Jauch JES1500WHA User manual

USER MANUAL
Jauch Power Station JES1500WHA
ENGLISH – GERMAN

Thank you for purchasing this Jauch Power Station. Please read all instructions and cautions
carefully before use to avoid personal injury or damage to the Power Bank and any connected
products.
OBERSERVE ALL INPUTS AND OUTPUTS
To avoid fire or electrical shock hazard, observe all ratings on unit, and products you intend to use;
check manual for more information.
USE IN AN VENTILATED AREA
Ensure proper ventilation while in use and do not obstruct fan openings on unit. Inadequate
ventilation may cause damage to the power bank. Do not stack anything on top of the power bank
in storage or in use.
DO NOT OPERATE IN WET CONDITIONS
In order to avoid short circuits or electric shocks do not allow unit to get wet.
Any manipulation to the unit or its components will void all warranties.
A
Power Button Power Bank
B
Power Button DC Output
C
Power Button AC Bank
D
LED Indicator Light
E
USB Output (5V)
F
USB-C Output
G
Display Screen
H
Input
I
Cigarette Lighter Output (12V)
IMPORTANT SAFETY INSTRUCTIONS
GET TO KNOW YOUR JAUCH POWER STATION

1
Jauch Power Bank JES1500WHA
2
Power Supply
3
Solar Charge Cable (7909 to MC4)
4
Jauch Manual
Power Button Power Bank
Power On: Hold the power button for approximately 2 seconds
to turn on the power station. The corresponding indicator light
will turn on and the display will light up
Power Off: Hold the power button for approximately 2 seconds
to turn off the power station.
Power Button DC Output
Turn On DC Output: Hold the DC button for approximately 2
seconds to turn on DC output. The corresponding indicator light
will turn on “DC ON” will be displayed on the display.
Turn Off DC Output: Hold the DC button for approximately 2
seconds to turn off DC output. The corresponding indictor light
will turn off and “DC OFF” will be displayed on the display.
Power Button AC Output
Turn On AC Output: Hold the AC button for approximately 2
seconds to turn on AC output. The corresponding indicator light
will turn on and “AC ON” will be displayed on the display.
Turn Off AC Output: Hold the AC button for approximately 2
seconds to turn off AC output. The corresponding indicator light
will turn off and “AC OFF” will be displayed on the display.
Note
: When the power station is turned off, the AC Output will
be disabled. When the power station is turned on, AC output is
turned off by default. Please hold the power button to turn on
WHAT YOU GET
EXPLANATION OF THE POWER BUTTONS AND LCD DISPLAY

the power station and then hold the AC power button to turn on
the output.
LCD Display
The built-in LCD display indicates three important values:
Inputs
Shows the amount of power (Watts) going into the power station while
charging.
Outputs DC/ AC
Shows the amount of power (Watts) and output your devices will be using
while plugged into the Jauch power station.
Battery Level
Shows 5 segments 20%, 40%, 60%, 80%, 100% capacity. As you use your
power station, segments will disappear from the display, indicating the
remaining charge. When charging the power station, you will notice a battery
segment blinking. This indicates the current charge status. One your power
station is fully charged; all battery segments will be lit and remain solid.
Note: The failure code (see page 9) will appear at on the right side of the screen where you
originally can see the Input, DC and AC power.

There are three ways to charge this Jauch Power Station.
CHARGING WITH SOLAR PANEL
1. Place the solar panel somewhere where it can receive direct sunlight.
2. Make sure that the open-circuit voltage of the solar panels falls within 16-60V. The maximum
input power of this power station is 600W (Max.)
3. Turn off the power station and connect the solar panel with the DC Input (DC 16-60V/10A). The
screen will light up after the power station is turned on and shows the input power wattage.
4. If you want to use the AC or DC outputs while charging the power station through the solar
panel, please press the AC or DC power button for more than one second.
CHARGING WITH CAR CHARGER
Insert one end of the car charger to the car cigarette lighter receptacle and insert the other end to
the input port of the power station. The battery icon will blink to indicate that the power station is
being charged.
CHARGE WITH AC ADAPTER
To charge this power station with the attached AC adapter insert one end of the adapter into a wall
outlet and insert the other end to the input port of the power station.
CHARGING YOUR JAUCH POWER STATION

