Glasses
Pressure/Water Requirements Tools Required
• RubberGum (supplied)
• Plumbers Mait (not supplied)
• Hot and cold isolaon valves (not supplied)
• 6 x Braided hoses (not supplied) Steam version
requires 7.
• 2 x 15mm equal T-Valves (supplied)
Parts Required
STEAM VERSION
Voltage Rang 220-240AC
Frequency Rang 50Hz
Power Rang 3KW
NON-STEAM VERSION
Voltage Rang 100-240AC
Frequency Rang 50/60Hz
Power Rang 12v DC/1500 mA
Your electrical contractor should understand ALL legal
requirements of connecon before undertaking any work
or installaon.
UNDER NO CIRCUMSTANCES UNDERTAKE THIS
YOURSELF!!!
Note for electrician: This product comes with 13 amp plug
(s) ed with an RCD unit (steam version only). We leave it
this way for you to connect it your own way due to
connued addions to current regulaons.
1) Connect within current laws and IP direcves.
2) (Preferred) Wire into isolated fused feed connecng
directly to the house consumer/service box.
Always use protecon against electrical surge. Your shower
should be treated the same as a home computer. A surge
protector should eradicate the possibility of either the
transformer or control panel being burnt out.
Electrical work needs to be signed o by a fully qualied
operave by law. Failure to adhere to this will not only void
your electrical warranty for your shower, but could void
your house insurance too.
Electrical Requirements
Other manuals for Premium Series
3
This manual suits for next models
1
Table of contents
Other Insignia Hot Tub manuals
Popular Hot Tub manuals by other brands

CalderaSpas
CalderaSpas CalderaSpas Utopia Series owner's manual

anko
anko SS-601A user manual

CalderaSpas
CalderaSpas CANTABRIA owner's manual

Dimension One Spas
Dimension One Spas HYDRO SPORT Installation and owner's guide

Bestway
Bestway Lay-Z-Spa Maldives HydroJet Pro manual

Dimension One Spas
Dimension One Spas Nautilus Specifications