Keithley 7036 User manual

WARRANTY
Keithley Instruments, Inc. warrants this product to be free from defects in material and workmanship for a period of 1 year from date of
shipment.
Keithley Instruments, Inc. warrants the following items for 90 days from the date of shipment: probes, cables, rechargeable batteries,
diskettes, and documentation.
During the warranty period, we will, at our option, either repair or replace any product that proves to be defective.
To exercise this warranty, write or call your local Keithley representative, or contact Keithley headquarters in Cleveland, Ohio. You will
be given prompt assistance and return instructions. Send the product, transportation prepaid, to the indicated service facility. Repairs
will be made and the product returned, transportation prepaid. Repaired or replaced products are warranted for the balance of the origi-
nal warranty period, or at least 90 days.
LIMITATION OF WARRANTY
This warranty does not apply to defects resulting from product modification without Keithley’s express written consent, or misuse of
any product or part. This warranty also does not apply to fuses, software, non-rechargeable batteries, damage from battery leakage, or
problems arising from normal wear or failure to follow instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. THE REMEDIES PROVIDED HEREIN ARE
BUYER’S SOLE AND EXCLUSIVE REMEDIES.
NEITHER KEITHLEY INSTRUMENTS, INC. NOR ANY OF ITS EMPLOYEES SHALL BE LIABLE FOR ANY DIRECT, INDI-
RECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF ITS INSTRUMENTS AND
SOFTWARE EVEN IF KEITHLEY INSTRUMENTS, INC., HAS BEEN ADVISED IN ADVANCE OF THE POSSIBILITY OF
SUCH DAMAGES. SUCH EXCLUDED DAMAGES SHALL INCLUDE, BUT ARE NOT LIMITED TO: COSTS OF REMOVAL
AND INSTALLATION, LOSSES SUSTAINED AS THE RESULT OF INJURY TO ANY PERSON, OR DAMAGE TO PROPERTY.
CHINA: Keithley Instruments China • Yuan Chen Xin Building, Room 705 • 12 Yumin Road, Dewai, Madian • Beijing 100029 • 8610-62022886 • Fax: 8610-62022892
FRANCE: Keithley Instruments SARL • BP 60 • 3 Allée des Garays • 91122 Palaiseau Cédex • 33-1-60-11-51-55 • Fax: 33-1-60-11-77-26
GERMANY: Keithley Instruments GmbH • Landsberger Strasse 65 • D-82110 Germering, Munich • 49-89-8493070 • Fax: 49-89-84930787
GREAT BRITAIN: Keithley Instruments, Ltd. • The Minster • 58 Portman Road • Reading, Berkshire RG30 1EA • 44-118-9575666 • Fax: 44-118-9596469
ITALY: Keithley Instruments SRL • Viale S. Gimignano 38 • 20146 Milano • 39-2-48303008 • Fax: 39-2-48302274
NETHERLANDS: Keithley Instruments BV • Avelingen West 49 • 4202 MS Gorinchem • 31-(0)183-635333 • Fax: 31-(0)183-630821
SWITZERLAND: Keithley Instruments SA • Kriesbachstrasse 4 • 8600 Dübendorf • 41-1-8219444 • Fax: 41-1-8203081
TAIWAN: Keithley Instruments Taiwan • 1FL., 1, Min Yu First Street • Hsinchu, Taiwan, R.O.C. • 886-35-778462 • Fax: 886-35-778455

Model 7036 40-Channel Single-Pole Relay Switch Card
Instruction Manual
©1997, Keithley Instruments, Inc.
All rights reserved.
Cleveland, Ohio, U.S.A.
First Printing, April 1997
Document Number: 7036-901-01 Rev. A

Manual Print History
The print history shown below lists the printing dates of all Revisions and Addenda created for this manual. The Revision
Level letter increases alphabetically as the manual undergoes subsequent updates. Addenda, which are released between Revi-
sions, contain important change information that the user should incorporate immediately into the manual. Addenda are num-
bered sequentially. When a new Revision is created, all Addenda associated with the previous Revision of the manual are
incorporated into the new Revision of the manual. Each new Revision includes a revised copy of this print history page.
Revision A (Document Number 7036-901-01)....................................................................................... April 1997
All Keithley product names are trademarks or registered trademarks of Keithley Instruments, Inc.
Other brand and product names are trademarks or registered trademarks of their respective holders.

