IPS IPS121 Manual

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
1
IPS SIGNAL
IMITATOR
TECHNICAL DESCRIPTION AND OPERATING
MANUAL

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
2
Introduction
1. GENERAL DESCRIPTION 4
1.1. Purpose of the device and main capabilities 4
1.2. Contents 4
1.3. Main module 4
1.4. Power supply 5
1.5. Operation modes 6
2. RESTRICTIONS AND RECOMMENDATIONS 9
3. TECHNICAL SPECIFICATIONS 9
4. LIFE TIME AND MANUFACTURER’S WARRANTY 12
5. CERTIFICATE OF ACCEPTANCE 12

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
3
Introduction
Before starting your work with IPS121 carefully read this instruction and save it for further
use as a handbook.
Any information in this manual can be changed fully or partially without further notice.

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
4
1 GENERAL DESCRIPTION
1.1 Purpose of the device and main capabilities
Imitator of signals “IPS121” is designed for generation of signals imitating data
transmission channels of special technical means for data gathering.
“IPS121” allows generation of:
Radio signals with user set frequency value in 100 –6000MHz range, and variable output power
of AM and FM, signals with FHSS, DSSS and PULSE.
Signals imitating data transmission standards (GSM, DECT, BLUETOOTH и WLAN).
HF and LF signals in the 220v power lines and low current lines.
IR signal with LF signal modulation and selection of subcarrier frequency.
Sound and ultrasound signals with user defined frequency or with frequency values
corresponding to octave and third-octave filters and direct connection of speakers to the
IPS121 output socket.
Low frequency magnetic field.
Imitation of nonlinear transition in wire lines.
1.2 IPS121 Contents
1. Main module
2. HF antenna
3. "RJ-45" cable
4. "220V" cable
5. "3/RJ-45" cable
6. Power supply/charger 5V/1A
7. Technical description and operating manual
1.3 Main module description
Main block is an independent device which allows signal generation and emission as well as
nonlinear transition for nonlinear transition detector testing.
Work results will be shown on a graphical colored LCD display with 160X128 resolution.
Device is controlled with rotary knob.
Turning off/on is done by the power switch.
Power is provided by internal Li-Polymer battery or power supply.

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
5
1. Charging indicator
2. "5V" power socket
3. Power switch
4. LF socket - output of low frequency signal amplifier in 0.01-120kHz
range. Speakers should be plugged here
5. RF/UHF socket - output for radio signals in 100-6000MHz range
6. Rotary knob
7. IR emitter
8. Location of magnetic field emitter
9. "RJ-45" socket –output for signal in 0.01-20000kHz range
10. "220V" socket –output for signal in 30-20000kHz range
________________________________________________________________________
1.4 IPS121 Power supply
Battery status icon is located in upper-right corner of main menu screen. Fully colored icon
corresponds to fully charged battery, uncolored crossed with line - discharged.
1.4.1 Battery charging
To charge internal battery, connect power supply. State of power switch has no effect on
charging.
Charging is indicated by constant glow of indicator «CHRG»(Pic. 1 Pos. 1) and animated battery
status icon . Full charge time is approximately 6 hours. When charging is finished indicator will stop
glowing and device will continue to maintain its charge level.