When the power bank is charging, you can monitor the battery status by checking the battery icon
on the display.
This power station comes with a built-in advanced control circuit. When the battery is fully charged,
it will stop charging automatically.
THROUGH USB OUTPUT
1. Select the adapter that corresponds with your mobile devices and use it to connect the USB
power cable to the input port of your device:
2. Plug the other end of the USB cable into one of the USB outputs of the power station.
3. Once connected, the power bank will start to power your mobile devices automatically.
THROUGH DC OUTPUT
1. Connect the DC power cable to the input port of your device.
2. Plug the remaining end of the DC cable into the power station´s DC output port.
3. Once connected, the power station will automatically begin powering the device.
THROUGH USB TYPE C OUTPUT
1. Use the original USB Type-C cable for your device or the one included with the product
accessories.
2. Insert the USB-C cable into the USB-C output port of the power bank and connect the power
station with the device that needs to be charged.
3. The power station will automatically detect the load output and start powering the device.
THROUGH AC OUTPUT
1. Connect the power cable to the input port of your device.
2. Plug the remaining end of the AC cable into the power station´s AC output port.
3. Once connected, the power station will automatically begin powering the device.
Note: When the power station is turned off, the AC Output will be disabled. When the power station
is turned on, AC output is turned off by default. Please hold the power button to turn on the power
station and then hold the AC power button to turn on the output.
USING YOUR JAUCH POWER STATION

Please fully-charge your Jauch Power Station before storage and charge it every 3 months. Keep the
power station away from water, flammable gas, corrosive material, metals, dust and salt.
Failure to maintain your Jauch Power Station by following these steps can result in battery damage
which will void the product warranty.
STORAGE AND MAINTENANCE

Battery Energy
1500Wh
Output Specifications
AC Output
Rated Output Power
1000W
Rated Output Voltage
110Vac (US Version) / 230Vac (EU and UK Version)
Rated Frequency
50/60Hz
Power Factor
1
THDV@0.7R Load
<5%
Overload Capacity
1000W<load<1500W@2min
1500W<load@1s
No-Load Power Consumption
<8W
Max. Efficiency (>70% Load Power)
88% (US Version) / 90% (EU and UK Version)
DC 12V
Output
Output Voltage Range
12.2V (±1V)
Rated Output Current
9A (±1V)
USB1
Output
Output Voltage Range
5V±0.3V
Max. Output Current
3A
Remark: USB1 and USB2 are one group
Max. Output is 3A for one USB Output; Max. Output for
USB1 and USB2 is 3A
USB-C
Output
Quick Charge Supported
PD protocol (Max output: 45W)
Output Voltage Range
5~20V (5V by default)
Rated Output Current (under constant
voltage test)
5V/ 9V/ 12V/ 15V 3A (±0.3A)
20V/ 2.25A (±0.2A)
Overload Current
2.3-3A
Input Specifications
AC Input
42V/ 160-200W
PV Max. Input Power
14~40Vdc
PV Input Voltage Range
16-60Vdc
PV Max. Input Current
10A
MPPT
99.5%
MPPT Efficiency
>88%
Max. Efficiency
99.5%
Battery Specifications
Rated Voltage
14.8Vdc
Rated Energy
1500Wh
Cell Type
Li-Ion
Working Temperature
0°C-40°C/ 32°F-104°F
General Information
IP Rating
IP21
Dimensions
371x165x364 mm/ 14.5x6.5x14.5 in
Net Weight
17.2 kg/ 38 LBS
TECHNICAL SPECIFICATIONS

