iSens makseNSE ILOGGER CASE User manual

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
2 / 11
Patent Information
iSens - Electronica Lda. owns the intellectual property rights over the Indexor
technology described in this document.
Warranty
All products supplied by iSens - Electronica Lda. are covered by our 2-year warranty.
Copyright
© This manual shall not be copied (partially or totally), reproduced, in any form, or translated
into another language without prior permission from iSens - Electronica Ltd. The
manufacturer reserves the right to change the information in this manual without notice.
Images in this manual are illustrative only and may not be an accurate representation of the
equipment itself.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
3 / 11
FCC Regulatory info:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
No changes shall be made to the device without the manufacturer’s permission as this may
void the user’s authority to operate the device.
RF Exposure Information
iLogger Case 4A
The iLogger Case 4A complies with FCC RF radiation exposure limits set forth for an
uncontrolled environment. The iLogger Case 4A complies with the safety requirements for
RF exposure in accordance with FCC Part 2.1093 for portable use conditions.
iLogger Case 2 and iLogger Case 4
The iLogger Case 2 and iLogger Case 4 comply with FCC RF radiation exposure limits set
forth for an uncontrolled environment. The iLogger Case 2 and iLogger Case 4 comply with
the safety requirements for RF exposure for mobile (>20 cm) use conditions in accordance
with FCC rule part 2.1091.
Contains FCC ID: 2AC7Z-ESP32WROOM32E and Contains FCC ID: R7T1101102.
ISED Canada Regulatory info:
This device complies with ISED’s licence-exempt RSS standard(s). Operation is subject to
the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Informations réglementaires d'ISED Canada:
Ce dispositif est conforme à la norme RSS exemptée de licence de l’ISED. L’opération est
soumise aux deux conditions suivantes:
(1) ce dispositif peut ne pas causer d’interférence, et
(2) ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent
causer le fonctionnement indésirable de l’appareil.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
4 / 11
RF Exposure Information
iLogger Case 4A
The iLogger Case 4A complies with ISED Canada RSS-102 radiation exposure limits set
forth for an uncontrolled environment. The iLogger Case 4A complies with the safety
requirements for RF exposure in accordance with RSS-102 Issue 5 section 2.5.1 for portable
(≤20 cm) use conditions.
Le iLogger Case 4A est conforme aux limites d'exposition au rayonnement CNR-102 Canada
ISDE établies pour un environnement non contrôlé. Le iLogger Case 4A est conforme aux
exigences de sécurité pour l'exposition aux RF conformément à la norme CNR-102 édition 5
section 2.5.1 pour les conditions d'utilisation portables (≤20 cm).
iLogger Case 2 and iLogger Case 4
The iLogger Case 2 and iLogger Case 4 comply with ISED Canada RSS-102 radiation
exposure limits set forth for an uncontrolled environment. The iLogger Case 2 and iLogger
Case 4 comply with the safety requirements for RF exposure in accordance with RSS-102
Issue 5 section 2.5.2 for mobile (>20 cm) use conditions.
Contains IC: 21098-ESPWROOM32E and Contains IC: 5136A-1101102.
Le iLogger Case 2 et iLogger Case 4 sont conforme aux limites d'exposition au rayonnement
CNR-102 Canada ISDE établies pour un environnement non contrôlé. Le iLogger Case 2 et
iLogger Case 4 sont conforme aux exigences de sécurité pour l'exposition au RF
conformément à la norme CNR-102 édition 5 section 2.5.2 pour les conditions d'utilisation
mobile (>20 cm).
Le iLogger Case 2 et iLogger Case 4 contiennent IC: 21098-ESPWROOM32E y contiennent
IC: 5136A-1101102.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
5 / 11
1. Intended Use
The iLogger automatically records data on the iRack’s RFID to monitor data such as impacts,
temperature and time in the case. This data is then accessible in an Indexor System Standard.
2. System Components
Isothermic Bag with velcro fasteners Isothermic EPP Box