Safety Precautions
The following safety precautions should be observed before using
this product and any associated instrumentation. Although some in-
struments and accessories would normally be used with non-haz-
ardous voltages, there are situations where hazardous conditions
may be present.
This product is intended for use by qualified personnel who recog-
nize shock hazards and are familiar with the safety precautions re-
quired to avoid possible injury. Read the operating information
carefully before using the product.
The types of product users are:
Responsible body
is the individual or group responsible for the use
and maintenance of equipment, and for ensuring that operators are
adequately trained.
Operators
use the product for its intended function. They must be
trained in electrical safety procedures and proper use of the instru-
ment. They must be protected from electric shock and contact with
hazardous live circuits.
Maintenance personnel
perform routine procedures on the product
to keep it operating, for example, setting the line voltage or replac-
ing consumable materials. Maintenance procedures are described in
the manual. The procedures explicitly state if the operator may per-
form them. Otherwise, they should be performed only by service
personnel.
Service personnel
are trained to work on live circuits, and perform
safe installations and repairs of products. Only properly trained ser-
vice personnel may perform installation and service procedures.
Exercise extreme caution when a shock hazard is present. Lethal
voltage may be present on cable connector jacks or test fixtures.The
American National Standards Institute (ANSI) states that a shock
hazard exists when voltage levels greater than 30V RMS, 42.4V
peak, or 60VDC are present.
A good safety practice is to ex-
pect that hazardous voltage is present in any un-
known circuit before measuring.
Users of this product must be protected from electric shock at all
times. The responsible body must ensure that users are prevented
access and/or insulated from every connection point. In some cases,
connections must be exposed to potential human contact. Product
users in these circumstances must be trained to protect themselves
from the risk of electric shock. If the circuit is capable of operating
at or above 1000 volts,
no conductive part of the circuit may be
exposed.
As described in the International Electrotechnical Commission
(IEC) Standard IEC 664, digital multimeter measuring circuits
(e.g., Keithley Models 175A, 199, 2000, 2001, 2002, and 2010)
measuring circuits are Installation Category II. All other instru-
ments’ signal terminals are Installation Category I and must not be
connected to mains.
Do not connect switching cards directly to unlimited power circuits.
They are intended to be used with impedance limited sources.
NEVER connect switching cards directly to AC mains. When con-
necting sources to switching cards, install protective devices to lim-
it fault current and voltage to the card.
Before operating an instrument, make sure the line cord is connect-
ed to a properly grounded power receptacle. Inspect the connecting
cables, test leads, and jumpers for possible wear, cracks, or breaks
before each use.
For maximum safety, do not touch the product, test cables, or any
other instruments while power is applied to the circuit under test.
ALWAYS remove power from the entire test system and discharge
any capacitors before: connecting or disconnecting cables or jump-
ers, installing or removing switching cards, or making internal
changes, such as installing or removing jumpers.
Do not touch any object that could provide a current path to the
common side of the circuit under test or power line (earth) ground.
Always make measurements with dry hands while standing on a
dry, insulated surface capable of withstanding the voltage being
measured.

