Itm CONSTRUCTION GC Series User manual

www.itmtools.com.au
Ver: 1.6
OPERATOR’S MANUAL
PETROL GENERATOR
GC SERIES
MODELS: GC4000, GC6800, GC8100, GC10000
TO PREVENT SERIOUS INJURY OR DAMAGE TO YOUR GENERATOR, READ
AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE
! !
CONSTRUCTION SERIES

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
LIMITED WARRANTY
Industrial Tool & Machinery Sales (hereinafter referred to as ITMS) will, within twelve (12) months
from the original date of purchase, repair or replace any goods found to be defective in materials or
workmanship.
This warranty is void if the item has been damaged by accident, neglect, improper service or other causes
not arising out of defects in materials or workmanship. This warranty does not apply to machines and/
or components which have been altered, changed, or modified in any way, or subjected to overloading
or use beyond recommended capacities and specifications. Worn componentry due to normal wear and
tear is not a warranty claim. Goods returned defective shall be returned prepaid freight to ITMS or agreed
repair agent, which shall be the buyer’s sole and exclusive remedy for defective goods. ITMS accepts no
additional liability pursuant to this guarantee for the costs of travelling or transportation of the product or
parts to and from ITMS or the service agent or dealer, such costs are not included in this warranty.
Our goods come with guarantees which cannot be excluded under the Australian Consumer Law.
You are entitled to replacement or refund for a major failure and to compensation for other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail
to be of acceptable quality and the failure does not amount to a major failure.
THE MANUFACTURER RESERVES THE RIGHT TO MAKE IMPROVEMENTS AND
MODIFICATIONS TO DESIGN WITHOUT PRIOR NOTICE.
PRODUCTS IMPORTED AND DISTRIBUTED NATIONALLY BY:
INDUSTRIAL TOOL & MACHINERY SALES
18 BUSINESS ST, YATALA QLD 4207
F: 07 3287 1115 W: www.itmtools.com.au
TRADEMASTER
Magnetic Base Drilling Machines
Tools and Machinery
AIR
TABLE OF CONTENTS
Warranty .................................................................................................................. 2
Product Specifications ............................................................................................. 3
Safety Instructions ................................................................................................... 4
Unpacking ................................................................................................................. 6
Assembly .................................................................................................................. 7
Operation .................................................................................................................... 9
Maintenance ............................................................................................................ 22
Trouble Shooting ..................................................................................................... 28
Parts Lists & Breakdowns ........................................................................................ 29
Wiring Diagrams ...................................................................................................... 37
2www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
MODEL GC4000 GC6800 GC8100 GC10000
Part Number TM520-3400 TM520-5500 TM520-6500 TM520-8000
Voltage 240V ~ 50Hz 240V ~ 50Hz 240V ~ 50Hz 240V ~ 50Hz
KvA 4 6.8 8.1 10
Max. Power 3400W 5500W 6500W 8000W
Rated Power 3200W 5000W 6000W 7500W
Amps 14 20.8 25 30
Horse Power 8HP 13HP 15HP 17HP
Engine Type 4 Stroke 4 Stroke 4 Stroke 4 Stroke
Fuel Tank (L) 15 25 25 25
Fuel Type Ron 91 Ron 91 Ron 91 Ron 91
Engine Power cc 224 420 420 457
Noise @ 7Mtr (full load) 76dB(A) 78dB(A) 79dB(A) 80dB(A)
Running Time 50% Load 14 Hours 13 Hours 12 Hours 10 Hours
DC Power 12V 8.3A 12V 8.3A 12V 8.3A 12V 8.3A
AC outlets 1 x 15A (IP66) 2 x 15A (IP66) 2 x 15A (IP66) 2 x 15A (IP66)
Start System Electric
(Push Button)
Electric
(Push Button)
Electric
(Push Button)
Electric
(Push Button)
Remote Control Yes Yes Yes Yes
Pure Sine Wave THD<5% THD<5% THD<5% THD<5%
Alternator AVR AVR AVR AVR
Residual Current Device “RCD” Yes Yes Yes Yes
Oil Capacity 0.6L 1.1L 1.1L 1.1L
Recommended Oil 10W 30 10W 30 10W 30 10W 30
Low Oil Sensor Yes Yes Yes Yes
Wheel & Handle Kit Yes Yes Yes Yes
Weight 54Kg 83Kg 88Kg 95Kg
Thank you for purchasing your GC Series Generator. This generator is fitted with IP66
outlets and RCD meaning it is worksite compliant. With built-in Pure Sine Wave technology
(THD<5%), it’s also ideal for powering tools, domestic appliances and sensitive electronics.
Please read and understand the content of this manual for safety guidelines, start-up,
shutdown, operation, adjustment and maintenance instructions before using this product.
Take all possible precautions to protect your own safety and that of the people in the
immediate vicinity. Save this manual for future reference.
* (Automatic voltage regulator)
PRODUCT SPECIFICATIONS
3
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
GENERAL SAFETY RULES FOR OPERATION
Never use the generator in a location that is wet or damp. Never expose the generator to rain,
snow, water spray or standing water while in use. Protect the generator from all hazardous weather
conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.
Voltage produced by the generator could result in death or serious injury.
• Never operate the generator in rain or a flood plain unless proper precautions are taken to avoid
being subject to rain or a flood.
• Never use worn or damaged extension cords.
• Always have a licensed electrician connect the generator to the utility circuit.
• Never touch an operating generator if the generator is wet or if you have wet hands.
• Never operate the generator in highly conductive areas such as around metal decking or steel
works.
• Always use grounded extension cords. Always use three-wire or double-insulated power tools.
• Never touch live terminals or bare wires while the generator is operating.
• Be sure the generator is properly grounded before operating.
Never modify the generator.
Never operate the generator if it
vibrates at high levels, if engine
speed changes greatly or if the
engine misfires often.
Always disconnect tools or
appliances from the generator
before starting.
Never operate the generator if powered items overheat,
electrical output drops, there is sparking, flames or
smoke coming from the generator, or if the receptacles
are damaged.
Never use the generator to power medical support
equipment.
Always remove any tools or other service equipment
used during maintenance from the generator before
operating.
Petrol and petrol vapors are extremely flammable and explosive under certain conditions.
• Always refuel the generator outdoors, in a well-ventilated area.
• Never remove the fuel cap with the engine running.
• Never refuel the generator while the engine is running. Always turn engine off and allow the
generator to cool before refueling.
• Only fill fuel tank with petrol.
• Keep sparks, open flames or other form of ignition (such as match, cigarette, static electric source
away when refueling.
• Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a
sudden overflow of petrol and result in spilled petrol coming in contact with HOT surfaces. Spilled
fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag
properly. Allow area of spilled fuel to dry before operating the generator.
• Wear eye protection while refueling.
• Never use petrol as a cleaning agent.
• Store any petrol containers in a well-ventilated area, away from any source of ignition.
• Check for fuel leaks after refueling. Never operate the engine if a fuel leak is discovered.
Never operate the generator in an enclosed area. Engine exhaust contains carbon monoxide. Only
operate the generator outside and away from windows, doors and vents.
DANGER
WARNING
WARNING
WARNING NOTICE
!
!
4www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
ADDITIONAL SAFETY RULES FOR GENERATORS
Do not force the generator. Use the correct generator for your application. The correct generator will do
the job better and safer at the rate for which it was designed.
Do not use the generator if the engine switch does not turn it on and off. Any generator that cannot be
controlled with the switch is dangerous and must be repaired.
Know exactly how to use the generator correctly. Be thoroughly familiar with proper use of the equipment
and all engine controls, output receptacles, and connections. Know how to stop the engine quickly (see
“Stopping the Generator”).
Instruct operators. The engine owner must instruct all operators in safe engine set-up and operation.
Only trained adults should set up and operate the engine – Do not let children operate.
Intended use. Carefully read about and understand the intended use of this engine. Do not use for other
purposes, as unforeseen hazards or equipment damage may result.
Never operate, or let anyone else operate the generator while under the influence of alcohol, drugs, or
medication.
Do not operate the generator with damaged, missing, or broken parts.
Do not modify the generator in any way. Modifications can create serious safety hazards and will also
void the warranty.
Never attempt to modify the generator speed setting. The generator speed is preset for safe and optimal
performance of the generator. If speed needs adjusting, it must be done by factory authorised personnel.
Never attempt to connect external fuel sources in order to increase generator run time. Larger tank at
pressure or higher elevation will cause to leak from carburetor during operation. Fire or explosion could
result.
Always turn off generator and remove spark plug(s) or spark plug wire(s) before working on the
generator to prevent accidental starting. Always discharge the capacitor before working on the generator
head to prevent electrical shock. (See Maintenance & Repair section of this manual for instructions on
how to do this.)
