Jumbl JUBTPASO1 User manual

Transfer Pump
User Guide
JUBTPASO1
Thank you for purchasing the Jumbl®Transfer Pump. This User Guide is intended to provide you with
guidelines to ensure that operation of this product is safe and does not pose risk to the user. Any use
that does not conform to the guidelines described in this User Guide may void the limited warranty.
Please read all directions before using the product and retain this guide for reference. This product
is intended for domestic use only. It is not intended for commercial use.
This product is covered by a limited one-year warranty. Coverage is subject to limits and exclusions.
See warranty for details.
SAFETY PRECAUTIONS
• Don’t use this pump until you thoroughly read and understand all of the operation instructions and
warnings. Deviating from these instructions could result in re, explosions, property damage, and/
or operator injury. Don’t try to operate this device without reading the instructions.
• Make sure to familiarize yourself with the appliance itself before using it.
• Before using this appliance, check all the parts to make sure they function properly, and make sure
no components have been damaged.
• Keep out of the reach of children.
• Always keep away from heat or ame, and avoid prolonged exposure to sunlight.
• Don’t use a leaking, damaged, or malfunctioning pump. If it’s ever damaged, do not use it, and
immediately contact the authorized service center for assistance.
• Pumps that are improperly operated, maintained, or repaired are dangerous! Improper use, service
repair, or modication of the pump could result in damage to the product, property damage, or
personal injury to the operator.
• Do not inhale gas, fumes, vapor, or spray of fuel, and avoid contact with skin and eyes. If inhaled,
immediately move the affected person to fresh air. For skin contact, ush with lots of water. In case
of eye contact, rinse immediately with plenty of water and then seek medical advice.
• Storage tanks should be securely anchored to prevent shifting or tipping when full or empty.
• Do not use without liquid. Take care to make sure that liquid does not run out while pump is in operation.
• Do not use with thinner or other solvents.
• Do not use with corrosive liquids.
• Before using pump, make sure that any hot surfaces have cooled down.
• Do not position or store the pump upside-down after use.
• Remove batteries when not in use.
• The pump is not intended for use with drinking water.
Package Contents
• Transfer pump
• User guide
DANGER: FUEL IS EXTREMELY FLAMMABLE. DO NOT SMOKE OR USE AN OPEN
FLAME NEAR THE PUMP.
1

Features
• Battery operated for portability
• Auto-Stop feature prevents overow
• Transfers liquids at a rate of 2.3 gallons per minute
• No seal required
• For use with gasoline, kerosene, diesel, light oils, and non-potable water
• Great for emergency generators, yard equipment, and utility machinery
Product Overview
How to Assemble Your Pump
1. Install 2 new D batteries, making sure the polarity on
the batteries matches the polarity indicators
embossed just above the threaded area of the
battery casing. Do not install different types of
batteries or partially-charged batteries.
2. Screw the sides of the battery casing back together,
using a clockwise motion.
3. Ensure that the discharge hose is rmly seated
before use.
How to Use Your Pump
1. Check the unit over before each use to make sure
there are no holes in the tubes or hoses.
2. Immerse the intake tube into the supply tank from
which you wish to transfer uid.
3. Place the nozzle of the discharge hose into the tank
to which you wish to transfer uid, and use the
included clip to hold it in place.
4. Turn the power switch on to begin transferring liquid.
5. Pump will stop automatically when the receiving tank is full.
You can also stop the pump manually by turning the power
switch off.
6. If you wish to transfer liquid from a new container, you must
turn the power switch off, immerse the intake tube into the
new container, and then restart the pump.
2
Intake tube
Battery casing/
pump unit
Power switch
Discharge hose with clip and nozzle
BATTERIES
BATTERY CASE
TURN COUNTER CLOCKWISE TO OPEN
ON DISCHARGE
HOSE
INTAKE
TUBE
RECEIVING
TANK
SUPPLY
TANK
OFF

