manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. JABSCO
  6. •
  7. Water Heater
  8. •
  9. JABSCO 12573-3000 User manual

JABSCO 12573-3000 User manual

Popular Water Heater manuals by other brands

clage German pool CEX13 operating instructions

clage

clage German pool CEX13 operating instructions

Noritz proTough NR98SV installation manual

Noritz

Noritz proTough NR98SV installation manual

DeDietrich KALIKO TWH 200 EV Installation and service manual

DeDietrich

DeDietrich KALIKO TWH 200 EV Installation and service manual

veito FLOW Installation and operating instructions

veito

veito FLOW Installation and operating instructions

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

ICI Caldaie

ICI Caldaie COSMOGAS AGUATANK 150 Instructions for installation, use and maintenance manual

Savio Laser 11 A Instruction manual for installation and use

Savio

Savio Laser 11 A Instruction manual for installation and use

Kenmore 153.582400 Use & care guide

Kenmore

Kenmore 153.582400 Use & care guide

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

STIEBEL ELTRON

STIEBEL ELTRON Eltronom SHU 5 S Operating and installation instructions

clage E-Mini Series Operating and installation instructions

clage

clage E-Mini Series Operating and installation instructions

Solar SunX 317365-002 instruction manual

Solar

Solar SunX 317365-002 instruction manual

Bradford White EF Series Service manual

Bradford White

Bradford White EF Series Service manual

Dimplex ECSd125-580 Installation and user instructions

Dimplex

Dimplex ECSd125-580 Installation and user instructions

Dux 32FCR6N installation manual

Dux

Dux 32FCR6N installation manual

Noritz N-132M Owner's guide and installation manual

Noritz

Noritz N-132M Owner's guide and installation manual

TESY GCV7/4S 10047 Instructions for use and maintenance

TESY

TESY GCV7/4S 10047 Instructions for use and maintenance

A.O. Smith Gphe 50 instruction manual

A.O. Smith

A.O. Smith Gphe 50 instruction manual

Rinnai REP199i Installation and operation manual

Rinnai

Rinnai REP199i Installation and operation manual

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

Toyotomi

Toyotomi Oil Miser OM-148 (Type D) Operation and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1 Litre Accumulator Tank
12573-3000
• Improves all multiple outlet pressure controlled water systems
• Gives smoother flow, quieter water systems
• Provides better control of hot water temperature
• Results in longer pump life, lower battery drain
• Simply fitted to new or existing systems
• Light and compact
• Supplied complete with ‘T’ fitting for 13mm (½’’) ID hose
The Jabsco Accumulator Tank is intended for
installation in any water system supplied by a pressure
switch controlled water pump, for example Jabsco
pressure pumps, as found on boats, caravans, motor
homes, coaches, and recreational vehicles.
The accumulator tank smoothes water flow and
reduces on/off cycling of the pump by reducing the
variation in pressure and flow between the pump and
outlets in the system.
The even flow of water gives better control of hot water
temperature especially noticeable with instantaneous
gas water heaters and showers.
The reduced on/off cycling reduces noise from the
pump motor, and from shock pressures (water
hammer). It also reduces battery drain, and gives
longer pump life.
Specifications
• Impact and pressure resistant plastic construction
• FDA listed materials
• Maximum working pressure 125psi (8.5 bar)
• 1.2 Litre (0.3 Gallons) capacity
• Weight: 0.7 kg (1½lbs)
• Dimensions:
35cm (13¾’’) x 13cm (5¼’’) x 10 cm (4’’)
Improve your Water System
Features
Installation Instructions
1. MOUNTING - The Jabsco Accumulator Tank must
be mounted vertically.
2. LOCATION - The tank must be fitted in the outlet
line from the pump. Do not connect the accumulator
tank directly to the pump outlet port. Use flexible hose,
not rigid pipework, to isolate the accumulator tank from
any pump vibrations.
3. WATERTIGHT CONNECTIONS - PTFE tape must
be used when connecting either the ‘T’ fitting provided
or any other fitting to the ½’’ BSP externally threaded
outlet on the accumulator tank. Hose clips must be
used when connecting the hoses to the ‘T’ fitting.
4. DRAINING FACILITY - It is advisable to fit a drain
cock or plug in the lowest point of the water system to
make it easier to drain the water out of the
accumulator tank when the air cushion inside it has
been absorbed into the water.
1 Litre Accumulator Tank
To replace the air cushion:
1. Turn off the power to the water pump.
2. Open the tap farthest from the accumulator tank.
3. Remove the plug in the top of the accumulator tank.
4. Open the drain cock, if fitted, or loosen the pipe
joint on the pump delivery side, to drain the water
system.
NOTICE
• Hand tighten only. Do not overtighten top plug or ‘T’
fitting as this will damage the tank.
• Plastic or similar fittings only are recommended.
• Do not paint the accumulator tank as this may lead
to deterioration of the plastic material.
Warranty: All products of the company are sold and all services of the company are offered subject to the company’s warranty and terms and conditions of sale, copies of which will be furnished upon request.
The information provided herein is for guidance only, it does not constitute a guarantee of the performance or specification of any individual product or component.
©Copyright 2000 ITT Industries Discover Jabsco at www.jabsco.com 43001-0513 Rev: 03/03
Jabsco
ITT Industries
Jabsco, 20 Icon, Foothill Ranch, CA 92610
Tel : + 1 949 609 5106 Fax : +1 949 859 1254
Jabsco, Bingley Road, Hoddesdon, Hertfordshire, EN11 0BU
Tel : +44 (0) 1992 450 145 Fax : +44 (0) 1992 467 132
Fluid Products Canada,55 Royal Road, Guelph, Ontario N1H 1T1
Tel : +1 519 821 1900 Fax : +1 519 821 5316
NHK Jabsco Co Ltd,3-21-10, Shin - Yokohama, Kohoku-ku, Yokohama 222
Tel : +81 (0) 45 475 8906 Fax : +81 (0) 45 475 8908
Jabsco GmbH,Oststraße 28, 22844 Norderstedt
Tel : +49 (0) 40 53 53 73 0 Fax : +49 (0) 40 53 53 73 11
USA
UK
CANADA
JAPAN
GERMANY
Do not overpressurise the tank. Pressures
over 125psi (8.5 bar) may rupture tank and
cause personal injury.
Maintenance
Over time, the air cushion will be absorbed. This is
apparent when the pump starts to cycle rapidly if only
a small amount of water is used, for example by a
leaking tap, or when an instantaneous gas heater is
being operated on maximum heat setting.
5. Replace plug and washer in top of the accumulator
tank.
6. Close the drain cock, if fitted, or re-connect the
pipe joint, and leaving the tap furthest from the tank
open, switch on the pump. When water is flowing
smoothly, close the tap. The system should then
shut off automatically.
Dimensional Drawing