Jolly Q-4 Wash User manual

USER MANUAL
4
4


Table of content
1.Open-Package guidelines........................................................... .1
1.1Package............................................................................. ...1
2.Safety instructions................................................................... ...1
3.Operating determination....................................................... ......3
4.Rigging the fixture................................................................. ......4
4.1 Mounting.......................................................................... .......4
5.
6.
7.
7.1
7.2
7.3
8.DMX protocol........................................................................... ..12
9.Maintance and cleaning..................................................... ........17
10.Electric equipment specification........................................ .......17
10.1 Electrical paramters.......................................................... ..17
10.2
10.3
............
............
............
............
............
............
4.2Installing the Clamps............................................................................4
4.3 Power supply connection and cut off...................................................5
4.4 Power Connection...............................................................................6
4.5 DMX-512 connection/connection between fixtures.............................6
............
............
............
............
............
............
............
............
............
............
....................................................................17
Channel Characteristics...................................................................17
10.4 Menu Function.................................................................................18
10.5 light table........................................................................................18
11.Electronic drawing.................................................................................19
Description of the device........................................................... ...7
Dimension.................................................................................. ..8
Display control......................................................................... ....9
Navigation in the Menu......................................................... ...9
Display Operation................................................................. ...9
Menu list................................................................................. 11
Weight and dimensions

Congratulations on choosing our products! Please carefully read this instruction manual in its
entirety and keep it well for using reference. This manual contained about the installation and
the relative using information of this products. Plese refere this manual's relative instruction
when using this equipment.

- 1 -
2.Safety instructions
1.Open-Package guidelines
1.1Package
Unpacking the fixture
1.Open the flight case cover
2.With one person on each side, lift the fixture out of the flight case.
3.Unlock pan and tilt before operating fixture
Packing the fixture
1.Disconnect the fixture from power and allow it to cool.
2.lock arms as figure. (
3.Place the fix ture in the bottom of the flight case, and cover the case without forcing.
- Fig.1 PAN Mechanism Lock and Release (every 90°) - Fig.2)
This equipment is made of new style,high intensity plastic.It fully shows the modem times light charac
teristic with beauty struture. And it is made accord to CE standard. Fully agree with the internation
512 agreement.
teris-
tic with
standard of DMX
1.Signal cable-1PC 2.Safty cable-1PC
3.User Manval-1PC 4.Omega holder-2PCS
5.Power cable-1PC 5.Service card-1PC
When receive the product,please be careful to take and put,check if the product has damage or not be-
Arm lock
Level transportation lock
90°
90°
90°
90°
Fig.2
LOCKED
Aviation box
UNLOCKED
Fig.1
cause of transportation, and check the following parts:
This device has been shipped with our premises in absolutely perfect condition. In order to maintain this
ensure a safe operation ,it is absolutely necessary for the user to follow the safety instruc -
notes written in this manual.
Important:
The manufacturer will not accept liability for any resulting damages caused by the nonobservance of this
manual or any unauthorized modification to the device.
Please consider that damages caused by manual modifications to the device are not subject to warranty.
condition and to ti
ons and warning
Every person involvd with installation and maintenance of this device to:
-Be qualilfied
-Follow the instructions of this manual.
Note: to prevent the
lamp damaged, focusing
lens must return, can be
placed in the box.