The running of a generator gives off carbon monoxide, a poisonous gas that can kill you. You CAN NOT
smell it, see it, or taste it. Follow all instructions for site selection and positioning the generator, and
avoid inhaling the exhaust. If you start to feel sick, dizzy, or weak while using the generator, shut off the
generator and get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
5
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
UNPACKING
Always have assistance when lifting the
generator. The generator is heavy; lifting it
could cause bodily harm.
Tools required - B packing tape on top of the
carton.
1. Fold back top flaps to reveal the manual.
2. Remove the Wheel Kit Accessories cardboard
box.
3. Carefully cut two sides of the carton to remove
the generator.
WHAT COMES IN THE BOX
Manual (1)
Wireless Remote Starter (1) if any
Spark Plug Socket Wrench (1)
Wheel Kit Accessories Box if any
Funnel (1)
WHEEL KIT ACCESSORIES BOX
Open the Wheel Kit Accessories box and verify
the contents against the list right. If any parts are
missing, please locate an authorised.
1. Washer (2 used)
2. Flange Bolt M8 x16mm (4 used)
3. Hairpin Cotter Pin (2 used)
4. Wheel Axle Pin (2)
Wheel and Feet Kit Hardware
Avoid cutting on or near staples to prevent
personal injury.
CAUTION
! !
3
2
4
1
6www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
INSTALLING WHEELS TO FRAME
1. Insert axle pin through washer and wheel.
2. Install the wheel with axle pin through the
axle bracket on the frame. The eye of the
bolt should be facing toward the inside of the
generator.
3. Install the hairpin cotter through the axle pin to
lock it in place.
1 - Axle Bracket
2 - Hairpin Clip
3 - Axle Pin
4. Repeat previous steps on other wheel.
INSTALLING WHEELS AND FEET
BEFORE ASSEMBLING THE
GENERATOR, REVIEW THE SAFETY
SECTION STARTING ON PAGE 5.
CAUTION
Never lift the generator without
assistance. The generator is heavy
and lifting without assistance could
result in personal injury.
Never use the handles as a lifting point
to support the entire weight of the
generator. Only use the handles to move
the generator by lifting the handles and
using the wheels to move the generator.
Use caution when collapsing the
handles. Hands and ngers could get
caught and pinched.
NOTICE
Assembling the generator will require lifting the unit
on one side. Make sure all engine oil and fuel are
drained from the unit prior to assembling. Once
assembled, the wheel kit is not intended for on-
road use. The wheel kit is designed for use on this
generator only.
INSTALLING FEET TO FRAME
1. Place generator on a at surface.
2. Place a piece of cardboard or other soft material to
tip the generator onto, to protect the frame paint and
prevent the generator from sliding. Tip the generator
onto the side.
3. Install the mounting feet to the frame using the M8
ange bolts included.
1 - Mounting Foot
2 - Flange Bolts M8
1
2
Figure 1 - Assemble Mounting Feet to Frame
INSTALLING WHEELS TO FRAME
1. Insert axle pin through washer and wheel.
2. Install the wheel with axle pin through the axle
bracket on the frame. The eye of the bolt should be
facing toward the inside of the generator.
21
3
Figure 3 - Assemble Wheel to Frame
3. Install the hairpin cotter through the axle pin to lock it
in place.
1 - Axle Bracket
2 - Hairpin Clip
3 - Axle Pin
4. Repeat previous steps on other wheel.
ASSEMBLY
Figure 2 -Wheel Assembly
INSTALLING WHEELS AND FEET
BEFORE ASSEMBLING THE
GENERATOR, REVIEW THE SAFETY
SECTION STARTING ON PAGE 5.
CAUTION
Never lift the generator without
assistance. The generator is heavy
and lifting without assistance could
result in personal injury.
Never use the handles as a lifting point
to support the entire weight of the
generator. Only use the handles to move
the generator by lifting the handles and
using the wheels to move the generator.
Use caution when collapsing the
handles. Hands and ngers could get
caught and pinched.
NOTICE
Assembling the generator will require lifting the unit
on one side. Make sure all engine oil and fuel are
drained from the unit prior to assembling. Once
assembled, the wheel kit is not intended for on-
road use. The wheel kit is designed for use on this
generator only.
INSTALLING FEET TO FRAME
1. Place generator on a at surface.
2. Place a piece of cardboard or other soft material to
tip the generator onto, to protect the frame paint and
prevent the generator from sliding. Tip the generator
onto the side.
3. Install the mounting feet to the frame using the M8
ange bolts included.
1 - Mounting Foot
2 - Flange Bolts M8
1
2
Figure 1 - Assemble Mounting Feet to Frame
INSTALLING WHEELS TO FRAME
1. Insert axle pin through washer and wheel.
2. Install the wheel with axle pin through the axle
bracket on the frame. The eye of the bolt should be
facing toward the inside of the generator.
21
3
Figure 3 - Assemble Wheel to Frame
3. Install the hairpin cotter through the axle pin to lock it
in place.
1 - Axle Bracket
2 - Hairpin Clip
3 - Axle Pin
4. Repeat previous steps on other wheel.
ASSEMBLY
Figure 2 -Wheel Assembly
INSTALLING WHEELS AND FEET
BEFORE ASSEMBLING THE
GENERATOR, REVIEW THE SAFETY
SECTION STARTING ON PAGE 5.
CAUTION
Never lift the generator without
assistance. The generator is heavy
and lifting without assistance could
result in personal injury.
Never use the handles as a lifting point
to support the entire weight of the
generator. Only use the handles to move
the generator by lifting the handles and
using the wheels to move the generator.
Use caution when collapsing the
handles. Hands and ngers could get
caught and pinched.
NOTICE
Assembling the generator will require lifting the unit
on one side. Make sure all engine oil and fuel are
drained from the unit prior to assembling. Once
assembled, the wheel kit is not intended for on-
road use. The wheel kit is designed for use on this
generator only.
INSTALLING FEET TO FRAME
1. Place generator on a at surface.
2. Place a piece of cardboard or other soft material to
tip the generator onto, to protect the frame paint and
prevent the generator from sliding. Tip the generator
onto the side.
3. Install the mounting feet to the frame using the M8
ange bolts included.
1 - Mounting Foot
2 - Flange Bolts M8
1
2
Figure 1 - Assemble Mounting Feet to Frame
INSTALLING WHEELS TO FRAME
1. Insert axle pin through washer and wheel.
2. Install the wheel with axle pin through the axle
bracket on the frame. The eye of the bolt should be
facing toward the inside of the generator.
21
3
Figure 3 - Assemble Wheel to Frame
3. Install the hairpin cotter through the axle pin to lock it
in place.
1 - Axle Bracket
2 - Hairpin Clip
3 - Axle Pin
4. Repeat previous steps on other wheel.
ASSEMBLY
Figure 2 -Wheel Assembly
ASSEMBLY
Never lift the generator without assistance.
The generator is heavy and lifting without
assistance could result in personal injury.
Assembling the generator will require lifting
the unit on one side. Make sure all engine
oil and fuel are drained from the unit prior to
assembling. Once assembled, the wheel kit is
not intended for on-road use. The wheel kit is
designed for use on this generator only.
INSTALLING FEET TO FRAME
1. Place generator on a flat surface.
2. Place a piece of cardboard or other soft
material to tip the generator onto, to protect
the frame paint and prevent the generator from
sliding. Tip the generator onto the side.
3. Install the mounting feet to the frame using the
M8 flange bolts included.
1 - Mounting Foot
2 - Flange Bolts M8
Never use the handles as a lifting point to
support the entire weight of the generator.
Only use the handles to move the generator
by lifting the handles and using the wheels to
move the generator.
Use caution when collapsing the handles.
Hands and fingers could get caught and
pinched.
CAUTION
! !
NOTICE
7
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
1. Always make sure to attach the positive (+)
batterycable first (1) and then the negative (-)
cable second(2) (see Figure 4).
2. Securely tighten the positive (+) battery cable
(redboot) to the positive (+) battery post. Make
sure boot is over battery post.
ASSEMBLY
To avoid electric shock:
• ALWAYS connect the positive (+) battery
cable (red boot) first when connecting
battery cables.
• ALWAYS disconnect the negative (-)
battery cable (black boot) first when
disconnecting battery cables.
• NEVER connect the negative (-) battery
cable (black boot) to the positive (+) post on
the battery.
• NEVER connect the positive (+)battery
cable (red boot) to the negative (-) post on
the battery.
• NEVER touch both battery posts
simultaneously.
• NEVER place a metal tool across both
battery posts.
• ALWAYS use insulated or nonconducting
tools when installing the battery.
When you have finished using your generator,
ensure you disconnect the positive cable from
the battery prior to storage. Failure to do so
can cause the battery to discharge resulting in
sulfation of battery plates which is not covered
under warranty.
The electric start generator is equipped with
a battery charging feature. Once the engine
is running, a small charge is supplied to the
battery via the battery cables and will slowly
recharge the battery.
WARNING
! !
WARNING
! !
NOTICE
CONNECTING THE BATTERY
WARNING
To avoid electrics hock:
•ALWAYS connect the positive (+)
battery cable (red boot) rst when
connecting battery cables.
