Iridium Arc Bar Pro 1215 IP65 12x15W RGBW LED User manual

iridium
Arc Bar Pro 1215 IP65 12x15W RGBW LED
Product code: 113531

1
Product Overview
DMX-IN POWER-IN MENU DOWN UP ENTER POWER-OUT DMX-OUT

2
Mechanical Specification
140mm
1017mm
454.01mm
215.3mm
60.62mm
68.5mm
85mm

Packaging: Thanks for your purchasing the AH019A. All the lights have been checked
and are in excellent operating condition. Please check the shipping carton first. Because
there maybe damage occurred during the shipment. Then check the lights carefully and
be sure that the light is intact and works normally. In the event damage has been found,
spare parts are missing or the lights works abnormally, please contact us for further
instructions. And please don’t return the light to the dealer before contacting us.
Introduction:The AH019A has four operating modes: DMX mode, Auto mode,
Master/Slave mode. And the light has seven DMX channel. DMX channel is including 3
channel, 7 channel, 11 channel, 48 channel and 52 channel. You can see 13 kinds of
shows when you open the Auto mode .All then all the lights in Master/Slave mode will run
following the one in Auto mode. Using fog or special effect smoke, you can see better
showing effect.
Warning!
1.For the sake of preventing the risk of electrical shock or fire.
2.Don’t look directly at the opening lights all the time, or it may damage your eyes.
3

Features
4
● Light Source: 12*15W, 4 in 1 RGBW LEDs
● Lens:10*45°/8°/25°/40°
● Power consumption: 160W
● Voltage: AC 110-230V 50/ 60Hz
● Run mode: DMX 512 /Master Slave /Auto Run
● DMX channels: 3, 7, 11, 48 & 52 CH
● Built-in Effect: color mixing, variable color chasing, strobing and fading
● Fan controlled by PWM waves
● 4 dimmer curves
● TFT displayer with four buttons
● Material: Aluminum body
● IP65
● Temperature: -20°C~40°C
● Dimension:1017×140×216mm
● N.W: 9.1 KG
● G.W: 10.4KG
DOWN
9
6
3
8
5
2
7BG
W
R
4
1
STROBE
0
UP
SOUND
2
SOUND
1
SPEED
AUTO
2
AUTO
1
SLAVEDMX
Accessory
① Barndoor x 1 (purchase separate) ④DMX cable x1
②Magnetic frost filter x 1 (purchase separate) ⑤User manual x 1
③Power cable x 1 ⑥ IR Controller x 1
AH019A
QUAD LED BAR 12K
PleaseNote: Specifications and improvements in the design of this unit and this manual are subject to change without any
priorwritten notice.
Pleaseread carefully before use
User manual
①
②
③ ④ ⑤ ⑥

5
MENU DOWN UP ENTER
Displayer introduction
①
DMX
Key lock open
temp:043
DMX
[ADDRESS ]
001
1. DMX means the light is in the DMX mode.Similarly,SLAVE means the light is in the
SLAVE mode.
2. The color of the point shows the condition of signal transmission. Green represents
the good condition, while red represents the signal is interrupted.
3. The item shows the working temperature of the light.When the working temperature
exceeds the max temperature,the color of the letters and number will change from white
to yellow.
4. This item shows the menu you selected.
5. This item shows the condition of key lock. “Key lock open” means the key lock is
open.And “Key lock off” means the key lock is close.
④
⑤
② ③

Programme Menu
6
DMX
CHANNEL
007
CHANNEL
011
CHANNEL
003
DMX Curve
Stage/TV
Standard
Archited
Theatre
DMX Hold
Slave
Blackout
DMX State
Speed
Red
Green
Blue
White
Auto
Auto Mode
Static Color
13
1
31
1
Slave Mode
ADDRESS
001
Color
63
1
Strobe
20
0
CHANNEL
048
CHANNEL
052
ADDRESS
512
DMX CHANNEL

7
CCT
2700K
8000K
Set up
Dimmer ALL
White Blance
Remote
000
255
ON
OFF
Key lock
OFF
5s
Display
ON
30s
Max temp Password up down up down
000
255
red
green
blue
white
Info
Factory Reset
Wireless
Passcode
ON
OFF
up down up down
00000h - 0MWorking time
V.1.2Software Ver
V.1.0Hardware Ver
RDM UID

