  9. Global Fire Equipment VALKYRIE AS User manual

Global Fire Equipment VALKYRIE AS User manual

This manual suits for next models

1

Other Global Fire Equipment Fire Alarm manuals

Global Fire Equipment ZEOS-C User manual

Global Fire Equipment

Global Fire Equipment ZEOS-C User manual

Global Fire Equipment ZEOS-AD-S User manual

Global Fire Equipment

Global Fire Equipment ZEOS-AD-S User manual

Global Fire Equipment ORION EX MINI-REP User manual

Global Fire Equipment

Global Fire Equipment ORION EX MINI-REP User manual

Global Fire Equipment JUNIOR V3 Manual

Global Fire Equipment

Global Fire Equipment JUNIOR V3 Manual

Global Fire Equipment MPX-SNDR-DG - 4 V2 User manual

Global Fire Equipment

Global Fire Equipment MPX-SNDR-DG - 4 V2 User manual

Global Fire Equipment ORION Instruction manual

Global Fire Equipment

Global Fire Equipment ORION Instruction manual

Global Fire Equipment ZEOS C User manual

Global Fire Equipment

Global Fire Equipment ZEOS C User manual

Popular Fire Alarm manuals by other brands

Simplex 4010ES Quick reference guide

Simplex

Simplex 4010ES Quick reference guide

Zeta Alarm Systems INFINITY ID2 installation manual

Zeta Alarm Systems

Zeta Alarm Systems INFINITY ID2 installation manual

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

System Sensor

System Sensor 22051TLE-RF-26 Installation and maintenance instructions

Pittway Notifier AM2020 troubleshooting guide

Pittway

Pittway Notifier AM2020 troubleshooting guide

Ampac ZoneSense user manual

Ampac

Ampac ZoneSense user manual

Kidde VM-1 Technical reference manual

Kidde

Kidde VM-1 Technical reference manual

LST SIM016-3 Specification sheet

LST

LST SIM016-3 Specification sheet

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

Fireboy- Xintex

Fireboy- Xintex FBD-MZ Owner's Manual & Installation Instructions

GST DI-9204 Installation

GST

GST DI-9204 Installation

Fire-Lite Alarms MS-2 instructions

Fire-Lite Alarms

Fire-Lite Alarms MS-2 instructions

hyfire HY5000 Series install guide

hyfire

hyfire HY5000 Series install guide

Radionics Radionics 9124 user guide

Radionics

Radionics Radionics 9124 user guide

UniPOS FD 7120 instruction manual

UniPOS

UniPOS FD 7120 instruction manual

Teletek electronics SensoMAG MRB50 installation instructions

Teletek electronics

Teletek electronics SensoMAG MRB50 installation instructions

bolid S2000-IP-03 instruction manual

bolid

bolid S2000-IP-03 instruction manual

FIREGUARD GLOBAL FG-S01_AP quick start guide

FIREGUARD GLOBAL

FIREGUARD GLOBAL FG-S01_AP quick start guide

Panasonic MEW01091 operating instructions

Panasonic

Panasonic MEW01091 operating instructions

Notifier UZC-256 installation manual

Notifier

Notifier UZC-256 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

1
Valkyrie A
Addressable Wall Sounder - Beacon
Instruction Manual V2.0- 12/2010
High Quality
Complies with EN-54 pt.3
Low current consumption
4.1 mA for combined Sounder/Beacon
110 dB maximum sounder output at 1 m
Synchronization for fast activation
Compatible with all GFE addressable panels
Features
The VALKYRIE A is a wall mounted
addressable sounder with low power
consumption available in either Red
or White housings. Up to 32
individually addressed sounders can
be installed per loop occupying an
address in the range 94 to 125. The
address is set using switches 1 to 5
of the 8 way DIL switch.
Four different tones are available
and selected using DIL switches 6
and 7.
When individual address reporting is
not required, VALKYRIE A can be
configured as a Shadow sounder. In
this case sounders do not occupy an
