Kalora SORRENTO User manual

SORRENTO
OWNERS MANUAL
INSTALLATION CHECKLIST
The Installation technician must check the following items before leaving the
premises.
Ensure the physical installation is complete including:
Flue installation
Media Installation
Gas type conversion (If required)
Ensure gas inlet and outlet pressure values are set according to the compliance plate
Please contact the relevant authority if gas inlet pressure is insucient
Ensure that a gas leakage (pressure) test is carried out before commissioning the heater
Any other test required by relevant authorities are carried out
Ensure that remote control is paired with the heater
(Please refer to remote control instructions, page 20)
Commission the heater and ensure the operation is satisfactory
If you have any problems carrying out any of the tasks above or if the heater operation is not satisfactory, please contact Kalora.
Kalora Pty Ltd.
Head Oce
58-60 Access Way,
Carrum Downs VIC 3201
Australia
(03) 8579 5900
www.kalora.com.au
Model Name SORRENTO
Model Number KAGAS10
Ka.Sor Version: 1.6 8/4/19
The copy of the manual provided with your Kalora appliance was current
at the time of manufacture, on occasion there is need for revision
therefore we recommend checking our website to ensure the version
supplied is the most current


1
Introduction 1
Safety precautions 2
Compliance plate 3
Your heater at a glance 4
Product dimensions 5
Installation guide 6
- Clearances to combustibles 7
- Flue installation 8
- Prohibited area for flue terminals 9
- Media installation procedure 11
- Plaster channel installtion 13
- Clearance stand off installation 14
- Fascia clearnance installation 16
- Gas type conversion 16
- Fascia installation 18
- App control WiFi module installation 18
Operating instructions 19
- Remote control instructions 19
- App control overview and operation 20
Heater maintenance 23
- Routine maintenance schedule 24
- Component access 24
Troubleshooting 26
Wiring diagram 27
Sorrento exploded diagram and parts list 28
Media spare parts list 32
Warranty 33
INTRODUCTION
Congratulations on purchasing a genuine Kalora gas space heater. When cared for properly, these high
quality, finely crafted gas space heaters will offer many years of reliable performance. This instruction
manual has been developed to ensure optimum performance from your Kalora gas space heater. It’s
very important that you thoroughly read and understand all instructions before using your new heater.
COUNCIL REQUIREMENTS
Check Local Council Requirements E.g. permits
When installing, operating and maintaining your gas space heater, follow the guidelines presented in
these instructions, and make them available to anyone using or servicing the gas space heater.
Your city, town, state or territory may require a building permit to install a gas space heater.
Always consult your local building inspector or local council to determine what regulations apply in your
area.
CONTENTS
Please note:
Your gas space heater must be installed by a qualified person whose
work conforms with local council regulations, Australian standards
&manufacturers recommendations. Failure to do so willvoid your
warranty and could possibly void any home insurance.

