JFL Alarmes LZ-530 SF User manual

www.jfl.com.br
USER
MANUAL
LZ-530 SF
Congratulations,
You have ust acquired a product with JFL Alarmes quality, produced in Brazil
with the highest manufacturing technology. This manual presents the main
functions and characteristics of the equipment.

www.jfl.com.br
ÍNDICE
1 INTRODUCTION.......................................................................................................................................................................3
1.1 OVERALL CHARACTERISTICS........................................................................................................................................3
2 MAIN COMPONENTS..............................................................................................................................................................4
3 INSTALLATION........................................................................................................................................................................4
4 DETECTION RANGE................................................................................................................................................................5
5 PRECAUTIONS/RECOMMENDATIONS.................................................................................................................................6

www.jfl.com.br
1INTRODUCTION
The LZ-530 SF is a motion detection sensor that has low current consumption,
being managed by a micro-controlled circuit that digitally analyzes the signal of
the double-element pyroelectric sensor. This digital treatment uses the
information of amplitude, width, and polarity of the signal, besides the repetition
interval, to ascertain the real intrusion and thus avoid unwanted triggerings. It
uses a special Pet Immunity Fresnel lens, which prevents the detection of small
animals with up to 20 Kg.
1.1 OVERALL CHARACTERISTICS
Frequency: 443.92 MHz;
Transmission range: 200 meters without obstacles;
Maximum detection/angle: 12 meters / 115º;
Sensor: One double-element pyroelectric sensor;
Stabilization time: approximately 30 seconds;
Interval between detections: 2 minutes;
Sensitivity: Three levels of detection sensitivity (minimum, medium, maximum);
Number of zones: 4;
Supply voltage: 3V CR123A lithium battery;
Standby consumption: 4 uA;
Triggered consumption (trigger): 23 mA;
Approximate weight: 100 grams;
Dimensions: 10.5 x 5.6 x 4.5 mm;
Lens: Special Milky PET IMMUNITY 20 kg;
Indication: This sensor must be installed in closed environments.
3

www.jfl.com.br
2 MAIN COMPONENTS
Figure 1 shows the sensor open and its main components:
Figure 1
1) SENSITIVITY switch of the sensor:
1- maximum detection sensitivity.
2- medium detection sensitivity.
3- minimum detection sensitivity.
2) TEST switch: To test the sensor and program it at the central unit.
3) ZONE switch: Selection of zones 1, 2, 3, or 4.
4) TRIGGER LED (RED): When on, indicates that the sensor is triggered and
transmitting. Two flashes at the end of the trigger indicate that the battery
needs to be replaced. Flashing alternately indicates that the sensor is
stabilizing.
5)BOOT connector: Firmware update connector.
6) SENSOR: Pyroelectric sensor (never touch).
7) ANTENNA: Hopping Code data transmission at the 433.92 MHz frequency (do
not alter the position or format of the component).
8) Battery: 3V CR123 Lithium.
3INSTALLATION
The LZ-530 SF sensor may be programmed in all the JFL central units and
receivers that work at the 433.92 MHz frequency in the Hopping Code system.
4

www.jfl.com.br
Install the sensor at a minimum height of 2.10 meters and a maximum height
of 2.4 meters in the vertical position without the use of articulators (vertical
inclination impairs the PET function).
Ad ust the Zone switch (1, 2, 3, or 4) according to the central unit or receiver
that will be programmed.
Ad ust the sensor sensitivity switch (MAXIMUM, MEDIUM, or MINIMUM).
Connect the 3V CR123 lithium battery and wait until the Trigger LED (Red)
stops flashing. This is a procedure for stabilizing the circuit and lasts
approximately 30 seconds.
Press and release the LEARN button of the central unit or receiver; ust after,
press and hold the TEST button of the LZ-530 SF sensor. With this, it will be
programmed.
With the front lid closed, walk slowly in front of the sensor observing the
trigger (the Trigger LED turns on for 3 seconds) in the entire area you wish to
protect. If necessary, ad ust the sensitivity and the positioning of the sensor.
In the first 10 minutes after connecting the battery, the sensor ignores the 2-
minute standby time, i.e., it remains detecting movement to facilitate the
sensor installation.
If more time is necessary, remove the battery and connect it again.
Obs: For better detection, it is advisable to install the sensor in a way that the
path of the intruder is transversal to the sensor beams.
4 DETECTION RANGE
Figures 2 and 3 below show the detection range of the pyroelectric element,
seen from the side and above.
Figure 2
5

www.jfl.com.br
Figure 3
5 PRECAUTIONS/RECOMMENDATIONS
Follow the instructions below to avoid unwanted triggerings.
Do not install the detector
pointed towards a
staircase/stairway on which a
pet could access.
DO NOT install the sensor
directed towards reflective
surfaces, infrared light sources, or
close to ob ects that cause abrupt
temperature changes such as
windows, fans, or heaters.
6

www.jfl.com.br
DO NOT place ob ects or
furniture with heights over 0.8 m
that a pet may escalate (for
example, a cat and a sofa).
DO NOT install the sensor in open areas
VERIFY the distance between the sensor
and the central alarm unit.
AVOID installing the sensor on
metallic surfaces, close to
radiofrequency equipment, or in
locations with many concrete walls
and slabs. This reduces the
communication range with the central
alarm unit.
7

www.jfl.com.br
8
WARRANTY
JFL Equipamentos Eletrônicos Indústria e Comércio Ltda warrants this device for a period of 1
(one) year from the data of purchase, against manufacturing defects that prevent its operation
within the specified technical characteristics of the product. During the warranty period, JFL
will repair (or replace, at its sole discretion), any defective components.
The warranty excludes defects caused by:
Installation outside the technical standard specified in this manual;
Improper use;
Equipment violation;
Atmospheric and accidental phenomena..
The visit of a technical person to a different location will depend on the express authorization of
the client, who will bear the expenses resulting from the trip, or the device will be returned to the
selling company for repair.
JFL EQUIPAMENTOS ELETRÔNICOS IND. COM. LTDA
Rua João Mota, 471 - Jardim das Palmeiras
CEP 37.540-000 - Santa Rita do Sapucaí / MG
Fone: (35) 3473-3550
www. fl.com.br
LZ-530 SF REV.:01 30/07/2020
ECR-18 cloud, ECR-18i cloud e ECR-18 lite rev. 00 04/05/2018