•ALWAYS disconnect the negative (-)
battery cable (black boot) rst when
disconnecting battery cables.
•NEVER connect the negative (-)
battery cable (black boot) to the
positive (+) post on the battery.
•NEVER connect the positive (+)
battery cable (red boot) to the
negative (-) post on the battery.
•NEVER touch both battery posts
simultaneously.
•NEVER place a metal tool across
both battery posts.
•ALWAYS use insulated or
nonconducting tools when installing
the battery.
1. Always make sure to attach the positive (+) battery
cable rst (1) and then the negative (-) cable second
(2) (see Figure 4).
1
2
Figure 4 - Battery Connection Order
1 - Positive (+) Battery Cable (Red)
2- Negative (-) Battery Cable (Black)
2. Securely tighten the positive (+) battery cable (red
boot) to the positive (+) battery post. Make sure boot
is over battery post.
ASSEMBLY
3. Carefully remove the protective wrapping around the
lug of the negative (-) battery cable (black boot).
4. Locate the black negative (-) cable attached to the
alternator case, route it to the negative (-) battery post.
See Figure 5 below for location of negative (-) cable.
1
Figure 5 - Locating Negative (-) Cable
5. Pull back the black boot and securely attach the
negative (-) battery cable (black boot) to the negative
(-) battery post as shown in Figure 4. Replace the
black boot so it protects the cable lug and battery
post.
NOTICE
The electric start generator is equipped with a battery
charging feature. Once the engine is running, a small
charge is supplied to the battery via the battery cables
and will slowly recharge the battery.
CONNECTING THE BATTERY
WARNING
To avoid electrics hock:
•ALWAYS connect the positive (+)
battery cable (red boot) rst when
connecting battery cables.
•ALWAYS disconnect the negative (-)
battery cable (black boot) rst when
disconnecting battery cables.
•NEVER connect the negative (-)
battery cable (black boot) to the
positive (+) post on the battery.
•NEVER connect the positive (+)
battery cable (red boot) to the
negative (-) post on the battery.
•NEVER touch both battery posts
simultaneously.
•NEVER place a metal tool across
both battery posts.
•ALWAYS use insulated or
nonconducting tools when installing
the battery.
1. Always make sure to attach the positive (+) battery
cable rst (1) and then the negative (-) cable second
(2) (see Figure 4).
1
2
Figure 4 - Battery Connection Order
1 - Positive (+) Battery Cable (Red)
2- Negative (-) Battery Cable (Black)
2. Securely tighten the positive (+) battery cable (red
boot) to the positive (+) battery post. Make sure boot
is over battery post.
ASSEMBLY
3. Carefully remove the protective wrapping around the
lug of the negative (-) battery cable (black boot).
4. Locate the black negative (-) cable attached to the
alternator case, route it to the negative (-) battery post.
See Figure 5 below for location of negative (-) cable.
1
Figure 5 - Locating Negative (-) Cable
5. Pull back the black boot and securely attach the
negative (-) battery cable (black boot) to the negative
(-) battery post as shown in Figure 4. Replace the
black boot so it protects the cable lug and battery
post.
NOTICE
The electric start generator is equipped with a battery
charging feature. Once the engine is running, a small
charge is supplied to the battery via the battery cables
and will slowly recharge the battery.
CONNECTING THE BATTERY
WARNING
To avoid electrics hock:
•ALWAYS connect the positive (+)
battery cable (red boot) rst when
connecting battery cables.
•ALWAYS disconnect the negative (-)
battery cable (black boot) rst when
disconnecting battery cables.
•NEVER connect the negative (-)
battery cable (black boot) to the
positive (+) post on the battery.
•NEVER connect the positive (+)
battery cable (red boot) to the
negative (-) post on the battery.
•NEVER touch both battery posts
simultaneously.
•NEVER place a metal tool across
both battery posts.
•ALWAYS use insulated or
nonconducting tools when installing
the battery.
1. Always make sure to attach the positive (+) battery
cable rst (1) and then the negative (-) cable second
(2) (see Figure 4).
1
2
Figure 4 - Battery Connection Order
1 - Positive (+) Battery Cable (Red)
2- Negative (-) Battery Cable (Black)
2. Securely tighten the positive (+) battery cable (red
boot) to the positive (+) battery post. Make sure boot
is over battery post.
ASSEMBLY
3. Carefully remove the protective wrapping around the
lug of the negative (-) battery cable (black boot).
4. Locate the black negative (-) cable attached to the
alternator case, route it to the negative (-) battery post.
See Figure 5 below for location of negative (-) cable.
1
Figure 5 - Locating Negative (-) Cable
5. Pull back the black boot and securely attach the
negative (-) battery cable (black boot) to the negative
(-) battery post as shown in Figure 4. Replace the
black boot so it protects the cable lug and battery
post.
NOTICE
The electric start generator is equipped with a battery
charging feature. Once the engine is running, a small
charge is supplied to the battery via the battery cables
and will slowly recharge the battery.
3. Install the hair pin cotter through the axle pin
to lock itin place.
1 - Axle Bracket
2 - Hairpin Clip
3 - Axle Pin
4. Repeat previous steps on other wheel.
5. Pull back the black boot and securely attach
thenegative (-) battery cable (black boot)
to the negative(-) battery post as shown in
Figure 4. Replace theblack boot so it protects
the cable lug and batterypost.
8www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
OPERATION
LOCATION SELECTION
Before starting the generator, avoid
exhaust and location hazards by verifying:
• You have selected a location to operate the
generator that is outdoors and well ventilated.
• You have selected a location with a level and
solid surface on which to place the generator.
• You have selected a location that is at least
15 feet (4.5 m) away from any building, other
equipment or combustible material.
• If the generator is located close to a building,
make sure it is not located near any windows,
doors and/or vents. WEATHER
Never operate your generator outdoors during
rain, snow or any combination of weather
conditions that could lead to moisture collecting
on, in or around the generator.
DRY SURFACE
Always operate the generator on a dry surface
free of any moisture.
NO CONNECTED LOADS
Make sure the generator has no connected
loads before starting it. To ensure there are no
connected loads, unplug any electrical extension
cords that are plugged into the control panel
receptacles.
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you
operate above sea level. Output will be reduced
approximately 3.5% for every 1000ft of increased
altitude from sea level. This is a natural
occurrence and cannot be adjusted by engine.
Increased exhaust emissions can also result due
to increased fuel mixture. Other issues include
hard starting, increased fuel consumption and
spark plug fouling.
Always operate the generator on a level
surface. Placing the generator on non level
surfaces can cause the generator to tip over,
causing fuel and oil to spill. Spilled fuel can
ignite if it comes in contact with an ignition
source such as a very hot surface.
Be sure the generator is properly connected to
earth ground before operating. The generator
must be grounded to prevent electrical shock
due to faulty appliances.
DANGER
! !
WARNING
! !
WARNING
! !
Only operate the generator on a solid, level
surface. Operating the generator on a surface
with loose material such as sand or grass
clippings can cause debris to be ingested by
the generator that could:
• Block cooling vents
• Block air intake system
Starting the generator with loads already
applied to it could result in damage to any
appliance being powered off the generator
during the brief start-up period.
NOTICE
NOTICE
9
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
OPERATION
CONNECTING THE GENERATOR TO A
BUILDING ELECTRICAL SYSTEM
It is recommended to use a manual transfer switch
when connecting directly to a buildings electrical
system. Connecting a portable generator to a
buildings electrical system must be made in strict
compliance with all national and local electrical
codes and laws, and be completed by a qualified
electrician.doors and/or vents.
ADDING / CHECKING ENGINE
FLUIDS AND FUEL
Before starting the generator, always check the
level of:
• Engine oil
• Petrol in the fuel tank
Once the generator is started and the engine gets
warm, it is not safe to add petrol to the fuel tank or
engine oil to the engine while the engine is running
or the engine and muffler are hot.
CHECKING AND / OR ADDING ENGINE OIL
Internal pressure can build in the engine
crankcase while the engine is running.
Removing the oil fill plug/ dipstick while the
engine is hot can cause extremely hot oil to
spray out of the crankcase and can severely
burn skin. Allow engine oil to cool for several
minutes before removing the oil fill plug/
dipstick.
Filling the fuel tank with petrol while the
generator is running can cause petrol to leak
and come in contact with hot surfaces that can
ignite the petrol.
WARNING
! !
DANGER
! !
The unit as shipped does not contain oil in the
engine. You must add engine oil before starting
the generator for the first time.
10 www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
OPERATION
ADDING GASOLINE TO THE FUEL TANK
WARNING
Never refuel the generator while the
engine is running.
Always turn the engine o and allow
the generator to cool before refueling.
Required Gasoline – Only use gasoline that meets the
following requirements:
•Unleaded gasoline only
•Gasoline with maximum 10% ethanol added
•Gasoline with an 87 octane rating or higher
Filling the Fuel Tank – Follow the steps below to ll the
fuel tank:
1. Shut o the generator.
2. Allow the generator to cool down so all surface areas
of the muer and engine are cool to the touch.
