iRZ MC52iWDT User manual

iRZ MC52iWDT
GPRS class 10
GSM modem
USER MANUAL

GSM modem iRZ MC52iWDT
User Manual
2
Contents
1. Safety Requirements ...................................................................................................................................................3
2. General Information ....................................................................................................................................................4
2.1. Parameters .........................................................................................................................................................4
2.2. Configuration.....................................................................................................................................................4
2.3. Parameters .........................................................................................................................................................4
2.4. Exterior Appearance ..........................................................................................................................................6
2.5. Interfaces ...........................................................................................................................................................7
2.6. Modem Status Indication.................................................................................................................................10
3. Connection and Setting Up........................................................................................................................................11
3.1. Connection.......................................................................................................................................................11
3.2. Control, Restarting and Power Off ..................................................................................................................11

GSM modem iRZ MC52iWDT
User Manual
3
1. Safety Requirements
Restrictions for the usage of the device in the vicinity of other electronic devices:
•turn off the modem in hospitals or in the vicinity of medical equipment (e.g.
cardiostimulators, hearing aids). It can cause interference for medical equipment;
•turn off the modem in aircrafts. Take measures against accidental activation;
•turn off the modem in the vicinity of gas-filling stations, chemical enterprises, blasting
work places. It can cause interference to technical devices;
•at a short range the modem may cause harmful interference to TV and radio receivers.
Prevent the modem from dust and moisture.
Improper use deprives you of all warranty claims.

GSM modem iRZ MC52iWDT
User Manual
4
2. General Information
2.1. Parameters
The modem iRZ MC52iWDT — is a structurally accomplished GSM modem designed for
reception and transmission of data, text messages and telecopies. It is excellently adjusted both for
mobile Internet Access and for industrial applications — telemetry, wireless data collection from
sensors, remote surveillance, monitoring and signaling. The control is performed by means of
standard AT commands. The modem is equipped with light-emitting diodes (LEDs) enabling to
monitor the status of connection.
This modem includes function of unconditional actuation with interval of 24 hours.
2.2. Configuration
Complete set of the GSM modem MC52iWDT:
•modem iRZ MC52iWDT,
•label,
•factory box.
2.3. Parameters
Basic parameters:
•frequency ranges: GSM 900/1800 mHz or 850/900/1800/1900 mHz (depends on the
GSM module);
•output capasity:
o2W (class 4 for EGSM 850/900),
o1W (class 1 for GSM1800),
•GPRS class 8/10 (depends on the GSM module);
•TCP/IP suit available through AT commands;
•MC class B;
•CSD up to 14.4 kbps;
•USSD;
•SMS;
•voice transmission;
•fax group 3: class 1.
Power supply:
•power supply voltage from 9 to 28 V;
•absorbed current not more than:
owith power supply voltage +12 V – 200mA;
owith power supply voltage +24 V – 100mA.

GSM modem iRZ MC52iWDT
User Manual
5
Physical parameters:
•size not more than 69х74х33 mm,
•weight not more than 100 g.,
•operating-temperature range from -50°Сto +65°С,
•storage temperature range from -50°Сto +85°С.
Interfaces:
•connector RJ11 for power supply connection,
•connector RJ11 for audio interface connection,
•connector DB9 for connection of the data cable RS-232,
•connector FME for GSM antenna connection.

GSM modem iRZ MC52iWDT
User Manual
6
2.4. Exterior Appearance
The modem iRZ MC52iWDT is a compact device completed in a plastic housing. The external
appearance is represented on Fig.2.4.1 and Fig.2.4.2.
Рис.2.4.1 Вид спереди.
4
3
2
1
7
6
5
Fig.2.4.2 Back view.
On the figures the digits signify the following:
1. connector RJ11 for audio interface connection,
2. network LED indicator,
3. SIM card tray,
4. SIM card tray extracting button,
5. connector DB9 for connection of the data cable RS232,
6. connector RJ11 for power supply connection,
7. connector FME for GSM antenna connection.

GSM modem iRZ MC52iWDT
User Manual
7
2.5. Interfaces
2.5.1. Connector DB9 (RS232)
The connector is used for connection to the control device, exchange protocol RS232.
9 8 7 6
5 4 23 1
Fig.2.5.1 Connector DB9
Table 2.5.1 Purpose of the connector pins.
Pin Signal Direction Purpose
1DCD Mode
m
-PC Availabilit
y
of carrier wave
2RXD Mode
m
-PC Data reception
3TXD PC-Modem Data transmission
4DT
R
PC-Modem Availabilit
y
of data receiver
5GND
g
eneral S
y
stem housin
g
6DS
R
Mode
m
-PC Readiness of data
7 RTS PC-Modem Request for transmissio
n
8 CTS Mode
m
-PC Availabilit
y
of transmission
9 RI Mode
m
-PC Call si
g
nal

