-iii -
Operation of Duty Officer
The input of a password is required to carry out change of the operation mode or various time, and a backup officer's
setting variation.
- Press a key, display a menu screen and choose [SET VALUE].
- Since a password input screen is displayed, enter 4 figures of passwords by up and down arrow key, and press a
key.
(As for the password, "0000" is set up as an initial value.)
- Since a function selection screen is displayed, choose each function.
- A key is pressed, display a menu screen, choose [SET VALUE], and enter a password.
- Choose [ALARM TIME] in a function selection screen.
Since a dormant period is displayed on [INTERVAL], it changes by up and down arrow key. Since the third stage
remote audible alarm transfer waiting time is displayed on [3RD STAGE], it changes by up and down arrow key.
Since bridge alarm transfer waiting time is displayed on [BRIDGE], it changes by up and down arrow key.
Also it is set up when all press a key.
- After a change is over, push a key. It returns to a countdown screen.
- A key is pressed, display a menu screen, choose [SET VALUE], and enter a password.
- Choose [OPERATION MODE] in a function selection screen.
Choose the operation mode to change and push . The selected mode changes to the display of [ON].
- After a change is over, push a key. It returns to a countdown screen.
Operate in “MANUAL ON” mode normally.
When power on, the system starts with "MANUAL ON" mode. The operation mode is not memorized.
- A key is pressed, display a menu screen, choose [SET VALUE], and enter a password.
- Choose [BACKUP OFFICER] in a function selection screen.
Choose the officer who wants to change. Press a key. When the up and down arrow key is pressed,
ON/OFF will change. It is set up when a key is pressed.
The backup officer who is not connected is not displayed.
It is necessary to make at least one person’s officer backup.
- After a change is over, push a key. It returns to a countdown screen.
- Press A key, and a menu screen is displayed. When choosing [HISTORY], an alarm history is displayed.
- Six histories are saved at the maximum and displayed on new order.
Change the operation mode
Change the backup officer