3. Move the generator to a at surface.
4. Clean area around the fuel cap.
5. Remove the fuel cap by rotating counterclockwise.
6. Slowly add gasoline into the fuel tank. Be very careful
not to overll the tank. The gasoline level should NOT
be higher than the ller neck (see Figure 7).
7. Install the fuel cap by rotating clockwise until
you hear a click, indicating the cap is completely
installed.
Figure 7 - Maximum Gasoline Fill Level
CAUTION
Avoid prolonged skin contact with
gasoline. Avoid prolonged breathing of
gasoline vapors.
BEFORE STARTING THE GENERATOR
BEFORE STARTING THE GENERATOR,
REVIEW SAFETY SECTION STARTING ON
PAGE 5.
Before attempting to start the generator,
verify the following:
•The engine is lled with engine oil. See Checking Engine
Oil on page 24.
•The generator is situated in a proper location (Location
Selection on page 15).
•The generator is on a dry surface (Weather and Dry
Surface on page 15).
•All loads are disconnected from the generator (No
Connected Loads on page 15).
•The generator is properly grounded the Generator
(page 15).
DANGER
Never use the generator in a location
that is wet or damp. Never expose the
generator to rain, snow, water spray or
standing water while in use. Protect the
generator from all hazardous weather
conditions. Moisture or ice can cause a
short circuit or other malfunction in the
electrical circuit.
Never operate the generator in an
enclosed area. Engine exhaust contains
carbon monoxide. Only operate the
generator outside and away from
windows, doors and vents.
NOTICE
The engine is equipped with a low oil shutdown switch. If the
oil level becomes low, the engine may shut down and not start
until the oil is lled to the proper level. Poor oil quality may
interfere with the operation of the low oil shutdown switch.
The owner of the generator is responsible to ensure the proper
oil level is maintained during the operation of the generator.
Failure to maintain the proper oil level can result in engine
damage.
NOTICE
Let engine stabilize and warm up for a few minutes before
adding load.
OPERATION
ADDING PETROL TO THE FUEL TANK
Required Petrol
Only use petrol that meets the
following requirements:
• Unleaded petrol only
• Petrol with maximum 10% ethanol added
• Petrol with an 87 octane rating or higher
Filling the Fuel Tank
Follow the steps below to fill the
fuel tank:
1. Shut off the generator.
2. Allow the generator to cool down so all surface
areas of the muffler and engine are cool to the
touch.
3. Move the generator to a flat surface.
4. Clean area around the fuel cap.
5. Remove the fuel cap by rotating
counterclockwise.
6. Slowly add petrol into the fuel tank. Be very
careful not to overfill the tank. The petrol level
should NOT be higher than the filler neck (see
Figure 7).
7. Install the fuel cap by rotating clockwise
until you hear a click, indicating the cap is
completely installed.
Never refuel the generator while the engine is
running.
Always turn the engine off and allow the
generator to cool before refueling.
WARNING
! ! Before attempting to start the generator,
verify the following:
• The engine is filled with engine oil.
• The generator is situated in a proper location.
• The generator is on a dry surface.
• All loads are disconnected from the generator.
• The generator is properly grounded.
Avoid prolonged skin contact with petrol. Avoid
prolonged breathing of petrol vapors.
CAUTION
! !
Never use the generator in a location that is
wet or damp. Never expose the generator
to rain, snow, water spray or standing water
while in use. Protect the generator from all
hazardous weather conditions. Moisture or ice
can cause a short circuit or other malfunction in
the electrical circuit.
Never operate the generator in an enclosed
area. Engine exhaust contains carbon
monoxide. Only operate the generator outside
and away from windows, doors and vents.
The engine is equipped with a low oil shutdown
switch. If the oil level becomes low, the engine
may shut down and not start until the oil is
filled to the proper level. Poor oil quality may
interfere with the operation of the low oil
shutdown switch.
The owner of the generator is responsible
to ensure the proper oil level is maintained
during the operation of the generator. Failure
to maintain the proper oil level can result in
engine damage.
Let engine stabilize and warm up for a few
minutes before adding load.
DANGER
! !
NOTICE
11
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
OPERATION
GENERATOR SET UP
PLANNING THE POWER LOAD
Plan your power load so that you do not exceed the generator’s rated capacity. To calculate the
running and starting wattage requirements for the devices you will be powering.
SET UP AS A PORTABLE POWER SOURCE
This generator is designed to provide up to its max power (in watts) of electrical power. When
using the generator as a portable power source, you can plug electric devices and appliances
directly into the generator’s electrical outlets. This generator is equipped with two SAA approved IP66
rated socket outlets.
Make sure you plug each electrical device/appliance into the correct generator outlet based on the
device’s plug configuration and voltage/amperage rating. Never exceed the amperage rating of an
outlet. Note: You must not overload the generator. Overloading may cause serious damage to the
generator and attached electrical devices.
SET UP AS A BUILDING BACKUP
For this application, you must arrange for a licensed electrician to connect the generator to your
buildings electrical system via the installation of an approved transfer switch. The transfer switch must
be installed in accordance with building electrical code and guidelines supplied by your power company.
A transfer switch does the following:
• Safely connects the generator to your building’s electrical system by isolating your generator from
your utility company’s power lines.
• Connects your generator to a critical subset of your building’s circuits that are needed for emergency
power needs.
A transfer switch must be installed in order to isolate your generator from the utility power grid. If
your generator is NOT properly isolated from the utility system, serious hazards will arise.
When your generator is running, it’s output will back feed into the utility power line and transformer
that are normally used to provide you with power. The transformer will step up the current to the
normal line voltage. An unsuspecting utility line worker working on what he thinks is a deactivated
line could be electrocuted.
If your generator is connected (running or not) when utility power is restored, your generator will be
destroyed. It could also explode or cause fire.
Regardless of whether you use your generator as a back-up power source connected to a building
or as a portable power source, you must not overload the generator. Overloading may cause serious
damage to the generator and attached electrical devices.
If your generator will be connected to your building’s electrical system, it MUST ALWAYS be
isolated from the utility power grid with a approved transfer switch installed by a licensed electrician
in compliance with all applicable building and electrical codes and in accordance with guidelines
supplied by your power company. continued over page
DANGER
! !
NOTICE
12 www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations,
local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified
electrician, electrical inspector, or the local agency having jurisdiction.
• In some areas, generators are required to be registered with local utility companies.
• If the generator is used at a construction site, there may be additional regulations that must be
observed.
NOTICE
GROUNDING THE GENERATOR
Standard generators are protected by electrical separators. This equipment has a thermic protection
device and/or a magne to thermic device to protect against a surge of current, overloading and short-
circuiting. In these cases the Generator should under no circumstances be earthed using the terminal
“PE” or with any other part of the generator.
If a licensed electrician installs the generator with a connection to your building’s electrical circuit for use
as a back-up power system, grounding may alternatively be completed through the building’s grounding
system. Ask your electrician.
If the generator is not grounded through your building’s electricial system, follow the procedure below.
This precedure can only be carried out by a licensed electrician.
In order to avoid electrical accidents, all connections to the distribution panel must be carried out by
qualified technicians. Incorrect connections can harm people and damage the generator.
Operating the generator when it’s not properly grounded can result in electrical shock.
Grounding is not required when the generator is used as a portable power source. Below grounding
method is only needed by a qualified electrician if not connecting through your building’s electrical
system.
WARNING
! !
WARNING
! !
1. Drive a 3/4" or 1" copper pipe or rod into the
ground close to the generator. The pipe/rod
must penetrate moist earth - the depth required
will be dictated by local soil conditions.
2. Connect an approved ground clamp to the pipe.
3. Run a 10 gauge wire from the clamp to the
generator grounding post located on the rear of
the generator head.
4. Do not connect the generator grounding post
to a water pipe or a ground used by a radio
system.
15OPERATING MANUAL
! WARNING
Grounding is not required when the generator is used as a portable power source.
Below grounding method is only needed by a qualied electrician if not connecting
through your building’s electrical system.
If the generator is not grounded through your building’s electricial system, follow the
procedure below. This precedure can only be carried out by a licensed electrician.
1. Drive a ¾” or 1” copper pipe or rod into
the ground close to the generator. The
pipe/rod must penetrate moist earth – the
depth required will be dictated by local soil
conditions.
2. Connect an approved ground clamp to the
pipe.
3. Run a 10 gauge wire from the clamp to the
generator grounding post located on the
rear of the generator head.
4. Do not connect the generator grounding
post to a water pipe or a ground used by a radio system.
IMPORTANT!
This generator is tted with a MEN link cable, the neutral is internally bonded to the generator
earth. When a licensed electrician is installing the generator to a building to be used as backup
power the MEN must be removed. The MEN link is located is underneath the alternator end cap
which is labeled to indicate its location. The MEN link cable clearly labeled as “MEN Link”.
