Interface Devices AA-54 Instruction manual

AA-54 Air Amplifier
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
INTERFACE DEVICES, INC. 230 Depot Road, Milford, CT 06460
Ph: (203) 878-4648, Fx: (203) 882-0885, E-mail: [email protected]
www.interfacedevices.com
IMPORTANT! FILE THIS MANUAL IN A SAFE PLACE FOR FUTURE SERVICE & PARTS NEEDS
ALWAYS REFERENCE THE SERIAL NUMBER FOR SERVICE & PARTS REQUESTS
Pump Serial Number:
Pump Model Code:
Sold to:
Purchase Order:
Contact:
End User:
Order Date
STATEMENT OF WARRANTY
INTERFACE DEVICES, INC. (hereafter, the factory) warrants it’s products to be free from defects in material
and workmanship under normal use and service for a period of one (1) year from date of shipment from the
factory. Any defect discovered after the warranty period has expired will be deemed to be outside the above
coverage. No goods claimed to be under warranty shall be accepted for return unless authorized by the
factory beforehand.
Upon discovery of a defect (other than freight damage) or a shortage of an item received in the original factory container,
the purchaser shall, within (10) calendar days, deliver notice of the defect or shortage. Damaged freight claims must be
placed with the freight carrier and will not be honored by the factory. If after due investigation of a claim of defect or
shortage is found valid, the factory, at it’s sole discretion, may discharge it’s entire obligations to the purchaser by either
repair or replacement of the defective product or component and for shortages by furnishing a replacement of the missing
quantity (FOB, factory).
This express warrantee supersedes and is in lieu of all other remedies and warranties,
including the implied warranties of merchantability and fitness for a particular purpose, and
liability for negligence. IN NO EVENT SHALL THE FACTORY BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL LOSSES, EXPENSES OR DAMAGES INCLUDING
DAMAGES FOR PERSONAL INJURY OR COMMERCIAL LOSS.
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 2 of 9
AA-54 2:1 AIR AMPLIFIER
TABLE OF CONTENTS
1.0 INSTALLATION & OPERATION PAGE
1.1 Mounting...........................................................................3
1.2 Connections......................................................................3
1.3 Start-up.............................................................................3
2.0 MAINTAINENCE
2.1 Routine Maintenance........................................................3
2.2 Troubleshooting................................................................4
3.0 DRAWINGS ENCLOSED
3.1 General Arrangement Drawing……………........................5
3.2 Exploded View & Bill of Materials ………...........................6
3.4 Pneumatic Schematic........................................................8
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 3 of 9
1.0 INSTALLATION
1.1 MOUNTING:
The amplifier comes standard with a foot mounting bracket (four 1/4 inch fasteners required).
The unit may be mounted vertically (wall mount) or horizontally (floor mount).
1.2 CONNECTIONS:
Connect a dry and filtered air supply to the 3/8 NPT "AIR IN" port on the pump. NO Lubricator Is
required).
Connect your high pressure circuit to the 3/8 NPT "AIR OUT" port on the pump.
1.3 STARTUP:
Starting with the pump mounted air regulator backed-out all the way, slowly increase the pressure by
turning the regulator knob clockwise. The pump will start to cycle while regulated pressure flows
directly through the pump to the circuit.
The pump will stall when circuit pressure reaches 2 times the regulated pressure. The pump will
maintain this pressure even if there is some circuit leakage. At this time check for and fix any
circuit leaks since this only causes unnecessary air consumption and wear and tear on the pump.
2.0 MAINTAINENCE:
2.1 ROUTINE MAINTAINENCE:
The only routine maintenance required is to re-grease the main air spool (item 6), the pilot piston
O-ring (item 7) and the T-seals (item 5) every 6 months. Refer to the enclosed 4-way cycling valve
assembly drawing.
2.2 TROUBLESHOOTING GUIDE: See following table on page 2.
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 4 of 9
2:1 AIR AMPLIFIER TROUBLESHOOTING GUIDE
(Refer to enclosed Exploded View Drawings)
SYMPTOM PROBABLE CAUSE(S) REMEDY
Pump will not cycle.
No pressure at output.
No air supply to pump.
Pump air regulator supply set
too low.
Look for and fix.
Increase setting.
Pump will not cycle with
regulated pressure at
output.
Four-way Air reciprocating
valve spool stuck at mid-
position.
After trying remedy above,
spool still sticks:
Disconnect/Reconnect air
supply
(Re-sets air spool to end
position.)
Disassemble air valve
assembly
Inspect for contamination
or mechanical bind. Repair
or replace, lubricate seals
with water-proof grease.
Pump makes one cycle,
then stops.
Faulty item 24 "2-way air
valve"
(Broken, leaks or
contaminated).
Repair or replace.
Pump cycles constantly
when "dead-headed".
External leak at pump or
downstream
high pressure circuit.
Stuck open or contaminated
item 6
"Check Valve" cartridge (4
places).
Internal leak in pump.
Look for and correct.
Clean or replace. Note
valve orientation at
assembly.
Check all dynamic and
static seals
and gaskets. Replace if
necessary.
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 5 of 9
For further assistance call INTERFACE DEVICES, INC. at 203/878-4648.
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 6 of 9
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 7 of 9
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 8 of 9
AA-54 Operation and Maintenance Manual
Serial Number «Serial_Number»
Page 9 of 9

Other Interface Devices Amplifier manuals

Interface Devices GA-160 Instruction manual

Interface Devices

Interface Devices GA-160 Instruction manual

Interface Devices GA-54 Instruction manual

Interface Devices

Interface Devices GA-54 Instruction manual

Interface Devices AA-160 Instruction manual

Interface Devices

Interface Devices AA-160 Instruction manual

Popular Amplifier manuals by other brands

Rotel RB-1090-1 Technical manual

Rotel

Rotel RB-1090-1 Technical manual

TE 1410 Operating and service manual

TE

TE 1410 Operating and service manual

Reloop AMPIRE D1700 Operation manual

Reloop

Reloop AMPIRE D1700 Operation manual

Mark Levinson 27.5 operating manual

Mark Levinson

Mark Levinson 27.5 operating manual

Duncan Solstice user guide

Duncan

Duncan Solstice user guide

Crestron X Series quick start

Crestron

Crestron X Series quick start

Perreaux Prisma 750 owner's manual

Perreaux

Perreaux Prisma 750 owner's manual

Mitsubishi Electric MELSERVO-JE MR-JE-C instruction manual

Mitsubishi Electric

Mitsubishi Electric MELSERVO-JE MR-JE-C instruction manual

NAD T955 owner's manual

NAD

NAD T955 owner's manual

Peachtree Audio musicBox owner's manual

Peachtree Audio

Peachtree Audio musicBox owner's manual

Raymer Amplifier 800-40 operating instructions

Raymer

Raymer Amplifier 800-40 operating instructions

Kramer VP-200N-5 user manual

Kramer

Kramer VP-200N-5 user manual

Symetrix SX202 owner's manual

Symetrix

Symetrix SX202 owner's manual

Morel Signature AMP 250 user guide

Morel

Morel Signature AMP 250 user guide

Ashly NE 4200.25 operating manual

Ashly

Ashly NE 4200.25 operating manual

BC Acoustique EX222.3 owner's manual

BC Acoustique

BC Acoustique EX222.3 owner's manual

Nagra PL-L Owner's instruction manual

Nagra

Nagra PL-L Owner's instruction manual

Jadis Orchestra owner's manual

Jadis

Jadis Orchestra owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.