IXIA XG12 User manual

XG12 Chassis Assembly Guide
Version 1.0
Release 8.20 EA,
December 2016

Copyright and Disclaimer
Copyright © 2016 Ixia. All rights reserved.
This publication may not be copied, in whole or in part, without Ixia's consent.
Ixia, the Ixia logo, and all Ixia brand names and product names in this document are
either trademarks or registered trademarks of Ixia in the United States and/or other coun-
tries. All other trademarks belong to their respective owners.
The information herein is furnished for informational use only, is subject to change by Ixia
without notice, and should not be construed as a commitment by Ixia. Ixia assumes no
responsibility or liability for any errors or inaccuracies contained in this publication.
RESTRICTED RIGHTS NOTICE
As prescribed by FAR 27.409(b)(4) and in accordance with FAR 52.227-14, please take
notice of the following.
(a) This proprietary computer software and/or software technical data is submitted with
restricted rights. It may not be used, reproduced, or disclosed by the Government
except as provided in paragraph (b) of this notice or as otherwise expressly stated in
the applicable contract.
(b) This computer software and/or software technical data may be—
(1) Used or copied for use with the computer(s) for which it was acquired, including
use at any Government installation to which the computer(s) may be transferred;
(2) Used or copied for use with a backup computer if any computer for which it was
acquired is inoperative;
(3) Reproduced for safekeeping (archives) or backup purposes;
(4) Modified, adapted, or combined with other computer software, provided that the
modified, adapted, or combined portions of the derivative software incorporating
any of the delivered, restricted computer software shall be subject to the same
restricted rights;
(5) Disclosed to and reproduced for use by support service Contractors or their sub-
contractors in accordance with paragraphs (b)(1) through (4) of this notice; and
(6) Used or copied for use with a replacement computer.
(c) Notwithstanding the foregoing, if this computer software and/or software technical
data is copyrighted computer software and/or software technical data, it is licensed to
the Government with the minimum rights set forth in paragraph (b) of this notice.
(d) Any other rights or limitations regarding the use, duplication, or disclosure of this
computer software and/or software technical data are to be expressly stated in, or
incorporated in, the applicable contract.
(e) This notice shall be marked on any reproduction of this computer software, in whole
or in part.
(End of notice)
ii XG12 Chassis Assembly Guide, Release 8.20 EA

Contacting Ixia
Contacting Ixia
Corporate
Headquarters
Ixia Worldwide Headquarters
26601 W. Agoura Rd.
Calabasas, CA 91302
USA
+1 877 FOR IXIA (877 367 4942)
+1 818 871 1800 (International)
(FAX) +1 818 871 1805
sales@ixiacom.com
Web site: www.ixiacom.com
General: info@ixiacom.com
Investor Relations: ir@ixiacom.com
Training: training@ixiacom.com
Support: support@ixiacom.com
+1 818 595 2599
EMEA Ixia Europe Limited
Part 2nd floor,
Clarion House, Norreys Drive
Maidenhead, UK SL6 4FL
+44 (1628) 408750
FAX +44 (1628) 639916
salesemea@ixiacom.com
Support: support-emea@ixiacom.com
+40 21 301 5699
Asia Pacific Ixia Pte Ltd
210 Middle Road
#08-01 IOI Plaza
Singapore 188994
Support: support-asiapac@ixi-
acom.com
+91 80 4939 6410
Japan Ixia KK
Nishi-Shinjuku Mitsui Bldg 11F
6-24-1, Nishi-Shinjuku, Shinjuku-ku
Tokyo 160-0023
Japan
Support: support-japan@ixiacom.com
+81 3 5326 1980
India Ixia Technologies Pvt Ltd
Tower 1, 7th Floor, UMIYA Business Bay
Cessna Business Park
Survey No. 10/1A, 10/2, 11 & 13/2
Outer Ring Road, Varthur Hobli
Kadubeesanahalli Village
Bangalore East Taluk
Bangalore-560 037, Karnataka, India
+91 80 42862600
Support: support-india@ixiacom.com
+91 80 4939 6410
China Ixia Technologies (Shanghai) Company Ltd
Unit 3, 11th Floor, Raffles City, Beijing
Beijing, 100007 P.R.C.
Support: support-china@ixiacom.com
400 898 0598 (Greater China Region)
+86 10 5732 3932 (Hong Kong)
C h a n g e : 4150211, D a t e : S e p t e m b e r 2 4 , 2 0 1 3
XG12 Chassis Assembly Guide, Release 8.20 EA iii

