PLDC02160 2
DAILY MAINTENANCE
When you have nished cleaning, pro-
ceed as follows:
• Turn the machine off.
• Activate the parking brake.
• Raise the centre brush and the side
brushes, to prevent damage.
• Recharge the batteries if necessary,
using the connector provided.
When having nished working, activate
the lter shaker for 10 seconds.
Empty the debris bin.
Check and remove any debris wrapped
around the side brushes and on the
centre brush.
WEEKLY MAINTENANCE
Check the level of electrolyte in the bat-
teries, if using acid batteries.
Check that the suction lter is tight and
clean.
REPLACING THE CENTRE BRUSH
• Unscrew the knob and open the door on the left of the machine.
• Unscrew the three knobs securing the brush compartment cover.
• Pull out the brush cover compartment.
• Remove the brush, holding it on the plastic core.
• Remove the adapter from the core of the old brush and t it to the
new brush, taking care to keep the bristles aligned in the same direc-
tion.
• Fit the new brush and make sure that the adapter is inserted on the
drive hub.
• Replace the brush compartment cover using the knobs, following the
dismantling operations in reverse order.
ADJUSTING CENTRE BRUSH PRESSURE
• Unscrew the knob indi-
cated.
• Turn the lever anticlock-
wise to increase pres-
sure, making sure to
align the knob fastening
hole.
• Screw the knob back on.
ADJUSTING SIDE BRUSH HEIGHT
• Move the side brushes to the working
position.
• Loosen the two adjustment screws
underneath the brush lifting knob.
• Manually move the brush to the re-
quired position.
• Tighten the adjustment screws.
0
1
START
00:00
100%
+
+
+
+
+
-
-
-
-
-
Battery
FLOW