jcm-tech CONNECT4 CC User manual

CONNECT4 CC
User Manual / Manuel de l’utilisateur

Table of contents / Index
Important safety instructions 3
Use of the equipment 3
Introduction 4
Installation and connections 4
Operating 5
Wiegand formats: 5
Configuration and connection for the different protocols 6
* Facility Code: SW1-8, 0= OFF/1= ON 6
Groups 9
Group configuration 9
Notes 10
Technical data 11
Regulatory Data 11
FCC / ISED Compliance 11
Consignes importantes de sécurité 12
Utilisation de l'appareil 12
Introduction 13
Installation et connections 13
Fonctionnement 14
Formats Wiegand : 14
Configuration et connexion pour les différents protocoles 15
* Code d’installation : SW1-8, 0= ÉTEINT/1= ALLUMÉ 15
Groupes 18
Configuration des groupes 18
Notes 19
Données techniques 20
Données réglementaires 20
Conformité FCC / ISED 20
jcmtechnologies
2

Important safety instructions
Disconnect thepower supplywhenever you proceed with theinstallation or repair of
theequipment.
In compliance with the European Low Voltage Directive, we inform you of the following requirements:
•When the devices remain permanently connected, an easily accessible connecting device must be incorporated into the wiring.
•This system must only be installed by qqualified professionals that have experience with automated garage doors and know-
ledge of the relevant European standards.
•The user instructions for this device must always be in the user’s possession.
•The operating frequency of the receiver does not interfere in any way with the 868 MHz remote control systems.
Use of the equipment
This device is designed for applications with an automated garage door. It is not guaranteed for the direct activation of
devices other than those specified. The manufacturer reserves the right to change the specifications of the device without
warning.
jcmtechnologies
3

Introduction
Multiprotocol receiver compatible with MOTION transmitters. Codifies the transmitter signal in two different protocols
according to its configuration: Wiegand 26 and Wiegand 37.
Installation and connections
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the cables through the bottom of
the receiver. Connect the power cables to the terminals marked on the mother board, as indicated. Fix the receiver front
to the rear part using the screws supplied.
jcmtechnologies
4

Operating
The CONNECT-MCH FC is a receiver that will pass incoming frames from remote controls via a selected channel (1 out of
4) towards a central (Led TX= ON).
The channel depends on the button that is pressed on the remote control.
The frame that is delivered at D0-D1 of channel CH1/CH2/CH3/CH4 is of type WIEGAND.
Wiegand formats:
W26, NO Facility Code:
•1 bit - Even parity (of next 12 bits)
•4 bit – Zeros
•20 bit – Remote control number, complete.
•1 bit - Odd parity (of last 12 bits)
W26, with Facility CODE:
•1 bit - Even parity (of next 12 bits)
•8 bit – Facility Code as set by 8 switches.
•16 bit – Remote control number, lower part (*)
•1 bit - Odd parity (of last 12 bits)
(*): up to 65536 remote controls with consecutive numbers may be used.
W37:
•1 bit - Even parity (of next 18 bits)
•8 bit – Counter
•2 bit – Zeros
•3 bit – Substitute
•3 bit – Channel DCS
•19 bit – Remote control number
•1 bit - Odd parity (of last 18 bits)
jcmtechnologies
5

