manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Integra
  6. •
  7. Switch
  8. •
  9. Integra Xmart STA-16A User manual

Integra Xmart STA-16A User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

USER MANUAL - STA 16A
___________________________________________________________________________________________________________________________________
www.xmart-ups.com VER.2010.21 (ENG) 1701-STA-16 220V- EN - 1
ENGLISH
VER. 2010.21
USER MANUAL: STA-16A
AUTOMATIC TRANSFER SWITCH
1. PRODUCT DESCRIPTION
This is an automatic selector or switch with 2 AC inputs and 1 AC output.
AC output is always connected to the pre-selected AC input (For example Input A). In case input A has a power failure, STA-16A
automatically switches to connect Input B to the output. When STA-16A detects power in input A is reconnected, it switches back to input A.
This device is usually used for 2 main applications:
1.- To offer redundant input for one UPS, connecting 2 different AC lines to STA-16A inputs (A & B) and connecting UPS to the STA-16A
output or
2.- To offer UPS redundant system by connecting 2 different UPS at STA-16A inputs and output powering to the protected system.
FRONT PANEL:
1. SWITCH ON/OFF input A (main input line) 5. USB Port
2. SWITCH ON/OFF input B (secondary input line) 6. RS232 Port
3. Output Breaker for 16A outlet (12) 7. Intelligent port for LAN card
4. Output Breaker for 10A outlets (10) & (11) 8. Operation panel
REAR PANEL:
9. Dry contact output (Relays) 12. AC outlet (capacity 16A)
10. AC outlets (capacity 10A) 13. Input socket for Input Line "A"
11. AC outlets (capacity 10A) 14. Input socket for Input Line "B"
USER MANUAL - STA 16A
___________________________________________________________________________________________________________________________________
www.xmart-ups.com VER.2010.21 (ENG) 1701-STA-16 220V- EN - 2
2. INSTALATION
This product can be installed either in a 19" rack cabinet or over a flat surface as well. For 19” Rack installation, we strongly recommend using
the installation accessories included with the unit.
In case of installing in a rack cabinet, please follow the instructions below.
1. Install according to figure above.
2. Connect input "A" in input socket "A" in rear panel.
2. Connect input "B" in input socket "B" in rear panel.
4. Connect protected products to STA-16A outlets. Note there are multiple outlets with 10A capacity and 1 outlet with 16A capacity.
3. OPERATION
OPERATION PANEL:
1. Selector for main input: Selects the preferred input.
2. Preferred Input LED: Indicates what is the preferred or pre-selected input (A or B). Preferred input is selected pushing button “1”.
3. Status Input LED: Indicates status for each input
 LED A: ON: Input "A" OK
 LED A: OFF: Input "A" OFF (no voltage)
 LED A: Blinking (Flashing): Input "A" voltage is out of range (low or high input)
 LED B: ON: Input "B" OK
 LED B: OFF: Input "B" OFF (no voltage)
 LED B Blinking (Flashing): Input "B" voltage is out of range (low or high input)
4. Output LED: Indicates what input is connected to the output
 LED A: ON: Output connected to input "A"
 LED B: ON: Output connected to input "B"
5. Alarm LED: Alarm indicator
6. Alarm Mute
OPERATION:
TURN-ON:
After connecting all input and output cables, just activate input switches A and B to ON position.
SELECTING PREFERRED INPUT:
Select preferred input by button "1" in front panel. Default preferred input is "A".
USER MANUAL - STA 16A
___________________________________________________________________________________________________________________________________
www.xmart-ups.com VER.2010.21 (ENG) 1701-STA-16 220V- EN - 3
4. COMMUNICATION PORTS
 USB*: USB communication using dedicated software. Pin 1: VBUS / Pin 2: D- / Pin 3: D+ / Pin 4: GND
 RS-232*: Serial communication using dedicated software. Pin 2: TX / Pin 3: RX / Pin 5: GND / Pin 6: +12Vdc
 Dry Contacts Outputs Port (Relays)
 Intelligent Port for SNMP Card (Optional)
* check software manual for additional information.
DRY CONTACTS OUTPUTS PORT
It is formed by 6 pins (1 to 6, from left to right) and provides information about status of AC inputs (A & B) and STA-16A situation according
to following figure.
 Pin 1: Common point.
 Pin 2: Closed = Output connected to input "B"
 Pin 3: Closed = Output connected to input "A"
 Pin 4: Closed = Input "A" OK
 Pin 5: Closed = Input "B" OK
 Pin 6: Closed = STA OK
NETWORK COMUNICATION (SNMP)
An optional SNMP XMART card can be installed in the Intelligent Port located in front panel of STA-16A, to monitor the unit operation. To
install SNMP card, remove the cover of Intelligent Port (retained by 2 screws), in order to insert the card as shown in the next figure:
Then tight both screws to fix SNMP card to STA front panel.