2
SAFETY PRECAUTIONS
When properly maintained and operated your gas space heater should give
you many years of service, however there are important safety aspects of these
products that you need to be aware of when operating a gas space heater.
1. DO NOT PLACE ARTICLES ON OR AGAINST THIS APPLIANCE.
2. DO NOT USE OR STORE FLAMMABLE MATERIAL NEAR THE APPLIANCE.
3. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILST IT IS IN OPERATION.
4. DO NOT MODIFY THIS APPLIANCE.
5. NOT SUITABLE TO BE INSTALLED IN A MARINE ENVIRONMENT.
INSTALLATION NOTICE
1. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
2. INSTALLATION OF THIS APPLIANCE IS ONLY TO BE CARRIED OUT IN ACCORDANCE WITH
THE MANUFACTURER’S INSTRUCTIONS, LOCAL GAS FITTING REGULATIONS, AS5601-2004
INSTALLATION CODE FOR GAS BURNING APPLIANCES AND ANY OTHER RELEVANT STATUTORY
REGULATIONS.
3. THE APPLIANCE BASE MUST BE FULLY SUPPORTED ON A LEVEL SURFACE (E.G. SOLID FLAT
FLOOR OR SUPPORTING BOARD THAT SUPPORTS THE WHOLE BASE OF THE UNIT).
WARNING
1. THE KALORA SORRENTO HAS A PRIMARY SAFETY GUARD FITTED IN FRONT OF THE GLASS
DOOR. THIS SAFETY GUARD IS FITTED TO REDUCE THE RISK OF INJURY FROM BURNS AND
ATNO TIME SHOULD THIS GUARD BE PERMANENTLY REMOVED.
2. GLASS AND OTHER SURFACES ARE HOT DURING OPERATION AS WELL AS DURING THE COOL-
ING DOWN PERIOD. PRECAUTION SHOULD BE TAKEN AND YOUNG CHILDREN MUST BESUPER-
VISED AT ALL TIMES.
NOTE
1. A SLIGHT SMELL MAY BE APPARENT FOR THE FIRST FEW HOURS OF USE. THIS IS DUE TO
THEHEAT RESISTANT PAINT CURING. IT IS RECOMMENDED TO OPEN WINDOWS IN THE
ROOMFOR THE FIRST LIGHTING OF THE FIRE. IN SOME INSTANCES, A SLIGHT DISCOLOURA-
TION MAY OCCUR INSIDE THE FIREBOX, THIS IS A NORMAL CONDITION ANDISNOT COVERED
BYWARRANTY.
IF YOU SMELL GAS
1. DO NOT TRY TO LIGHT THE APPLIANCE.
2. DO NOT TOUCH ANY ELECTRICAL SWITCHES NEAR THE APPLIANCE.
3. DO NOT USE YOUR PHONE IN THE VICINITY OF THE APPLIANCE.
4. IMMEDIATELY CALL YOUR GAS SUPPLIER (NOT IN THE VICINITY OF THE APPLIANCE) AND
FOLLOW THEIR INSTRUCTIONS.
5. IF YOU CANNOT REACH YOUR GAS SUPPLIER, CALL THE FIRE DEPARTMENT.

3
COMPLIANCE PLATE
SERIAL NO: KAGAS10 - YY -
MANUFACTURE DATE:
IAPMO APPROVAL NO: GMK10499
THIS PRODUCT IS TESTED IN ACCORDANCE WITH AS/NZS5263.1.3-2016 AND AS3100
NATURAL GAS PROPANE GAS
Outlet gas pressure 0.95 kPa 2.41 kPa
Nominal (maximum) gas consumption 25.5 MJ/h 23.0 MJ/h
Turn down gas pressure 0.40 kPa 0.68 kPa
Turn down gas consumption 17.0 MJ/h 12.7 MJ/h
Main burner injector 2.3mm 1.4mm
Primary aeration opening 15mm Fully open
Electrical requirements 220-240V/50Hz
CERTIFICATE HOLDER: MADE IN CHINA
KALORA PTY LTD
58 Access Way, Carrum Downs.
3201 VIC Australia
PH: 03 5792 2388

4
MEDIA
REMINDER:
This gas space heater should only be installed by an authorised
technician in accordance with:
- AS/NZ 5601.1: Gas Installation Code
- Manufacturers installation instruction
- Local gas fitting regulations
- Municipal building codes.
2
3
4
5
6
7
YOUR HEATER AT A GLANCE
PROPANE
CONVERSION
KIT
SORRENTO
OWNERS MANUAL
KaloraHeating(Aust) Pty Ltd
HeadOce
58Access Way,
CarrumDowns 3201
Australia
Warehouse
Lot1 Melbourne Cresent,
SeymoreVIC 3660
Australia
+6135792 2388
www.kalora.com.au
ModelName Sorrento
ModelNumber KAGAS10
1
1. Gas space Heater
2. Fascia (Beautiful Black)
3. Remote Control (Must be paired, see remote control instructions)
4. App Control Module (Optional accessory)
5. Media (Driftwood Log Set and Pebbles with Glass)
6. Propane Conversion Kit
7. Owners Manual / Warranty Card
8. External fixtures – plaster tabs, clearance tabs, fascia extension
8

5
FASCIA
Electrical
Connection
PRODUCT DIMENSIONS (mm)
484
472
283
842
790
32
48
620
1245
1035
1294
TRUE R30
TRUE R25 297
80
10
100 175
955
1234
410
484
472
283
842
790
32
48
620
1245
1035
1294
TRUE R30
TRUE R25 297
80
10
100 175
955
1234
410
Gas Connection
(1/2” Male Thread)
HEATER