Configuration and connection for the different protocols
Switch SW1 allows to select the short W26 (SW1= OFF) or the long W37 (SW1= ON) format.
In case the short W26 is selected, the content of the frame may be NOFC (SW2= OFF), or include a so called Facility
Code (SW2= ON).
In this case, the value of the Facility Code in Binary is set by 8 switches, each one defining either a 0= OFF or 1= ON.
Protocol Power
Remote
Control
Signal
Output SW1 SW2
Facility
Code 1 to
8 Bits FRAME FORMAT
W26 NO
Facility
Code
+ - Button
1/2/3/4
CH1/2/3/4
D0-D1 OFF OFF don't care EP(1)-Zeros(4)-Remote Control
Number(20)-OP(1)
W37 + - Button
1/2/3/4
CH1/2/3/4
D0-D1 ON don't
care don't care
EP(1)-Counter(8)-Zeros(2)-Sub(3)-
DCS(3)-Remote Control Number(19)-
OP(1)
W26 with
Facility
Code
+ - Button
1/2/3/4
CH1/2/3/4
D0-D1 OFF ON
mode
Facility
Code *
EP(1)-Facility Code(8)-Remote Control
Number(16)-OP(1)
*Facility Code: SW1-8, 0=OFF/1=ON
DEC BIN DEC BIN DEC BIN DEC BIN
0 00000000 16 00010000 32 00100000 48 00110000
1 00000001 17 00010001 33 00100001 49 00110001
2 00000010 18 00010010 34 00100010 50 00110010
3 00000011 19 00010011 35 00100011 51 00110011
4 00000100 20 00010100 36 00100100 52 00110100
5 00000101 21 00010101 37 00100101 53 00110101
6 00000110 22 00010110 38 00100110 54 00110110
7 00000111 23 00010111 39 00100111 55 00110111
8 00001000 24 00011000 40 00101000 56 00111000
9 00001001 25 00011001 41 00101001 57 00111001
10 00001010 26 00011010 42 00101010 58 00111010
11 00001011 27 00011011 43 00101011 59 00111011
12 00001100 28 00011100 44 00101100 60 00111100
13 00001101 29 00011101 45 00101101 61 00111101
14 00001110 30 00011110 46 00101110 62 00111110
15 00001111 31 00011111 47 00101111 63 00111111
jcmtechnologies
6

DEC BIN DEC BIN DEC BIN DEC BIN
64 01000000 80 01010000 96 01100000 112 01110000
65 01000001 81 01010001 97 01100001 113 01110001
66 01000010 82 01010010 98 01100010 114 01110010
67 01000011 83 01010011 99 01100011 115 01110011
68 01000100 84 01010100 100 01100100 116 01110100
69 01000101 85 01010101 101 01100101 117 01110101
70 01000110 86 01010110 102 01100110 118 01110110
71 01000111 87 01010111 103 01100111 119 01110111
72 01001000 88 01011000 104 01101000 120 01111000
73 01001001 89 01011001 105 01101001 121 01111001
74 01001010 90 01011010 106 01101010 122 01111010
75 01001011 91 01011011 107 01101011 123 01111011
76 01001100 92 01011100 108 01101100 124 01111100
77 01001101 93 01011101 109 01101101 125 01111101
78 01001110 94 01011110 110 01101110 126 01111110
79 01001111 95 01011111 111 01101111 127 01111111
DEC BIN DEC BIN DEC BIN DEC BIN
128 10000000 144 10010000 160 10100000 176 10110000
129 10000001 145 10010001 161 10100001 177 10110001
130 10000010 146 10010010 162 10100010 178 10110010
131 10000011 147 10010011 163 10100011 179 10110011
132 10000100 148 10010100 164 10100100 180 10110100
133 10000101 149 10010101 165 10100101 181 10110101
134 10000110 150 10010110 166 10100110 182 10110110
135 10000111 151 10010111 167 10100111 183 10110111
136 10001000 152 10011000 168 10101000 184 10111000
137 10001001 153 10011001 169 10101001 185 10111001
138 10001010 154 10011010 170 10101010 186 10111010
139 10001011 155 10011011 171 10101011 187 10111011
140 10001100 156 10011100 172 10101100 188 10111100
141 10001101 157 10011101 173 10101101 189 10111101
142 10001110 158 10011110 174 10101110 190 10111110
143 10001111 159 10011111 175 10101111 191 10111111
jcmtechnologies
7

DEC BIN DEC BIN DEC BIN DEC BIN
192 11000000 208 11010000 224 11100000 240 11110000
193 11000001 209 11010001 225 11100001 241 11110001
194 11000010 210 11010010 226 11100010 242 11110010
195 11000011 211 11010011 227 11100011 243 11110011
196 11000100 212 11010100 228 11100100 244 11110100
197 11000101 213 11010101 229 11100101 245 11110101
198 11000110 214 11010110 230 11100110 246 11110110
199 11000111 215 11010111 231 11100111 247 11110111
200 11001000 216 11011000 232 11101000 248 11111000
201 11001001 217 11011001 233 11101001 249 11111001
202 11001010 218 11011010 234 11101010 250 11111010
203 11001011 219 11011011 235 11101011 251 11111011
204 11001100 220 11011100 236 11101100 252 11111100
205 11001101 221 11011101 237 11101101 253 11111101
206 11001110 222 11011110 238 11101110 254 11111110
207 11001111 223 11011111 239 11101111 255 11111111
jcmtechnologies
8