Having this modern and efficient mean of communication and control allows you to:
• To know real time parameters of inputs “A” & “B”, such as: Voltage, Frequency and Status
• Having STA-16A output information: Voltage, Frequency. Current, Load Percentage and Watts/Hour.
• Receiving Alarm messages from STA-16A, as well as internal temperature.
• Connecting our Sensor-TH to SNMP Card, to know temperature and humidity in the working area and setting alarms.
• Emailing all STA alarms to previously programmed addresses.
• Configuring STA-16A operational parameters, like valid voltage and frequency ranges for both inputs, as well as overload alarm level
and maximum overload permitted.
Al relevant information about STA-16A operation is available thanks to this option, moreover remote configuration is possible for an efficient
operation in your installation.
More information about configuration, operation, and monitoring of STA-16A thru SNMP card in SNMP LAN CARD manual.
5. SAFETY & QUALITY STANDARDS
Standards and Certifications: CE
IP PROTECTION IP20 (static)
QUALITY MANAGEMENT: Manufactured under: ISO 9001 : 2000
ENVIRONMENTAL MANAGEMENT: Manufactured under: ISO 14001 : 2004
Any modification made by user or operator may affect compliance of the safety and performance certifications listed above. Therefore, manufacturer is not
responsible of any modification made on the product or its accessories after it is manufactured. This product is designed to operate in domestic and
commercial environment.
USER MANUAL - STA 16A
___________________________________________________________________________________________________________________________________
www.xmart-ups.com VER.2010.21 (ENG) 1701-STA-16 220V- EN - 4
6. TECHNICAL SPECIFICATIONS
7. SAFETY
Read carefully this manual and comply with all safety instructions. This product must be installed by qualified technician only. Keep this
manual on hand for any future revisions.
SAFETY & USE:
ADVERTENCIA: This unit operates with potentially dangerous voltages. Therefore, it must be installed, maintained, and repaired for qualified
personnel only.
WARNING: This device must be installed following instruction from this manual. The manufacturer is not liable for any damage that might
rise from misusing this unit or defective installation.
WARNING: This product has been designed to operate safely and reliably for years. Nevertheless, as it is an electrical device, it is required to
read and understand this manual. Keep manuals as references for future consults.
WARNING: This product has been designed to be used indoors, protected of water, direct sun light and extreme temperatures. This device
must not be used outdoors, close to moisture or heat sources. Avoid direct sun light.
WARNING: Do not set objects on this equipment. Handle with care. Do not block UPS ventilation.
WARNING: Make sure to connect this unit to proper power line according to selected model. The Technical Specs sticker shows power
rating information. DO NOT connect this device to any of its own power outlets.
WARNING: DO NOT connect life support medical equipment, microwave ovens, vacuum cleaners, refrigerators, or any other appliance to this
device.
WARNING: In case of emergency turn off the unit pressing Power Button, unplug it and call technical support.
DISPOSAL
We strongly recommend disposing this product according to regulations in your country to prevent possible
environmental damages; besides some parts might be recycled.
 Technical information on this manual is property of XMART . This manual Information cannot be copied or distributed totally or
partially without written approval of XMART.
 XMART can introduce modifications in their products or manuals without further notice.
 XMART is not responsible of mistakes or missing information in this manual.
 XMART is not responsible for wrong use a third part can do of this information.
 Trademarks and logos in this manual are property of their owners.
ATS 16A - 220V 16
A
Capacity / Capacidad (VA): 16A @ 220V (3.500VA)
Input / Entrada
Voltage / Voltaje (VAC) 220/230/240Vac
Range / Rango (VAC) 180 - 258 Vac
Frequency / Frecuencia (Hz) 50 / 60Hz
Max Input Current / Corriente Max: 16 Amps
Inlets / Tomacorrientes de Entrada 2 x IEC C20
Output / Salida
Voltage / Voltaje (VAC) 220/230/240Vac
Power Outlets / Tomacorrientes de Salida 8 x IEC-C13 (10 Amps) + 1 x IEC-C19 (16 Amps)
Protections / Protecciones
Overload & Shortcircuit / Sobrecarga &
Cortocircuito AC Breaker for each input / Disyuntor AC para cada entrada
Transfer Time / Tiempo de Transferencia
Transfer Time / Tiempo de Transferencia 4 - 8 ms
Size & Weight / Características Físicas
Size / Dimensiones (cm) 330x483x44 mm
Net Weight / Peso Neto (Kg.) 5,0
Gross Weight / Peso Bruto (Kg.) 6,0
Operating Conditions / Ambientales
Temperature / Temperatura 0-40°C
Humidity / Humedad < 90% (no condensing)
Noise / Ruido < 40dB