[This page intentionally left blank]

XG12 Chassis Assembly Guide, Release 8.20 EA v
Contents
Contents
Contacting Ixia iii
Introduction 1
XG12 Chassis Modules 3
Install XG12 Chassis 5
XG12 Chassis Installation Precautions 5
Un-pack and Mount the Chassis 6
Remove and Insert Processor Module 7
Remove and Insert Power Supply Module 8
Power Cords 10
Remove and Insert Fan Module 11
Log on to XG12 Chassis 13

[This page intentionally left blank]

Introduction
This document describes how to install the XG12 chassis and its various modules.
The XG12 Chassis is the next generation high performance platform capable of supporting
all XM form factor load modules, including full chassis configurations of the Xcellon-Flex
load modules. It is a 12-slot chassis with increased total power capacity available for all
load modules and front-to-back airflow delivery along with increased bandwidth from the
CPU to the load modules.
The chassis provides improved modularity and access to the major components to reduce
downtime of a failed chassis and to reduce the probability of needing to remove a failed
chassis from the test environment.
Figure: XG12 Chassis
XG12 Chassis Assembly Guide, Release 8.20 EA 1

[This page intentionally left blank]

XG12 Chassis Modules
The modules that make up the chassis are as follows:
lChassis Frame Module
lChassis Fan Module
lChassis Power Supply Module
lChassis Processor Module
The Processor Module is plugged into the front of the chassis. The power supplies and fans
are accessible from the rear of the chassis. Each of the modular components is capable of
being removed in the field and replaced with minimum downtime.
Figure: XG12 Chassis Back View
XG12 Chassis Assembly Guide, Release 8.20 EA 3

[This page intentionally left blank]

Install XG12 Chassis
The following sections describe the installation procedure:
lUn-pack and Mount the Chassis
lRemove and Insert Processor Module
lRemove and Insert Power Supply Module
lRemove and Insert Fan Module
XG12 Chassis Installation Precautions
The following precautions should be followed while installing the XG12 chassis:
lThe chassis should be installed in the rack before installing the power supply module,
fan module and load modules, thereby reducing the weight of the chassis.
lThe two lower bolts used to secure the chassis to a rack can be used to hold the
chassis frame in place while securing all of the other bolts.
lSecure the chassis to rack face with all six bolts.
lFully depress power supply clamps when installing power supply module.
lSecure the power supply module thumb bolt when installing power supply module.
lInstall the rear power supply cover before applying AC power. After removing or
installing this cover, ensure that the thumbscrews are tightened down with a 'Flat
Blade' screwdriver.
lDo not use the chassis without installing the Fan module.
lDo not use the chassis without installing the Processor module.
lDo not leave unused slots open. Use the filler panels to cover the un-used slots.
lDo not block the front air intake.
lA minimum air flow clearance of 12 inches is required. 24 inches of air flow clearance
is preferred at the rear of the chassis.
lOperator intervention may be required to power cycle the XG12 chassis or restart a
software program in the event the XG12 chassis operation is upset or stopped by elec-
trostatic discharge.
XG12 Chassis Assembly Guide, Release 8.20 EA 5

Install XG12 Chassis
Figure: XG12 Safety Features
Un-pack and Mount the Chassis
1. Cut tape and open the carton.
2. Remove accessories box, top foam inserts, and side packing inserts.
3. Lift chassis out of the carton.
4. Remove power supply cover and keep it aside.
5. Remove the plastic wrapping.
6. Insert the lowermost screws on the rack.
7. Slide the chassis into the rack so that the lower screw notches of the chassis rests on
the screws on the rack.
8. Insert the other screws and secure the chassis to the rack by tightening the screws.
6 XG12 Chassis Assembly Guide, Release 8.20 EA