DMX control mode
8
Channel
1Hue
2Saturation
3Value (Brightness)
3CH
Value Function
0-255
0-255
0-255
1
Red dimmer
Master Dimming(0~100%)
Dimmer curve
2
3
4
5
6
7
1
2
3
4
5
6
7
8
9
10
11
7CH
11CH
0-255
Green dimmer
Blue dimmer
White dimmer
Strobe
Master Dimming(0~100%)
Dimmer curve
Red dimmer
Green dimmer
Blue dimmer
White dimmer
Strobe
none
Marco Color
CCT
none
auto 1
auto 2
auto 3
auto 4
auto 5
auto 6
auto 7
auto 8
auto 9
auto 10
auto 11
auto 12
auto 13
Speed
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-7
8-255
0-255
0 - 8
9 - 27
28 - 47
48 - 67
68 - 87
88 - 107
108 -127
128 - 147
148 - 167
168 - 187
188 - 207
208 - 227
228 - 247
248 - 255
0 - 255

9
10
48CH
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
48CH
52CH
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Red
Green
Blue
White
Master Dimming(0~100%)
Dimmer curve
Auto
Speed
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
45
46
47
48
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

9
10
48CH
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
48CH
52CH
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Red
Green
Blue
White
Master Dimming(0~100%)
Dimmer curve
Auto
Speed
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
45
46
47
48
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

11
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
Red
Green
Blue
White
Red
Green
Blue
White
Red
Green
Blue
White
41
42
43
44
45
46
47
48
49
50
51
52
52CH
0--9
10--19
20--29
30--39
40--49
50--59
60--69
70--79
80--89
90--99
100--109
110--119
120--129
130--139
140--149
150--159
160--169
all Ids
Id1
Id2
Id3
Id4
Id5
Id6
Id7
Id8
Id9
Id10
Id11
Id12
Id13
Id14
Id15
Id16
170--179
180--189
190--199
200--209
210
211
212
213
214
215
216
217
218
219
220
221
222
Id17
Id18
Id19
Id20
Id21
Id22
Id23
Id24
Id25
Id26
Id27
Id28
Id29
Id30
Id31
Id32
Id33
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
Id34
Id35
Id36
Id37
Id38
Id39
Id40
Id41
Id42
Id43
Id44
Id45
Id46
Id47
Id48
Id49
Id50
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
Id51
Id52
Id53
Id54
Id55
Id56
Id57
Id58
Id59
Id60
Id61
Id62
Id63
Id64
Id65
Id66
Channel 52 (Id address set)

12
DMX-512 addressing with ID address
1. Follow instructions 1for DMX 512 addressing.
2. Activate ID addressing in each fixture by setting panel function “ID ON/OFF”toON.
“Settings” to “ID ON/OFF”to “ON” For every DMX 512 starting address the user can set 66
separate ID addresses. Set ID addresses in each fixture by setting panel function “ ID
address”to incremental values.(l.e. 1, 12, 24, 36 etc...) “Settings” to “address” to “01~66”.
DMX address: 012
ID address: 03
DMX address: 012
ID address: 02
DMX address: 012
ID address: 01
DMX address: 001
ID address: 03
DMX address: 001
ID address: 02
DMX address: 001
ID address: 01
The figure above shows a simple DMX layout which has used three units at each DMX address. The
three units have different ID addresses which allows the user to collectively control the whole group of
units at that DMX address by setting Channel 10 to 0, or to control each unit independently by first
selecting the DMX address and then by using Channel 11 to locate the target ID address. (Note that
when using ID addresses it is also possible to activate ADAS which allows for even more option with
DMX addressing and control.
Slave Slave Slave Slave SlaveMaster
UPLOAD
First,set one light, which involves the program you have edited in EDIT menu
and want to upload, in Master mode,and others in Slave mode.
Then,connect all the lights with DMX cables.Finally,select the UPLOAD
menu of the Master light and press ENTER.All the programs edited in the
Master light will be uploaded to the Slave lights.