6
INSTALLATION GUIDE
CLEARANCES TO COMBUSTIBLES
It is extremely important that you respect required installation distances and that you respect local
installation regulations.
This is for your safety! The manufacturer is not responsible for the product, if it is not installed following
these recommendations.
A combustible surface is anything that can burn (i.e. plaster, wall paper, wood, fabrics etc.) These surfaces
are not limited to those that are visible and also include materials that are behind non-combustible
materials. If you are not sure of the combustible nature of a material, consult your local fire ocials.
Minimum clearance for a combustible surface
Please note:
Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams
are not drawn to scale. Actualproduct may vary from pictures in manual.
ASide of the heater 40mm
BBack of the heater 30mm
CDistance from flue pipe 25mm
DTop of the heater 50mm
EFloor below the heater 0mm
D
E
A
C
B
Please do not
insert screws in the
shaded area as you
could damage the
components within
the heater.

7
INSTALLATION GUIDE
CLEARANCES TO COMBUSTIBLES ...continued
Minimum Framing Dimensions
AApprox opening (vent pipe) 220mm
BApprox opening (height) 867mm
CApprox opening (depth) 480mm
DApprox opening (width) 1314mm
Minimum clearance for a combustible surface
FLOOR MOUNT INSTALLATION MID MOUNT INSTALLATION
A
Mantel height from top of
the fireplace opening (mm) 360mm
BSide Wall 80mm
CCeiling 1000mm
DMantel Depth (max) 330mm
E
Front floor
(non-combustible) 0mm
FAlcove depth 915mm
G
Isolation switch max
distance 1000mm
The appliance base must be fully
supported on a level surface
(e.g. solid flat floor or supporting board
that supports the whole base of the unit).

8
IMPORTANT:
Your Kalora gas space heater must be vented directly to the outside.
Length Vertical (V) Horizontal (H)
Minimum 900 mm 1x 900 mm flue pipes -
Maximum 5400 mm 6x 900 mm flue pipes 1800 mm
Note: Kalora direct vent flue products must be used for all installations.
5400mm
Max Vertical
Height
900mm
Min Vertical
Height
Ensure that flue configuration is
consistent with the requirements
specified in the below table.
INSTALLATION GUIDE
FLUE INSTALLATION
Vertical Vent Flue Installation
Minimum Vent Clearance
HORIZONTAL FLUE INSTALLATION
Rear Vent Flue Installation
Config Horizontal (H) Vertical (V)
A 1 x 90 Elbow + 1 x 900mm flue pipe
B 1 x 90 Elbow + 1 x 900m
flue pipe
+ 1 x 900mm flue pipe
C 1 x 90 Elbow + 3 x 900m
flue pipe
+ 2 x 900mm flue pipe
D 1 x 90 Elbow + 4 x 900m
flue pipe
+ 2 x 900mm flue pipe
Note: Kalora direct vent flue products must be used for all installations.
Ensure that flue configuration is consistent with
the requirements specified in the below table.
To extend Horizontal length the Vertical height
must also be extended to allow exhaust gas to
increase in speed to travel the extended length.
Select ONE of the following configurations:
Roof Pitch Angle 33.7o-
36.9o
36.9o -
39.8o
39.8o-
42.5o
42.5o-
45.0o
45.0 o-
49.4o
49.4o-
53.1o
53.1 o-
56.3o
56.3o-
59.0o
59.0o-
60.3o
Minimum Vent
Clearance (mm) 610 760 990 1220 1520 1830 2130 2290 2440
Maximum horizontal axis
deviation 1800mm

9
5400mm
Max Vertical
Height
900mm
Min Vertical
Height
T = Flue Terminal I = Mechanical Air Inlet M = Gas Meter P = Electricity meter or fuse box Z = Fan-assisted appliance only
ORANGE SHADING INDICATES PROHIBITED AREA FOR FLUE TERMINALS
PROHIBITED AREA FOR FLUE TERMINALS
INSTALLATION GUIDE