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
6
1.5 Operation modes
After turning the device on you will see the main menu (Pic. 2).
Selection in MENU is done by the ROTARY KNOB rotation, confirmation -
press ROTARY KNOB.
Exiting in previous submenu - press ROTARY KNOB and hold for no less
than 3 seconds.
If "SETTINGS" submenu is selected, you will see general device
settings.
Setting
Description
Value
Default value
Set freq step
Selection of frequency-tuning step
10, 100, 1000, 10000,
100000Hz
100000Hz
Indicate
Sets the brightness for display
from 10 to 100% with step 10
50
Language
Language selection
English (Английский)/Russian
(Русский)
Russian
Fact. defaults
Returns all the settings to the default value
Selection of the "Memorize data" in MENU allows saving current settings (shown on screen)
before turning device off –signal source, frequency, modulation, output power. If this option is selected
on the next startup, device will load in saved mode, bypassing the main MENU.
If submenu «HF/SHF 0.1-6 GHz» is selected in main MENU, you will
see the submenu (Pic. 3) which allows you to work with signals in 0.1-6 GHz
range outputted through "HF-SHF" socket intended for RF antenna.
Setting altering can be achieved using ROTARY KNOB with step selected
in "SETTING." submenu. Default value is 10 MHz.
If "Modulation OFF" is selected it will change carrier signal modulation
type: AM or FM as well as FHSS (Frequency Hopping Spread Spectrum), DSSS
(Direct-Sequence Spread Spectrum) and PULSE.
If AM or FM is selected, "Frequency"option will appear allowing selection of modulation signal
frequency (for AM and FM modulation). "Deviation" option will appear for FM allowing selection of
highest deviation for modulated signal frequency from value of its carrier frequency.
If FHSS is selected there will be 3 options available: "Frequency" –frequency of hopping,
"Band" - bandwidth of hopping, "Channel" - number of hopping channels.
If DSSS is selected, 1 option will be available: "Band" - allowing selection of signal's bandwidth.
If PULSE is selected, 2 options will be available: ''ON xx.xx s”- allowing selection of signal length
and "OFF xx.xx s" - interval between signals.
Output power can be selected in the last item. Power value is given in dBm and mW. Minimum
and maximum values are different for different frequencies.
If this item is highlighted, you can press and hold ROTARY KNOB for 2 second to toggle signal
generation ON or OFF.
Picture 1
Picture 2

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
7
If "GSM 3G DECT WF BT" submenu is selected in main MENU you will
see the submenu which allows work with signals imitating data transmission
standards: "GSM" - GSM900, "3G" - Third generation of mobile
telecommunications, "DECT" - Digital Enhanced Cordless Telecommunications as
well as data transmission standards in 2.4GHz frequency range: "WF" - Wireless
local area network (Wi-Fi) and "BT" - Bluetooth. (Pic. 4)
It is possible to select a standard required to be imitated as well as
output power.
Carrier frequency, band of signal and time parameters of radio impulse
are imitated.
If "LF/MF.01-120kHz" submenu is selected in main MENU, you will see
the submenu which allows work with acoustic and ultrasound signals in 0.01-
120kHz frequency range outputted through "LF" socket. It also turns magnetic
field emitter on. Position of this emitter is marked on the front panel as: "MF". In
this case stray emission of radio-electronic devices is imitated (cell phones,
recorders etc.). (Pic. 5)
"LF" (TRS 3.5”) socket is an output for low frequency amplifier and
intended for speakers (Pic. 6) There are three options for carrier
frequency selection:
Random selection of frequency
Frequencies corresponding to the octave filter.
Frequencies corresponding to third octave filter.
With selection of item "Modulation OFF" it is possible to select
modulation of carrier signal: FM, AM or PWM.
If AM or FM is selected, "Frequency" option will appear allowing selection of modulation signal
frequency (for AM and FM modulation). "Deviation" option will appear for FM allowing selection of
highest deviation for modulated signal frequency from value of its carrier frequency
If PWM is selected two options will appear: "Frequency" allowing selection of frequency of
impulse and "Ratio" allowing selection of interval between impulses.
Power is changed in % of maximum power.
If "RJ-45 .01-20000kHz" submenu is selected in main MENU, you will
see the submenu which allows work with signals in 0.01-20000kHz range
outputted through "RJ-45" socket to "4-5" pair (Pic. 7). Pair "3-6" used as
device's “ground”which allows for asymmetrical connection to the line. Cable
"3/RJ-45" is used for such connection. Black wires are connected to the
“ground”and red to the "4-5" pair.
With selection of line "Modulation OFF" it is possible to select
modulation of carrier signal: FM, AM or PWM.
If AM or FM is selected "Frequency" option will appear allowing
selection of modulation signal frequency (for AM and FM modulation). "Deviation" option will appear for
FM allowing selection of highest deviation for modulated signal frequency from
value of its carrier frequency
If PWM is selected two options will appear: "Frequency" allowing selection of frequency of
impulse and "Ratio" allowing selection of interval between impulses.
Picture 3
Picture 4
Picture 5
Picture 6