The following guide provides information on how to identify and correct troubleshoot reactions.
E01
Battery over-voltage protection
Only discharge possible; no charging
E02
Battery low-voltage protection
Charge the power station and restart it after fully
charged.
E03
Battery failure
Charge the power station and restart it after fully
charged.
E04
Battery discharge over-temperature protection
The unit is too hot. Cool down the power station
before charging the power station.
E05
Battery discharge low-voltage protection
The temperature of the battery is too low. Restore
the battery by increasing its temperature.
E06
Battery charge over-temperature protection
The unit is too hot. Cool down the power station
before charging the power station.
E07
Battery charge low-temperature protection
The temperature of the battery is too low. Restore
the battery by increasing its temperature.
E08
1
st
Group battery low-voltage protection
Charge the power station and restart it after fully
charged.
E09
2nd Group battery low-voltage protection
Charge the power station and restart it after fully
charged.
E10
3
rd
Group battery low-voltage protection
Charge the power station and restart it after fully
charged.
E11
4
th
Group battery low-voltage protection
Charge the power station and restart it after fully
charged.
E12
Inverter bus cable voltage failure
Please restart the power station.
E13
Inverter over-load protection
Please reduce the load and restart the power
station.
E14
Inverter short-circuit
Correct the short-circuit output and restart the AC
Output.
E15
Inverter cooling fin discharge over-temperature
protection
Cool down the power station.
E16
Inverter cooling fin temperature detector is fall off
Connect the NTC and restart the power station.
E17
PV Input over-voltage protection
Please check if you have used the PV input solar
panel in a proper way. If so, disconnect the PV,
restart the power station and connect the PV again.
E18
PV output over-voltage protection
Please check if you have used the PV input solar
panel in a proper way. If so, disconnect the PV,
restart the power station and connect the PV again.
E19
PV cooling fin charge over temperature protection
over-temperature protection
Recharge after the temperature of the cooling fin is
lower.
E20
PV cooling fin temperature detector felt off
Please contact our Customer Service.
E21
Battery protection board charge protection
Recharge after the temperature of the protection
board is lower.
E22
Battery false detection
Disconnect the PV and restart the power station.
E23
Generator over-load (AC&DC) protection
Reduce the total load and restart.
If you are still experiencing trouble with your Jauch Power Bank, please call our Customer Service
at +(1) 360 633 7200 or (+49) 07720 945 0 or by email at contact@jauchpowerondemand.com.
TROUBLE SHOOTING GUIDE

Lithium-ion battery: As soon as the Power Station has reached the end of its lifetime,
the entire lithium-ion battery can be recycled.
According to the European Directive 2006/66/EC, which has been transposed into
national law in the respective EU member states, batteries are not allowed to be
disposed of with household waste. Consumers are obliged to take batteries to a
suitable collection point. These can be found in the trade (point of sale), at communities or local
authorities, but you can also return the battery to us.
Jauch Quartz GmbH is registered at the Federal Environment Agency with the registration number
21000702.
Electronic devices: Old electrical devices are not allowed to be disposed of with normal household
waste. In accordance with Directive 2012/19/EU, the device must be disposed of in a controlled
manner at the end of its service life. The materials contained in the system must be recycled in
order to reduce the environmental impact. This power station contains lithium-ion batteries. These
are hazardous goods that are subject to special transport and handling regulations. Lithium-ion
batteries can ignite or explode if handled improperly. To ensure safe disposal of this power station,
contact a collection point or local authority for more information.
Jauch Quartz GmbH is registered in accordance with ElektroG with the number DE49812498.
Packaging: The product packaging consists of recyclable materials. These are to be disposed of in
an environmentally friendly manner, whereby the materials are to be placed separately in the
collection systems provided.
Jauch Quartz GmbH is registered in accordance with the German Packaging Act (VerpackungsG)
under the number DE2423097819895 with the Central Packaging Register Office.
1. Complaints due to incomplete or incorrect delivery or complaints due to recognizable
1. Complaints due to incomplete or incorrect delivery or complaints due to recognizable defects
are to be notified to us or your supplying dealer/ distributor in writing immediately, at the
latest however within two weeks after receipt of the goods. Other defects are to be reported to
us or your supplying dealer/ distributor in writing immediately, at the latest within two weeks
after discovery. Warranty claims are excluded if complaints or notifications of defects are not
communicated in due time. In the event of timely notification, we shall be obliged to provide a
warranty in accordance with Section VII.
2. If there is transport damage, a railway or post damage assessment or such from a carrier is to
be provided to us by the customer.
3. Defects being present in only part of the delivered goods do not entitle the customer to
complain about the entire delivery, unless the partial delivery is of no interest to the customer.
WASTE AND RECYCLING
COMPLAINTS