Specications
Transfer rate: 2.3 gallons/minute
Power source: 2 D batteries (not included)
Rated voltage: DC 3V
Operational voltage: DC 1.7V – 3.3V
Operating temperature range: 41˚F - 113˚F
Compatible Liquids: Gasoline, kerosene, diesel, light oils, non-potable water, chemical insecticides,
soaps, detergents, deodorants, mild acids, antifreeze
3
LIMITED WARRANTY ON JUMBL®TRANSFER PUMP
THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER
RIGHTS, WHICH VARY FROM STATE TO STATE.
WE WARRANT THAT DURING THE WARRANTY PERIOD, THE PRODUCT WILL BE FREE FROM DEFECTS
IN MATERIALS AND WORKMANSHIP.
LIMITATION OF LIABILITY
TO THE EXTENT NOT PROHIBITED BY LAW, THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER
WARRANTIES, ORAL, WRITTEN, STATUTORY, EXPRESS OR IMPLIED. EXCEPT FOR THE EXPRESS
WARRANTIES CONTAINED IN THIS LIMITED WARRANTY STATEMENT AND TO THE EXTENT NOT
PROHIBITED BY LAW, WE DISCLAIM ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, STATUTORY
OR OTHERWISE, INCLUDING WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. SOME STATES DO NOT ALLOW DISCLAIMERS OF IMPLIED
WARRANTIES, SO THIS DISCLAIMER MAY NOT APPLY TO YOU. TO THE EXTENT SUCH WARRANTIES
CANNOT BE DISCLAIMED UNDER THE LAWS OF YOUR JURISDICTION, WE LIMIT THE DURATION AND
REMEDIES OF SUCH WARRANTIES TO THE DURATION OF THIS EXPRESS LIMITED WARRANTY.
OUR RESPONSIBILITY FOR DEFECTIVE GOODS IS LIMITED TO REPAIR, REPLACEMENT OR REFUND AS
DESCRIBED BELOW IN THIS WARRANTY STATEMENT.
WHO MAY USE THIS WARRANTY? C&A Marketing, Inc. located at 114 Tived Lane East, Edison, NJ
(“we”) extend this limited warranty only to the consumer who originally purchased the product (“you”). It
does not extend to any subsequent owner or other transferee of the product.
WHAT DOES THIS WARRANTY COVER? This limited warranty covers defects in materials and workman-
ship of the Jumbl®Transfer Pump (the “product”) for the Warranty Period as dened below.
WHAT DOES THIS WARRANTY NOT COVER? This limited warranty does not cover any damage due to:
(a) transportation; (b) storage; (c) improper use; (d) failure to follow the product instructions or to
perform any preventive maintenance; (e) modications; (f) unauthorized repair; (g) normal wear and tear;
or (h) external causes such as accidents, abuse, or other actions or events beyond our reasonable
control.
WHAT IS THE PERIOD OF COVERAGE? This limited warranty starts on the date of your purchase and
lasts for one year (the “Warranty Period”). The Warranty Period is not extended if we repair or replace
the product. We may change the availability of this limited warranty at our discretion, but any changes
will not be retroactive.
WHAT ARE YOUR REMEDIES UNDER THIS WARRANTY? With respect to any defective product during
the Warranty Period, we will, at our sole discretion, either: (a) repair or replace such product (or the
defective part) free of charge or (b) refund the purchase price of such product if an exchange unit cannot
be provided.
HOW DO YOU OBTAIN WARRANTY SERVICE? To obtain warranty service, you must contact us at
Merchandise Authorization (“DMA”) number. No warranty service will be provided without a DMA
number and return shipping costs to our facilities shall be assumed by you, the purchaser. Shipping
costs of the replacement unit to you shall be assumed by us.
Get in Touch!
info@itsjumbl.com | 866-849-3049
JUMBL and the JUMBL LOGO are trademarks of C&A IP Holdings, LLC in the US.
All other products, brand names, company names, and logos are trademarks of their respective owners, used merely to identify
their respective products, and are not meant to connote any sponsorship, endorsement or approval.
Distributed by C&A Marketing, Inc., 114 Tived Lane East, Edison, NJ 08837.
C&A Marketing UK LTD, 167 Hermitage Road, Crusader Industrial Estate, London, N4 1LZ, UK
© 2019. C&A IP Holdings, LLC. All Rights Reserved. Made in China.
Table of contents