OWNER’S MANUAL
SUBMERSIBLE SOLIDS HANDLING PUMPS
Questions, problems, missing parts? Before returning to the store call K2 Customer
Service 8 a.m. - 6 p.m., EST, Monday-Friday
1-844-242-2475 © 2019 Copyright GP Enterprises Co., Ltd.
Rev. 11/4/19
SWW05002TPK
SWW07503TPK
Model:
SWW05002TPK/SWW05002VPK
SWW07503TPK
SWW05001TPK/SWW05001VPK
SWW07501TPK/SWW07501VPK
SWW05001VPK
SWW07501VPK
SWW05001TPK
SWW07501TPK
SWW05002VPK

2 For Professional Technical Support call 1-844-242-2475
PERFORMANCE
SKU
HP
GPH of Water @ Total Feet Of Lift
Max. Lift
0 ft.
5 ft.
10 ft.
15 ft.
20 ft.
25 ft.
SWW05002TPK
SWW05002VPK
1/2
6500
5000
4200
2400
18 ft.
SWW07503TPK
3/4
8700
7500
6000
3900
20 ft.
SWW05001TPK
SWW05001VPK
1/2
9000
7320
5400
2700
20 ft.
SWW07501TPK
SWW07501VPK
3/4
14000
11700
9600
6600
3900
23 ft.
SAFETY INSTRUCTION
1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion
or fire, resulting in property damage, serious personal injury, and/or death.
2. ALWAYS disconnect the power to the pump before servicing.
3. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
5. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7. Release all pressure and drain all water from the system before servicing any component.
8. Wear safety goggles at all times when working with pumps.
9. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-conductor
cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong plug must
be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not use this
pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle (a GFCI
outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All wiring should
be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15Amp for SWW05002TPK, SWW05002VPK and
20Amp forSWW07503TPK, SWW05001TPK, SWW05001VPK, SWW07501TPK, SWW07501VPK, fuse or circuit
breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.
15. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping
the pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature
failure.
16. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and
debris. Disconnect the pump from the power supply before inspecting.

For Professional Technical Support call 1-844-242-2475 3
17. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all
Occupational Safety and Health Administration (OSHA) guidelines must be followed.
18. The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset
itself once the motor cools down and an acceptable temperature has been reached. The pump may start
unexpectedly if it is plugged in.
19. Ensure the electrical power source is adequate for the requirements of the pump.
20. This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time
when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris
may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump
problems and remedies.
PRE-INSTALLATION
APPLICATION
Submersible sewage pumps and designed for pumping sewage, effluent, wastewater or flooded water with up to 2 inch
solids.
The pump is built with overload thermal protections and auto reset. The pump is equipped with a 10’ 3-prong
grounding-type power cord and piggyback-style switch for automatic or manual operation. Ball bearings on motor shafts
never need lubrication.
TOOLS REQUIRED
MATERIALS REQUIRED (NOT INCLUDED)
Thread Tape
2”Check
Valve
2’’ ABS or PVC
Pipe
ABS or PVC
Cement
(to match the pipe)
2”90°
Elbow
Phillips
Screwdrive
r
Flathead
Screwdriver
Safety
Goggles
Tape
Measure
Channel
Locks
Pipe Wrench
Cable Ties
Hacksaw

4 For Professional Technical Support call 1-844-242-2475
SPECIFICATIONS
NOTICE:Read this Owner’s Manual for installation, operation, and safety information.
INSTALLATION
NOTICE: Install pump on a hard, level surface (cement, asphalt, etc.). Never place pump directly on earth, clay or
gravel surfaces.
Piping –Effluent Applications (3/4”or Less Solids)
Piping must be 1-1/2”minimum to carry volume of pump discharge. Check local codes to determine if a check valve is
required in your system. In cold climates, check valves are not used to prevent effluent from freezing in piping.
If using as a sump pump, a check valve is recommended.
Piping –Sewage Applications (2”or Less Solids)
In any case, piping must not be smaller than pump discharge. When installed in a sewage system, pipe must be capable
of handling semi-solids of at least 2”(5.1 cm) diameter. The rate of flow in the discharge pipe must keep any solids
present in suspension in the fluid. To meet minimum flow requirements, the minimum pipe size is 2”.
Use a 2”(5.1 cm) swing check valve in pump discharge to prevent backflow of liquid into sump basin. Check valve
should be a free flow valve that will easily pass solids.
NOTICE: For best performance of check valve when handling solids, do not install it with discharge angled more than
45°above the horizontal. Do not install check valve in a vertical position as solids may settle in valve and prevent
opening on start up.
Drill a 1/8”(3.2mm) hole in discharge pipe about 1”-2”(2.5 - 5.1cm) above pump discharge connection (but below check
valve) to prevent air locking the pump.
PIPE QUICK CONNECTION:
Insert rigid plastic pipe into the quick connector.
Hand tighten the knurling nut of the quick connector as tight as possible.
Power supply
SWW05002TPK/ SWW05002VPK:115V, 60 HZ., 15 Amp Circuit
SWW07503TPK/SWW05001TPK/SWW05001VPK/SWW07501TPK/SWW07501VPK:
115V, 60 HZ., 20 Amp Circuit
Liquid temp. range
32-131°F (0-55°C)
Discharge size
2” FNPT
Sump basin
Minimum 22 in. (559 mm) diameter, 30 in. (760 mm) depth

