manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Juniper
  6. •
  7. Amplifier
  8. •
  9. Juniper PTX Series User manual

Juniper PTX Series User manual

Other manuals for PTX Series

2

This manual suits for next models

1

Other Juniper Amplifier manuals

Juniper PTX User manual

Juniper

Juniper PTX User manual

Juniper TCX1000 User manual

Juniper

Juniper TCX1000 User manual

Juniper TCX1000 Installation instructions

Juniper

Juniper TCX1000 Installation instructions

Popular Amplifier manuals by other brands

Magnat Audio EDITION FOUR Owner's manual/warranty document

Magnat Audio

Magnat Audio EDITION FOUR Owner's manual/warranty document

Inter-m PA-2000A Operation manual

Inter-m

Inter-m PA-2000A Operation manual

Yamaha TX6n owner's manual

Yamaha

Yamaha TX6n owner's manual

Peavey TNT 150 user guide

Peavey

Peavey TNT 150 user guide

Bosch LBB 1903/10 Installation and user instructions

Bosch

Bosch LBB 1903/10 Installation and user instructions

Avocent Emerge DA1200D Installer/user guide

Avocent

Avocent Emerge DA1200D Installer/user guide

Redgum RGi35 operating instructions

Redgum

Redgum RGi35 operating instructions

Cambridge Audio AXA25 user manual

Cambridge Audio

Cambridge Audio AXA25 user manual

Alpine MRP-M200 owner's manual

Alpine

Alpine MRP-M200 owner's manual

Technical Pro H1502UrBT user manual

Technical Pro

Technical Pro H1502UrBT user manual

FMS EMGZ307 operating manual

FMS

FMS EMGZ307 operating manual

Racal Instruments 5601 user manual

Racal Instruments

Racal Instruments 5601 user manual

Valcom V-1094A Technical specifications

Valcom

Valcom V-1094A Technical specifications

Cambridge Audio 851D user manual

Cambridge Audio

Cambridge Audio 851D user manual

QSC 3800 Specifications

QSC

QSC 3800 Specifications

NAD C300 owner's manual

NAD

NAD C300 owner's manual

Rotel RMB-1077 owner's manual

Rotel

Rotel RMB-1077 owner's manual

Peavey Monitor 300 Series operating guide

Peavey

Peavey Monitor 300 Series operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Optical Inline Amplifier Quick Start
See the complete PTX Series documentation at
http://www.juniper.net/techpubs/.
To install, connect power to, and configure the Juniper Networks
Optical Inline Amplifier, you need:
zElectrostatic discharge (ESD) grounding strap (not provided).
zFour screws to secure the chassis and mounting brackets to the
rack (not provided).
zScrewdriver appropriate for the rack-mounting screws (not provided).
zTwo power cords with plugs appropriate for your geographical location (provided with
the AC model).
zTwo DC power connectors (provided with the DC model).
zPower cable or cables appropriate for your geographical location available to connect
DC power to the optical ILA (not provided).
zRJ-45 cable and RJ-45 to DB-9 serial port adapter (provided).
zManagement host, such as a PC laptop, with a serial port (not provided).
z(Optional) Grounding cable with lug, screws, and washers (not provided).
z(Optional) 23-in. mounting brackets (provided).
Part 1: Mount the Optical ILA
The optical inline amplifier (optical ILA) can be mounted on a two-post rack.
NOTE: Place the rack in its permanent location, allowing adequate clearance for airflow
and maintenance, and secure it to the building structure. If you are mounting multiple
units in the rack, mount the heaviest unit at the bottom and mount the other units from
bottom to top in order of decreasing weight. The DC-powered optical ILA weighs 11.8 lb
(5.35 kg) and the AC-powered optical ILA weighs 11.7 lb (5.30 kg).
To mount the optical ILA on two posts of a rack by using the provided mounting kit:
1. Attach the ESD grounding strap to your bare wrist and to a site ESD point.
2. Position the optical ILA in such a manner that the FRUs are next to the hot aisle.
NOTE: The 19-in. brackets are attached to the optical ILA when they are shipped. If you
want to attach the 23-in. brackets, unscrew the 19-in. brackets from the chassis, and
attach the 23-in. brackets by using the same screws.
3. Use four mounting screws (and cage nuts and washers if your rack requires them) to
attach the optical ILA to the rack as shown in the illustration.
4. Tighten the screws.
5. (Optional) Attach a grounding cable to earth ground and then attach it to the chassis
grounding point.
Part 2: Connect Power to the Optical ILA
The optical ILA is supplied with two factory-installed power supplies. For instructions on
connecting DC power, see the installation instructions in the Optical Inline Amplifier
Hardware Guide.
To connect power to an optical ILA with AC power supplies:
1. To prevent damage to the equipment caused by static discharge, attach an ESD
grounding strap to your bare wrist, and connect the strap to an approved site ESD