1. In the event of defects in the delivered goods, we shall be entitled at our discretion to remedy
the defects or make a replacement delivery within a warranty period of 12 (twelve) months.
This does not apply if the law prescribes longer periods. In the event of rectification of defects,
we shall be obliged in accordance with the statutory provisions to bear the expenses required
for the purpose of rectifying the defects, provided that such expenses are not increased by the
fact that the goods have been transported to a place other than the place of performance.
2. The customer shall grant us sufficient time and opportunity required at our reasonable
discretion to remedy the defect. Replaced parts become our property.
3. If the subsequent performance fails, or a reasonable period of grace granted to us expires
without delivering again or remedying the defect, or if the subsequent performance is
impossible or is refused by us or your supplying dealer/ distributor, the customer shall have
the right to withdraw from the contract or to reduce the purchase price as well as in the event
of our inability to perform the subsequent performance.
4. The warranty does not apply to defects and/or damage resulting from natural wear and tear,
nor to defects and/or damage resulting from faulty or negligent handling, excessive strain,
unsuitable use, incorrect handling, etc., nor to such influences not assumed under the contract,
unless the damage is attributable to our fault.
5. The warranty claim cannot be transferred to third parties without our consent.
6. We shall not be liable for the resulting defects in the event of improper modifications and repair
work on the delivery items carried out by the customer or third parties.
7. Our liability for essential third-party products shall be limited to the assignment of the warranty
claims to which we are entitled against the supplier of the third-party product, unless the
satisfaction of the assigned right fails, or the assigned claim cannot be enforced for other
reasons.
8. Further claims of the customer against us on whatever legal grounds are excluded, unless
otherwise stipulated below, in particular claims for compensation for damages which do not
arise and/or exist on the delivered goods themselves (e.g. loss of profit, consequential
damages, other financial losses). This exemption from liability does not apply if we are
compulsorily liable as a result of intent, gross negligence or a promise of guarantee or if an
essential contractual obligation has been breached or in the event of injury to life, limb or
health.
9. In case of negligence, but not gross negligence, our liability is limited to the compensation of
the typical, foreseeable damage.
10. The above provisions shall apply mutatis mutandis to the delivery of goods other than those
stipulated in the contract.
How to receive service
To obtain warranty service, you must contact our customer service team via telephone at (+1) 360-
633-7200 or (+49) 07720 945 314, or via email at energysolutions@jauch.com.
WARRANTY

Bedienungsanleitung
Jauch Power Station JES1500WHA

Vielen Dank, dass Sie sich für den Kauf dieser Jauch Powerstation entschieden haben. Bitte lesen
Sie vor Inbetriebnahme dieser Powerstation alle Anweisungen und Warnhinweise aufmerksam
durch, um Personen- und Sachschäden zu vermeiden.
NUTZUNG AUSSCHLIESSLICH IN BELÜFTETEN BEREICHEN
Stellen Sie während des Gebrauchs eine ausreichende Luftzufuhr sicher und achten Sie darauf, dass
die Lüftungsöffnungen der Powerstation nicht behindert werden. Unzureichende Belüftung kann zu
Schäden an dieser Powerstation führen.
Das intelligente Kühlungssystem dieser Powerstation schaltet unter folgenden Gegebenheiten
automatisch die Lüftungsfunktionen an:
• Wechselrichterlast > 400W
• 5V USB Last > 10W
• USB-C PD Last > 30W
• 12V Zigarettenanzünder Last > 50W
• PV Eingangsleistung > 100W.
KEINE BENUTZUNG IM NASSEN ZUSTAND
Um Kurzschlüsse zu vermeiden, verwenden Sie die Powerstation bitte nicht im nassen oder
feuchten Zustand.
Jegliche Veränderungen an dieser Powerstationen oder Komponenten führt zum Erlöschen
aller Gewährleistungen.
A
Ein-/Aus-Schalter Powerstation
B
Ein-/Aus-Schalter DC Ausgang
C
Ein-/Aus-Schalter AC Ausgang
D
LED Anzeige
E
USB Ausgänge
F
USB-C Ausgang
G
LCD-Bildschirm
H
Eingangsbuchse
I
Zigarettenanzünder Ausgang (12V)
WICHTIGE SICHERHEITSHINWEISE
LERNEN SIE IHRE JAUCH POWERSTATION KENNEN