DMX MODE-In this menu,you can connect several pieces of lights with DMX
cable and control them with the control console.
Press ”ENTER” and then press “UP” or “DOWN” to ”Address” or “DMX Channel” and
press “ENTER”.
1) “XXX” will be showed in “Address”, "XXX” means the Address 001-512. You can
press “UP” or “DOWN”to select the address you desired.
2) “Channel [xx]” will be showed in “DMX Channels”, “XX” means 5 kinds of DMX
Channels Modes. You can press “UP” or “DOWN” to select the Channel Mode you
desired.
DIMMER CURVE-In this menu,you can choose the mode you desired.
1. Press ”ENTER” and then press “UP” or “DOWN” to “Dimmer Curve” to choose as
below modes.
2. Press “ENTER” you can see 4 items as below:
1) Standard
2) Stage/TV
3) Architec
4) Theatre
DMX STATE-In this menu,you can choose the DMX signal you desired.
1. Press “ENTER” and then press “UP” or “DOWN” to “DMX STATE”.
2. Press “ENTER” and you can choose “Blackout” or “DMX Hold”;”Blackout” means
cut off the DMX signal and “DMX Hold” means connect DMX signal.
SLAVE MODE-In this menu, you can choose one light as the MASTER light and
other lights in SLAVE Mode will run follow the MASTER light.
1. Press “ENTER” and then press “UP” or “DOWN” to “SLAVE Mode”.
2. Press “ENTER” and “SLAVE” will be showed, then press “ENTER” to choose.
AUTO MODE-In this menu, you can choose your desired AUTO Mode and
adjust the running speed.
1. Press “ENTER” and then press “UP” or “DOWN” to “AUTO MODE”.
2. Press “ENTER” you can see 2 items as below:
1) SPEED - It provides “01-31” for you choose.
2) AUTO MODE - It provides “AUTO 1- AUTO 13” for you choose.
STATIC COLOR-In this menu,you can choose the modes you need.
1. Press “ENTER” and then press “UP” or “DOWN” to “AUTO MODE”.
2. Press “ENTER” you can see 6 items as below:
1) RED
2) GREEN
3) BLUE
4) WHITE
5) COLOR - You can choose “1-63” in this menu.
6) STROBE - You can choose “0-20” in this menu.
13

CCT-In this menu, you can choose the brightness you desired.
1. Press “ENTER” and then press “UP” or “DOWN” to “CCT”.
2. Press “ENTER” you can chooose from “2700K” to “8000K” as you need.
SET UP-In this menu, you can adjust the values of the function.
1. Press “ENTER” and then press “UP” or “DOWN” to “SET UP”.
2. Press “ENTER” and there has 6 options,then press “UP” or “DOWN” to choose the
value you desired as below:
1) IR - You can press “ON” or “OFF” to choose whether you need to controll by this
mode.
2) Dimmer All - You can adjust the brightness of colors.
3) Wihte Balace - You can select “RED” “GREEN” “BLUE” “WHITE” you need.
4) Key Lock - You can choose “5s” or “OFF” to make the Key Lock turn on or off.
5) Display - You can choose “ON” or “30s” to make the position of the light screen.
6) Max temp - You can set the your desired Max working temperature of the light with
passcode in this menu.When the working temperature beyond max temperature of
default settings, the color of letter “Temp XX” will show the color from white to
yellow.Meanwhile, the light will adjust the working temperature automatically.
INFORMATION-In this menu, you can learn about the information of
RDM,software,hardware and working time of the light.
1.Press “ENTER” and then press “UP” or “DOWN” to “INFORMATION”.
2.Press “ENTER” and you can see 3 items as below:
1) RDM - It shows RDM information.
2) Hardware - It shows the Hardware information.
3) Software - It shows the Software information.
4) Working time - It shows the working time information.
FACTORY RESET-In this menu, you can reset all the value of the system.
1. Press “ENTER” and then press “UP” or “DOWN” to “FACTORY RESET”.
2. Press “ENTER” and enter the passcode to reset all the values of the system.
WIRELESS-In this menu,you can set the Wireless signal.
1. Press “ENTER” and then press “UP” or “DOWN” to “WIRELESS”.
2. Press “ENTER” and then choose “ON” or “OFF” to set the Wireless signal.”ON” is
turn on the signal and “OFF” is turn off the signal.
14

