ITW Vortec 901 Series Use and care manual

OPERATION & SAFETY
INSTRUCTIONS
10125 Carver Road, Cincinnati, OH 45242
1IPOFt'BY
5PMM'SFF
XXXWPSUFDDPNtUFDITVQQPSU!WPSUFDDPN
Please read all instructions BEFORE
attempting to use this product
IMPORTANT
LIT0125
ROUND AIR FLOW AMPLIFIERS
.PEFMTTFSJFT"
*ODMVEFTBMM#41WFSTJPOTPGNPEFMTMJTUFEBCPWF
FILTER AND REPLACEMENT PART ITEM NUMBERS
Vortec Model 5 micron Air Filter Oil Removal Filter Pressure Regulator .002” or .003” shims
901 series 701S-24A 701S-48 208R 901-002, 901-003
909A 701S-24A 701S-48 208R -
902 701S-24A 701S-48 208R 902-002, 902-003
903 701S-36A 701S-48 208RX 903-002, 903-003
904 701S-40A 701S-54 208RX 904-002, 904-003
TABLE 1: FILTER RECOMMENDATIONS
TABLE 2: DETERMINING COMPRESSED AIR LINE SIZE
1. Calculate total product compressed air consumption (SCFM, SLPM).
2. Determine length of compressed air line required for connection to main supply.
3. Locate pipe length in left column and read to the right to nd the compressed air requirements.
4. Locate pipe size at top of column.
MAXIMUM AIRFLOW (SCFM) THROUGH PIPE AT 5 PSIG PRESSURE DROP (100 PSIG AND 70OF)
Pipe Length
(Feet)
Pipe Size (Nominal) - Schedule 40
1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2
10 29 65 120 254 480 978 1483 2863 4536
20 21 46 85 180 340 692 1049 2024 3208
30 17 37 70 147 277 565 856 1653 2619
40 15 32 60 127 240 489 792 1431 2268
50 13 29 54 114 215 437 663 1280 2029
60 12 26 49 104 196 399 606 1169 1852
70 11 25 46 96 181 370 561 1082 1715
80 10 23 43 90 170 346 524 1012 1604
90 10 22 40 85 160 326 494 954 1512
100 9 21 38 80 152 309 469 905 1435
MAXIMUM AIRFLOW (SLPM) THROUGH PIPE AT 0.3 BAR PRESSURE DROP (6.9 BAR AND 21OC)
Pipe Length
(Meters)
Pipe Size (Nominal) - Schedule 40
1/4 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2
3 821 1840 3396 7188 13584 27677 42117 81023 128369
6 594 1302 2406 5094 9622 19584 29687 57279 90786
9 481 1047 1981 4160 7839 15990 24225 46780 74188
12 425 906 1698 3594 6792 13839 20999 40497 64184
15 368 821 1528 3226 6085 12367 18763 36224 57421
18 340 736 1387 2943 5547 11292 17150 33083 52412
21 311 708 1302 2717 5122 10471 15877 30621 48535
24 283 651 1217 2547 4811 9792 14829 28640 45393
27 269 623 1132 2406 4528 9226 13980 26998 42790
31 255 594 1075 2264 4302 8745 13273 25612 40611
Rubber hose maximum airow rating: 1/2” I.D. rubber hose = 3/8” pipe; 3/4” I.D. rubber hose = 1/2” pipe

INTRODUCTION
An air ow amplier uses a small amount of compressed
air to move a much larger air volume. Amplication ratios
may meet or exceed 20:1. For more details on airow of a
specic unit, visit www.vortec.com, or contact your local
distributor or Vortec.
COMPRESSED AIR SUPPLY
The compressed air supply must be ltered to remove
water and dirt using a 5 micron or smaller lter. Failure
to use a lter may cause clogging of the compressed air
paths inside the Vortec product. Filter recommendations
are given in Table 1.
Filter elements must be changed on a regular basis.
Frequency of change is determined by the condition of
the compressed air supply. Filters should be installed in
the compressed air supply line as close as possible to
the Vortec product.
The appropriate size of the compressed air supply line
should be selected to ensure optimal performance of the
Vortec product. Please refer to Table 2 to determine what
supply line size is recommended for your application.
Contact Vortec at 1-800-441-7475 for further assistance.
OPERATION
In order to vary the volume of airow from the air ow
amplier, an appropriately sized pressure regulator
can be used to control the compressed air pressure,
(less pressure = less airow). (Pressure regulator
recommendations are given in Table 1.)
The output airow volume can also be adjusted by varying
the internal air gap. For models with shims (901A, 901BA,
901DA, 901HA, 902, 903, 904), this is accomplished
by adding or removing gap shims (see Table 1). In
adjustable model 909A, this can be accomplished by
rotating the outlet barrel (counter-clockwise will increase
airow, clockwise will decrease airow).
INSTALLATION AND MAINTENANCE
Air ow ampliers can be installed by directly plumbing
to the appropriately-sized, hard piped, compressed air
source that does not exceed 150 psig (10.3 Bar), see
Table 2.
When using air ow ampliers for ducting fumes or
smoke, the duct must be sized, and routed to prevent
back pressure totaling more than 2” of water column.
Back pressure in ducted airow will substantially affect
performance.
It is critical to the performance of the air ow amplier
that the internal air passages remain clean. If the air
ow amplier’s performance suddenly drops, carefully
disassemble the unit and inspect for debris. If debris is
found, it may be necessary to change your lter element.
Clean the debris from the unit and reassemble. Use
caution during reassembly to ensure that the shim (where
applicable) remains centered and does not become
lodged in the air passage. For detailed instructions
on cleaning or reassembly, contact your authorized
distributor or Vortec.
TROUBLESHOOTING
Insufficient airow may be caused by the following:
1. Undersized compressed air line size.
2. Compressed air pressure too low.
3. Partial or complete blockage of internal air path,
due to dirt. See Maintenance section for cleaning
instructions; and Compressed Air Supply section for
lter recommendations.
4. Insufficient compressed air volume.
If trouble persists, please contact Vortec at 1-800-441-
7475.
1. Do not operate air ow ampliers at compressed
air pressures above 150 psig (10.3 Bar).
2. Do not operate airow ampliers at line
temperatures above 110oF (43oC).
3. Avoid direct contact with compressed air.
4. Do not direct compressed air at any person.
5. When using compressed air, wear safety glasses
with side shields.
GENERAL SAFETY CONSIDERATIONS
WARNING: COMPRESSED AIR COULD
CAUSE DEATH, BLINDNESS OR INJURY
EXPLODED VIEW - 902, 903, 904
(Drawings shown below are not to scale)
LIMITED WARRANTY
Vortec compressed air products manufactured by ITW
Air Management will be replaced or repaired if found to
be defective due to manufacture defect within ten years
from the date of invoice. Refer to our website www.vortec.
com for full warranty details and limitations. ITW Air
Management makes no specic warranty merchantability
or warrant of tness to a particular purpose.
FLOW
FLOW
FLOW
This manual suits for next models
4