1
Jauch Power Bank JES1500WHA
2
Netzteil
3
Verbindungskabel für Solar Panel (7909 to MC4)
4
Jauch Bedienungsanleitung
Ein-/Aus-Schalter Powerstation
Einschalten der Powerstation: Halten Sie den Ein-/Aus-
Schalter ca. zwei Sekunden gedrückt. Der Bildschirm leuchtet
auf.
Ausschalten der Powerstation: Halten Sie den Ein-/Aus-
Schalter ca. zwei Sekunden gedrückt.
Ein-/Aus-Schalter DC Ausgang
Einschalten des DC-Ausgangs: Halten Sie den DC-Schalter ca.
zwei Sekunden gedrückt. Die entsprechende DC-
Kontrollleuchte leuchtet auf und auf dem Display wird „DC
ON“ angezeigt.
Ausschalten des DC-Ausgangs: Halten Sie den DC-Schalter ca.
zwei Sekunden gedrückt. Die entsprechende DC-
Kontrollleuchte erlischt und auf dem Display wird „DC OFF“
angezeigt.
Power Button AC Ausgang
Einschalten des AC-Ausgangs: Halten Sie den AC-Schalter ca.
zwei Sekunden gedrückt. Die entsprechende AC-
Kontrollleuchte leuchtet auf und auf dem Display wird „AC
ON“ angezeigt.
BESCHREIBUNG DER TASTEN UND BILDSCHIRMANZEIGEN
LIEFERUMFANG

Ausschalten des AC-Ausgangs: Halten Sie den AC-Schalter ca.
zwei Sekunden gedrückt. Die entsprechende AC-
Kontrollleuchte erlischt und auf dem Display wird „AC OFF“
angezeigt.
Hinweis: Wenn die Powerstation ausgeschalten ist, werden
die AC-Ausgänge automatisch deaktiviert. Diese müssen
nach Anschalten der Powerstation manuell aktiviert werden.
Halten Sie dafür den AC-
Schalter ca. zwei Sekunden
gedrückt, um den AC-Eingang zu aktivieren.
lCD Display
Das eingebaute LCD-Display zeigt Ihnen drei Informationen an:
Eingangsleistung
Zeigt die Leistung in Watt an, welche während des Ladevorgangs in die
Powerstation fließt.
Ausgangsleistung
Zeigt die Leistung in Watt an, welche die angeschlossenen Geräte
verbrauchen, während sie an die Powerstation angeschlossen sind.
Akku-
Ladezustand
Zeigt den verbleibenenden Ladezustand der Powerstation in fünf
Segmenten (20%, 40%, 60%, 80% und 100%) an. Wenn Sie über die
Powerstation Ihre Endgeräte laden, verschwindet die
Segmentanzeige; es wird die verbleibende Restladung der
Powerstation angezeigt.
Während des Ladevorgangs der Powerstation blinkt das
Batteriesymbol und zeigt den aktuellen Ladezustand an.
Hinweis: Bei internen Fehlern der Powerstation wird rechts im Bildschirm ein Fehlercode angezeigt.
Die Erläuterung des jeweiligen Fehlercodes sowie Hinweise zur Behebung des Fehlers finden Sie
nachfolgend in der Bedienungsanleitung.
Bitte laden Sie die Powerstation vor erstmaligem Gebrauch über eine haushaltsübliche
Wandsteckdose vollständig auf.
Die Powerstation verfügt über drei Lade-Modi: Über ein Solar Panel, über einen KFZ-
Zigarettenanzünder oder per Wandsteckdose.
AUFLADEN IHRER JAUCH POWERSTATION

Diese Jauch Powerstation verfügt über einen eingebauten Regelkreis. Sobald die Powerstation
vollständig geladen wurde, stoppt der Ladevorgang automatisch.
Bitte beachten Sie, dass das Gerät nur in einer Umgebungstemperatur zwischen 0°C und +40°C
(32°F und 104°F) geladen werden darf.
AUFLADEN PER SOLAR PANEL
Um die Powerstation über ein Solar Panel aufzuladen, platzieren Sie das Solar Panel im direkten
Sonnenlicht. Verbinden Sie das Solar Panel mit dem DC-Eingang der Powerstation (DC 16-
60V/10A). Sobald die Powerstation anfängt zu laden, leuchtet der Bildschirm auf und zeigt die
Eingangsleistung an.
Wenn Sie die AC- oder DC-Ausgänge während des Ladevorgangs nutzen möchten, halten Sie den
AC- bzw. DC-Schalter für mindestens eine Sekunde gedrückt.
AUFLADEN ÜBER EINEN KFZ-ZIGARETTENANZÜNDER
Verbinden Sie das entsprechende Kabel mit Zigaretten-Anzünder-Stecker mit dem
Zigarettenanzünder Ihres Autos und der DC-Eingangsbuchse der Powerstation. Sobald der
Ladevorgang eingeleitet wird, blinkt das Batteriesymbol im Display; die Eingangsleistung wird
angezeigt.