Do not exceed the maximum signal levels of the instruments and ac-
cessories, as defined in the specifications and operating informa-
tion, and as shown on the instrument or test fixture panels, or
switching card.
When fuses are used in a product, replace with same type and rating
for continued protection against fire hazard
Chassis connections must only be used as shield connections for
measuring circuits, NOT as safety earth ground connections.
If you are using a test fixture, keep the lid closed while power is ap-
plied to the device under test. Safe operation requires the use of a
lid interlock.
If a screw is present, connect it to safety earth ground using the
wire recommended in the user documentation.
The symbol on an instrument indicates that the user should re-
fer to the operating instructions located in the manual.
The symbol on an instrument shows that it can source or mea-
sure 1000 volts or more, including the combined effect of normal
and common mode voltages. Use standard safety precautions to
avoid personal contact with these voltages.
The
WARNING
heading in a manual explains dangers that might
result in personal injury or death. Always read the associated infor-
mation very carefully before performing the indicated procedure.
The
CAUTION
heading in a manual explains hazards that could
damage the instrument. Such damage may invalidate the warranty.
Instrumentation and accessories shall not be connected to humans.
Before performing any maintenance, disconnect the line cord and
all test cables.
To maintain protection from electric shock and fire, replacement
components in mains circuits, including the power transformer, test
leads, and input jacks, must be purchased from Keithley Instru-
ments. Standard fuses, with applicable national safety approvals,
may be used if the rating and type are the same. Other components
that are not safety related may be purchased from other suppliers as
long as they are equivalent to the original component. (Note that se-
lected parts should be purchased only through Keithley Instruments
to maintain accuracy and functionality of the product.) If you are
unsure about the applicability of a replacement component, call a
Keithley Instruments office for information
To clean the instrument, use a damp cloth or mild, water based
cleaner. Clean the exterior of the instrument only. Do not apply
cleaner directly to the instrument or allow liquids to enter or spill
on the instrument.
!

MODEL 7036 SPECIFICATIONS
RELAY SWITCH CONFIGURATION: 40 independent channels of
1-pole switching.
CONTACT CONFIGURATION: 1 pole Form A.
CONNECTOR TYPE: 96-pin male DIN card connector.
MAXIMUM SIGNAL LEVEL: 60VDC, 30V rms, 42V peak betwen any
two inputs or chassis, 1A switched. 30VA (resistive load).
CONTACT LIFE:
Cold Switching: 108closures.
At Maximum Signal Levels: 105closures.
CHANNEL RESISTANCE (per conductor): <1Ω.
CONTACT POTENTIAL: <4µV per contact.
OFFSET CURRENT: <100pA.
ACTUATION TIME: 3ms.
ISOLATION:
Channel to Channel: >109Ω, <25pF.
Common Mode: >109Ω, <100pF.
CROSSTALK (1MHz, 50ΩLoad): <–40dB.
INSERTION LOSS (50ΩSource, 50ΩLoad): <0.3dB below 1MHz,
<3dB below 10MHz.
RELAY DRIVE CURRENT (per relay): 16mA.
EMC: Conforms with European Union Directive 89/336/EEC
EN 55011, EN 50082-1, EN 61000-3-2 and 61000-3-3, FCC part 15
class B.
SAFETY: Conforms with European Union Directive 73/23/EEC
EN 61010-1, UL 3111-1.
ENVIRONMENT: Operating: 0° to 50°C, up to 35°C at <80% R.H.
Storage: –25°C to 65°C.
Specifications are subject to change without notice.
IN
Each Channel
OUT

Table of Contents
1 General Information
Introduction.......................................................................................................................................................... 1-1
Features ............................................................................................................................................................... 1-1
Warranty information.......................................................................................................................................... 1-1
Manual addenda .................................................................................................................................................. 1-2
Safety symbols and terms ................................................................................................................................... 1-2
Specifications ...................................................................................................................................................... 1-2
Unpacking and inspection................................................................................................................................... 1-2
Inspection for damage................................................................................................................................. 1-2
Shipping contents........................................................................................................................................ 1-2
Instruction manual....................................................................................................................................... 1-3
Repacking for shipment ...................................................................................................................................... 1-3
Optional accessories............................................................................................................................................ 1-3
2 Relay Switching Basics
Introduction......................................................................................................................................................... 2-1
Basic switch configuration (SPST) ..................................................................................................................... 2-1
3 Card Connections and Installation
Introduction......................................................................................................................................................... 3-1
Handling precautions .......................................................................................................................................... 3-1
Multi-pin (mass termination) connections .......................................................................................................... 3-2
Typical connection technique ..................................................................................................................... 3-4
Typical connection scheme......................................................................................................................... 3-6
Model 7036 installation and removal.................................................................................................................. 3-7
Switch card installation............................................................................................................................... 3-7
Switch card removal.................................................................................................................................... 3-7
i