Never let the power-cord come into contact with other cables! Handle the power cord and all connections
with particular caution!
Make sure that the available voltage is not higher than stated on the rearpanel.
Always plug in the power plug least. Make suer that the power-switch is set to off-position before you con
ections with themains with particular caution!
Make sure that the power-cord is never crimped or damaged by sharp edges.Check the decice and the p-
ower-cord from time to time.
Always disconnect from the mains, when the device is not in use or before cleaning it.
Only handle the power-cord by the plug,Never pull out the plug by tugging the powercord.
This device falls under protection class I.Therefore it is essential to connect the yellow/green conductor
to earth.
The electric connection,repairs and servicing must be carried out by a qualified employee.
Do not connect this device to a dimmer pack.
Do not switch the fixture on and off in short intervals as this would reduce the lamp’s life.
Do not touch the device’s housing bare hands during its operation(housing becomes hot)!
For replacement use lamps and fuses of same type and rating only.
t 90
c°C
IP20
t 40
a°C
Risk Gr oup 2
Accor ding to
En624 71
Eye damage!
Avoid looking directly into the light source(meant especially for epileptics)!
Minimum distance of illuminated objects
0.20 metres from the lens of the projector.
Maximum ambient temperature
Do not operate the fixture if the ambient temperatuer(Ta) exceeds 40°C (104°F).
Temperature of the external surface
The maximum temperature that can be reached on the external surface of the fitting,in a ther-
mally steadystate,is 90°C (194°F).
IP20 protection rating
The fitting is protected against penetration by solid of over 12mm (0.47”) in diameter (first
digit 2), but not against dripping water,rain,splashes or jets of water (second digit 0).
Indoor use only
Not suitable for household illumination
Photobiological Safety
CAUTION.Possibly hazardous optical radiation emitted from this product.Do not stare at
operating lamp.May be harmful to the eyes.
Light collimation system
This product contains internal light collimation system.Avoid intense light from any angle.
The products to which this manual refers comply with the European Directives purs-
uant to:
•2006/95/EC - Safety of electrical equipment supplied at low voltage (LVD)
•2004/108/EC - Electromagnetic Compatibility (EMC)
•2011/65/EU - Restriction of the use of certain hazardous substances (RoHS)
•2009/125/EC - EcoDesign requirements for Energy-related Products (ErP)
Protection against electrical shock
Connection must be made to a power supply system fitted with efficient earthing (Class I app-
liance according to standard EN 60598-1) .It is, moreover, recommended to protect the supply
lines of the projectors from indirect contact and/orshorting to earth by using appropriately
sized residual current devices.
The projector needs to be positioned so that the objects hit by the beam of light are at least
- 2 -
0.2

Disposing
This product is supplied in compliance with European Directive 2012/19/EU-Waste Electrical
and Electronic Equipment (WEEE) .To preserve the environment please dispose/recycde this
product at the end of its life according to the local regulation.
Battery
This product contains a rechargeable lead-acid or lithium iron tetraphosphate battery. To pre-
serve the environment,please dispose the battery at the end of its life according to the regul-
ation in force.
This device is a moving-head for creating decorative effects and was designed for indoor use only.
If the device ha been exposed to drastic temperature fluctuation(e.g.after transportation).do not weitch it
on immediately.The arising condensation water might damage your device,Leave the device switched off
until it has reached room temperature.
Never run the device without lamp!
Do not shake the device,Avoid brute force when installing or operating the device.
Never life the fixture by holding it at the projectorhead, as the mechanics may be damaged. Always hold
the fixture at the transport handles.
When choosing the installation-spot,please make sure that the device is not exposed to heat,moisture or
dust.There should not be any cables lying around.You endanger your own and the safety of others!
The minimum distance between light output and the illuminated surface must be more than 0.2 meters.
Make sure that the area below the installation place is blocked when rigging,derigging or servicing the fi-
xture.
Always fix the fixture with an appropriate safety rope, Fix the safety rope at the correct holes only.
Operate the fixture after having checked that the housing is firmly closed and all screws are tightly faste-
nd.
The lamp must never be ignited if the objective-lens or any housing-cover is open, as discharge lamps
may explose and emit a hign ultraviolet radiat, which may cause burns.
The maximum ambient temperature 40°C must never be exceeded.
Operate the device only after having familiarized with its functions. Do not permit operation by persons
not qualified for operating the device. Most damages are the result of unprofessional operation!
Please use the original packaging if the device is to be transported.
Please consider that unauthorized modifications on the device are forbidden due to safety reasonsl.
If this device will be operated in any way different to the one described in this manual, the product may
suffer damages and the guarantee becomes void.Furthermore, any other operation may lead to dangers
like short-circuit,burns, electric shict,burns due to ultraviolet radiation,lamp explosion,crash etc.
3.Operating determinations
- 3 -