Hinweis: Bitte beachten Sie, dass diese Jauch Powerstation nicht vollständig geladen werden kann,
wenn sie an eine 12V-Autobatterie angeschlossen ist.
AUFLADEN ÜBER DEN AC-EINGANG
Um die Powerstation über eine herkömmliche Wandsteckdose aufzuladen, verbinden Sie das
beiliegende Netzteil mit der Steckdose und der Eingangsbuchse der Powerstation. Sobald der
Ladevorgang eingeleitet wurde, beginnt das Batteriesymbol zu blinken und zeigt die
Eingangsleistung an.
BENUTZUNG DER USB-AUSGÄNGE
Verbinden Sie Ihr mobiles Gerät über ein USB-Kabel mit den USB-Ausgängen der Powerstation.
Sobald die Verbindung hergestellt ist, beginnt der Ladevorgang automatisch.
BENUTZUNG DER DC-AUSGÄNGE
Schließen Sie das DC-Kabel an die Eingangsbuchse Ihres Endgeräts sowie dem DC-Ausgang der
Powerstation an. Sobald die Verbindung hergestellt ist, beginnt der Ladevorgang automatisch.
BENUTZUNG DER USB-C AUSGÄNGE
Verbinden Sie das USB-C Kabel mit der USB-C-Ausgangsbuchse der Powerstation und der
Eingangsbuchse Ihres Endgeräts. Sobald die Verbindung hergestellt ist, beginnt der Ladevorgang
automatisch.
BENUTZUNG DER AC-AUSGÄNGE
Schließen Sie das Netzteil an den Eingangsanschluss Ihres Geräts an. Das andere Ende des Netzteil
verbinden Sie mit einem der AC-Ausgänge der Powerstation. Sobald die Verbindung hergestellt ist,
beginnt der Ladevorgang automatisch.
Hinweis: Wenn die Powerstation ausgeschalten wurde, werden die AC-Ausgänge automatisch
deaktiviert. Drücken Sie daher den AC-Schalter für mehrere Sekunden, um den Ausgang zu
aktivieren.
BENUTZUNG IHRER JAUCH POWER STATION

Bitte laden Sie diese Jauch Powerstation vor Lagerung vollständig auf und wiederholen Sie dies alle
drei Monate. Halten Sie die Powerstation fern von:
• Wasser/ Flüssigkeiten
• Brennbaren Gasen
• Korrosiven Stoffen
• Metallen
• Staub und Salz
Nichtbeachtung dieser Anweisungen kann zu Schäden an der Powerstation kommen, was zum
Erlöschen der Gewährleistung führt!
Allgemeine Informationen
Nennlistung der Batterie
1500Wh
Nennspannung der Batterie
14.8Vdc
Abmessungen
371x165x364 mm/ 14.5x6.5x14.5 in
Gewicht
17.2 kg/ 38 LBS
Betriebstemperatur
0°C-40°C/ 32°F-104°F
Geeignete Lagertemperatur
-20°C- +40°C/ 4°F-104°F (bei 10-90% Feuchtigkeit)
Internationale Schutzklasse
IP21
Ausgabe AC Wechselrichter
Nennleistung | Spitzenleistung
1000W
Nennspannung
110Vac (US Version) / 230Vac (EU und UK Version)
Nennfrequenz
50/60Hz
Leistungsfaktor
1
THDV@0.7R Load
<5%
Überlast
1000W<load<1500W@2min
1500W<load@1s
No-Load Power Consumption
<8W
Max. Effizienz (>70% Load Power)
88% (US Version)/ 90% (EU und UK Version)
Ausgabe USB, USB-C und DC
Ausgabe USB
5V, 3A
Max. Ausgabe für einen USB-Port: 3A
Max. Ausgabe beträgt 3A bei Nutzung von zwei USB-Ports
gleichzeitig
Ausgabe USB-C (PD2.0)
5-20V (Standard: 5V)
5V/9V/12V/15V 3A
20V 2.25A
Schnellladeprotokoll: PD 2.0 (Max. 45W)
Ausgabe DC
12.2V/9A
Eingang Powerstation
AC Adapterladegerät
42V/ 160W
PV (Solar Panel) max. Eingangsleistung
600W
PV (Solar Panel) Eingangsspannungsbereich
16-60Vdc
PV (Solar Panel) max. Eingangsstrom
10A
PV Ladetyp
MPPT
MPPT Effizienz
>88%
Spezifikationen Batterie
Nennleistung der Batterie
14.8Vdc
Nennenergie der Batterie
1500Wh
Zelltype
Li-Ion
TECHNISCHE SPEZIFIKATIONEN
AUFBEWAHRUNG UND WARTUNG
FEHLERBEHEBUNG