4 Operation
Introduction ......................................................................................................................................................... 4-1
Power limits......................................................................................................................................................... 4-1
Maximum signal levels................................................................................................................................ 4-1
Reactive loads.............................................................................................................................................. 4-1
Mainframe control of relay card.......................................................................................................................... 4-2
Channel assignments ................................................................................................................................... 4-3
Front panel control ...................................................................................................................................... 4-5
IEEE-488 bus operation .............................................................................................................................. 4-6
Measurement considerations ............................................................................................................................... 4-7
Path isolation ............................................................................................................................................... 4-7
Magnetic fields ............................................................................................................................................ 4-7
Radio frequency interference ...................................................................................................................... 4-8
Ground loops ............................................................................................................................................... 4-8
Keeping connectors clean............................................................................................................................ 4-9
AC frequency response................................................................................................................................ 4-9
5 Service Information
Introduction ......................................................................................................................................................... 5-1
Handling and cleaning precautions ..................................................................................................................... 5-1
Performance verification ..................................................................................................................................... 5-2
Environmental conditions............................................................................................................................ 5-2
Recommended equipment ........................................................................................................................... 5-2
Switch card connections .............................................................................................................................. 5-2
Channel resistance tests............................................................................................................................... 5-3
Offset current tests....................................................................................................................................... 5-4
Contact potential tests.................................................................................................................................. 5-5
Channel to channel isolation tests ............................................................................................................... 5-5
Common-mode isolation tests ..................................................................................................................... 5-8
Special handling of static-sensitive devices ........................................................................................................ 5-9
Principles of operation......................................................................................................................................... 5-9
Block diagram ............................................................................................................................................. 5-9
ID data circuits .......................................................................................................................................... 5-10
Relay control ............................................................................................................................................. 5-10
Relay power control .................................................................................................................................. 5-10
Power-on safeguard ................................................................................................................................... 5-11
Troubleshooting................................................................................................................................................. 5-11
Troubleshooting equipment....................................................................................................................... 5-11
Troubleshooting access ............................................................................................................................. 5-11
Troubleshooting procedure........................................................................................................................ 5-12
6 Replaceable Parts
Introduction ......................................................................................................................................................... 6-1
Parts lists...............................................................................................................................................................6-1
Ordering information........................................................................................................................................... 6-1
Factory service..................................................................................................................................................... 6-1
Component layouts and schematic diagrams ...................................................................................................... 6-2
Index
ii