Groups
Receivers can be configured with a group (from 0 to 7) so that there is no interference when working near each other.
Group configuration
The configuration can be carried out with the programming tool or by self-programming as follows.
Self-programming: After the receiver has been totally reset, it will be configured with the group of the first radio-pro-
grammed transmitter by enabling the hands free mode.
Exception: If the receiver has been configured using programming tools, the group may only be changed with the pro-
gramming tool.
Operations: On powering the receiver, the led R1 will flash the same number of times as the group number with which it
is configured.
C = channel
G= group
Group 0 enables all groups.
jcmtechnologies
9

Notes
jcmtechnologies
10

Technical data
Parameter Value
Power Supply 12V dc (9Vdc-21Vdc)
Frequency 868,35MHz
Consumption standby / operating 14mA/36mA
Operating temperature -20ºC / +85ºC
Size (L/W/H) 82x190x40mm
Watertighness IP54 (with cable gland IP65)
Regulatory Data
FCC / ISED Compliance
Model: CONNECT4 CC, CONNECT4 ACT, CONNECT4 CC-CIC
FCC ID: U5Z-CONNECT4CC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Part 15 of the FCC Rules and with Innov-
ation, Science and Economic Development Canada’s licence-exempt RSS(s) .
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
CAN ICES-003 (B)
This Class B digital apparatus complies with Canadian ICES-003.
UM_3201676_CONNECT4-CC_EN-FR_Rev00
jcmtechnologies
11
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.

Consignes importantes de sécurité
Débrancher l’alimentation quand vousprocédezàl’installation ou à la réparation de
l’appareil.
•Pour les appareils branchés en permanence, un dispositif de connexion facilement accessible devra être intégré au câblage.
•Ce système ne doit être installé que par un personnel qualifié possédant une expérience dans les portes de garage automatiques
et une connaissance des règles canadien sur le sujet.
•Le manuel d’utilisation de cet appareil devra toujours demeurer en possession de l’utilisateur.
•La fréquence de travail du récepteur n’interfère en aucune manière avec les systèmes à télécommande 868 MHz.
Utilisation de l'appareil
Cet appareil est conçu pour l'automatisation de portes de garage selon la description générale. Il n'est pas garantie pour
des utilisations autres. Le fabricant se réserve le droit de modifier les caractéristiques techniques des appareils sans
préavis.
jcmtechnologies
12

Introduction
Récepteur multiprotocole compatible avec les émetteurs MOTION. Codifie le signal de l’émetteur en deux protocoles
différents en fonction de sa configuration : Wiegand 26 et Wiegand 37.
Installation et connections
Fixer la partie postérieure du boîtier au mur en utilisant les chevilles et vis fournies à cet effet. Passer les câbles par la
partie inférieure du récepteur. Connecter les câbles d’alimentation aux bornes marquées, en suivant les instructions de
celui-ci. Fixer la partie frontale du récepteur en utilisant les vis fournies.
jcmtechnologies
13

Fonctionnement
CONNECT-MCH FC est un récepteur qui transmet les trames entrantes des télécommandes via un canal sélectionné (1
sur 4) vers une centrale (LED TX = ALLUMÉE).
Le canal dépend de la touche activée sur la télécommande.
La trame qui est délivrée en D0-D1 du canal CH1/CH2/CH3/CH4 est de type WIEGAND.
Formats Wiegand :
W26, SANS Code d’installation :
•1 bit - Parité paire (des 12 bits suivants)
•4 bits – Zéros
•20 bits – Numéro de télécommande, complet.
•1 bit - Parité impaire (des 12 derniers bits)
W26, AVEC Code d’installation :
•1 bit - Parité paire (des 12 bits suivants)
•8 bits – Code d’installation tel que défini par 8 interrupteurs.
•16 bits – Numéro de télécommande, partie inférieure (*).
•1 bit - Parité impaire (des 12 derniers bits)
(* ) : possibilité d’utiliser jusqu’à 65 536 télécommandes avec numéros consécutifs.
W37 :
•1 bit - Parité paire (des 18 bits suivants)
•8 bits – Compteur
•2 bits – Zéros
•3 bits – Remplaçant
•3 bit – Canal DCS
•19 bits – Numéro de télécommande
•1 bit - Parité impaire (des 18 derniers bits)
jcmtechnologies
14