10
INSTALLATION GUIDE
PROHIBITED AREA FOR FLUE TERMINALS ...continued
Reference Item Min Clearance^
A Below eaves, balconies and other projections
Appliances up to 50 MJ/h input 300mm
Appliances over 50 MJ/h input 500mm
B From the ground, above a balcony or other surface* 300mm
C From a return wall or external corner* 500mm
D From a gas meter (M)* (See Note 3) 1000mm
E From an electricity meter or fuse box (P) #(See Note 3) 500mm
F From a drain pipe or soil pipe 150mm
G Horizontally from any building structure* or obstruction facing a terminal 500mm
H From any other flue terminal, cowl, or combustion air intake* 500mm
J
Horizontally from an openable window, door, non-mechanical air inlet, or any other opening into a building
with the exception of sub-floor ventilation
Appliances up to 150 MJ/h input* 500mm
Appliances over 150 MJ/h input p to 200 MJ/h input* 1500mm
Appliances over 200 MJ/h input up to 250 MJ/h input* 1500mm
Appliances over 250 MJ/h input* 1500mm
K From a mechanical air inlet, including a spa blower 1500mm
N
Vertically below an openable window, non mechanical air inlet, or any other opening into a building with the
exception of sub-floor ventilation
Space heaters up to 50 MJ/h input 150mm
Other appliances up to 50 MJ/h input 500mm
Appliances over 50MJ/h input and up to 150 MJ/h input 1000mm
Appliances over 150 MJ/h input 1500mm
* Unless appliance is certified for closer installation
^ Natural draft flue configuration only
# Prohibited area below electricity meter or fuse box extends to ground level
1. Where dimensions C, J or K cannot be achieved or an equivalent horizontal distance measured diagonally from the
nearest discharge point of the terminal to the opening may be deemed by the technical regulator tocomply.
2. For appliances not addressed above acceptance should be obtained from the technical regulator
3. Minimum clearances D and E also apply to any combustion air intake openings of appliances
Notes

11
Vermiculite Burner
105mm 265mm 120mm
Using the vermiculite, fill the burner up to 10-15mm deep, evenly spread across the tray.
Use 3 Lava rocks provided and place them according to the distances below. *
Glass Burner (Default)
105mm 265mm 120mm
Using the glass provided, fill the burner up to 10-15mm deep, evenly spread across the tray.
Use 3 Lava rocks provided and place them according to the distances below. *^
INSTALLATION GUIDE
MEDIA INSTALLATION PROCEDURE
*Lava rock should not be used for propane gas horizontal flue configuration
^Lava rocks should not be used for natural gas horizontal flue configuration

12
Glass Burner with Drift Wood (Default)
Glass Burner with Pebbles
Place the logs and pebbles provided in their designated location. Apart from the burner media, no other log or pebble should
cross the flame. Important: Logs and pebbles should be placed in the same location as depicted in the image below.
Place the pebbles provided in their designated location. Apart from the burner media, no other log or pebble should
crosstheflame. Important: Logs and pebbles should be placed in the same location as depicted in the image below.
Vermiculite Burner with Driftwood
Vermiculite Burner with Pebbles
Place the logs and pebbles provided in their designated location. Apart from the burner media, no other log or pebble
should cross the flame. Important: Logs and pebbles should be placed in the same location as depicted in the image below.
Place the pebbles provided in their designated location. Apart from the burner media, no other log or pebble should cross
theflame. Important: Logs and pebbles should be placed in the same location as depicted in the image below.
INSTALLATION GUIDE
MEDIA INSTALLATION PROCEDURE ...continued
A A
A
EE
E
E
FF
F
FF
F
F
I
K
M
N
C
C
C
D
D
D
H
G G G
GG
G
G
B
B
J
L

13
INSTALLATION GUIDE
PLASTER CHANNEL
This unit comes with a plaster channel to assist with the addition of plaster to fit flush with the unit.
The brackets allow for 9-15 mmm plaster to be used. Assembly is as follows:
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket Install
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket Install
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
Attach the top
plaster bracket.
Attach the two side
plaster bracket.
The depth of the
bracket can be
adjusted by moving
them within the
slot to achieve the
desired depth fom
front of the unit.

14
INSTALLATION GUIDE
CLEARANCE STAND OFF INSTALLATION
Clearance stand off tabs are provided with the heater and can be found inside the firebox.
Please make sure you attach these stand off tabs prior to installation of the heater.
These stands also add integrity to the case.
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Stan Off
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Stan Off
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Stan Off
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna

15
INSTALLATION GUIDE
FASCIA EXTENSION
The unit has adjustment steps on the fascia which allow it to accomodate thicker wall finishings like tiles.
Adjust the fascia until it fits flush to the wall surface.
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket - Austale2
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket - Austale2
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket - Austale2
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Plaster Bracket - Austale2
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna
Adjustment step 1. Adjustment step 3.
Adjustment step 4.Adjustment step 2.
For Complete Dimensions Refer to CAD File
PART:
Circled Dimensions
On Drawing
MUST BE INSPECTED
Dimensional Tolerances,
Unless Otherwise Stated Are:
KGSH Sorrento_Manual
Two Decimal Places = +/- 0.05
One Decimal Place = +/- 0.1
Zero Decimal Places=+/- 0.5
Stan Off
SCALE 1:10 A3
Dimensions in Millimeters
Title:
COPYRIGHT and CONFIDENTIAL
Material Grade:
Treatment:
Gauge:
Material Type:
Colour:
Weight (g):
Finish:
Auth.
Date
Issue
Change Detail
J. Young
1.0
20/02/18
Drw
D. Wickramarathna

16
The heater is configured for natural gas by default. Use conversion kit included in packaging to do
propane gas type conversion. Please follow the steps below to convert the heater to propane gas:
STEP 1
Replace the main burner injector
using the injector provided in the
conversion kit.
STEP 4
Remove two nuts and the earth
lead terminal as shown below.
STEP 3
Remove 4 screws from the
base of the pilot assembly, then
slightly lift from the heater.
STEP 7
Remove and replace the pilot
injector using the injector
provided in the conversion kit.
STEP 2
Please refer to the compliance
plate/product specification
table to ensure the correct
injector size.
STEP 8
Please refer to the compliance
plate/product specification
table to ensure the correct
injector size.
STEP 5
Remove two screws and
carefully remove the pilot
burner assembly.
STEP 9
Change the primary aeration
opening to suit the propane
gas type. Please refer to the
compliance plate/product
specification table to ensure the
correct opening size.
STEP 6
Using a spanner, remove the
nut to access the pilot injector.
Main
Burner
Injector
INSTALLATION GUIDE
GAS TYPE CONVERSION

17
Inlet
pressure
Outlet
pressure
Max adj. nut
Min adj. screw
The heater is configured for natural gas by default. Use conversion kit included in packaging
to do propane gas type conversion. Please follow the steps below to convert the heater to propane gas:
STEP 11
Remove the selector jumper
as shown in the image below.
This will activate the propane
configuration of the control
board.
STEP 12
Change the outlet pressure of
the gas valve to suit propane
gas type. Inlet and outlet test
points may be used to check
the pressure while doing the
adjustments.
STEP 13
A SIT pressure adjustment tool may be used to adjust the pressure. Alternatively
a phillip head screw driver and a 10mm spanner can be used. When adjusting
the maximum pressure, hold the screw driver in place and turn the spanner.
When adjusting the minimum pressure hold the spanner in place and turn the
screwdriver.
STEP 10
Locate the Millennium control
board and remove three screws
as shown in the image below.
Carefully lift the cover to access
the selector jumper inside.
Selector
Jumper
INSTALLATION GUIDE
GAS TYPE CONVERSION

18
INSTALLATION GUIDE
FASCIA INSTALLATION
The Sorrento fascia includes two parts, the outer fascia and the primary guard. When installing/removing
please make sure the two items are separated in order to reduce the combined weight. The Sorrento
fascia is designed to accommodate multiple wall finishes of varying depth. When installing the fascia,
first bring the outer fascia closer to the heater and align the heater with the locating lugs in the body of
the heater insert slowly until the rear of the fascia is in the preferred position. Lower the outer fascia and
the mounting mechanism will self-locateonto lugs. Once the outer fascia has been installed, carefully
assemble the glass to the outer fascia.
To control your heater from your mobile phone or tablet from the Kalora Sorrento mobile app you need to
purchase theapp control WiFi module. Follow the steps below to install the WiFi module.
As shown in the images below, insert the 4 pin plug of the WiFi module into the control board.
APP CONTROL WIFI MODULE INSTALLATION
This manual suits for next models
1
Table of contents
Popular Indoor Fireplace manuals by other brands

Regency
Regency City Series New York 72 manual

Remii
Remii WM-SLIM-65 Installation and operation instruction

Valor
Valor COSYFLAME TURBOCHIM 528 Installer's guide

Sunjoy
Sunjoy D-CM003PST Assembly instructions

GDC Group
GDC Group BACH Instructions for use

Ekofires
Ekofires 1011 GRAND LED ELECTRIC Installation & user's instructions