EXTENSION CORDS
Extension cords may be used to power devices that are located at a distance from the
generator. However, use only Australian approved outdoor - rated, grounded extension cords.
Locate the generator in a convenient place and where possible avoid long extension leads and
possible damage to leads by pedestrian or vehicular trac.
Extension leads should be heavy duty with at least 1mm, of appropriate current rating and
in any case not less than 1mm cross-section of conductor and must incorporate an earthing
conductor to ensure that there is no voltage dierence between the generater set and any
equipment powered by the generater.
The electrical continuity of the ‘earthing’ core should be checked periodically from pin to socket
to ensure continued electrical safety. Some electrical appliances, e.g. portable drills, are marked
or ‘double insulated’, in which case there should not be an earthing conductor in
its mains lead (even though it may have a three-pin plug).
! WARNING
Use of under sized extension cords can cause electric shock, re, or damage to
connected devices. All extension and appliance cords must be in good condition
and not worn, bare, frayed, or otherwise damaged.
Use of damaged electric cords can cause electric shock or re. Note: If an extension
cord becomes hot to the touch, it is overloaded or damaged and must be replaced.
SABER is NOT responsible for damage or injury resulting from customer use of
inadequate extension cords.
SELECT A SUITABLE SITE
22 GENERATOR
CHARGING A BATTERY
! WARNING
It’s suggested to wear protective clothing, gloves and eye protection when handling
and working with lead acid batteries. For operators with pacemakers or similar
medical devices and conditions, it is recommended not to attempt the following
procedure.
DO NOT attempt to charge a lead acid battery in conned areas. Ensure the charging
process takes place in an area where there is fresh air circulating.
Remove the battery from the car, boat or any other device. The battery MUST be totally isolated
from any other circuitry. After connection to the battery, RECHECK to ensure the connections
are as below.
•Insert the T-shaped plug to the generator with the opposite end of the cable connected to
the battery.
•Connect the positive (+) alligator clip (red) to the positive (+) terminal on the battery.
•Connect the negative (-) alligator clip (black) to the negative (-) terminal on the battery.
•Start the generator and allow the generator to warm up.
•Check the DC reset button is pressed inward (ON position).
The battery charging process is now underway. To disconnect the battery on charge, STOP THE
ENGINE and remove the plug from the generator socket and disconnect the cable clamps from
the battery, in that order.
Note: The battery charging socket should only be used while the 240V AC outlets are NOT
being used. If the battery was originally in a low level of charge, the battery will take many
hours to recharge fully. The time frame will depend on the size of the battery.
! WARNING
DO NOT leave battery charging unattended. Charging battery for a long period of
time can damage the battery once the battery is full.
Over-charging or over-heating can damage the battery, the water and acid solution
can boil and leak out of the battery.
DC OVERLOAD CUT OUT
CAUTION Exceeding the rated capacity of your generator can result in serious damage to your
generator and connected apparatus.
•The DC circuit has a circuit breaker to protect the generator from over loading.
•If the circuit breaker trips, unplug all electrical apparatus from the generator.
•Let the overload cut out switch to cool down and remove the load from the DC circuit.
•Press the DC reset button.
•When re-connecting the DC load, reduce the load which previously overloaded the
generator.
Note: Some batteries, depending on the size, battery condition or level or charge may exceed
the max current output from the generator and trip the overload DC circuit breaker.
OPERATION
13
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
EXTENSION CORDS
Use of under sized extension cords can cause electric shock, fire, or damage to connected devices.
All extension and appliance cords must be in good condition and not worn, bare, frayed, or otherwise
damaged.
Use of damaged electric cords can cause electric shock or fire. Note: If an extension cord becomes
hot to the touch, it is overloaded or damaged and must be replaced. ITM is NOT responsible for
damage or injury resulting from customer use of inadequate extension cords.
WARNING
! !
This generator is fitted with a MEN link cable, the neutral is internally bonded to the generator earth.
When a licensed electrician is installing the generator to a building to be used as backup power
the MEN must be removed. The MEN link is located is underneath the alternator end cap which is
labeled to indicate its location. The MEN link cable clearly labeled as “MEN Link”.
Extension cords may be used to power devices that are located at a distance from the generator.
However, use only Australian approved outdoor - rated, grounded extension cords. Locate the generator
in a convenient place and where possible avoid long extension leads and possible damage to leads by
pedestrian or vehicular traffic.
Extension leads should be heavy duty with at least 1mm, of appropriate current rating and in any case
not less than 1mm cross-section of conductor and must incorporate an earthing conductor to ensure that
there is no voltage difference between the generator set and any equipment powered by the generator.
The electrical continuity of the ‘earthing’ core should be checked periodically from pin to socket to
ensure continued electrical safety. Some electrical appliances, e.g. portable drills, are marked or ‘double
insulated’, in which case there should not be an earthing conductor in its mains lead (even though it may
have a three-pin plug).
IMPORTANT
! !
OPERATION
14 www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
ENGINE SPEED
CONNECTING LOADS
240V AC CONNECTION
OPERATION
Engine speed has been factory set to provide safe operation. Tampering with the engine speed
adjustment could result in overheating of attachments and could cause a fire.
You will want to be careful when connecting loads so as not to overload the generator, especially if you
are powering devices with motors that require a higher starting power load.Instructions are provided
below for connecting loads when you are using the generator as a portable power source.
Connect electrical loads one at a time according to the following instructions:
1. Allow engine to reach operating speed by allowing it to warm up for approximately 5 minutes before
connecting electrical devices.
2. Check the devices to be connected is turned “OFF” before connecting them to the AC outlets.
3. After engine is warmed up, begin by connecting the items that require the highest wattage first.
The recommended sequence is as follows:
1. Connect items with motors such as refrigerators, freezers, air conditioners, or small hand tools, one
at a time.
2. Let each motor stabilize before connecting the next device.
3. Connect any lights you are planning on powering.
4. Connect voltage sensitive equipment such as electronics via surge protectors. Plug devices such
as TV’s, computers and microwaves into a voltage surge protector, then plug the surge protector
into the generator.
12V DC CONNECTION
The generator is fitted with a socket outlet specifically for connection to a lead acid battery for charging.
The output voltage is 12V with maximum output current of 8.3A. The generator will charge lead acid
batteries of various sizes from small to large.
DO NOT attempt to charge Nicad, Nickel Metal hybrid, or lithium type batteries. ONLY use provided
charger cable.
The generator must be run at the correct speed in order to produce the proper electrical voltage
and frequency. Failure to do so could result in damage to equipment powered by the generator and
possible injury to the individual.
Do not overload generator. Make sure that combined starting and running loads do not exceed rated
capacity of generator. Overloading the generator can cause damage to the generator and attached
electrical devices and may result in fire.
WARNING
! !
WARNING
! !
15
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
CHARGING A BATTERY
OPERATION
Remove the battery from the car, boat or any other device. The battery MUST be totally isolated from
any other circuitry. After connection to the battery, RECHECK to ensure the connections are as below.
• Insert the T-shaped plug to the generator with the opposite end of the cable connected to the battery.
• Connect the positive (+) alligator clip (red) to the positive (+) terminal on the battery.
• Connect the negative (-) alligator clip (black) to the negative (-) terminal on the battery.
• Start the generator and allow the generator to warm up.
• Check the DC reset button is pressed inward (ON position).
The battery charging process is now underway. To disconnect the battery on charge, STOP THE
ENGINE and remove the plug from the generator socket and disconnect the cable clamps from the
battery, in that order.
Note: The battery charging socket should only be used while the 240V AC outlets are NOT being used.
If the battery was originally in a low level of charge, the battery will take many hours to recharge fully.
The time frame will depend on the size of the battery.
It’s suggested to wear protective clothing, gloves and eye protection when handling and working with
lead acid batteries. For operators with pacemakers or similar medical devices and conditions, it is
recommended not to attempt the following procedure.
DO NOT attempt to charge a lead acid battery in confined areas. Ensure the charging process takes
place in an area where there is fresh air circulating.
WARNING
! !
DO NOT leave battery charging unattended. Charging battery for a long period of time can damage
the battery once the battery is full.
Over-charging or over-heating can damage the battery, the water and acid solution can boil and leak
out of the battery.
WARNING
! !
16 www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
OPERATION
NEVER exceed the rated wattage capacity of your generator. OVERLOADING may cause SERIOUS
DAMAGE to the generator and attached electrical devices and may result in fire.
WARNING
! !
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage
of the devices you will be powering. Before using your generator, determine the running and starting
wattage requirements of all the electrical devices you will be powering simultaneously. Following below 4
simple steps and example on the right:
Step 1. Determine the tools and appliances you want to power at the
same time
Step 2. List the start up and running power usage (Watts) for each
product
Step 3. Add the total power usage and add 10% as a safety net
Step 4. Choose a generator with a rated and maximum power that equals or exceeds your totals. In
this case a generator with a rated power of at least 3108W and a maximum power output greater than
7233W would be required.