Configuration et connexion pour les différents protocoles
L’interrupteur SW1 permet de sélectionner le format court W26 (SW1= ÉTEINT) ou le format long W37 (SW1=
ALLUMÉ).
Si le format W26 court est sélectionné, le contenu de la trame peut être NOFC (SW2= ÉTEINT) ou inclure un Code
appelé Code d’installation (SW2= ALLUMÉ).
Dans ce cas, la valeur du Code d’installation en binaire est réglée par 8 interrupteurs, chacun d’eux définissant soit un
0= ÉTEINT ou 1= ALLUMÉ.
Protocole Puissance Télécommande
Sortie sig-
nal SW1 SW2
Code
d’installation
1 sur 8 bits FORMAT DE TRAME
W26 SANS
Code
d’installation
+ - Touche 1/2/3/4 CH1/2/3/4
D0-D1 OFF OFF indifférent
EP(1)-Zéros(4)-
Numéro de
télécommande (20)-
OP(1)
W37 + - Touche 1/2/3/4 CH1/2/3/4
D0-D1 ON indifférent indifférent
EP(1)-Compteur (8)-
Zéros(2)-Sub(3)-
DCS(3)-Numéro de
télécommande(19)-
OP(1)
W26 avec
Code
d’installation
+ - Touche 1/2/3/4 CH1/2/3/4
D0-D1 OFF ON
mode Code
d’installation
*
EP(1)-Code
d’installation (8)-
Numéro de
télécommande (16)-
OP(1)
*Code d’installation : SW1-8, 0= ÉTEINT/1=ALLUMÉ
DEC BIN DEC BIN DEC BIN DEC BIN
0 00000000 16 00010000 32 00100000 48 00110000
1 00000001 17 00010001 33 00100001 49 00110001
2 00000010 18 00010010 34 00100010 50 00110010
3 00000011 19 00010011 35 00100011 51 00110011
4 00000100 20 00010100 36 00100100 52 00110100
5 00000101 21 00010101 37 00100101 53 00110101
6 00000110 22 00010110 38 00100110 54 00110110
7 00000111 23 00010111 39 00100111 55 00110111
8 00001000 24 00011000 40 00101000 56 00111000
9 00001001 25 00011001 41 00101001 57 00111001
10 00001010 26 00011010 42 00101010 58 00111010
11 00001011 27 00011011 43 00101011 59 00111011
12 00001100 28 00011100 44 00101100 60 00111100
13 00001101 29 00011101 45 00101101 61 00111101
14 00001110 30 00011110 46 00101110 62 00111110
15 00001111 31 00011111 47 00101111 63 00111111
jcmtechnologies
15

DEC BIN DEC BIN DEC BIN DEC BIN
64 01000000 80 01010000 96 01100000 112 01110000
65 01000001 81 01010001 97 01100001 113 01110001
66 01000010 82 01010010 98 01100010 114 01110010
67 01000011 83 01010011 99 01100011 115 01110011
68 01000100 84 01010100 100 01100100 116 01110100
69 01000101 85 01010101 101 01100101 117 01110101
70 01000110 86 01010110 102 01100110 118 01110110
71 01000111 87 01010111 103 01100111 119 01110111
72 01001000 88 01011000 104 01101000 120 01111000
73 01001001 89 01011001 105 01101001 121 01111001
74 01001010 90 01011010 106 01101010 122 01111010
75 01001011 91 01011011 107 01101011 123 01111011
76 01001100 92 01011100 108 01101100 124 01111100
77 01001101 93 01011101 109 01101101 125 01111101
78 01001110 94 01011110 110 01101110 126 01111110
79 01001111 95 01011111 111 01101111 127 01111111
DEC BIN DEC BIN DEC BIN DEC BIN
128 10000000 144 10010000 160 10100000 176 10110000
129 10000001 145 10010001 161 10100001 177 10110001
130 10000010 146 10010010 162 10100010 178 10110010
131 10000011 147 10010011 163 10100011 179 10110011
132 10000100 148 10010100 164 10100100 180 10110100
133 10000101 149 10010101 165 10100101 181 10110101
134 10000110 150 10010110 166 10100110 182 10110110
135 10000111 151 10010111 167 10100111 183 10110111
136 10001000 152 10011000 168 10101000 184 10111000
137 10001001 153 10011001 169 10101001 185 10111001
138 10001010 154 10011010 170 10101010 186 10111010
139 10001011 155 10011011 171 10101011 187 10111011
140 10001100 156 10011100 172 10101100 188 10111100
141 10001101 157 10011101 173 10101101 189 10111101
142 10001110 158 10011110 174 10101110 190 10111110
143 10001111 159 10011111 175 10101111 191 10111111
jcmtechnologies
16