List of Illustrations
2 Relay Switching Basics
Figure 2-1 Model 7036 40-channel switch card (simplified schematic) ...................................................................... 2-1
3 Card Connections and Installation
Figure 3-1 Multi-pin connector card terminal identification ........................................................................................ 3-2
Figure 3-2 Typical cable connection technique............................................................................................................ 3-5
Figure 3-3 Model 7011-KIT-R (cable) assembly ......................................................................................................... 3-5
Figure 3-4 Typical connection scheme for Model 7036............................................................................................... 3-6
Figure 3-5 Model 7036 card installation in Model 7001 .............................................................................................. 3-7
4 Operation
Figure 4-1 Limiting inductive reaction voltage ............................................................................................................ 4-2
Figure 4-2 Limiting capacitive reaction current ........................................................................................................... 4-2
Figure 4-3 Model 7001 channel status display (two cards installed)............................................................................ 4-3
Figure 4-4 Model 7002 channel status display (slot 1)................................................................................................. 4-3
Figure 4-5 Display organization for relay card channels.............................................................................................. 4-4
Figure 4-6 Channel assignments................................................................................................................................... 4-4
Figure 4-7 Path isolation resistance .............................................................................................................................. 4-7
Figure 4-8 Voltage attenuation by path isolation resistance......................................................................................... 4-7
Figure 4-9 Power line ground loops ............................................................................................................................. 4-8
Figure 4-10 Eliminating ground loops............................................................................................................................ 4-8
5 Service Information
Figure 5-1 Channel resistance testing........................................................................................................................... 5-3
Figure 5-2 Offset current testing................................................................................................................................... 5-4
Figure 5-3 Contact potential testing.............................................................................................................................. 5-5
Figure 5-4 Channel to channel testing .......................................................................................................................... 5-6
Figure 5-5 Common-mode isolation testing ................................................................................................................. 5-8
Figure 5-6 Model 7036 block diagram ......................................................................................................................... 5-9
Figure 5-7 Start and stop sequences ........................................................................................................................... 5-10
Figure 5-8 Transmit and acknowledge sequence........................................................................................................ 5-10
iii

List of Tables
3 Card Connections and Installation
Table 3-1 Multi-pin connector card terminal designation cross-reference.................................................................. 3-3
Table 3-2 Mass termination accessories...................................................................................................................... 3-4
5 Service Information
Table 5-1 Verification equipment ............................................................................................................................... 5-2
Table 5-2 Channel to channel isolation tests............................................................................................................... 5-7
Table 5-3 Recommended troubleshooting equipment............................................................................................... 5-11
Table 5-4 Troubleshooting procedure ....................................................................................................................... 5-12
6 Replaceable Parts
Table 6-1 Relay card for Model 7036, parts list.......................................................................................................... 6-3
Table 6-2 Mass-terminated connector card for Model 7036, parts list ....................................................................... 6-5
Table 6-3 Model 7011-KIT-R 96-pin Female DIN connector kit................................................................................6-7
v

1
General Information
1-1
Introduction
This section contains general information about the Model
7036 40-Channel Single-Pole Relay Switch Card.
The Model 7036 switch card consists of a multi-pin (mass
termination) connector card and a relay card. External test
circuit connections to the Model 7036 are made via the 96-
pin male DIN connector on the connector card. Keithley
offers an optional Model 7011-MTR bulkhead connector
that can be used to make connections to the connector card.
(See the optional accessories paragraph at the end of this
section.)
The rest of Section 1 is arranged in the following manner:
• Features
• Warranty information
• Manual addenda
• Safety symbols and terms
• Specifications
• Unpacking and inspection
• Repacking for shipment
• Optional accessories
Features
The Model 7036 is a general purpose switch card with 40
independent channels for greater programming fl xibility.
Some of the key features include:
• Low contact potential and offset current for minimal
effects on low-level signals.
• High isolation resistance >1G
Ω
for minimal load
effects.
• Model 7011-KIT-R connector kit that includes a 96-pin
female DIN connector that will mate directly to the con-
nector on the Model 7036 or to a standard 96-pin male
DIN bulkhead connector (see Model 7011-MTR). This
connector uses solder cups for connections to external
circuitry and includes an adapter for a round cable and
the housing.
Warranty information
Warranty information is located on the inside front cover of
this instruction manual. Should your Model 7036 require
warranty service, contact the Keithley representative or
authorized repair facility in your area for further informa-
tion. When returning the card for repair, be sure to fill out and
include the service form at the back of this manual in order
to provide the repair facility with the necessary information.