4.1 Mounting
For the various mounting positions of the FIXTURE(standing on the floor, sideways or hanging different
accessories kits are available.
Through this a safe and firm installation is assured.
You’ll find special connectors on the bottom side of the system which are put to use here.
4.2 Installing the Clamps
Please consider the respective national norm s during the Installation!The installation must only be car-
ried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the wei-
ght for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g.an appropriate catch
net.This secondary safety attachment must be constructed in a way that no part of the installation can
fall if the main attachment fails.
When servicing the fixture staying in the area below the installation place,on bridges,under high working
places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by
an expert before taking into operation for the first time and after changes before taking into operation an-
other time.
The operator has to make sure that safety-relating and machine-technical installations are approved by
an expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by
a skilled person once a year.
The projector should be installed outside areas where persons m ay walk by or be seated.
Important!Overhead rigging requires extensive expering CE,including (but not limited to)calculating
working load limits, installation material being used, and periodic safety inspection of all installation ma-
terial and the projector. If you lack these qualifications, do not attempt the installation yourself, but inste-
ad use a professional structural rigger. Improper installation can result in bodilyinjury and or damage to
property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing system s have
to be used. The projector must never be fixed swinging freely in the room .
Caution Projectors may cause severe injuries when crashing down! If you have doubts concerning the
safety of a possible installation, do not install the projector!
Before rigging make sure that the installation area can hold a minim um point load of 10 times the
projector s weight.
4.Rigging the fixture
Pay attention to the regulations of CE.
Installation by qualified staff to complete.
- 4 -

- 5 -
The projector can be placed directly on the stage floor or rigged in any orientation on atruss without alte-
ring its operation characteristics.
For overhead use,always install a safety-rope that can hold at least 10 times the weight of the fixture.You
must only use safety-ropes with screw on carabines.Pull the safety-rope through the two apertures on the
bottom of the base and over the trussing system etc.
1
2
3
4mounting plate
secure chain
omega holder
Lock catch
Warning: it is necessary to make sure that
the installation location is perfectly appropriate,
and the installation location is safe and reliable.
0.8
1
2
12
3
4.3 Power supply connection and cut off
Connect the light source to the main power source with the plug of the power cord, or cut off the power
supply:
Connection: according to procedures, the power
plug and socket is inserted into the groove one one
alignment,rotation.
Cut off:according to procedures,press the button
on the rotating plug,pull out.
23
41
1
11
0.8

- 6 -
2 1
3
2 1
3
5 1
4 2
3
5 1
4 2
3
5 1
4 2
3
1:Ground
2:Signal(-)
3:Signal(+)
1:Ground
2:Signal(-)
3:Signal(+)
4:N.A.
5:N.A.
2 1
3
5 1
4 2
3
4.5 DMX-512 connection/connection between fixtures
Only use stereo shieded cable and 3-pin XLR-plugs and connectors in order to connect.
Caution
At the last fixture,the DMX-cable has to be terminated with a terminatou. solder a 120 resistor between
signal(-) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
DMX iutput
3-pin XLR socket
DMX iutput
5-pin XLR socket
DMX output
3-pin XLR socket
DMX output
5-pin XLR socket
4.4 Power Connection
mains with the enclosed power cable and plug.
If you wish to change the power supply settings, see the chapter appendix Connect the fixture to the
L
N
CABLE(EU) CABLE(US) Pin
Brown Black Live
Yellow/Green Green Earth
Light blue White Neutral
INTERNATIONAL
Standard edition
Online edition
Warning: please verify the power of the power
supply equipment prior to the connection! Earth wire
must be grounded!
DMX512 DMX512