For Professional Technical Support call 1-844-242-2475 5
For SWW05002TPK/ SWW05002VPK /SWW07503TPK/SWW05001TPK/SWW07501TPK installation
For SWW05001VPK/SWW07501VPK installation
1. Fasten the bracket onto the switch with two screws.
2. Attach the bracket and switch to the discharge pipe with clamp (included), being sure to keep the vertical switch
vertical. Notice: the bottom of the float ball must be (2 in. above) the inlet of the pump.
3. Tie the power cords of pump and vertical switch to the discharge pipe with cable tie (not included).
Electrical
WARNING: Risk of electric shock. Can shock, burn or kill. When installing, operating, or servicing this pump,
follow safety instructions listed below.
1. DO NOT splice the electrical power cord.
2. DO NOT allow electrical cord plug to be submerged.
3. DO NOT use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or
damage motor.
SWW05002TPK/SWW07503TPK/
SWW05001TPK/SWW07501TPK
SWW05002VPK

6 For Professional Technical Support call 1-844-242-2475
4. DO NOT handle or service pump while it is connected to power supply.
5. DO NOT remove grounding prong from plug or modify plug to protect against electrical shock, the power cord is a
three-wire conductor and includes a 3-prong grounded plug. Plug pump into a 3-wire, grounded, grounding type
receptacle. Connect pump according to electrical codes that apply.
For automatic operation, plug or wire pump into an automatic float switch or pump controller. Pump will run continuously
when plugged directly into an electrical outlet. Connect or wire pump to an individual branch circuit with no other outlets
or equipment in the circuit.
Size fuses or circuit breakers according to chart below.
Fuse Data
MODEL
HP
Voltage
Individual Branch
Circuit Required
(Amps)
SWW05002TPK/SWW05002VPK
1/2
115
15
SWW07503TPK
3/4
115
20
SWW05001TPK/SWW05001VPK
1/2
115
20
SWW07501TPK/SWW07501VPK
3/4
115
20
OPERATION
WARNING: Do not handle this pump or plug in or unplug this pump with wet hands or while standing in water, unless you
are certain all power has been turned off to the pump. Remember, the pump should be connected only to a properly
grounded, GFCI outlet.
1. Make certain the pump is submerged in water. Running the pump dry can damage the shaft seal.
2. Plug the pump cord into the back of the float switch cord’s plug. Plug the float switch cord into a 115V GFCI power
outlet.
3. After connecting power to the pump and periodically afterwards, test the pump:
a. Fill the basin to above the float switch operation ON Height. The pump should start pumping.
b. The pump should pump the water down to below its float switch operation OFF Height and then stop pumping.
c. If the water drains back into the basin and restarts the pump, make sure the check valve is properly installed
and working. Also make sure that all pipe connections are tight.
4. The motor is equipped with an automatically resetting thermal overload protector. If the motor gets too hot, the
overload protector will shut off the pump before it is damaged. When the motor has cooled sufficiently, the overload
protector will reset, and the motor will restart.
NOTICE: If the overload protector stops the pump repeatedly, disconnect the power from the pump and check to find the
problem. Low voltage, a long extension cord, clogged impeller, screen blocked by debris, or water that is too hot can
cause motor overheating.

For Professional Technical Support call 1-844-242-2475 7
CARE AND CLEANING
CAUTION: Always use the handle to lift the pump. Never use the power cord to lift the pump. To avoid skin burns,
unplug the pump and allow time for it to cool after periods of extended use.
Do
Do Not
When the power is disconnected, inspect the
pump suction screen and remove all debris,
then plug the pump back into the grounded
(GFCI) outlet.
Do not disassemble the motor housing. This motor
has NO repairable internal parts, and disassembly
may cause leakage or dangerous electrical wiring
issues.
Do not lift up the pump by the power cord.
For SWW05002TPK, SWW05002VPK, SWW05001VPK, SWW07501VPK,
SWW05001TPK, SWW07501TPK
Before removing pump from basin for service, always disconnect electrical power to pump and control switch.
Submerge pump in a disinfectant solution (bleach) for at least one hour before disassembling pump.
Unscrew the bolts, and remove the volute/gasket.
Use a flathead screwdriver to hold the shaft, then turn the impeller counter clockwise to release the impeller.
Remove debris from around the shaft and on/under the impeller.
Reassemble the pump.
SWW05002TPK/ SWW05002VPK
SWW05001TPK/SWW05001VPK/SWW07501TPK/SWW07501VPK