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
8
Power is changed in % of maximum power.
If "220V 30-20000kHz" submenu is selected in main MENU, you will see the submenu which
allows work with signals in 30-20000kHz range outputted through "220V" socket to the power lines. This
allows to fully imitate data transmission channel in 220V lines.
With selection of line "Modulation OFF" it is possible to select modulation of carrier signal: FM,
AM or PWM.
If FM is selected "Frequency" option will appear allowing selection of modulation signal
frequency. "Deviation" option will appear for FM allowing selection of highest deviation for modulated
signal frequency from value of its carrier frequency
If PWM is selected two options will appear: "Frequency" allowing selection of frequency of
impulse and "Ratio" allowing selection of interval between impulses.
Power is changed in % of maximum power.
If "IR 940nm" submenu is selected in main MENU, you will see the submenu which allows work
with IR emitter located on the front panel (Pic. 1 Pos. 7).
With selection of line "Modulation OFF" it is possible to select modulation of carrier signal: FM,
AM or PWM.
If AM or FM is selected "Frequency" option will appear allowing selection of modulation signal
frequency (for AM and FM modulation). "Deviation" option will appear for FM allowing selection of
highest deviation for modulated signal frequency from value of its carrier frequency
If PWM is selected two options will appear: "Frequency" allowing selection of frequency of
impulse and "Ratio" allowing selection of interval between impulses.
Power is changed in % of maximum power.
Nonlinear element
There are nonlinear elements connected to the contact pairs "1-2" and "7-8" of "RJ-45" socket in
order to imitate nonlinearity in the wireline (Pic. 7).

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
9
2 RESTRICTIONS AND RECOMMENDATIONS
2.1 Transport and store IPS121 in standard package.
For prolonged storing you should use closed, warm compartment with temperature 10-35C and
humidity no more than 80%.
Transport with caution and try to avoid physical interference with standard package.
2.2 After prolonged (more than 4 hours) stay of the device in cold (less than -5C) it only should be
turned on if there is no evidence of condensate on the device.
2.3 Do not expose LCD display to the direct sunlight.
3 TECHNICAL SPECIFICATIONS
"HF-SHF" socket
Frequency range, MHz 100-6000
Frequency-tuning step, kHz 10, 100, 1000, 10000, 100000
Signal level, dBm -42 –+14*
Stray harmonics, dBm
100-200MHz -15
200-700, 1100-1500MHz -45
800-1000, 1600-6000MHz -30
Signal Sinusoidal, DSSS ,FHSS, PULSE
Modulation AM, FM
Data transmission standards imitation GSM, 3G, DECT, WLAN, BLUETOOTH
Modulation frequency, kHz 0.5, 1, 1, 5, 15
АМ depth, % 70
FM Deviation, kHz 30, 100, 300, 600
Nonlinear distortion of modulating signal, no more than, % 15
FHSS Bandwidth of Hopping, MHz 1, 6, 10, 20, 50, 100
FHSS Number of Hopping Channels 25, 50, 125, 250
FHSS Frequency of hopping, Hz 1, 2, 4, 8
DSSS Bandwidth, MHz 0.3, 0.5, 1, 2, 4
PULSE Signal transmission time, sec 0.0001- 99
PULSE Signal accumulation time, sec 0.01-5999
*Variation range depends on signal frequency and selected standard