- 7 -
5.Description of the device
DMX Terminator Diagram
-For installations where the DMX cable has to run a long distance or
is In an electrically noisy environment it is recommended to use a
DMX terminator. This help in preventing corruption of the signal by
electrical noise. The DMX terminato r is simply an XLR plug witha
120 resistor connected between pins 2 and pins3, which is then
plugged into a the output XLR socket of the last ifxture in the chain.
Ω
1
2
3
120Ω
PIN2 PIN3
Head
Tilt °,
210 Fixture could auto
reset.
3.
Arm
Pan °,540 Fixture could auto
reset.
Base
2.
1.
18.WDMX wire
BACK PANEL
4.5-pin XLR female
5.3-pin XLR female
6.Power-in
7. Power switch
8.Main Fuse
9.3-pin XLR male
10.5-pin XLR male
11.Network interface
CINTROL PANEL
12.DOWN button
13.Status indicator lamp
14.ENTER button
15.Touch screen(LCD display)
16.MODE button
17.UP button
18.WDMX Wire
Standard edition
Online edition
17
13 15 16
14
10 9 8
6
5
4
7
7
10 8
11
411
12
6

- 8 -
6.Dimension
ZOOM IN
428.5
473
ZOOM OUT
ZOOM IN
190.5
ZOOM OUT
235
493.5
390
390
286.5
286.5
250
381

7.Display control
7.1 Navigation in the Menu
7.2 Display Operation
Using the buttons or touch screen, and this can be simply and easily set the address code and
code.
functions
If you view or modify the lighting feature set, then press ENTER button, the display will enter the menu
interface. Both there is sub menu corresponding to the functional operation of the main menu. Each of the
menus is representative of the specific features of the lamp. The specific contents shows as the table
menu below.
Set or browse lighting function, press UP or DOWN button.
Press ENTER to save your changes or enter the submenu.Press the UP or DOWN can change the nume-
rical (increase or decrease in value).
Press the MODE button to return to menu. Set a time 0 to 10 minutes automatically exit menu interface
and close the screen.
Put through power supply, open the power switch of lamps and lanterns, display show the company
website. According to the main interface, as shown in figure:
In the main interface, press "MODE" button to view the software version, press the "UP" "DOWN" can m-
odify the DMX address.
If the screen " " icon is green,said DMX signal connection is normal, this state can be used to check th-
elamps and lanterns and connection between the control table is normal.
LOGO
- 9 -
Menu interface
E12:Bus l E r r1 01
Mode EnterUp Down
001
1
001-019Se t ti n gs
1
Main interface
A
0001
1
00 1-0 19
Se tt in gs
1
Dmx Address
0 10
Mode EnterUp Down
CH-001: 000.0% 000
CH-002:Red Fine 000.0% 000
CH-003:Green 000.0% 000
CH-004:Green Fine 000.0% 000
CH-005:Blue 000.0% 000
CH-006:Blue Fine 000.0% 000
CH-007:White 000.0% 000
CH-008:White Fine 000.0% 000
CH-009:Liner CTO 000.0% 000
CH-010:Macro Colour 000.0% 000
Red
Mode EnterUp Down
Set Up
Inforamtion
Personality
Manual Control
Advanced
Mode EnterUp Down
Channel Mode
STANDARD
SHAPES
EXTENDED
Mode EnterUp DownMode EnterUp Down
Can vi ew the company LOGO ,web
site , hardware, softw are version, date.
Dmx Input
Wired Input
Wireless Input
Wireless In/
XLR out
Dmx Input
Mode EnterUp Down
Press this area for 2 seconds
to modif y the DMX address.