8 For Professional Technical Support call 1-844-242-2475
For SWW07503TPK
Before removing pump from basin for service, always disconnect electrical
power to pump and control switch.
Submerge pump in a disinfectant solution (bleach) for at least one hour
before disassembling pump.
Put the pump upside down.
Note: Pump is oil filled, don’t incline the pump to void the oil leakage.
Unscrew the stainless screws, and remove the volute/gasket.
Use a flathead screwdriver to hold the shaft, then turn the impeller
counterclockwise to release the impeller.
Remove debris from around the shaft and on/under the impeller.
Reassemble the pump.
TROUBLESHOOTING
Do not disassemble the motor housing. This motor has NO repairable internal parts, and disassembly may
cause an oil leak or dangerous electrical wiring issues. DO NOT lift up the pump by power cord.
Problem
Solution
The pump fails to operate.
1. Check to be sure that the power cord is securely plugged into an outlet.
Disconnect power to the outlet before handling the pump or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid levels are high enough to activate the switch or
controller.
4. Check to be sure that a 1/8 in.(3.2mm) vent hole in the discharge pipe is
not plugged.
5. Check for blockage in the pump inlet, impeller, check valve or discharge
pipe.
6. Thermal overload may have tripped. Test start the pump. If it starts and
then stops immediately, disconnect from the power source for 30 minutes
to allow the motor to cool, then reconnect to the power source. Check for
cause of overheating/overloading.
The pump fails to empty sump.
1. Be sure all valves in the discharge are fully open.
2. Clean out the discharge pipe and check valves.
3. Check for blockage in the pump inlet or impeller.
The pump will not shut off.
1. Check the switch or controller automatic floats for proper operation and
location.
2. If the pump is completely inoperative or continues to malfunction, call
customer service.

For Professional Technical Support call 1-844-242-2475 9
WARRANTY
Limited Warranty
WHAT THIS WARRANTY COVERS
When used and maintained in normal use and in accordance with the Owner’s Manual, your K2 product is warranted
against original defects in material and workmanship for at least one year (warranty varies depending on model; see box
for specific warranty information) from the date of purchase (the “Warranty Period”). During the Warranty Period, K2 will
repair or replace at no cost to you, to correct any such defect in products founds upon examination by K2 to be defective
in materials or workmanship.
Your dated receipt of purchase is required to make a warranty claim.
WHAT THIS WARRANTY DOES NOT COVER
This Warranty does not cover:
Use of the product in a non-residential application, improper installation and/or maintenance of the product, damage due
to misuse, acts of God, vandalism or other acts beyond control of K2, owner’s acts or omissions, use outside the country
in which the product was initially purchased and resale of the product by the original owner. This warranty does not
cover pick up, delivery, transportation or house calls. However, if you mail your product to a K2 Sales and Service Center
for warranty service, cost of shipping will be paid one way. This warranty does not apply to products purchased outside
of the United States, including its territories and possessions, outside of U.S. Military Exchange and outside of Canada.
This warranty does not cover products purchased from a party that is not an authorized retailer, dealer or distributor of
K2 products.
OTHER IMPORTANT TERMS
This warranty is not transferable and may not be assigned. This Warranty shall be governed and construed under laws
of the state of Michigan. The Warranty Period will not be extended by any replacement or repair performed under this
Warranty. THIS WARRANTY IS THE EXCLUSIVE WARRANTY AND REMEDY PROVIDED BY K2. ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OR MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE, ARE DISCLAIMED. IN NO EVENT WILL K2 BE LIABLE FOR ANY SPECIAL, INDRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR NATURE TO OWNER OR ANY PARTY
CLAIMING THROUGH OWNER WHETHER BASED IN CONTRACT, NEGLIGENCE, TORT, OR STRICT PRODUCTS
LIABLITY OR ARISING FROM ANY CAUSE WHATSOEVER. Some states do not allow for the exclusion of
consequential damages, so the above exclusion maynot apply to you. This warrantygives you specific rights. You may
also have others that vary from state to state.
Thank you for choosing a K2 product!
This manual suits for next models
6
Table of contents
Other K2 Water Pump manuals
Popular Water Pump manuals by other brands

YOKOGAWA
YOKOGAWA 91056 user manual

ASM
ASM AllPro Mustang 4700 Plus Hi-Boy Repair

Comet
Comet IDS 960 Assembly and maintenance instructions

EHEIM
EHEIM StreamON+ 2000 operating instructions

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS PA Series Installation, operation and maintenance manual

Thomas
Thomas 008CA13 quick start guide

Wilo
Wilo Multivert MVIS Series Installation and operating instructions

Graco
Graco 260550 Instructions-parts list

Pfeiffer Vacuum
Pfeiffer Vacuum adixen ATH 500 M operating instructions

BVA Hydraulics
BVA Hydraulics PG5505 instruction manual

Graco
Graco G-JR Instructions-parts list

Hamron
Hamron 023629 operating instructions