GSM modem iRZ MC52iWDT
User Manual
8
2.5.2. Power supply connector RJ11
The connector is used for connection of electric power supply.
6
1
Table 2.5.2 Purpose of power supply connector pins.
Contact Signal Purpose
1 + 12V Positive pole of DC supply voltage. Protected with a fuse and the
protection circuit against voltage-surge (with voltage infeed rate
more than 30V) and incorrect polarity.
2 not used
3 EMERGOFF Emergency shutdown
4 STARTING Trigger a modem
5 not used
6 GND System housing

GSM modem iRZ MC52iWDT
User Manual
9
2.5.3. Audio Interface Connector RJ11
4 5 6321
Fig.2.5.3 Connector RJ11
Таблица 2.5.3 Purpose of the power supply connector pins.
Contact Signal Purpose
1 MICP microphone input and microphone power supply not inverse
2 SPKP phone output not inverse
3 SPKN phone output inverse
4 MICN phone input inverse

GSM modem iRZ MC52iWDT
User Manual
10
2.6. Modem Status Indication
LED indication is provided in the modem for connection status indication.
Table 2.6.1 Connection status indication
Indication mode Operation mode
Turned off Modem is turned off or there is an emergency situation
600 ms on / 600 ms
off
Modem is not registered in the network
75 ms on / 3 s off Modem is registered in the network
75 ms on / 75 ms off /
75 ms on / 3 s off
GPRS connection is installed
500 ms on / 50 ms off Data transmission is underway

GSM modem iRZ MC52iWDT
User Manual
11
3. Connection and Setting Up
3.1. Connection
Before feeding the power supply you need to install the SIM card in the modem (the SIM card
must be enabled). To do this, you need:
•to extract the SIM tray by pressing the SIM tray extract button (Fig. 2.4.1);
•to install the SIM card into the SIM tray;
•to insert the SIM tray with the SIM card into the modem.
No strong physical efforts must be applied while installing the SIM card.
Connect the GSM antenna to the antenna connector, as well as the commutating cable (RS232).
Feed power supply to the modem through the connector RJ11 (Fig. 2.4.2).
Note: GSM antenna, data cables and electrical power unit are not included in the complete set
configuration.
After the power supply feeding, registration occurs automatically, which is signaled by the green
indicator frequent flashing. After the registration is completed, the modem jumps to the operating
mode, the green indicator flashes less frequently (Table 2.6.1).
3.2. Control, Restarting and Power Off
The modem control is performed by standard AT commands. For additional information and
support visit the manufacturer’s site – www.radiofid.ru.
Modem restarting can be carried out by the following ways:
•by the program method through AT commands,
•by eight jumpings of the DTR COM port line into passive state (DTR < 3V), duration of
pulses and the pauses between the pulses must lie within the range 100-500 ms,
•by temporary power-off.
The modem can be powered off using the following ways:
•by the program method, using AT commands (escape to the power standby mode);
•directly by power-off.
•signal EMERGOFF (emergency shutdown) - go and find a high level (from 5V to 27V) is
not less than 20 ms. Use EMERGOFF signal only when there is a serious problem when
more than 5 seconds, there is no response from the modem. The alarm EMERGOFF leads
to the loss of all data stored in volatile memory GSM module;
After power-off made by means of AT commands, the modem escapes to the power standby
mode (minimum power consumption). Escaping from the power standby mode is performed upon
the DTR of the COM port.
Every 24 hours is an absolute reset the modem. When restarting the GSM module in the modem off
for food. This function can not be disabled. Restart interval depends on the ambient temperature, and
can vary by 20-30 minutes.
Table of contents
Other iRZ Modem manuals
Popular Modem manuals by other brands

2N Telekomunikace
2N Telekomunikace 2N SmartCOM quick guide

Zoom
Zoom 3GM1073 quick start guide

US Robotics
US Robotics 56K SERIAL CONTROLLER FAXMODEM installation guide

PROLiNK
PROLiNK 1456PVA user manual

Amit
Amit IDG120-C6U01 installation guide

Patton electronics
Patton electronics RocketLink 3202 Getting started guide

Spectrum
Spectrum E31U2V1 Quick installation guide

EchoStar
EchoStar HUGHES HT1 00 Series Replacement guide

Linksys
Linksys Fibe Internet reference guide

TRENDnet
TRENDnet TFM-PCIV92A - DATA SHEETS Installation

Sierra Wireless
Sierra Wireless Airlink GX450 quick start guide

ELPRO
ELPRO 945U-E installation guide