1. Introduction
The KT-MOD-REL8 is an 8-relay outputs expansion module used
as general relays or elevator control outputs.
The module supports daisy chaining which can add up to 32 KT-
MOD-REL8 modules for a total of 256 external relays per KT-400
controller. You can mix relays and outputs in the same SPI group,
up to 256 outputs.
Note 1: The KT-400 SPI port maximum current draw, when the
12V AUX terminals are not used, is 500 mA.
Note 2: External power supply (12 VDC, 2 Amps) is required
when the total current draw exceeds 500mA on the SPI Port.
Note 3: There are already 4 relays available on the KT-400.
Make sure to check the relays number assignments to prevent
redundancy unless it has been planned on purpose.
2. Specifications
•Maximum Current Draw: up to 330 mA per module
•Each relay supports the 2 conditions, NO (Normally Open)
and NC (Normally Closed), the C (Common) terminal is +12
VDC
•Each relay has its own LED to indicate status, ON for active
•Eight (8) programmable relay contacts rated 30 VDC, 3 A
•Can be used for elevator control
•Can be mixed with output module KT-MOD-OUT16 in the
same group
3. Installing the KT-MOD-REL8 Module
3.1. Unpacking
The KT-MOD-REL8 package includes the following parts:
•One (1) module - 14 cm x 8 cm (5.7 in x 3.25 in)
•One (1) SPI cable with 1 SPI connector 41 cm (16 in)
•Four (4) plastic standoffs
•Two (2) installation sheets, English and French
3.2. Mounting
The KT-MOD-REL8 can be installed inside a compatible cabinet
(KT-MOD-CAB or KT-400) or mounted in a dry and secure
location at less than 1 m (3 ft) from the KT-400.
Perform the following steps to mount the unit:
1. Press the four (4) plastic standoffs through the mounting
holes of the cabinet,
2. Secure the cabinet to the wall in the desired location. Use
appropriate wall anchors when securing the cabinet to
drywall, plaster, concrete, brick or other surfaces,
3. Press the module into the plastic standoffs to secure the
module to the cabinet.
3.3. Installation and Wiring
Before beginning to wire the unit, ensure that all power (AC
transformer and battery) is disconnected from the KT-400.
Perform the following steps to complete wiring:
1. Connect the 6-pin SPI connector to:
•the KT-400 SPI port, or
•the SPI OUT of the previous output module (KT-MOD-
REL8 and KT-MOD-OUT16 only), or
•the SPI EXP of the 1st input module KT-MOD-INP16
connected to the KT-400 SPI port.
2. Connect the six SPI wires (blue (BLU), white (WHT), green
(GRN), yellow (YEL), black (BLK) and red (RED)) to the SPI
IN (TB1) terminals.
3. Connect the 6-pin SPI connector from the SPI OUT to the
next output module (KT-MOD-REL8 and KT-MOD-OUT16
only).
4. Complete all output wiring.
Tel.: 1 (450) 444 2030 •Toll Free: 1-888-222-1560 •Fax: 1 (450) 444 2029 •Internet: www.kantech.com DN1786-0809
Copyright © 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved. •Specifications may change without notice.
Kantech and the Kantech logo are trademarks of Tyco International Ltd. and its Respective Companies.
KT-MOD-REL8
KT-400 Expansion Module 8-Relay with SPI Cable Install Sheet
3.4. Check the power jumper JP1 position. Put it on EXT if you
need external power or INT if no external power is required.
3.5. Applying Power
After all wiring is completed, connect the 16 VAC to the KT-400.
Connect the battery leads to the battery, and then apply power to
the AC transformer.
Note: Do not connect power until all wiring is complete.
Terminal Connections
Module no.: ______________________________________________________________________________________
Date of installation: _______________________________________________________________________________
KT-400 Name: ____________________________________________________________________________________
KT-400 SITE NAME: _______________________________________________________________________________
KT-400 Serial Number: _____________________________________________________________________________
AUX: ___________________________________________________________________________________________
SPI BUS (FROM): _________________________________________________________________________________
SPI BUS (TO): ____________________________________________________________________________________
FNO RLY1: ____________________________________ FNO RLY5: ____________________________________
FNC FNC
FNO RLY2: ____________________________________ FNO RLY6: ____________________________________
FNC FNC
FNO RLY3: ____________________________________ FNO RLY7: ____________________________________
FNC FNC
FNO RLY4: ____________________________________ FNO RLY8: ____________________________________
FNC FNC
FCC & IC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Kantech could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class A device in accordance with
the specifications of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following
booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S.
Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4. This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including
interference that may cause undesired operation. This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations. The KT-400 is also compliant with EN55022: 1994, amendment 1: 1995, Class A.

Popular Relay manuals by other brands

IDEM SAFETY SWITCHES SCR-31-i quick start guide

IDEM SAFETY SWITCHES

IDEM SAFETY SWITCHES SCR-31-i quick start guide

Basler BE1-67 instruction manual

Basler

Basler BE1-67 instruction manual

Omron G9SX-ADA222-T Series user manual

Omron

Omron G9SX-ADA222-T Series user manual

Touch-plate ZoneZ Universal quick start guide

Touch-plate

Touch-plate ZoneZ Universal quick start guide

Circutor RGU-10 quick start guide

Circutor

Circutor RGU-10 quick start guide

Eaton EMR4-F500-2 Operating and installation instructions

Eaton

Eaton EMR4-F500-2 Operating and installation instructions

Hayward AQL-RELAY-AC-KT owner's manual

Hayward

Hayward AQL-RELAY-AC-KT owner's manual

Condor R5/1,5 Operating	 instruction

Condor

Condor R5/1,5 Operating instruction

Contrinex YRB-0330-242 operating instructions

Contrinex

Contrinex YRB-0330-242 operating instructions

Vimar Elvox 170A/101 instruction sheet

Vimar

Vimar Elvox 170A/101 instruction sheet

Stahl 9477/15 Series manual

Stahl

Stahl 9477/15 Series manual

Pilz P1HZ 2 operating instructions

Pilz

Pilz P1HZ 2 operating instructions

NIVELCO NITIME JEL-111 user manual

NIVELCO

NIVELCO NITIME JEL-111 user manual

Siemens Solkor 7PG2113 manual

Siemens

Siemens Solkor 7PG2113 manual

Omron G9SA - manual

Omron

Omron G9SA - manual

ABB ELR72P quick start guide

ABB

ABB ELR72P quick start guide

Basler BE1-47N instruction manual

Basler

Basler BE1-47N instruction manual

Moeller Xcomfort CSEZ-01/18 Assembly instructions

Moeller

Moeller Xcomfort CSEZ-01/18 Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.