STARTING POWER CONSUMPTION
Electronic appliances and brushed motors generally will not draw more than running Watts at start up.
Induction motors in equipment like air conditioners, welders, water pumps and compressors can draw
2 to 5 times their running power to start. Please consult your equipment’s rating label, manual or the
manufacturer to confirm specific requirement. If only the running wattage is given on the nameplate for
a device with an electric motor, the starting wattage can be approximated to be three to five times the
running wattage. Estimates for the running wattage requirements for common devices are listed in the
table below. Guidance for starting wattages is provided in the table’s footnotes. To size your generator
correctly you need to use Watts - here are some useful calculations:
Watts = Volts x Amps Example 240 Volts x 5 Amps = 1200 Watts
(a) Hard-starting motors require 3-5 times the rated running watts (b) For extremely hard to start loads such as air conditioners and
air compressors, consult the equipment dealer to determine max wattage.
DEVICE RUNNING
WATTS
DEVICE RUNNING
WATTS
DEVICE RUNNING
WATTS
Air conditioner (12.000
BTU)
1700 (a,b) Freezer 800 (b) Oven 4500
Battery charger (20 Amp) 500 Hair dryer 1200 Paint sprayer, Airless (1/3
HP)
600 (a)
Belt sander (3”) 1000 Hand drill (1”) 1100 Paint sprayer, Airless
(handheld)
150
Chain saw 1200 Hand drill (3/8”) 500 Radio 200
Circular saw(6½”) 2000 (a,b) Hedge trimmer 450 Refrigerator 600 (b)
Coffee maker 1800 (a,b) Home computer 150 Slow cooker 200
Compressor (1 HP) 1400 (a,b) Kettle 2400 Submersible pump (1-1/2 HP) 2800 (a)
Compressor (3/4 HP) 1800 (a) Jet pump 800 (a) Submersible pump (1 HP) 2000 (a)
Compressor (1/2 HP) 1400 (a) Lawn mower 1200 Submersible pump (1/2 HP) 1500 (a)
Curling iron 700 Light bulb (100 Watt) 100 Sump pump 600 (a)
Dishwasher 1200 Microwave oven 700 Television 500
Edge trimmer 500 Milk cooler 1100 (a) Toaster 1000
Electric nail gun 1200 Oil burner on furnace 300 Vacuum cleaner 250
Electric range (1 element) 1500 Oil-red space heater (140,000 Btu) 400 Water heater 3000
Electric skillet 1250 Oil-red space heater (85,000 Btu) 225
Furnace fan (1/3 HP) 1200 (a) Oil-red space heater (30,000 Btu) 150
17
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
STARTING THE ENGINE
OPERATION
PRE-OPERATION CHECK
1. Check that all shields and covers are in place, and all nuts, bolts, and screws are tightened.
2. Check the engine oil level. Add oil if low. Do not overfill. Running the engine without sufficient oil
can cause unrepairable damage.
3. Check fuel level. Add fuel if low (fresh unleaded RON 91 recommended). Starting with a full tank
will help to eliminate or reduce operating interruptions for refuelling. Check fuel system components
and lines for signs of leak.
4. Check battery level. If the battery level is unable to start the engine, charge it with the 12V charger
included in the package.
19OPERATING MANUAL
STARTING THE ENGINE
PRE-OPERATION CHECK
1. Check that all shields and covers are in place, and all nuts, bolts, and screws are tightened.
2. Check the engine oil level. Add oil if low. Do not overll. Running the engine without
sucient oil can cause unrepairable damage.
3. Check fuel level. Add fuel if low (fresh unleaded RON 91 recommended). Starting with a
full tank will help to eliminate or reduce operating interruptions for refuelling. Check fuel
system components and lines for signs of leak.
4. Check battery level. If the battery level is unable to start the engine, charge it with the 12V
charger included in the package.
RCBO SAFETY CHECK
1. Lift the clear plastic cover on the panel to access the RCBO safety toggle switch.
2. TEST THE RCBO before each and every use by pressing the test button. This will
immediately cause the unit to trip and shut o the power to the socket outlets. If the RCBO
fails to switch OFF after depressing the test button (marked “T”) then the unit should be
immediately taken out of service, tagged appropriately and not be used until repaired by a
qualied electrician.
3. RESET THE RCBO by simply switching the RCBO toggle to ON position.
4. The unit is now ready for operation. No electrical device should be operated or plugged in
prior to checking for physical damage and testing of the RCBO.
Fill oil to the
bottom lip of the
dipstick
18 GENERATOR
! WARNING
NEVER exceed the rated wattage capacity of your generator. OVERLOADING may
cause SERIOUS DAMAGE to the generator and attached electrical devices and may
result in re.
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage of the devices you will be powering.
Before using your generator, determine the running and starting wattage requirements of all the electrical devices you will be powering
simultaneously. Following below 4 simple steps and example on the right:
Step 1. Determine the tools and appliances you want to power at the same time
Step 2. List the start up and running power usage (Watts) for each product
Step 3. Add the total power usage and add 10% as a safety net
Step 4. Choose a generator with a rated and maximum power that equals or exceeds your totals
In this case a generator with a rated power of at least 3108W and a maximum power output
greater than 7233W would be required.
STARTING POWER CONSUMPTION
Electronic appliances and brushed motors generally will not draw more than running Watts
at start up. Induction motors in equipment like air conditioners, welders, water pumps and
compressors can draw 2 to 5 times their running power to start. Please consult your equipment’s rating label, manual or the manufacturer to
conrm specic requirement. If only the running wattage is given on the nameplate for a device with an electric motor, the starting wattage
can be approximated to be three to ve times the running wattage. Estimates for the running wattage requirements for common devices are
listed in the table below. Guidance for starting wattages is provided in the table’s footnotes.
To size your generator correctly you need to use Watts - here are some useful calculations: Watts = Volts x Amps Example 240 Volts x 5 Amps =
1200 Watts
DEVICE RUNNING WATTS DEVICE RUNNING WATTS
Air conditioner (12.000 BTU) 1700 (a,b) Jet pump 800 (a)
Battery charger (20 Amp) 500 Lawn mower 1200
Belt sander (3”) 1000 Light bulb (100 Watt) 100
Chain saw 1200 Microwave oven 700
Circular saw(6½”) 2000 (a,b) Milk cooler 1100 (a)
Coee maker 1800 (a,b) Oil burner on furnace 300
Compressor (1 HP) 1400 (a,b) Oil-red space heater (140,000 Btu) 400
Compressor (3/4 HP) 1800 (a) Oil-red space heater (85,000 Btu) 225
Compressor (1/2 HP) 1400 (a) Oil-red space heater (30,000 Btu) 150
Curling iron 700 Oven 4500
Dishwasher 1200 Paint sprayer, Airless (1/3 HP) 600 (a)
Edge trimmer 500 Paint sprayer, Airless (handheld) 150
Electric nail gun 1200 Radio 200
Electric range (1 element) 1500 Refrigerator 600 (b)
Electric skillet 1250 Slow cooker 200
Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/2 HP) 2800 (a)
Freezer 800 (b) Submersible pump (1 HP) 2000 (a)
Hair dryer 1200 Submersible pump (1/2 HP) 1500 (a)
Hand drill (1”) 1100 Sump pump 600 (a)
Hand drill (3/8”) 500 Television 500
Hedge trimmer 450 Toaster 1000
Home computer 150 Vacuum cleaner 250
Kettle 2400 Water heater 3000
(a) Hard-starting motors require 3-5 times the rated running watts (b) For extremely hard to start loads such as air conditioners and air
compressors, consult the equipment dealer to determine max wattage
19OPERATING MANUAL
STARTING THE ENGINE
PRE-OPERATION CHECK
1. Check that all shields and covers are in place, and all nuts, bolts, and screws are tightened.
2. Check the engine oil level. Add oil if low. Do not overll. Running the engine without
sucient oil can cause unrepairable damage.
3. Check fuel level. Add fuel if low (fresh unleaded RON 91 recommended). Starting with a
full tank will help to eliminate or reduce operating interruptions for refuelling. Check fuel
system components and lines for signs of leak.
4. Check battery level. If the battery level is unable to start the engine, charge it with the 12V
charger included in the package.
RCBO SAFETY CHECK
1. Lift the clear plastic cover on the panel to access the RCBO safety toggle switch.
2. TEST THE RCBO before each and every use by pressing the test button. This will
immediately cause the unit to trip and shut o the power to the socket outlets. If the RCBO
fails to switch OFF after depressing the test button (marked “T”) then the unit should be
immediately taken out of service, tagged appropriately and not be used until repaired by a
qualied electrician.
3. RESET THE RCBO by simply switching the RCBO toggle to ON position.
4. The unit is now ready for operation. No electrical device should be operated or plugged in
prior to checking for physical damage and testing of the RCBO.