grounding point.
2. Ensure that the power supplies are fully inserted in the chassis and the latches are
secure.
3. If the AC power source outlet has a power switch, set it to the off (O) position.
4. Insert the coupler end of the power cord into the AC power cord inlet on the AC
power supply faceplate.
5. Open the power cord retainer by pressing the protruding tab and prying it open. Wrap
the power cord retainer around the AC power cord and push the cable clamp through
the hole to tighten.
g009048
LINEAIN
LINEAOUT
LINEBIN
LINEBOUT
MONAOUT
MONBOUT
CON
MGMT
USBUSB
ON/OFF
OSCA
OSCB PWR
SYS
ALM
g009037
Juniper Networks, Junos, Steel-Belted Radius, NetScreen, and ScreenOS are registered trademarks of Juniper Networks, Inc. in the United States and other countries. The Juniper Networks Logo, the Junos logo, and JunosE are
trademarks of Juniper Networks, Inc. All other trademarks, service marks, registered trademarks, or registered service marks are the property of their respective owners. Juniper Networks assumes no responsibility for any inaccuracies
in this document. Juniper Networks reserves the right to change, modify, transfer, or otherwise revise this publication without notice. Products made or sold by Juniper Networks or components thereof might be covered by one or more
of the following patents that are owned by or licensed to Juniper Networks: U.S. Patent Nos. 5,473,599, 5,905,725, 5,909,440, 6,192,051, 6,333,650, 6,359,479, 6,406,312, 6,429,706, 6,459,579, 6,493,347, 6,538,518, 6,538,899,
6,552,918, 6,567,902, 6,578,186, and 6,590,785. Copyright © 2016 Juniper Networks, Inc. All rights reserved. Printed in Malaysia. Part Number: 530-067368 Revision 01, 1 April 2016.
6. Repeat the steps for each power supply you are connecting.
7. Insert the power cord plug into an AC power source outlet.
NOTE: The optical ILA powers on as soon as power is provided to the power supply.
8. If the AC power source outlet has a power switch, set it to the on (|) position.
9. Verify that the status LED for each power supply is lit green and is on steadily.
Part 3: Perform the Initial Configuration
You must perform the initial configuration of the optical ILA through the console port.
Before you begin, set the following parameter values from the console server or PC:
zBaud Rate—115200
zFlow Control—None
zData—8
zParity—None
zStop Bits—1
zDCD State—Disregard
To connect and configure the optical ILA from the console:
1. Connect the console port to a laptop or PC by using the provided RJ-45 cable and
RJ-45 to DB-9 serial port adapter. The console (CON) port is located on the
management panel of the optical ILA.
2. Log in as the root user. Enter the default password root.
login: root
3. Start the command-line interface (CLI).
root@% localhost:~# /usr/bin/command
Welcome to ILA World
BPS>
4. To enter the administrative mode, log in as the root user with password Admin@123.
BPS>login
Username: root
Password: *********
Completed!
BPS>
5. You can use the CLI commands documented in the Optical Inline Amplifier Hardware
Guide to configure, monitor, and troubleshoot the optical ILA.
Safety Warnings Summary
This is a summary of safety warnings. For a complete list of warnings, including
translations, see the optical ILA documentation at http://www.juniper.net/techpubs/.
WARNING: Failure to observe these safety warnings can result in personal injury
or death.
zOnly trained and qualified personnel are permitted to install or replace the optical ILA
components.
zPerform only the procedures described in this quick start and the optical ILA
documentation. Other services must be performed by authorized service personnel.
zBefore installing the optical ILA, read the planning instructions in the optical ILA
documentation to make sure that the site meets power, environmental, and clearance
requirements for the optical ILA.
zBefore connecting the optical ILA to a power source, read the installation instructions
in the optical ILA documentation.
zIf the rack or cabinet has stabilizing devices, install them in the rack before mounting or
servicing the optical ILA in the rack or cabinet.
zBefore installing or after removing an electrical component, always place it
component-side up on a flat antistatic mat or in an antistatic bag.
zDo not work on the optical ILA or connect or disconnect cables during electrical
storms.
zBefore working on equipment that is connected to power lines, remove jewelry,
including rings, necklaces, and watches. Metal objects heat up when connected to
power and ground and can cause serious burns or become welded to the terminals.
Contacting Juniper Networks
For technical support, see:
http://www.juniper.net/support/requesting-support.html
G