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
10
"RJ-45" socket
Frequency range, kHz 0.01-20000
Maximum signal amplitude, V 3.5
Modulation AM, FM, PWM
Modulation frequency, kHz 0.5, 1, 1, 5, 15
АМ depth, % 15
FM Deviation, kHz 5, 20, 100, 300
Frequency of PWM signal, Hz 1, 10, 40 и 100
PWM Duty cycle 1, 5, 10
"220V" socket
Frequency range, kHz 30-20000
Maximum signal amplitude, V 3.5
Maximum input voltage, V 380
Modulation FM, DSSS
Modulation frequency, kHz 0.5, 1, 1, 5, 15
FM Deviation, kHz 5, 20, 100, 300
Frequency of PWM signal, Hz 1, 10, 40 и 100
PWM Duty cycle 1, 5, 10
“IR” emitter
Wave length, nm 940
Subcarrier frequency range, kHz 0.01- 5000
Stray harmonics, dBm 30
Output power, mW 0.5
Modulation AM, FM, DSSS
Modulation frequency, kHz 0.5, 1, 5, 10, 15
АМ depth, % 15
FM Deviation, kHz 5, 20, 100, 300
Frequency of PWM signal, Hz 1, 10, 40 и 100
PWM Duty cycle 1, 5, 10

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
11
"LF" socket
Socket Symmetrical
Frequency range, kHz 0.01-120
Maximum output power, W 0.7 (power supply),
0.3 (internal battery)
Power levels, % 7.5, 14, 20, 32, 50, 65, 80, 100
Impedance, Ω 8
Frequency-tuning step, kHz 1, 10, 100, 1000
Octave filters frequency values, Hz 32, 63, 125, 250, 500, 1000,
2000, 4000, 6000, 16000, 31500
63000
Third octave filters frequency values, Hz 32, 40, 50, 63, 80, 100, 125,
160, 200, 250, 315, 400, 500,
630, 800, 1000, 1250, 1600,
2000, 2500, 3150, 4000, 5000,
6300, 8000, 10000, 12500,
16000, 20000, 25000, 31500,
40000, 50000, 63000, 80000,
100000,
Nonlinear distortion, no more than, % 1
Modulation AM, FM, DSSS
Modulation frequency, kHz 0.5, 1, 1, 5, 15
АМ depth, % 15
FM Deviation, kHz 5, 20, 100, 300
Frequency of PWM signal, Hz 1, 20
PWM Duty cycle 1, 5, 10
Magnetic field emitter «MF»
Equivalent magnetic moment of magnetic field source with frequency 1kHz, A*m2
Power levels 100% 2*10-4
7.5% 2*10-5
Power
Power supply Li-Polymer battery, 2.2A/h or 220V
power supply
Maximum current consumption, mA 500

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
12
Main module dimensions, mm 110X60X28
4 LIFE TIME AND MANUFACTURER’S WARRANTY
4.1 Life time
Recommended life time is 7 years from the day of delivery to the customer.
4.2 Manufacturer's warranty
4.2.1 Manufacturer warranties that IPS121 matches technical requirements as long as consumer
will follow exploitation, transportation and storage regulations stated in this instruction.
Warranty period - one year from the day of delivery to the customer.
4.2.2 During warranty period manufacturer will provide free of charge repairs as long as consumer will
follow exploitation, transportation and storage regulations stated in this instruction.
5 CERTIFICATE OF ACCEPTANCE
IPS121 device. Certified№_____________ is manufactured according to the technical requirements,
accepted and verified as working unit.
Stamp Place
______________
year, month, day

TECHNICAL DETAILS AND OPERATION INSTRUCTIONS FOR IPS121
13
WARRANTY CARD
CARD №1
For warranty repair (maintenance)
IPS121
Serial ____________________ Manufactured ________________
Manufacturer's stamp
Sold ___________________________________ Date “ ” ________
(vendor's identification)
Salesman __________________ Vendor's stamp
(signature)
CARD STUB №1
For warranty repair (maintenance) IPS121
Serial ______________ Date ________________
Executor _______________________________
(Family name, signature)
Table of contents