Fill oil to the
bottom lip of the
dipstick
18 GENERATOR
! WARNING
NEVER exceed the rated wattage capacity of your generator. OVERLOADING may
cause SERIOUS DAMAGE to the generator and attached electrical devices and may
result in re.
Your generator MUST BE SIZED PROPERLY to provide both the running and starting (surge) wattage of the devices you will be powering.
Before using your generator, determine the running and starting wattage requirements of all the electrical devices you will be powering
simultaneously. Following below 4 simple steps and example on the right:
Step 1. Determine the tools and appliances you want to power at the same time
Step 2. List the start up and running power usage (Watts) for each product
Step 3. Add the total power usage and add 10% as a safety net
Step 4. Choose a generator with a rated and maximum power that equals or exceeds your totals
In this case a generator with a rated power of at least 3108W and a maximum power output
greater than 7233W would be required.
STARTING POWER CONSUMPTION
Electronic appliances and brushed motors generally will not draw more than running Watts
at start up. Induction motors in equipment like air conditioners, welders, water pumps and
compressors can draw 2 to 5 times their running power to start. Please consult your equipment’s rating label, manual or the manufacturer to
conrm specic requirement. If only the running wattage is given on the nameplate for a device with an electric motor, the starting wattage
can be approximated to be three to ve times the running wattage. Estimates for the running wattage requirements for common devices are
listed in the table below. Guidance for starting wattages is provided in the table’s footnotes.
To size your generator correctly you need to use Watts - here are some useful calculations: Watts = Volts x Amps Example 240 Volts x 5 Amps =
1200 Watts
DEVICE RUNNING WATTS DEVICE RUNNING WATTS
Air conditioner (12.000 BTU) 1700 (a,b) Jet pump 800 (a)
Battery charger (20 Amp) 500 Lawn mower 1200
Belt sander (3”) 1000 Light bulb (100 Watt) 100
Chain saw 1200 Microwave oven 700
Circular saw(6½”) 2000 (a,b) Milk cooler 1100 (a)
Coee maker 1800 (a,b) Oil burner on furnace 300
Compressor (1 HP) 1400 (a,b) Oil-red space heater (140,000 Btu) 400
Compressor (3/4 HP) 1800 (a) Oil-red space heater (85,000 Btu) 225
Compressor (1/2 HP) 1400 (a) Oil-red space heater (30,000 Btu) 150
Curling iron 700 Oven 4500
Dishwasher 1200 Paint sprayer, Airless (1/3 HP) 600 (a)
Edge trimmer 500 Paint sprayer, Airless (handheld) 150
Electric nail gun 1200 Radio 200
Electric range (1 element) 1500 Refrigerator 600 (b)
Electric skillet 1250 Slow cooker 200
Furnace fan (1/3 HP) 1200 (a) Submersible pump (1-1/2 HP) 2800 (a)
Freezer 800 (b) Submersible pump (1 HP) 2000 (a)
Hair dryer 1200 Submersible pump (1/2 HP) 1500 (a)
Hand drill (1”) 1100 Sump pump 600 (a)
Hand drill (3/8”) 500 Television 500
Hedge trimmer 450 Toaster 1000
Home computer 150 Vacuum cleaner 250
Kettle 2400 Water heater 3000
(a) Hard-starting motors require 3-5 times the rated running watts (b) For extremely hard to start loads such as air conditioners and air
compressors, consult the equipment dealer to determine max wattage
18 www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
ELECTRIC START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Verify the battery is properly installed and both
battery cables are attached (see Connecting the
Battery on page 11).
3. Make sure the circuit breakers are properly set (see
Figure 8).
Figure 8 - Breakers
1 240/120VMain Circuit Breaker Operating Position
2 240/120V Main Circuit Breaker Tripped Position
3 120V Circuit Breaker Operating Position
4 120V Circuit Breaker Tripped Position
4. Move the fuel shuto valve to the ON position (see
Figure 9).
ON
OFF
Figure 9 - Fuel Shut O - ON
5. Push the engine control switch into the RUN position
(see Figure 10).
Figure 10 - Engine Control Switch - RUN
6. Push and hold the push button start until the
generator starts, then release. If using remote start
then hold down START on the remote key fob until
the generator starts, then release (see Figure 11).
START
STOP
Figure 11 - Push Button Start/Remote Start
•The engine will automatically set the choke and
begin the start sequence.
•If the engine has started successfully the light
indicator on the engine start button will turn green.
•If the engine fails to start, the generator controls
will attempt to start the engine two more times for
a total of three attempts.
•If the third attempt fails, the light on the engine
start button will turn red.
•If the engine has failed to start after three attempts
the push button start can be pushed again to begin
the automatic start sequence.
•The engine control switch can be switched at any
time during the automatic start sequence to abort
the engine start attempt.
NOTE: If the cranking speed drops after each
unsuccessful attempt, then the battery may not
be adequately charged. You can alternatively start
the generator using the recoil start as instructed in
Manually Starting a Generator on page 21.
7. Plug in electric devices.
OPERATION
ELECTRIC START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Verify the battery is properly installed and both
battery cables are attached (see Connecting the
Battery on page 11).
3. Make sure the circuit breakers are properly set (see
Figure 8).
Figure 8 - Breakers
1 240/120VMain Circuit Breaker Operating Position
2 240/120V Main Circuit Breaker Tripped Position
3 120V Circuit Breaker Operating Position
4 120V Circuit Breaker Tripped Position
4. Move the fuel shuto valve to the ON position (see
Figure 9).
ON
OFF
Figure 9 - Fuel Shut O - ON
5. Push the engine control switch into the RUN position
(see Figure 10).
Figure 10 - Engine Control Switch - RUN
6. Push and hold the push button start until the
generator starts, then release. If using remote start
then hold down START on the remote key fob until
the generator starts, then release (see Figure 11).
START
STOP
Figure 11 - Push Button Start/Remote Start
•The engine will automatically set the choke and
begin the start sequence.
•If the engine has started successfully the light
indicator on the engine start button will turn green.
•If the engine fails to start, the generator controls
will attempt to start the engine two more times for
a total of three attempts.
•If the third attempt fails, the light on the engine
start button will turn red.
•If the engine has failed to start after three attempts
the push button start can be pushed again to begin
the automatic start sequence.
•The engine control switch can be switched at any
time during the automatic start sequence to abort
the engine start attempt.
NOTE: If the cranking speed drops after each
unsuccessful attempt, then the battery may not
be adequately charged. You can alternatively start
the generator using the recoil start as instructed in
Manually Starting a Generator on page 21.
7. Plug in electric devices.
OPERATION
ELECTRIC START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Verify the battery is properly installed and both
battery cables are attached (see Connecting the
Battery on page 11).
3. Make sure the circuit breakers are properly set (see
Figure 8).
Figure 8 - Breakers
1 240/120VMain Circuit Breaker Operating Position
2 240/120V Main Circuit Breaker Tripped Position
3 120V Circuit Breaker Operating Position
4 120V Circuit Breaker Tripped Position
4. Move the fuel shuto valve to the ON position (see
Figure 9).
ON
OFF
Figure 9 - Fuel Shut O - ON
5. Push the engine control switch into the RUN position
(see Figure 10).
Figure 10 - Engine Control Switch - RUN
6. Push and hold the push button start until the
generator starts, then release. If using remote start
then hold down START on the remote key fob until
the generator starts, then release (see Figure 11).
START
STOP
Figure 11 - Push Button Start/Remote Start
•The engine will automatically set the choke and
begin the start sequence.
•If the engine has started successfully the light
indicator on the engine start button will turn green.
•If the engine fails to start, the generator controls
will attempt to start the engine two more times for
a total of three attempts.
•If the third attempt fails, the light on the engine
start button will turn red.
•If the engine has failed to start after three attempts
the push button start can be pushed again to begin
the automatic start sequence.
•The engine control switch can be switched at any
time during the automatic start sequence to abort
the engine start attempt.
NOTE: If the cranking speed drops after each
unsuccessful attempt, then the battery may not
be adequately charged. You can alternatively start
the generator using the recoil start as instructed in
Manually Starting a Generator on page 21.
7. Plug in electric devices.
OPERATION
ELECTRIC START
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Verify the battery is properly installed and both
battery cables are attached (see Connecting the
Battery on page 11).
3. Make sure the circuit breakers are properly set (see
Figure 8).
Figure 8 - Breakers
1 240/120VMain Circuit Breaker Operating Position
2 240/120V Main Circuit Breaker Tripped Position
3 120V Circuit Breaker Operating Position
4 120V Circuit Breaker Tripped Position
4. Move the fuel shuto valve to the ON position (see
Figure 9).
ON
OFF
Figure 9 - Fuel Shut O - ON
5. Push the engine control switch into the RUN position
(see Figure 10).
Figure 10 - Engine Control Switch - RUN
6. Push and hold the push button start until the
generator starts, then release. If using remote start
then hold down START on the remote key fob until
the generator starts, then release (see Figure 11).
START
STOP
Figure 11 - Push Button Start/Remote Start
•The engine will automatically set the choke and
begin the start sequence.