- 10 -
Click on the main interface of the icon, numerical to view view Settings related information of lamps and
lanterns.Symbols such as the main interface appear “ “,the following error message indicates that there
might be a lamps and lanterns,can click to view and control information content to modify the lamps and
lanterns.
This lamp can be set to turn off the automatic flip screen function, touch this " “ icon can be manually
flip screen.
CODE
ERRO INFO CHECK MEASURMENT NOTE
E02 Program Err 1 Check the welding of Chip
E04 MBDInit Error Check the communication signal 485& 485 chip &
E05 BD1Init Error
E06 BD2Init Error
E12 Bus1 Error Check main cable ABAB(485) chip
E16 MFpga Error
E17 BD1 BUS
E18 BD2 BUS
E21 Pan FB. Error
E23 Tilt FB. Error
E22 Pan Zero Error
E24 Tilt Zero Error
E46 H.Fan Error Check the fan of head
RESET
ERROR
Check main cable ABAB(485) chip
Check the communication signal& welding of
communication chip
Check the light coupling line, optical coupling switch and
a plate of the relative position measurement
Check cable of sensor, distance and location of ,magnets
and sensor

7.3 Menu list
- 11 -
Remark
DMX Address DMX Address 001~XXX
STANDARD 1~19
SHAPES 1~30
EXTENDED 1~31
Fixture Id 0001~XXXX Lamps address
XXXXX h XX m Total working hours
Reset LED Time Reset Lamp Time
Error List Error details
BOARD 1: XX.XX%
BOARD 2: XX.XX%
DMX Values DMX Values
Fans Monitor Fans Values
Pan Reverse ON/OFF Pan Reverse(defaul OFF)
Tilt Reverse ON/OFF Tilt Reverse(defaul OFF)
Feedback ON/OFF Pan/Tilt Auto Switch(defaul ON)
Wired Input Wired Input(defaul)
Wireless Input Wireless Input
Wireless In/XLR out Wireless In/XLR out
Brightness Brightness
Screen Time out 0-10m Screen Time out(defaul 2m)
Touch Screen ON/OFF Touch Screen(defaul ON)
Auto Screen ON/OFF Auto Screen(defaul ON)
Auto
High
English English
Simplified Chinese Simplified Chinese
Reset ALL
Reset Pan/Tilt
Reset Other
Channel Chanel Testing
Calibration Chanel Adgusting
Factory Default Reset to orignal parameters
Touch Calibration Touch screen adjusting
Reset
Manusl ControlAdvanced Personality
default Mode1
DiagnosisDiagnosis
Channel Mode
Fixture Times
Screen
Fan Mode
Language
Information
Pan/Tilt
Dmx Input

8.DMX protocol
- 12 -
Mode1 Mode 2 Mode3 Fade Type Function Dmx
Value
1 1 1 Red Black→Red 0-100% 0-255
2 2 2 Red fine Red fine 0-255
3 3 3 Green Black→Green 0-100% 0-255
4 4 4 Green fine Green fine 0-255
5 5 5 Blue Black→Blue 0-100% 0-255
6 6 6 Blue fine Blue fine 0-255
7 7 7 White Black→White 0-100% 0-255
8 8 8 White fine White fine 0-255
UNUSED RANGE 0-9
8000K 10
8000K→7000K 10-54
7000K→6000K 54-99
6000K→5600K 99-117
5600K→5000K 117-144
5000K→4000K 144-188
4000K→3200K 188-224
3200K→2500K 224-255
Macro color OFF 0-9
Red 10
Green 11
Blue 12
Cyan 13
Yellow 14
Magenta 15
White 7000 K 16
White 3700 K 17
White 5000 K 18
Black 19
Medium Yellow 20-22
Straw Tint 23-26
Surprise Peach 27-28
Fire 29
Medium Amber 30
Gold Amber 31
Dark Amber 32-34
Sunrise Red 35-44
Light Pink 45
Medium Pink 46-48
Pink Carnation 49-61
Light Lavender 62-67
Lavender 68-77
Sky Blue 78-88
Just Blue 89-99
Dark yellow green 100-109
Macro
colour
101010
Note: If CTO channel is active, the WHITE channel is disabled.
9 9 9 Linear CTO

