Inventum Technologies BV –VMC-47VJ54-EN-V1
5. Installation
5.1 Preparation
Disconnect power at supply line, circuit breaker or
fuse before installing the device.
Do not place the device in a metal casing.
1. Press the clip and pull the top section
from the bottom section.
2. Open the safety cover. Use a small
flat-tip screwdriver to loosen the clip.
3. When using screws: Use the mounting
plate as a marking template.
4. When using tape:
a. Make sure the surface is
smooth, clean, and degreased.
b. Remove the foil from the
double-sided tape.
5. Remove the breakout plastic from
the cable input of the housing.
5.2 Installation procedure
Make sure that the power supply is disconnected.
1. Lead the power and IO cables
through the back hole (A) or cable
entrances (B).
2. Place the bottom section of the
device.
3. Fasten the bottom section using
the screws or tape.
4. Connect the power cable in the
screw terminals.
5. Connect the 0-10Vdc output cable
in the screw terminals (OUT &
GND).
6. Place the upper section of the
receiver on the lower bottom
section. Push until you hear a click.
5.3 Commissioning
1. Enable the 230V power supply. The led is orange for 3
seconds. After 3 seconds the led shows the binding
mode. The ventilation starts at 100%. After a short time,
the ventilation goes to the active ventilation mode. The
mode of ventilation depends on the last used mode
before switching off. Default is 50%.
2. Within 5 minutes, bind all wireless controls to the device.
See the manual of the used device for specific
instructions. After 5 minutes, the led shows the device
status.
You can bind up to 20 devices.
6. Fault finding