General Information
1-2
Manual addenda
Any improvements or changes concerning the switch card or
manual will be explained in an addendum included with the
card. Addenda are provided in a page-replacement format.
Replace the obsolete pages with the new pages.
Safety symbols and terms
The following symbols and terms may be found on an instru-
ment or used in this manual.
The symbol on an instrument indicates that the user
should refer to the operating instructions located in the
instruction manual.
The symbol on an instrument shows that high voltage
may be present on the terminal(s). Use standard safety pre-
cautions to avoid personal contact with these voltages.
The
WARNING
heading used in this manual explains dan-
gers that might result in personal injury or death. Always
read the associated information very carefully before per-
forming the indicated procedure.
The
CAUTION
heading used in this manual explains haz-
ards that could damage the switch card. Such damage may
invalidate the warranty.
Specifications
Model 7036 specifications may be found at the front of this
manual. These specifications are exclusive of the
Model 7001/7002 mainframe specifications
Unpacking and inspection
Inspection for damage
The Model 7036 is packaged in a resealable, anti-static bag
to protect it from damage due to static discharge and from
contamination that could degrade its performance. Before
removing the card from the bag, observe the following han-
dling precautions.
Handling pr ecautions
1. Always grasp the card by the side edges and shields. Do
not touch the board surfaces or components.
2. When not installed in a Model 7001/7002 mainframe,
keep the card in the anti-static bag and store it in the
original packing carton.
After removing the card from its anti-static bag, inspect it for
any obvious signs of physical damage. Report any such dam-
age to the shipping agent immediately.
Shipping contents
The following items are included with every Model 7036
order:
• Model 7036 40-Channel Single-Pole Relay Switch
Card
• Model 7036 Instruction Manual
• Model 7011-KIT-R 96-pin Female DIN Connector Kit
• Additional accessories as ordered
!

General Information
1-3
Instruction manual
The Model 7036 Instruction Manual is three-hole drilled so
that it can be added to the three-ring binder of the Model
7001 or Model 7002 Instruction Manual. After removing the
plastic wrapping, place the manual in the binder following
the mainframe instruction manual. Note that a manual iden-
tification tab is included and should precede the switch card
instruction manual.
If an additional instruction manual is required, order the
manual package, Keithley part number 7036-901-00. The
manual package includes an instruction manual and any per-
tinent addenda.
Repacking for shipment
Should it become necessary to return the Model 7036 for
repair, carefully pack the unit in its original packing carton,
or the equivalent, and include the following information:
• Advise as to the warranty status of the switch card.
• Write ATTENTION REPAIR DEPARTMENT on the
shipping label.
• Fill out and include the service form located at the back
of this manual.
Optional accessories
The following accessory is available for use with the Model
7036:
Model 7011-MTR
This 96-pin male DIN bulkhead
connector uses solder cups for connections to external cir-
cuitry. It will mate to the Model 7011-KIT-R connector.

2
Relay Switching Basics
2
-
1
Introduction
This section covers the basic single-pole, single-throw
(SPST) switch configuration
Basic switch configuration (SPST)
A simplified schematic of the Model 7036 switch card is
shown in Figure 2-1. The card consists of 40 independent
channels. Each channel is made up of a single-pole, single-
throw (SPST), normally open (NO) switch.
Figure 2-1
Model 7036 40-channel switch card (simplified s hematic)
IN 1
OUT 1
One of 40 Channels

3
Card Connections and Installation
3-1
Introduction
WARNING
The procedures in this section are
intended only for qualified ser-
vice personnel. Do not perform
these procedures unless qualifie
to do so. Failure to recognize and
observe normal safety precau-
tions could result in personal
injury or death.
The information in this section is arranged as follows:
•
Handling precautions
Explains precautions
that must be followed to prevent contamination to the
switch card. Contamination could degrade the perfor-
mance of the card.
•
Multi-pin (mass termination) connections
Covers the basics for connecting external circuitry to
the connector card.
•
Model 7036 installation and removal
Pro-
vides the procedures to install and remove the Model
7036 switch card from the Model 7001/7002 main-
frame.
Handling precautions
To maintain high impedance isolation, care should be taken
when handling the card to avoid contamination from such for-
eign materials as body oils. Such contamination can substan-
tially lower leakage resistances and degrade performance.
To avoid possible contamination, always grasp the relay card
and the connector card by the side edges or shields. Do not
touch the board surfaces or components. On connectors, do
not touch areas adjacent to the electrical contacts. Dirt
buildup over a period of time is another possible source of
contamination. To avoid this problem, operate the mainframe
and switch card in a clean environment.