- 13 -
Mode1 Mode 2 Mode3 Fade Type Function Dmx
Value
Spring Yellow 110-111
Light Amber 112
Straw 113
Deep Amber 114
Orange 115-116
Light Rose 117
English Rose 118
Light Salmon 119
Middle Rose 120
Dark Pink 121-122
Magenta 123-124
Peacock Blue 125
Med Blu Green 126
Steel Blue 127
Light Blue 128
Dark Blue 129-130
Leaf Green 131-133
Dark Green 134-135
Mauve 136-137
Bright Pink 138-141
Medium Blue 142-144
Deep Golden Amber 145
Pale Lavender 146
Special lavender 147-148
Primary Green 149-150
Bright Blue 151-156
Apricot 157-161
Pale Gold 162-167
Deep Orange 168-171
Bastard Amber 172-173
Flame Red 174
Daylight Blue 175-178
Lilac Tint 179
Deep lavender 180-183
Dark Steel Blue 184-190
Congo Blue 191-206
Alice Blue 207
Dirty White 208
White 209-255
CLOSED 0-3
STROBE SLOW→FAST(1→25 flash/sec) 4-103
OPEN 104-107
PULSATION SLOW→FAST(0.5-25 flash/sec) 108-207
OPEN 208-212
RANDOM SLOW STROBE 213-225
RANDOM MEDIUM STROBE 226-238
RANDOM FAST STROBE 239-251
OPEN 252-255
10 10 10 Macro
colour
11 11 11 Strobe

- 14 -
12 12 12 Dimmer
Dimmer 0-100% 0-255
13 13 13 Dimmer
Fine Dimmer Fine 0-255
14 14 14 Pan Pan 0-255
15 15 15 Pan Fine Pan Fine 0-255
16 16 16 Tilt Tilt 0-255
17 17 17 Tilt Fine Tilt Fine 0-255
Function off – rearmed 0-11
Pan Tilt Fast (Default) 12-24
Pan Tilt Normal 25-37
Dimmer Curve 1 38-42
Dimmer Curve 2 43-47
Dimmer Curve 3 48-52
Dimmer Curve 4 53-57
RGBW Gamma curve 1 – gamma = 1.0 58-62
RGBW Gamma curve 2 – gamma = 1.5 63-67
RGBW Gamma curve 3 – gamma = 2.0 68-72
Halogen Lamp Simulation OFF (Default) 73-77
Halogen Lamp Simulation,type 1(750 W)Linear CTO @ 0 bit 78-82
Halogen Lamp Simulation,type 2(1000 W)Linear CTO @0 bit 83-87
Halogen Lamp Simulation,type 3(1200 W)Linear CTO @ 0 bit 88-92
Halogen Lamp Simulation, type 4(2000 W)Linear CTO @0 bit 93-97
Halogen Lamp Simulation,type 5(2500 W)Linear CTO @0 bit 98-102
PAN / TILT RESET 103-107
ZOOM RESET 108-112
COMPLETE RESET 113-117
Reserved 118-255
19 19 19 Zoom ZOOM NARROW BEAM→WIDE BEAM 0-255
UNUSED RANGE 0-7
Ring1 8
Ring2 9
Ring3 10
Ring1+Ring2 11
Ring1+Ring3 12
Ring2+Ring3 13
Single ring 14
Single ring & fade 15
Filled rings 16
Filled rings & fade 17
Ring Opening(Closing) 18
Ring Opening(Closing) & fade 19
Ring Opening(Closing) Filled 20
Ring Opening(Closing) Filled & fade 21
Random Ring 22
Random Ring & fade 23
UNUSED RANGE 24-255
Function
Shape
Selection
1818
The functions are actived passing through the “unused range” and
staying 5 seconds
activated passing throug the unused rangeand staying 5 seconds
18
20
Mode1 Mode 2 Mode3 Fade Type Function Dmx
Value