DEC BIN DEC BIN DEC BIN DEC BIN
192 11000000 208 11010000 224 11100000 240 11110000
193 11000001 209 11010001 225 11100001 241 11110001
194 11000010 210 11010010 226 11100010 242 11110010
195 11000011 211 11010011 227 11100011 243 11110011
196 11000100 212 11010100 228 11100100 244 11110100
197 11000101 213 11010101 229 11100101 245 11110101
198 11000110 214 11010110 230 11100110 246 11110110
199 11000111 215 11010111 231 11100111 247 11110111
200 11001000 216 11011000 232 11101000 248 11111000
201 11001001 217 11011001 233 11101001 249 11111001
202 11001010 218 11011010 234 11101010 250 11111010
203 11001011 219 11011011 235 11101011 251 11111011
204 11001100 220 11011100 236 11101100 252 11111100
205 11001101 221 11011101 237 11101101 253 11111101
206 11001110 222 11011110 238 11101110 254 11111110
207 11001111 223 11011111 239 11101111 255 11111111
jcmtechnologies
17

Groupes
Les récepteurs pourront être configurés avec un groupe (de 0 à 7), de manière à éviter les interférences lorsqu’ils trav-
ailleront à proximité les uns des autres.
Configuration des groupes
La configuration peut être exécutée avec l’outil de programmation ou par autoprogrammation comme suit.
Autoprogrammation: Après une réinitialisation totale du récepteur, celui-ci sera configuré avec le groupe du premier
émetteur programmé via radio, par activation mains libres.
Exception : si le récepteur a été configuré à l’aide de l’outil de programmation, le groupe pourra uniquement être changé
avec cet outil de programmation.
Fonctionnement: Lors de l’alimentation du récepteur, le voyant lumineux R1 effectuera le nombre d’intermittences cor-
respondant au numéro de groupe avec lequel il est configuré.
C = canal
G= groupe
Le groupe 0 active tous les groupes.
jcmtechnologies
18

Notes
jcmtechnologies
19

Données techniques
Paramètre Valeur
Alimentation 12V dc (9Vdc-21Vdc)
Fréquence 868,35MHz
Consommation repos / travail 14mA/36mA
Température travail -20ºC / +85ºC
Dimensions (L/W/H) 82x190x40mm
Étanchéité IP54 (avec presse-étoupes IP65)
Données réglementaires
Conformité FCC / ISED
Modèle: CONNECT4 CC, CONNECT4 ACT, CONNECT4 CC-CIC
FCC ID: U5Z-CONNECT4CC
Les changements ou modifications non expressément approuvés par la partie responsable de la conformité peuvent
annuler le droit de l'utilisateur à utiliser l'équipement.
L'équipement contient des émetteurs/récepteurs exempts de licence qui sont conformes à la Part 15 des règles de la FCC
et aux RSS exempts de licence d'Innovation, Sciences et Développement Économique Canada.
L’exploitation est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage.
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre
le fonctionnement
CAN NMB-003 (B)
Cet appareil numérique de classe B est conforme à la norme canadienne NMB-003.
UM_3201676_CONNECT4-CC_EN-FR_Rev00
jcmtechnologies
20
Table of contents