Der folgende Leitfaden enthält Informationen zur Identifizierung und Behebung von Fehlern.
Fehlercode
Ursache
Fehlerbehebung
E01
Überspannungsschutz aller Batterien
Keine Ladung, nur Entladung
E02
Überspannungsschutz aller Batterien
Vollständig laden und neu starten.
E03
Ausfall aller Batterien
Powerstation neu starten und aufladen.
E04
Übertemperaturschutz Entladung aller Batterien
Temperatur zu hoch. Nach Abkühlung neu
starten.
E05
Niedrigtemperaturschutz Entladung aller
Batterien
Umgebungstemperatur zu niedrig. bei höherer
Umgebungstemperatur neu starten.
E06
Ladeübertemperaturschutz aller Batterien
Die Temperatur der Powerstation ist zu niedrig.
Bei höherer Temperatur aufladen.
E07
Ladeuntertemperaturschutz aller Batterien
Die Temperatur der Powerstation ist zu hoch.
E08
Unterspannungsschutz 1. Batteriengruppe
Vollständig laden und neu starten.
E09
Unterspannungsschutz 2. Batteriengruppe
Vollständig laden und neu starten.
E10
Unterspannungsschutz 3. Batteriengruppe
Vollständig laden und neu starten.
E11
Unterspannungsschutz 4. Batteriengruppe
Vollständig laden und neu starten.
E12
Spannungsausfall AC-Wechselrichter
Abschalten und neu starten.
E13
Überlastungsschutz Wechselrichter
Last reduzieren und AC neu starten
E14
Kurzschluss Wechselrichter
Ausgangsspannung reduzieren und AC neu
starten.
E15
Übertemperaturschutz Kühlgebläse AC-
Wechselrichter
Bei niedrigerer Kühlgebläsetemperatur neu
starten.
E16
Fehler an Temperatursensor
Kühlergebläsetemperatur AC-Wechselrichter
NTC anschließen und neu starten.
E17
Überspannungssschutz PV-Eingang (Solar Panel)
Überprüfen, um sicherzustellen, dass das die
Solarmodul korrekt konfiguriert worden ist, um
die richtige Eingangsspannung zu liefern.
Wenn ja: PV trennen, neu anschalten und PV
anschließen.
E18
Interner Überhitzungsschutz
Überprüfen, ob Betriebstemperatur zu hoch
ist. Liegt die Temperatur im Betriebsbereich,
PV trennen, Gerät abschalten und dann PV neu
anschließen.
E19
Übertemperaturschutz PV-Kühlgebläse (Solar
Panel
Powerstation neu laden, nachdem die Temperatur
des Kühlgebläses abgekühlt ist.
E20
Temperatursensor PV-Kühlgebläse funktioniert
nicht
JES1500WHA neu starten.
E21
Ladeschutz Batterieschutz-Bord
Nach Erreichen der Normaltemperatur des
Schutz-Boards aufladen.
E22
Batterieselbstschutz
PV trennen. Neu starten.
E23
Generatorüberlastschutz (AC & DC)
Gesamtlast reduzieren und neu starten.
Sollten Sie nach den genannten Maßnahmen zur Fehlerbehandlung immer noch Probleme mit Ihrer
Jauch Powerstation haben, wenden Sie sich bitte an unseren Kunden Service unter +(1) 360 633
7200 oder (+49) 07720 945 0 oder per E-Mail an contact@jauchpowerondemand.com.