- 15 -
Mode1 Mode 2 Mode3 Fade Type Function Dmx
Value
stop 0-63
max to min speed,Closing effect 64-158
STOP 159-160
min to max speed,Opening effect 161-255
22 Shape R Shape R 0-255
23 Shape G Shape G 0-255
24 Shape B Shape B 0-255
25 Shape W Shape W 0-255
26 Shape
Dimmer Shape Dimmer 0-100% 0-255
27 Backgroun
d Dimmer Background Dimmer 0-100% 0-255
Shutter closed 0-3
Strobe-effect from slow to fast 4-103
Shutter open 104-107
pulse in sequences from slow to fast 108-207
Shutter open 208-212
Random strobe-effect from slow to fast 213-251
Shutter open 252-255
Shutter closed 0-3
Strobe-effect from slow to fast 4-103
Shutter open 104-107
pulse in sequences from slow to fast 108-207
Shutter open 208-212
Random strobe-effect from slow to fast 213-251
Shutter open 252-255
wash 0-7
Ring1 8
Ring2 9
Ring3 10
Ring1+Ring2 11
Ring1+Ring3 12
Ring2+Ring3 13
UNUSED RANGE 14-255
20 Red LED 1 Red 0-100% 0-255
21 Green LED 1 Green 0-100% 0-255
22 Blue LED 1 Blue 0-100% 0-255
23 White LED 1 White 0-100% 0-255
24 Red LED 2 Red 0-100% 0-255
25 Green LED 2 Green 0-100% 0-255
26 Blue LED 2 Blue 0-100% 0-255
27 White LED 2 White 0-100% 0-255
28 Red LED 3 Red 0-100% 0-255
29 Green LED 3 Green 0-100% 0-255
30 Blue LED 3 Blue 0-100% 0-255
31 White LED 3 White 0-100% 0-255
Foreground
Strobe
Backgroun
d Select
28
30
29
21
Backgroun
d Strobe
Shape
Speed

- 16 -
LED reference number for pixel mapping
TILT: channel 16 @ 200 bit
1
LED
2
3
45
6
7
9
8
10
11
12
13 14
15
16
17
18
19
Function
The functions are actived passing through the “unused range” and staying 5 seconds.
Activated passing throug the unused rangeand staying 5 seconds.
Function Dmx Value
Function off -rearmed 0-11
Pan Tilt Fast (Default) 12-24
Pan Tilt Normal 25-37
Dimmer Curve 1 38-42
Dimmer Curve 2 43-47
Dimmer Curve 3 48-52
Dimmer Curve 4 53-57
RGBW Gamma curve 1 -gamma = 1.0 58-62
RGBW Gamma curve 2 -gamma = 1.5 63-67
RGBW Gamma curve 3 -gamma = 2.0 68-72
Halogen Lamp Simulation OFF (Default) 73-77
Halogen Lamp Simulation,type 1(750 W)Linear CTO @ 0 bit 78-82
Halogen Lamp Simulation,type 2(1000 W)Linear CTO @0 bit 83-87
Halogen Lamp Simulation,type 3(1200 W)Linear CTO @ 0 bit 88-92
Halogen Lamp Simulation, type 4(2000 W)Linear CTO @0 bit 93-97
Halogen Lamp Simulation,type 5(2500 W)Linear CTO @0 bit 98-102
Function Dmx Value
PAN / TILT RESET 103-107
ZOOM RESET 108-112
COMPLETE RESET 113-117
Reserved 118-255
Table of contents
Other Jolly Light Fixture manuals
Popular Light Fixture manuals by other brands

EXC
EXC ECOLOR EC-C8240N quick start guide

Pentair
Pentair 560003 installation instructions

Blizzard Lighting
Blizzard Lighting Wink manual

Christie
Christie High Performance Xenon Lamp CDXL product manual

Chauvet Professional
Chauvet Professional MAVERICK FORCE S PROFILE user manual

Briteq
Briteq BT-Tracker Operation manual