Install XG12 Chassis
Figure: XG12 Mounted on Rack
The weight of the chassis components are as follows:
lEmpty chassis with air baffles = 70 lbs
lEmpty chassis without air baffles = 48 lbs
l3 power cords = 6 lbs
lPower supply assembly = 29 lbs
lFan Assembly = 10 lbs
lCPU card = 4 lbs
Do not attempt to lift the fully assembled chassis.
Remove and Insert Processor Module
To remove the processor module:
1. Unfasten the screws.
2. Pinch the clips and then pull outwards.
XG12 Chassis Assembly Guide, Release 8.20 EA 7

Install XG12 Chassis
Figure: XG12 Chassis removing processor module
To insert the processor module:
1. Slide the module into the slot.
2. Pinch on the clips and push them in.
3. Fasten the screws.
Figure: XG12 Chassis inserting processor module
Remove and Insert Power Supply Module
The power supply module is accessible after removing the rear cover. For details see Fig-
ure: XG12 Chassis Back View.
To remove the rear cover, unfasten the four screws around the cover and pull out the
cover.
To remove the power supply module:
8 XG12 Chassis Assembly Guide, Release 8.20 EA

Install XG12 Chassis
1. Loosen the thumbscrew in the upper left corner of the power supply module.
2. Pull the power clamp handles.
3. Hold the two handles provided on the power supply module and pull them.
To remove the individual power supplies,
1. Hold the handle on the power supply
2. Pull the clip inwards and then pull the handle out.
Figure: XG12 Individual Power Supply
To insert the individual power supplies, slide the power supply in until you hear the clicking
sound of the clip.
To insert the power supply module:
1. Place the power supply module on the rails.
Figure: XG12 Chassis inserting power supply module
2. Push the power supply module inwards.
XG12 Chassis Assembly Guide, Release 8.20 EA 9

Install XG12 Chassis
Figure:XG12 Chassis pushing power supply module
3. Push the power clamp handles in to lock the busbars in place.
Figure: XG12 Chassis pushing power clamp handles
4. To hold the power module in place, tighten the thumbscrew at the upper left corner of
the power supply module.
Figure: XG12 Chassis tightening thumbscrew
5. Replace the rear cover and fasten it with the screws.
Power Cords
The XG12 chassis is CE marked and UL™ certified when using the 200-240VAC power cords
supplied with the chassis. However, these certifications for the chassis safety approvals
are only valid when the unit is operating from all three 200-240VAC main power sources.
10 XG12 Chassis Assembly Guide, Release 8.20 EA

Install XG12 Chassis
Refer to the Ixia Platform Reference Manual at https://support.ixiacom.com/support-
overview/product-support/product-compatibility-matrix for more details.
Remove and Insert Fan Module
The fan module is located on the rear side of the chassis. For details see Figure : XG12
Chassis Back View.
To remove the fan module:
1. Unfasten the four screws that are present on the edges of the fan module.
2. Pull the module outwards.
Figure: XG12 Chassis removing fan module
To install the fan module:
1. Push the rubber grommets over the metal standoff on the chassis.
2. Fasten the four screws tightly.
XG12 Chassis Assembly Guide, Release 8.20 EA 11

[This page intentionally left blank]

Log on to XG12 Chassis
The Username for an XG12 (Windows 7) remote desktop session is ixia and the password
is the CPU module serial number found on the sticker located in front of the CPU module.
The two network ports on the CPU module are configured by default for DHCP.
The chassis windows wallpaper is not displayed. So the credentials are required
to log on.
XG12 Chassis Assembly Guide, Release 8.20 EA 13
Table of contents
Other IXIA Chassis manuals
Popular Chassis manuals by other brands

Cisco
Cisco TelePresence Server 7010 Replacement instructions

Supermicro
Supermicro SC813MF2 Series user manual

Supermicro
Supermicro SC825MTQ-R700LPB user manual

Advantech
Advantech ACP-4340 user manual

ADLINK Technology
ADLINK Technology cPCIS-6418U Series user manual

Netstor
Netstor NR340A-IP2 Quick installation guide

Cross Technologies
Cross Technologies 2001-21 instruction manual

National Instruments
National Instruments PXI EXPRESS PXIe-1095 CALIBRATION PROCEDURE

Advantech
Advantech PCE-5B06-00A1E Startup manual

VESTEL
VESTEL 11AK19 Service manual

National Instruments
National Instruments PXI-1042Q user manual

Supero
Supero SC742 user guide