•If the engine has started successfully the light
indicator on the engine start button will turn green.
•If the engine fails to start, the generator controls
will attempt to start the engine two more times for
a total of three attempts.
•If the third attempt fails, the light on the engine
start button will turn red.
•If the engine has failed to start after three attempts
the push button start can be pushed again to begin
the automatic start sequence.
•The engine control switch can be switched at any
time during the automatic start sequence to abort
the engine start attempt.
NOTE: If the cranking speed drops after each
unsuccessful attempt, then the battery may not
be adequately charged. You can alternatively start
the generator using the recoil start as instructed in
Manually Starting a Generator on page 21.
7. Plug in electric devices.
OPERATION
ELECTRIC START
Be sure to check oil levels before starting. If it is the
first time starting make sure to add oil.
1. Make sure nothing is plugged into power outlets
2. Verify the battery is properly installed and both
battery cables are attached.
3. Make sure the circuit breakers are properly set (see
Figure 8).
4. Move the fuel shutoff valve to the ON position (see
Figure 9).
5. Push the engine control switch into the RUN position
(see Figure 10).
6. Push and hold the push button start until
the generator starts, then release. If using
remote start then hold down START on the
remote key fob until the generator starts,
then release (see Figure 11).
7. Plug in electric devices.
• The engine will automatically set the choke
and begin the start sequence.
• If the engine has started successfully the
light indicator on the engine start button
will turn green.
• If the engine fails to start, the generator
controls will attempt to start the engine two
more times for a total of three attempts.
• If the third attempt fails, the light on the
engine start button will turn red.
• If the engine has failed to start after three
attempts the push button start can be
pushed again to begin the automatic start
sequence.
• The engine control switch can be switched
at any time during the automatic start
sequence to abort the engine start attempt.
1. 240/120VMain Circuit Breaker Operating Position
2. 240/120V Main Circuit Breaker Tripped Position
3. 120V Circuit Breaker Operating Position
4. 120V Circuit Breaker Tripped Position
If the cranking speed drops after each
unsuccessful attempt, then the battery
may not be adequately charged. You can
alternatively start the generator using
the recoil start as instructed in Manually
Starting The Generator on page 20.
NOTICE
OPERATION
19
www.itmtools.com.au

PETROL GENERATOR GC SERIES
OPERATOR’S MANUAL
MANUALLY STARTING THE GENERATOR
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set
(see Figure 8).
3. Move the fuel shut off valve to the ON position
(see Figure 9).
4. 5. Push the engine control switch into the RUN
position (see Figure 10).
5. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps
to stop your generator:
1. Remove any connected loads from the control
panel receptacles.
b. Warm Start: Open the choke by moving it
left towards the wheels of the generator.
6. Firmly grasp and pull the recoil handle slowly
until you feel increased resistance. At this
point, apply a rapid pull while pulling up and
slightly away from the generator (see Figure
12).
7. Plug in electric devices
If you plan to store the generator after use,
stop the generator by turning the fuel shutoff
valve to the OFF position and allow the fuel to
be consumed from the carburetor.
NOTICE
OPERATION
MANUALLY STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set (see
Figure 8).
4. Move the fuel shut o valve to the ON position (see
Figure 9).
5. Push the engine control switch into the RUN position
(see Figure 10).
6. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
Choke position for cold start.
b. Warm Start: Open the choke by moving it left
towards the wheels of the generator.
Choke position for warm start.
7. Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply a
rapid pull while pulling up and slightly away from the
generator (see Figure 12).
Figure 12 - Pull recoil
8. Plug in electric devices.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control panel
receptacles.
2. Allow the generator to run at “no load” to reduce and
stabilize engine and alternator temperatures.
3. Choose from options below to stop the generator
(see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until generator stops
• Hold the STOP button on the remote start key
fob (Note: The generator will run for an additional
15 seconds as it goes through a cool down cycle
before shutting o.)
START
STOP
Figure 13 - Stopping the generator
NOTE If you plan to store the generator after use,
stop the generator by turning the fuel shuto
valve to the OFF position and allow the fuel to be
consumed from the carburetor.
4. Turn the fuel shuto valve to the OFF position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, position the engine control switch to the
STOP position immediately.
OPERATION
MANUALLY STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set (see
Figure 8).
4. Move the fuel shut o valve to the ON position (see
Figure 9).
5. Push the engine control switch into the RUN position
(see Figure 10).
6. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
Choke position for cold start.
b. Warm Start: Open the choke by moving it left
towards the wheels of the generator.
Choke position for warm start.
7. Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply a
rapid pull while pulling up and slightly away from the
generator (see Figure 12).
Figure 12 - Pull recoil
8. Plug in electric devices.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control panel
receptacles.
2. Allow the generator to run at “no load” to reduce and
stabilize engine and alternator temperatures.
3. Choose from options below to stop the generator
(see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until generator stops
• Hold the STOP button on the remote start key
fob (Note: The generator will run for an additional
15 seconds as it goes through a cool down cycle
before shutting o.)
START
STOP
Figure 13 - Stopping the generator
NOTE If you plan to store the generator after use,
stop the generator by turning the fuel shuto
valve to the OFF position and allow the fuel to be
consumed from the carburetor.
4. Turn the fuel shuto valve to the OFF position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, position the engine control switch to the
STOP position immediately.
OPERATION
MANUALLY STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set (see
Figure 8).
4. Move the fuel shut o valve to the ON position (see
Figure 9).
5. Push the engine control switch into the RUN position
(see Figure 10).
6. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
Choke position for cold start.
b. Warm Start: Open the choke by moving it left
towards the wheels of the generator.
Choke position for warm start.
7. Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply a
rapid pull while pulling up and slightly away from the
generator (see Figure 12).
Figure 12 - Pull recoil
8. Plug in electric devices.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control panel
receptacles.
2. Allow the generator to run at “no load” to reduce and
stabilize engine and alternator temperatures.
3. Choose from options below to stop the generator
(see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until generator stops
• Hold the STOP button on the remote start key
fob (Note: The generator will run for an additional
15 seconds as it goes through a cool down cycle
before shutting o.)
START
STOP
Figure 13 - Stopping the generator
NOTE If you plan to store the generator after use,
stop the generator by turning the fuel shuto
valve to the OFF position and allow the fuel to be
consumed from the carburetor.
4. Turn the fuel shuto valve to the OFF position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, position the engine control switch to the
STOP position immediately.
OPERATION
MANUALLY STARTING THE GENERATOR
Be sure to check oil levels before starting. If it is the rst
time starting make sure to add oil (see Adding Engine Oil
page 24).
1. Make sure nothing is plugged into power outlets
2. Make sure the circuit breakers are properly set (see
Figure 8).
4. Move the fuel shut o valve to the ON position (see
Figure 9).
5. Push the engine control switch into the RUN position
(see Figure 10).
6. Manually set the choke:
a. Cold Start: Close the choke by moving it right
towards the front handle of the generator.
Choke position for cold start.
b. Warm Start: Open the choke by moving it left
towards the wheels of the generator.
Choke position for warm start.
7. Firmly grasp and pull the recoil handle slowly until
you feel increased resistance. At this point, apply a
rapid pull while pulling up and slightly away from the
generator (see Figure 12).
Figure 12 - Pull recoil
8. Plug in electric devices.
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to stop
your generator:
1. Remove any connected loads from the control panel
receptacles.
2. Allow the generator to run at “no load” to reduce and
stabilize engine and alternator temperatures.
3. Choose from options below to stop the generator
(see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until generator stops
• Hold the STOP button on the remote start key
fob (Note: The generator will run for an additional
15 seconds as it goes through a cool down cycle
before shutting o.)
START
STOP
Figure 13 - Stopping the generator
NOTE If you plan to store the generator after use,
stop the generator by turning the fuel shuto
valve to the OFF position and allow the fuel to be
consumed from the carburetor.
4. Turn the fuel shuto valve to the OFF position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, position the engine control switch to the
STOP position immediately.
OPERATION
2. Allow the generator to run at “no load” to
reduce and stabilize engine and alternator
temperatures.
3. Choose from options below to stop the
generator (see Figure 13):
• Position the engine control switch to STOP
• Hold push button start until generator stops
• Hold the STOP button on the remote start
key fob (Note: The generator will run for an
additional 15 seconds as it goes through a cool
down cycle before shutting off)
PROGRAMMING THE GENERATOR FOR
REMOTE START
The key fob included with the generator should
come already paired with the unit. If it does
not you can follow the directions below to
reconnect. If your unit was shipped without a
key fob please contact our customer support
team.
NOTICE
4. Turn the fuel shutoff valve to the OFF position.
During an Emergency
If there is an emergency and the generator must
be stopped quickly, position the engine control
switch to the STOP position immediately.
Always make sure the area around the
generator is clear of bystanders before using
the remote start to start the generator.
WARNING
! !
20 www.itmtools.com.au
This manual suits for next models
7