IPU 40640 | Version 1 | February 2021Page 3
21.5” commercial-grade, non-touch smart LCD
display. Supports customisable and split screen
display messaging.
21.5” Enhanced all-in-one LCD display (IWC6256)
10” commercial-grade, PoE compatible touchscreen
LCD display including matching light bars. Supports
customisable and split screen display messaging.
10” LCD display with lightbars & PoE (IWC6255)
10” commercial-grade, non-touch smart LCD display.
Supports customisable and split screen display
messaging.
10” Smart all-in-one LCD display (IWC6254)
This installation guide applies to the following Display Screens
1DISPLAY SCREENS

IPU 40640 | Version 1 | February 2021Page 4
Before installing and connecting your Display Screen, we strongly recommend
that you first install your SafeCount Sensor(s) as per the SafeCount Installation
Guide.
When your SafeCount Sensor(s) are fully installed and ready to be powered up,
then you can refer to this guide to install your chosen accessories.
The following diagram shows, in general, how your Display Screen is connected to the
rest of your installed SafeCount System.
2SYSTEM OVERVIEW
PoE
SWITCH
SafeCount Primary Sensor
Installed at main entrance
WIFI
ROUTER
CAT 5/6
CABLE
MAINS
POWER
Display Screen (Various)
Installed at entrance facing
approaching customers
CAT 5/6
CABLE
MAINS POWER
(not required for
PoE version)

IPU 40640 | Version 1 | February 2021Page 5
Once you have connected your Display Screen to your SafeCount system and powered
the display on, follow these instructions to setup the display the SafeCount dashboards.
3DISPLAY SCREEN SETUP
1. Check the network connection
The IP address of the panel is displayed on the Home
screen. Make sure this is in the same range as the IP
address of the SafeCount system.
(Skip this step if connecting to the same PoE switch)
2. Connect to the SafeCount system
If touch-screen is not supported on your Display Screen, a USB mouse will need
to be connected to control the display.
http://yourserialnumber.local/safecount/
e.g. http://V4D-20200133.local/safecount/
2.1. Select Set Content
2.2 Enter your SafeCount system URL
This is the same URL used when originally setting up the SafeCount sensor.
To work out your SafeCount system URL, locate the SafeCount Sensor serial
number on the box (or back of SafeCount sensor) and use it in the below:
2.3 Press Set
2.4 Press Play

IPU 40640 | Version 1 | February 2021Page 6
© 2021 InfraRed Integrated Systems Limited (Irisys). No part of this publication may be reproduced without prior permission in writing from Irisys.
Whilst Irisys will endeavour to ensure that any data contained in this document is correct, Irisys do not guarantee its accuracy or accept liability for
any reliance on it. Irisys reserve the right to change the specification of the products and description without notice. Prior to ordering product please
check with Irisys for current specification details. Irisys products may be protected by patents. All brands, products and names are acknowledged
and may be trademarks or registered trademarks of their respective holders.
+44 (0)1604 594200
www.irisys.net
InfraRed Integrated Systems Ltd
Park Circle, Tithe Barn Way, Swan Valley
Northampton NN4 9BG
United Kingdom Part of Fluke since 2012
ⓒ2021 InfraRed Integrated Systems Limited (Irisys). No part of this publication may be reproduced without prior
permission in writing from Irisys. This document gives only a general description of the products and except where
expressly provided otherwise shall form no part of any contract. While Irisys will endeavor to ensure that any data
contained in this product information is correct, Irisys do not warrant its accuracy or accept liability for any reliance on it.
Irisys reserve the right to change the specification of the products and descriptions without notice. Prior to ordering
products please check with Irisys for current specification details. This product may be protected by patents US
5420419, US 5895233, US 6239433, US 6693279, US 6528788, US 7778855, EP 0853237, EP 1079349, GB 2476500, JP
3998788, JP 4376436; other patents pending, . All brands and product names are acknowledged and may be trademarks
or registered trademarks of their respective holders.
The Irisys SafeCount Sensor product contains software originating from Irisys and its suppliers that is licensed under the
Irisys Software License Agreement.
The Irisys SafeCount Sensor product also contains software from the open source community that is licensed under the
specific license terms applicable to that software. The full details of these license agreements, and warranties, are either
embedded in the product interface, or can be obtained on written request. In keeping with Irisys’ obligations to said
open-source licenses, this document should be taken as written offer, valid for three years, to provide a complete
machine-readable copy of the corresponding source code, distributed in accordance with the license, upon request. Any
written correspondence on this matter should be addressed to: Open Source Software Coordinator, Irisys, Tithe Barn
Way, Northampton NN4 9BG, United Kingdom.
4DISCLAIMER
This manual suits for next models
2
Table of contents