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
6 / 11
2.1. Absorbent pads
The iLogger is equipped with absorbent pads to contain any spillage that may occur. In the
event of a spill, carefully remove the pads and dispose of them in accordance with local
regulations and guidelines for potentially biohazardous substances.
3. Instructions
1. Batteries lid
2. Display
3. Status button
3.1. Placing or replacing the batteries
Replacing with the incorrect battery type may result in a hazard to the equipment.
Please check the Technical Specifications table for suitable battery types.
1- With the open iLogger, turn the batteries lid anti-clockwise.
2- Gently tilt the case so you can remove the batteries.
3- Insert new batteries with the positive (+) pole as indicated on the batteries lid.
4- Turn the lid clockwise to secure the batteries in place properly.
Do not dispose of batteries in a fire. Please follow local environmental applicable
regulations.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
7 / 11
3.2 Handling Procedures
1. Place the iRacks correctly to keep the samples from moving as much as possible.
2. After placing the iRack, check if it has been correctly detected by pushing the status
button to activate the display.
3. Place up to 5 Ice packs using the side slots and on top of the iRacks to decrease the
internal temperature.
4. Close the EPP Box correctly.
5. Seal the external bag with the Velcro fastener.
3.3 Display Information
Battery level
Occupied slot
Temperature
Time interval for
temperature recording
[min]
Serial number

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
8 / 11
5. Troubleshooting
This equipment was designed to be reliable. In case of any issues, please check the product
guide accessible at indexorsystems.com. For further assistance, please get in touch with
support@maksense.com.
6. Safety Precautions
The iLogger Case was designed with safety concerns. However, avoid shaking the iLogger
Case or placing it on an unstable surface to ensure accident-free operations.
Maintenance
The iLogger System does not require special maintenance.
Do not try to perform any maintenance operations on the iLogger Case.
Do not disassemble, modify or repair the iLogger Case
Environmental Information
This symbol on the product indicates that it is covered by Directive 2002/96/EC
(Waste Electrical and Electronic Equipment). The crossed-out dustbin indicates that
waste electrical and electronic equipment must not be disposed of with unsorted
household waste and that it must be disposed of separately.
Disposal must be carried out in accordance with local environmental regulations on waste
disposal. For information about the recovery and recycling of this product, please contact the
equipment supplier.
The correct disposal of the equipment helps avoid dangerous or detrimental effects on
human health and the environment.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
9 / 11
7. Cleaning and disinfection
Never use acids or caustic chemicals to clean.
Avoid spilling liquids near the display of the iLogger Case.
Before starting the cleaning process, please remove the absorbent pads.
The iLogger can be cleaned with a soft cloth slightly moistened with ethyl alcohol (70%).
8. Compliance with transport standards UN3373
The procedures for transporting biological samples are in accordance
with transport standard UN3373 –Cat. B –Packing instructions P650.

iLogger Case
User Manual
Last modification:
February 02, 2023
Version:
7.0.3
Author:
iSens –Electronica, Lda
Page:
11 / 11
10. Technical Specifications
Model
iLogger Case 4/4A
iLogger Case 2
Dimensions
420 [L] x 420 [W] x 370 [H] mm
460 [L] x 325 [W] x 370 [H] mm
Max. number of
Samples carried
240
120
Ice pack slots
5
2
Mechanical resistance
1100 kPa
Thermal conductivity
0.023 W/mK
Weight
3.4 Kg
3.2 Kg
Temperature Sensor
(TSYS01)
-40 °C to 125 °C (+/-0.1 °C)
Time interval for
temperature
recording*
5 minutes
G-force impact sensor
(SQ-ASE-060)
>60 G
Power Source
3 to 4 x Type C non-rechargeable dry cell alkaline batteries
Outdoor use
the equipment is not intended to be constantly subjected to an outdoor
environment
Operating
Temperature Range
-5 to 45Cº
Operating humidity
maximum relative humidity 80 % for temperatures up to 31 °C
decreasing linearly to 50 % relative humidity at 40 °C
Suitable for use in wet locations
Operating pollution
degree
PD2
IP Rating
Not rated
Maximum Altitude
3 000 Meters
Regulatory
Compliance:
WPC, RCM, MIC, TDRA, SASO,
FCC, IC, CE, ROHS, IEC 61010-
1, cULus
(Only applicable to iLogger Case 4A)
FCC, IC, CE, ROHS, IEC 61010-1,
cULus
Table of contents