Lithium Ionen Batterie: Sobald die Powerstation das Ende ihrer Lebenszeit erreicht
hat, kann die gesamte Lithium-Ionen-Batterie recycelt werden.
Gemäß der Europäischen Richtlinie 2006/66/EC, in den jeweiligen EU-
Mitgliedsstaaten umgesetzt in nationales Recht, dürfen Batterien nicht über den
Hausmüll entsorgt werden. Verbraucher sind verpflichtet, Batterien zu einer
geeigneten Sammelstelle zu bringen. Diese sind im Handel zu finden (Verkaufsstelle), bei
Gemeinden oder Kommunen, Sie die die Batterie aber auch an uns zurücksenden.
Die Jauch Quartz GmbH ist beim Umweltbundesamt mit der Melderegisternummer 21000702
registriert.
Elektronische Geräte: Alte Elektrogeräte dürfen icht zusammen mit normalem Hausmüll ensorgt
werden. Gemäß der Richtlinie 2012/19/EU muss das Gerät zum Ende seiner Lebenszeit kontrolliert
entsorgt werden. Die im System enthaltenen Materialien sind dem Recycling zuzufüren, um die
Umweltbelastung zu reduzieren. Diese Powerstation enthält Lithium-Ionen-Batterien. Dabei
handelt es sich um Gefahrgüter, die besonderen Transport- und Handhabungsvorschriften
unterliegen. Lithium-Ionen-Batterien können sich bei unsachgemäßem Umgang entzünden oder
explodieren. Zur Sicherung der Entsorgung dieser Powerstation ist für weitere Informationen eine
Sammelstelle oder die lokale Kommune zu kontaktieren.
Die Jauch Quartz GmbH ist gemäß ElektroG mit der Nummer DE49812498 registriert.
Verpackung: Die Produktverpackung besteht aus recycelbaren Materialien. Diese sind
umweltfreundlich zu entsorgen, wobei die Materialien getrennt in die zur Verfügung gestellten
Sammelsysteme zu geben sind.
Die Jauch Quartz GmbH ist gemäß VerpackungsG unter der Nummer DE2423097819895 bei der
Zentralen Stelle Verpackungsregister registriert.
1. Beanstandungen wegen unvollständiger oder unrichtiger Lieferung oder Rügen wegen
erkennbarer Mängel sind uns unverzüglich, spätestens jedoch innerhalb von 2 Wochen nach
Empfang der Ware, schriftlich mitzuteilen. Andere Mängel sind unverzüglich, spätestens jedoch
innerhalb von 2 Wochen nach Entdeckung schriftlich mitzuteilen. Bei nicht rechtzeitiger
Mitteilung von Beanstandungen oder Mängelrügen sind Gewährleistungsansprüche
ausgeschlossen. Bei rechtzeitiger Mitteilung sind wir zur Gewährleistung nach Abschnitt VII.
verpflichtet.
2. Bei Transportschäden ist uns vom Besteller eine bahn- oder postseitige Schadensfeststellung
oder eine solche des Transporteurs zu beschaffen.
3. Mängel eines Teils der gelieferten Waren berechtigen den Besteller nicht zur Beanstandung der
gesamten Lieferung, es sei denn, dass die Teillieferung für den Besteller nicht von Interesse
ist.
ENTSORGUNG UND RECYCLING (IN EUROPA)
BEANSTANDUNGEN UND MÄNGEL
Table of contents
Languages:
Other Jauch Portable Generator manuals
Popular Portable Generator manuals by other brands

RAFFEL SYSTEMS
RAFFEL SYSTEMS ACC PS2 QU2 01 user manual

Sunbird Solar
Sunbird Solar solarpod pro 1000 user manual

Hyundai power products
Hyundai power products HP7500CXE Use and maintenance manual

Tektronix
Tektronix AWVG1 user manual

Toyama
Toyama TG12000CXNE owner's manual

Denyo
Denyo DCA-600SPK instruction manual

Atlas Copco
Atlas Copco QLT M10 instruction manual

Champion Power Equipment
Champion Power Equipment 100331 owner's manual

Gentech
Gentech Power Master PM-1200 reference guide

Schumacher
Schumacher SL1404 owner's manual

Powermate
Powermate Maxa 5000 ER PL0525202.02 manual

CMP
CMP DEL Ozone ABG 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL