J.E. Adams 9420-1G-DIG User manual

J.E. ADAMS INDUSTRIES
OWNERS MANUAL
MODEL 9420-1G-DIG – Digital Air / Vacuum
oPAGE 2 SPECIFICATIONS
oPAGE 2 IMPORTANT SAFETY INFORMATION
oPAGE 3-4 INSTALLATION
oPAGE 4–8 PROGRAMMING
oPAGE 8 OPERATING
oPAGE 9 MAINTENANCE
oPAGE 9-10 TROUBLESHOOTING
oPAGE 11 PARTS LIST
oPAGE 12 WIRE DIAGRAMS

SPECIFICATIONS:
Unit specifications:
Voltage: 110v, 60Hz
Amperage: (1) 20 amp service is required for this unit
Weight: 240 lbs with pallet attached
Vac specifications:
Motors: (2) 110v motors
Fuses: (2) 10 amp inline fuses
Compressor specifications:
Motor: (1) 3/4HP Twin Cylinder, 110V, 60HZ
NOTE: “UNIT INTENDED FOR COMMERCIAL USE ONLY”
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed,
including the following:
READ ALL INSTRUCTIONS BEFORE USING (THIS
APPLIANCE).
WARNING – To reduce the risk of fire, electric shock, or
injury:
Do not use vacuum on wet surfaces.
Use only as described in manual. Use only manufactures recommended
attachments.
Do not allow to be used as a toy. Close attention is necessary when used by
or near children.
Do not put any object into openings. Do not use with any opening blocked;
keep free of dust, lint, hair and anything that may reduce air flow.
Keep hair, loose clothing, fingers, and all parts of body away from openings
and moving parts.
Do not use to pick up flammable or combustible liquids, such as gasoline, or
use in areas where they may be present.
“Do not pick up anything that is burning or smoking, such as cigarettes,
matches, or hot ashes.”
“Do not use vacuum without dust bag and/or filters in place.”
Never use air compressor on tires containing sealers such as “FIX-A-FLAT”
type products!
3/30/2011 2

SAVE THESE INSTRUCTIONS
Installation Instructions:
Determine location to mount unit (“DANGER” “THIS EQUIPMENT
INCORPORATES PARTS SUCH AS SWITCHES, MOTORS, OR THE
LIKE THAT TEND TO PRODUCE ARCS OR SPARKS THAT CAN
CAUSE AN EXPLOSION. WHEN LOCATED IN GASOLINE-
DISPENSING AND SERVICE STATIONS INSTALL AND USE AT
LEAST 20 FEET (6 M) HORIZONTALLY FROM THE EXTERIOR
ENCLOSURE OF ANY DISPENSING PUMP AND AT LEAST 18
INCHES (450 MM) ABOVE A DRIVEWAY OR GROUND LEVEL.”
Run 20 amp service to specified location. Grounding Instructions: This
appliance must be connected to a grounded metal, permanent wiring
system; or an equipment-grounding conductor must be run with the
circuit conductors and connected to the equipment-grounding terminal or
lead on the appliance.
Unit must be mounted level for proper operation.
Mount unit to location and use fig. 1 for mount pattern
If unit is vault ready configuration see fig. 1 for mounting and fig. 2 for
vault tube location.
3/30/2011 3

Once unit has been installed use 5871B8 cap plugs supplied with unit to
seal holes in canister bottom located in lower cleanout door. Then connect
to power.
Turn unit on and move to programming instructions.
Programming Instructions:
Coin acceptor:
Comes standard with manual Imonex coin mech. no programming
needed.
Bill acceptor:
Bill acceptor comes pre programmed from J.E. Adams and should not
require any changes. If additional programming is needed to acceptors
please refer to additional literature sent along with this unit.
3/30/2011 4

Changing Settings: Quick Programming Method
Digital control panel/timer unit:
Unit may be programmed when received depending on information given
at that the time of order.
To program, follow the instructions below:
1. Turn unit off.
2. Hold coin switch lever in the down position.
3. Turn unit on.
4. Units display “t4” after s short boot up sequence.
5. Release coin mechanism switch lever.
6. As soon as coin mech switch lever is released, "No PU" will appear
(number of pulses) for a short time and then will automatically scroll to the
input quantity. The unit now displays a two digit number. This is the
minimum number of coins to make the unit engage for the programmed
time. “00” unit is free air, 01 for 1 coin, 02 for two coins, etc. Adjust by
using + or – buttons on the control panel. Note: vacuum and air
compressor are not able to be priced or timed at separate values.
The programmed price gives you the programmed time
regardless of function chosen.
7. Press i button to continue: Unit now advances to "Dur" (duration or
amount of time per coin) on the display and will automatically scroll to the
amount of time in seconds per coin. Adjust this amount by using + or –
buttons. Example: For 4 minutes of vend time for $ 0.75 – using the plus
or minus button set the duration to 80. This means 80 second per coin
(Quarter) for a total of 240 seconds or 4 minutes running time. (note: this
parameter will not show up if the unit is set to free vend, “00”, in the
previous step).
8. Press i button to continue and unit will display "COnn" (compressor) for a
short time and then automatically scroll to the compressor operation
mode. Choose which mode you would like by using the +/- buttons; "no" =
none or no compressor, "denn" = on demand, and "cont" = continuous.
"Cont" is recommended as it seems to cause the least amount of
confusion to the end user.
9. Press i button to continue and unit will now display "nnod" which is a
setting for a modem (Y or N). Most applications will not have a modem so
this will need to be set to "N" (no).
10. Press i button to continue and unit now displays "End".
Turn unit off for 10 seconds and the back on. Now controller has the new
parameters.
Counter:
To access the counter:
In normal operation mode, press "i" button and just after the beep press the
"minus" button (you must be quick - may have to do this 2-3 times).
3/30/2011 5

This unit has two counters:
The first one is a non-resetable 8 digit number shown in two steps: CnH 0000
and the CnL 0000.
When pay air mode the counter shows the number of coins put through the
machine (not the number of vends).
When free air mode the counter shows the number of vends.
Changing settings – advanced programming.
Before beginning, most domestic applications will require “PSI” rather than
"BARS" at the gauge and on the display. These settings are factory set at
JE Adams. Only access these settings if absoltuely necessary and write
down settings before you change them.
1. Turn power switch to off.
Hold coin switch lever in the down position.
2. Turn power switch to on, and wait for first audible “beep.”
Just after first “beep” press (“+”) button followed by
the (“-” ) button. “Prtr” is shown on the display.
(if Prtr is not displayed, turn unit off and try again)
3. Release the coin switch lever and
press “ i ” button once, “T-4” blinks on display and
will then disappear.
4. “1 Un” is now shown on the display for a brief moment
and will automatically scroll to the setting.
At this step, set the pressure unit for the gauge.
"PSI" or "BAR" are the options. Choose PSI for most
applications by using the + or - buttons on the control panel.
Press “i” button to continue
5. “2 Un” is now shown on the display for a brief moment
and will automatically scroll to the setting. "PSI" should
be shown, if not change to PSI.
Press “i” button to continue
3/30/2011 6

6. “dE” is now shown on the display for a brief moment.
At this step, set the default tire pressure, value which
is factory set at 32 PSI. Use + or - buttons to set.
Press “i” button to continue.
7. “LS” is now shown on the display. This is typically
set to 70 PSI which is the maximum pressure value.
Press “i” button to continue.
8. “nº PU” is shown on the display for a short moment and
then a two digit vaule is displayed. This represents the
number of coins to activate machine.
9. 00 is for free vend, 01 for one coin, 02 for two coins,
and so on. Choose by using + or - buttons.
Press “i” button to continue
Note: vacuum and air compressor are not able to be priced or
timed at separate values. The programmed price gives you the
programmed time regardless of function chosen.
10. “Dur” is now shown on the display which represents
the amount of time per coin in seconds. If
machine is set to “00” free vend, this option
will not be present. Set time per coin by using “–“ or “+” buttons.
Press “i” button to continue
11. “Conn” is now shown for a brief moment and then the
setting. Leave this at "cont". See quick programming
section of manual for full explanation.
Press “i” button to continue
12. “nnod” is shown on the display which is for the modem setting.
3/30/2011 7

Most machines will not have a modem so choose "no."
Press “i” button to continue
13. “End” is shown on the display
This indicates the setup is finished.
Turn tire gauge off, wait 10 seconds minimum before turning on.
Next time the tire gauge is on, it will work with the new settings
Operating Instructions:
Flip toggle switch to desired function, then insert coins or bills to start
machine.*
If other function is selected other than original selected item, unit will
switch to that function.
Once service is used, hang up hoses.
*NOTE: vacuum and air compressor are not able to be priced or
timed at separate values. The programmed price gives you the
programmed time regardless of function chosen.
Maintenance:
Filter bags should be taken out weekly and shaken out. Also it might be a
good idea to keep a new set of bags on hand so that once a month or
longer you can take original bags out and wash them.
Check vac hose and air hose for cracks on a weekly basis.
Clean canister with a stainless steel cleaner as needed.
Every month, remove filter from compressor and clean.
Check vac motor brushes approx. every 3 months for excessive wear.
Motor brushes should be changed if they are shorter than 3/8”.
Disconnect power before doing this!!
No lubrication required on vacuum motors or air compressor.
All servicing of machine should be conducted by an authorized service
representative.
3/30/2011 8

Troubleshooting:
DISCONNECT POWER BEFORE SERVICING!!
Problem Possible cause Solution
Unit is not powered. Fuse panel breaker may not be on. Turn on breaker.
Switch inside unit is not in the on
p
osition. Turn switch on.
Unit keeps blowing my
breaker from my
incoming power source
Inadequate wire size ran to machine Call electrician and install proper
wire size for required service
versus length or run.
Wrong size breaker, or non
dedicated line. Install correct breaker or
eliminate other components
from line.
Fuses for vac motors
keep blowing. Inadequate wire size ran to machine Call electrician and install proper
wire size for required service
versus length or run.
Motor brushes may be bad or too
short
(
under 3
/
8"
)
.Replace motor brushes
3/30/2011 9

Vacuum seems to
have lost suction Vac hose clogged Cleanout debris from vac hose
Filter ba
g
s need cleaned Clean filter ba
g
s or re
p
lace
Vac hose is s
p
lit/cracked. Re
p
lace vac hos
e
Cleanout door gaskets torn or
worn Replace gaskets
Plug(s) in bottom of can may have
came out. Replace with NEW plugs -
used plugs do not work well.
One motor may not be working. Confirm all motors are
working, replace if necessary.
Inadequate or no
pressure. System leaking Check air hose system for
leaks visually or by turning
machine off and applying air
chuck to tire or air tank with
at least 35lbs of pressure.
Listen for leaks.
Com
p
ressor not runnin
g
?Checkfuse/
p
ower.
Chuck washer is worn out Replace rubber washer inside
chuck with special JE Adams
PN 8533-13CW
3/30/2011 10

3/30/2011 11

3/30/2011 12
Table of contents
Other J.E. Adams Vacuum Cleaner manuals