Card Connections and Installation
3-2
If a card becomes contaminated, it should be thoroughly
cleaned as explained in Section 5.
WARNING
The following connection infor-
mation is intended to be used by
qualified service personnel. Fail-
ure to recognize and observe
standard safety precautions
could result in personal injury or
death.
Multi-pin (mass termination)
connections
Since connections to external circuitry are made at the 96-pin
male DIN bulkhead connector, there is no need to separate
the connector card from the relay card. If the connector card
is separated from the relay card, carefully mate them
together and install the supplied 4-40 screw to secure the
cards. Make sure to handle the cards by the edges and shields
to avoid contamination.
Terminal identification for the DIN connector of the multi-
pin connector card is provided by Figure 3-1 and Table 3-1.
This connector will mate to a 96-pin female DIN connector.
Figure 3-1
Multi-pin connector card terminal identificatio
View pin side
of connector
3231302928272625242322212019181716151413121110987654321
a
b
c

Card Connections and Installation
3-3
Table 3-1
Multi-pin connector card terminal designation cross-reference
Switch
terminal
Connector
designator
1a-32c
Schemati
c
designato
r
1-96
Switch
terminal
Connector
designator
1a-32c
Schematic
designato
r
1-96
Switch
terminal
Connecto
r
designato
r
1a-32c
Schemati
c
designato
r
1-96
IN 1 13a 13 IN 17 24a 24 IN 33 12c 76
OUT 1 14a 14 OUT 17 23a 23 OUT 33 11c 75
IN 2 15a 15 IN 18 26a 26 IN 34 4c 68
OUT 2 16a 16 OUT 18 25a 25 OUT 34 3c 67
IN 3 6a 6 IN 19 28a 28 IN 35 28c 92
OUT 3 7a 7 OUT 19 7b 39 OUT 35 6c 70
IN 4 12a 12 IN 20 17a 17 IN 36 9c 73
OUT 4 11a 11 OUT 20 31c 95 OUT 36 10c 74
IN 5 2a 2 IN 21 23b 55 IN 37 2c 66
OUT 5 3a 3 OUT 21 24b 56 OUT 37 1c 65
IN 6 4a 4 IN 22 25b 57 IN 38 14c 78
OUT 6 5a 5 OUT 22 26b 58 OUT 38 13c 77
IN 7 21a 21 IN 23 17b 49 IN 39 16c 80
OUT 7 18a 18 OUT 23 18b 50 OUT 39 26c 90
IN 8 8a 8 IN 24 19b 51 IN 40 20c 84
OUT 8 10a 10 OUT 24 20b 52 OUT 40 30c 94
IN 9 4b 36 IN 25 13b 45 chassis 9a 9
OUT 9 5b 37 OUT 25 14b 46 chassis 9b 41
IN 10 12b 44 IN 26 15b 47 nc 22a 22
OUT 10 11b 43 OUT 26 16b 48 nc 27a 27
IN 11 30a 30 IN 27 27b 59 nc 29a 29
OUT 11 32c 96 OUT 27 28b 60 nc 32a 32
IN 12 20a 20 IN 28 29b 61 nc 6b 38
OUT 12 19a 19 OUT 28 30b 62 nc 8b 40
IN 13 3b 35 IN 29 21c 85 nc 5c 69
OUT 13 2b 34 OUT 29 22c 86 nc 7c 71
IN 14 21b 53 IN 30 23c 87 nc 15c 79
OUT 14 22b 54 OUT 30 24c 88 nc 17c 81
IN 15 10b 42 IN 31 18c 82 nc 19 83
OUT 15 31a 31 OUT 31 8c 72 nc 25c 89
IN 16 1a 1 IN 32 32b 64 nc 27c 91
OUT 16 1b 33 OUT 32 31b 63 nc 29c 93