address in the loop thus freeing up
addresses for more detection
devices.
Shadow sounders do not report back
to the control panel so their
presence on the loop is not
monitored. Shadow sounders draw
current from the loop (maximum 7.5
mA in alarm for sounder/ beacon
version @ High frequency settings)
and must be included in loop load
calculations.
Enclosure - Material
Protection Category
Weight
Dimensions
Max. Humidity
Operating Temperature
Max. Cable Size
Loop Current - Quiescent
Loop Current -Alarm Low. Freq.
Loop Current -Alarm High. Freq.
Loop Current -Alarm Beacon
Sounder Output - Low Freq.
Sounder Output - Continuous
Sounder Output - High Freq.
Technical Specifications
Supply Voltage
4.1 mA (Max.) - 2.6 mA (Min.)
7.5 mA (Max.) - 3 mA (Min.)
1.4 mA
103 dB @ 1 m (Max.) - 98 dB @ 1 m (Min.)
102 dB @ 1 m (Max.) - 97 dB @ 1 m (Min.)
110 dB @ 1 m (Max.) - 100 dB @ 1 m (Min.)
2
2.5 mm
Red/ White ABS
IP44
254 g - including mounting base
110.0 mm (Dia) x 85.1 mm (H)
0 ºC to 40 ºC
95% RH Non-Condensing
17V to 30 V DC
0.5 mA
VALKYRIE ASB-RED
VALKYRIE ASB-WHITE
GFE-ISO-BASE
GFE-ISO-BASE-RED
Order Code
VALKYRIE AS-RED
VALKYRIE AS-WHITE
Valkyrie Addressable Wall Sounder-Red
Valkyrie Addressable Wall Sounder-White
Valkyrie Addressable Wall Sounder/Beacon-Red
Valkyrie Addressable Wall Sounder/Beacon-White
Detector Base with Loop Isolator
Detector Base with Loop Isolator-Red
Weight
Sounder/ Beacon - 254 g*
Including packaging - 304 g
*including mounting base
Enclosure Construction Material
White or Red ABS
85.1
100.5
All dimensions in mm
110.0
Mechanical Specification
D.I.L. Switch Configurations
1 ON = 1
2 ON = 2
3 ON = 4
4 ON = 8
5 ON = 16
Switches 1-5
Used to configure Address in the range
94-125
Switch 6 and 7
Tone Selection
Switch 8
Shadow Sounder
1 2 345678
OFF (0)
ON (1)
Tone Selection
ALTERNATING
HIGH-FREQUENCY TONE
2.7 KHz - 3.2 KHz
1 2 345678
OFF (0)
ON (1)
CONTINUOUS
TONE
800 Hz
1 2 345678
OFF (0)
ON (1)
SWEEPING
TONE
800-1000 Hz
1 2 345678
OFF (0)
ON (1)
ALTERNATING
LOW-FREQUENCY TONE
800-1000 Hz
1 2 345678
OFF (0)
ON (1)
Global Fire Equipment S.A.
MARF - Armazens F3 e F4, Sítio do Guelhim, Estoi, 8009-021 FARO, PORTUGAL
Tel: + 351 289 896 560 Fax: + 351 289 865 587
Sales [email protected] Technical Support [email protected]
1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8
1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8
1234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8 1 234 5 6 7 8
102
110
118
103
111
119
104
112
120
105
113
121
106
114
122
107
115
123
108
116
124
1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8 1234 5 6 7 8
94 95 96 97 98 99 100 101
109
117
125
Sounder 1 Sounder 2 Sounder 3 Sounder 4 Sounder 5 Sounder 6 Sounder 7 Sounder 8
Sounder 9 Sounder 10 Sounder 11 Sounder 12 Sounder 13 Sounder 14 Sounder 15 Sounder 16
Sounder 17 Sounder 18 Sounder 19 Sounder 20 Sounder 21 Sounder 22 Sounder 23 Sounder 24
Sounder 25 Sounder 26 Sounder 27 Sounder 28 Sounder 29 Sounder 30 Sounder 31 Sounder 32
Sounder/ Beacon Address Settings
Sounder Type
Switch No. 8
OFF = Shadow
ON = Normal
4
1
SOUNDER BASE - LOOP CONNECTIONS
LOOP
OUT
LOOP
RETURN
PANEL
To next device
in loop or return
to panel
Note: Address programmed on switches 1-5 has an OFFSET of 94. For example
if D.I.L. switches 1-5 are all set to OFF the actual sounder address, as read by
the panel, will be 94.
Address Switches
Binary Weights
To lock sounder remove
pin available at terminal
4 on the underside of the
sounder using a small
screwdriver.
To unlock sounder from
its base push provided
unlock key through hole
available on the base
side wall as shown.
Sounder Base Lock