manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Jade Bird
  6. •
  7. Fire Alarm
  8. •
  9. Jade Bird JBE-2100 User manual

Jade Bird JBE-2100 User manual

Popular Fire Alarm manuals by other brands

Simplex 4010ES Quick reference guide

Simplex

Simplex 4010ES Quick reference guide

Global Fire Equipment VALKYRIE AS manual

Global Fire Equipment

Global Fire Equipment VALKYRIE AS manual

Zeta Alarm Systems INFINITY ID2 installation manual

Zeta Alarm Systems

Zeta Alarm Systems INFINITY ID2 installation manual

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

System Sensor

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

Pittway Notifier AM2020 troubleshooting guide

Pittway

Pittway Notifier AM2020 troubleshooting guide

Ampac ZoneSense user manual

Ampac

Ampac ZoneSense user manual

Kidde VM-1 Technical reference manual

Kidde

Kidde VM-1 Technical reference manual

LST SIM016-3 Specification sheet

LST

LST SIM016-3 Specification sheet

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

Fireboy- Xintex

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

GST DI-9204 Installation

GST

GST DI-9204 Installation

Fire-Lite Alarms MS-2 instructions

Fire-Lite Alarms

Fire-Lite Alarms MS-2 instructions

hyfire HY5000 Series install guide

hyfire

hyfire HY5000 Series install guide

Radionics Radionics 9124 user guide

Radionics

Radionics Radionics 9124 user guide

UniPOS FD 7120 instruction manual

UniPOS

UniPOS FD 7120 instruction manual

Teletek electronics SensoMAG MRB50 installation instructions

Teletek electronics

Teletek electronics SensoMAG MRB50 installation instructions

bolid S2000-IP-03 instruction manual

bolid

bolid S2000-IP-03 instruction manual

FIREGUARD GLOBAL FG-S01_AP quick start guide

FIREGUARD GLOBAL

FIREGUARD GLOBAL FG-S01_AP quick start guide

Panasonic MEW01091 operating instructions

Panasonic

Panasonic MEW01091 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

M-2100-1: JBE-2100 Manual Call Point data sheet V1.0
Jade Bird Fire Alarm Systems – JadeBird.eu.com 1 / 4 JBE-2100.DSH.EN.210128
Overview
JBE-2100 is an addressable manual call point (MCP) designed to operate on
a loop of intelligent fire detection and alarm devices with the JBE loop
protocol. This MCP sends fire alarm signals to the fire panel when the
resettable element is pressed as defined in the European norm EN 54-11.
After activation, the MCP will remain in alarm until it is reset with the
supplied reset key. There is no glass break element in this device, so the reset
operation is done without the need to replace any element.
The JBE-2100 also features a pair of normally open clean contacts, which
close at activation. These can be optionally used for a local action or to
provide an activation signal to third party systems.
M-2100-1: JBE-2100 Manual Call Point data sheet V1.0
Jade Bird Fire Alarm Systems – JadeBird.eu.com 2 / 4 JBE-2100.DSH.EN.210128
Technical data
Category
EN 54-11 type A indoor MCP
Working voltage
DC 19 - 28V (JBE protocol pulse amplitude)
Connection
2-wire JBE communication bus, no polarity
Wire size
Twisted pair, max. wiring gauge 2.5 mm2
Quiescent current
≤0.3 mA @24 V
Alarm current
≤1.0 mA @24 V
Clean contact rating
0.1 A @30 V DC
Working temp.
-10℃ ~ +55℃
Storage temp.
-20℃ ~ +60℃
Environment
≤ 95% RH (40±2℃) (no condensation nor icing)
Addressing method
Soft addressing with tool JBE-AT1, non-volatile
Address range
1-200
Red LED Indication
Standby: Flashing when polled
Alarm: Steady on when in alarm
Dimensions
90×90×52 mm (LxWxH)
Weight
0.16 kg
IP rating
IP40
Compatible base
JBE-2170
M-2100-1: JBE-2100 Manual Call Point data sheet V1.0
Jade Bird Fire Alarm Systems – JadeBird.eu.com 3 / 4 JBE-2100.DSH.EN.210128
Installation
Always observe local fire and electric installation regulations.
1. Secure the base to the wall (surface or flush mounted).
2. Connect the wiring to the base as per the following diagram:
Terminals
Connection
1 & 2
Signal loop L1, L2 (no
polarity)
7 & 8
(Optional) Normally open
clean contact switch
Max rating: 0.1 A, 30 V
3,4,5,6
Not connected
3. Program an unused loop address (1 to 200) to the MCP head using the
JBE-AT1 tool.
4. Insert the MCP face into its base and push firmly.
5. The head can be secured to the base by fitting an optional self-tapping
screw (ST2.9x8) into its boss next to the reset keyhole.
6. Register the MCP into the fire panel’s configuration.
7. Test each MCP and wiring integrity after installation and periodically
according to local fire regulation.
Maintenance
Alarm test should be conducted regularly, recommending every 6 months.
Resetting an activated MCP
1. Open the tab in the bottom of the MCP face.
2. Insert the reset key.
3. Rotate key counterclockwise until the frangible element returns to its
position.
M-2100-1: JBE-2100 Manual Call Point data sheet V1.0
Jade Bird Fire Alarm Systems – JadeBird.eu.com 4 / 4 JBE-2100.DSH.EN.210128
Mechanical dimensions
all dimensions in mm
Regulatory information
0370
Jade Bird Fire Alarm International (Europe), S.L.
C. Tarragona, 157. 08014 Barcelona (Spain)
20
DoP-0370-CPR-3803-1
EN 54-11
JBE-2100
Manual call point (type A indoor MCP), intended for use in fire detection
and fire alarm systems installed in and around buildings.
Technical file: see TF-JBE-2100-10 provided by the manufacturer.
Jade Bird Fire Alarm International (Europe), S.L.
C. Tarragona, 157. 08014 Barcelona (Spain)
www.jadebird.eu.com