Card Connections and Installation
3-4
Keithley has a variety of cable and connector accessories
available to accommodate connections from the connector
card to test instrumentation and DUTs (devices under test).
In general, these accessories, which are summarized in
Table 3-2, utilize a custom-built cable assembly for
connections.
Typical connection technique
All external circuitry, such as instrumentation and DUTs,
that you want to connect to the switch card must be termi-
nated with a single 96-pin female DIN connector. The fol-
lowing connection techniques provide some guidelines and
suggestions for wiring your circuitry.
WARNING
Before beginning any wiring pro-
cedures, make sure all power is
off and stored energy in external
circuitry is discharged.
WARNING
When wiring a connector, do not
leave any exposed wires. No con-
ductive part of the circuit may be
exposed. Properly cover the con-
ductive parts, or death by elec-
tric shock may occur.
CAUTION
The 7011-MTC-2 cable is not
intended to be used with the
Model 7036. Pins 1 and 33 in the
cable are internally shorted, but
the Model 7036 uses these pins
for signaling. Using the 7011-
MTC-2 cable with the Model 7036
will short out the system and
cause equipment damage.
NOTE
It is recommended that external cir-
cuitry be connected (plugged in) after
the Model 7036 is installed in the Model
7001/7002 mainframe. Installation is
covered at the end of this section.
In Figure 3-2, connections are accomplished using a custom-
built cable assembly that consists of a Model 7011-KIT-R
connector and a suitable round cable. Hitachi part number
N2807-P/D-50TAB is a round, 50-conductor cable. Two
cables can be used to provide 100 conductors. The connector
has solder cups to accommodate the individual wires of the
unterminated cable. Figure 3-3 provides an exploded view of
the connector assembly and shows how the cable is con-
nected. For further Model 7011-KIT-R assembly informa-
tion, refer to the packing list provided with the kit. The
connector end of the resultant cable assembly mates directly
to the multi-pin connector card. The unterminated end of the
cable assembly is wired directly to instrumentation and
DUT.
Table 3-2
Mass termination accessories
Model Description
7011-KIT-R 96-pin female DIN connector and
housing for round cable (provided
with the Model 7036 card).
7011-MTR 96-pin male DIN bulkhead connector.

Card Connections and Installation
3-5
Figure 3-2
Typical cable connection technique
Figure 3-3
Model 7011-KIT-R (cable) assembly
Notes : Figure 3-3 provides an exploded view showing
how the connector (with cable) is assembled.
Multi-Pin
Connector
Card
Cable
Wire directly to
instrumentation
and DUT
7011-Kit-R
Connector Kit
Cable Hitachi p/n N2807-P/D-50TAB is a
50-conductor round cable. Two of these
cables can be used to supply 100 conductors.
Table of contents
Other Keithley Relay manuals
Popular Relay manuals by other brands

Schweitzer Engineering Laboratories
Schweitzer Engineering Laboratories SEL-487B-2 manual

MULTISPAN
MULTISPAN MI-632 Installation guidelines

Allen-Bradley
Allen-Bradley 140G Series quick start guide

hager
hager EU301 User instructions

gefran
gefran GTS quick start guide

Siemens
Siemens SIRIUS 3RU5 36 B Series operating instructions

F&F
F&F PP-2Z quick start guide

Honeywell
Honeywell SeqLED E SET-30 quick start guide

Zamel
Zamel Exta PBM-07 Manual instruction

Rockwell Automation
Rockwell Automation Allen-Bradley 193 Installation instruction sheet

Emerson
Emerson White Rogers SureSwitch 49P11-843 installation instructions

frako
frako RM 9606 operating instructions