Inter-m 600 series User manual


3
When you need to change paging system..

P.09P.09P.10P.10----P.23P.23P.18P.18P.07P.07P.29P.29P.11P.11P.28P.28
Inter-M system..

5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CONTENTS

07
DigitalAnalog
6000 system introduction
6000 SYSTEM

08
6000 system introduction- Easy control by PC operation program(GUI)- Zone feedback to PC system operator- Keeping a LOG file and audio recording on PC- Evacuation according to scenarios - PC interface support a variety of function - Real-time self-diagnostics and remote control by data transfer- Dual-Bus composition of PC & equipment (Broadcasting available without PC)
- Can accommodate variety of multi-purpose facilities built on traditional PA systems, such as 9000/600- PC control functions to maximize user convenience- Multi Broadcasting: Up to 8 different broadcastings on 8 different areas(with Matrix PX-6216 added)- Can be applied to various places, such as, schools, government offices, department stores, large supermarkets, hospitals, galleries, museums, factories, and etc
6000
REMOTE
4원화5원화7원화8원화6원화1원화2원화3원화
x16
REMOTE
Macro
Time

09
ES-9116
PX-9116
RG-9116
PS-9116I
TB-9116
ECS-616
(ECS-9216)
9000/600 SYSTEM
R
RM-916
9000/600 system digital convergence

PC control
RME-6108
ER-6116
PC control
ECS-6216P/S
RM-6024/6012KP
DIB-6000 PC remote control + Macro functionExtension of remote microphone (16units)Emergency scenario broadcasting (PC failure)
10
9000/600 system digital convergence

11
8Bus matrix extension
1BUS2BUS3BUS4BUS5BUS6BUS7BUS8BUS
1CH BGM2CH CDP3CH CD-Rom4CH Deck5CH EM6CH Etc16CHMATRIX
16 x 8
PX-6216
6000 SYSTEM

12
PC based system control
Speaker line check andstatus displayAmp fault detect andstatus displayAC/DC power & controlBattery voltage/currentdisplayTP controlEM scenario broadcasting
RS-485
6000 SYSTEM SC-6224AFD-6214PD-6359APB-6207TP-6231PV-6232EMPC(GUI S/W)
Total Management
MS-6100/6800

6000 system major product
13 •Priority based broadcasting connection betweenEP-6216 + RM6024 •16CH auto fire sensor input•EM and BGM based 16CH operation•Zone macro key setup function•Key extension(RM-6012KP x 2set)•Interface unit of ECS-6216P and PC•Connect Mic input and PC by USB port•Remote Mic extension function(RM-6024 support 16 Mic)•Broadcasting priority setup ( RM1>RM2>…RM8)•PC scenario saving unit for PC failure •Available to extend max 10set

6000 system major product
14
•16 x 8 audio matrix function•16CH VR and 7band EQ control function•6 preset and control•8Bus system configuration•Priority based broadcasting connection betweenEP-6216 + RM6024•16CH auto fire sensor input

6000 system major product
15 •
EM scenario sound source saving unit connectionwith ER-6116
•Added RS-485 communication to SC-634 todisplay information to GUI software•Added RS-485 communication to AFD-614 tocheck the status of Amp to GUI software•Added RS-485 communication to PD-9359A todisplay the status of AC/DC power supply.•Added RS-485 communication to PB-9207 todisplay recharge status of Battery charger toGUI•Added RS-485 communication to TP-9231 fortelephone paging

6000 system major product
16
•2CH audio Tcp/IP transmission unit•Data, sensor, serial communication Tx/Rx•8CH audio fiber transmission•Sensor(8CH) and serial communication•Single mode, Max 15Km•8CH audio fiber receiver unit•Sensor(8CH) and serial communication
•1CH 300W/2CH 600W Power amplifier•DC 24V for EM Power supply AC power•Slim and compact 1U rack size•4CH 300W Power amplifier•IndependentSMPSpowersupplyforeachchannel•Slim and compact 1U rack size

RM-01 or
Dynamic Mic
Fire receiver
PD-6359A
PB-6207
ECS-6216PDIB-6000
EP-6216
ECS-6216S
SERVER PC CLIENT PC
ER-6116
PV-6232
PRE AMP
DISTRIBUTOR
CD/TUNER
MS-6100
17
1Bus diagram

PC MIC
Sensor
Audio
RS-232
RS-485
RS-485 & Audio
USB TO UART
SPK OUT
POWER AMP
AFD-6214
SC-6224
RME-6108
TP-6231
RM-6024/
6012KP x2
RM-6024 x8
RM-6024 x8
POWER AMP
18
1Bus diagram

Line Level Signal
100V Signal
Line + Control Signal
Control Signal
MS-6800
Server PC
USB 2.0
RS-485
8x8 Matrix
E
Matrix (16 x 8)
16 Channel Mixer
(In/Out VR, EQ)
PC Control
16 CH Input
8
PX-6216
RME-6108
DIB-6000
RM-6024/
RM-6012KP
8Bus matrix diagram
19

RS-485
RS-232
Emergency
Reception &
Sectional
Expansion Unit
Relay Group
Speaker Selector
EM Selector
Terminal Board
8x8 Output
VOICE FILE
ECS-6216MS
EMERGENCY PANEL
ER-6116
POWER AMPLIFIER
PC MIC
Client PC
RM 1 + CD
TUNER
MIC + CD
RM 2
RM 3
CD
RM 4
PC TIMER
Fire receiver
8Bus matrix diagram
20

6000 system + S.R convergence
6000 SYSTEM
PC(GUI S/W)
PX-6216
POWER AMPLIFIER E
AOE-212
AMP x8
ITN(48kHz)
Paging system
Long distance
transmission
High quality
S.R convergence
FTA-108S (Fiber Optic)
ITX-102(ITN)
IRX-102 CSP-4.8
KEN-824
2CH
(Stereo)
2CH
(Stereo)
4CH ITN(48kHz)ITX-102(ITN)
21
Table of contents
Other Inter-m Network Hardware manuals