15
Mounting
When installing the unit, the trussing or area of installation must be able to
hold 10 times the weight without any deformation. When installing the unit
must be secured with a secondary safety attach-ment, e.g. and appropriate
safety cable. Never stand directly below the unit when mounting, removing,
or servicing the unit.
Overhead mounting requires extensive experience, including calculat-ing
working load limits, installation material being used, and perodic safety
inspection of all installation material and unit. If you lack these qualifcations,
do not attempt the installation yourself.
The installaiton should be checked by a skilled person once a year.
The AH019A is fully operational in three different mounting positions,
hanging upside-down from a ceiling, set on a flat level surface or mount the
unit on its side. Be sure this fxture is kept at least 0.5m away from any
flammable materials (decoration etc.). And you’d better use and install the
supplied safety cable as a safety measure to prevent accidental damage
and/or injury in the event the clamp fails (see next page).

16
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on
the other end.
3-PIN TO 5-PIN CONVERSION CHART
3-PINTO 5-PIN CONVERSION CHART
Note! If you use a controller with a 5 pin DMX output connector, you need to use a 5 pin
to 3 pin adapter. The chart below details a proper cable conversion:
caution:Do not allow contact between the ground and the fixture’s chassis ground. Grounding the
ground can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm
meter to verify positive pole and to make sure the pins are not grounded or shorted tothe shield or
each other.
DMX connector configuration
GROUND
Conductor
Ground/Shield
Data ( - ) signal
Data ( + )signal
Do not use
Do not use
3Pin Female (output)
Pin 1
Pin 2
Pin 3
5Pin Male (Input)
Pin 1
Pin 2
Pin 3
Do not use
Do not use

17
IR Controller
Power on/off button
DMX button,to control DMX
address when press this
button.It is channel mode
when double click.
Master-slave mode button.
Automatic mode button
Sound mode button
Up and down button,you can choose the
program that you need or numerical.
Strobe button
You can use these number button to adjust numerical in
any program mode.
Speed adjustive button
Color choosing button.
DOWN
9
6
3
8
5
2
7BG
W
R
7
R
98 57 BG WR
4
6
5
W
4
1
321
STROBE
STROBE
0
0
UP
DOWNUP
SOUND
2
SOUND
1
SOUND
2
SOUND
1
SPEED
SPEED
AUTO
2
AUTO
1
AUTO
2
AUTO
1
SLAVE
SLAVE
DMX
DMX

18
RDM is a wild version of the DMX512-A protocol, allowing dimming stations and other
control devices to be discovered through a DMX512 network, and then configuring,
status monitoring, and managing intermediate and line end devices.
It allows two-way communication between the lighting device or system controller and
the connected RDM compatible device through the standard DMX. This protocol will
allow these devices to be configured, monitored, and managed in a manner that does
not interfere with the normal operation of standard DMX512 devices that do not
recognize the RDM protocol.
Allow a controller or test device to find other devices that can be RDM, such as computer
lights or dimming cabinets, and remotely manage them through this connection
intelligence. Including the ability to remotely set the initial address of the DMX512, query
the device's errors or statistics, and achieve most of the configuration settings that are
usually done on the front panel of the device. RDM can run with the new RDM device or
any original DMX512 product on the same data link without any performance impact.
Since RDM runs on the first team DMX512 link, the only infrastructure upgrade required
by RDM is to upgrade the existing data distributor to implement a two-way mode to
support RDM.
The RDM information is transmitted through the first pair of DMX512 data channels.
RDM uses packets that include non-zero initial codes to start and control
communications. This alternating(rotating) session and waiting for indicative responses
is performed in a semi-duplex format. The second data pair is not used for any RDM
function.
Two-way data transmission-each vendor's equipment can exchange data, Art-net can
only transmit data, can not exchange with each other.
RDM---Remote Device Management
Its functions are as followed:
RDM
Enable & Run Factory Tests
Change DMX Address
Change Mode
Build fixture personalities
Fault Finding
Rig Check
Invert Pan & Tilt
Monitor SensorsName & Identify

IMPORTER
B&K LUMITEC
ZI – 2 Rue Alfred Kastler – 67850 Herrlisheim – France
www.bklumitec.com
This manual suits for next models
1
Table of contents
Other Iridium Dj Equipment manuals