4 Notice for installation Kelvinator Air Conditioning
Safety Precautions for Electric Appliances
1A dedicated power supply circuit should be used for
products not supplied with a service cord and plug in
accordance with local electrical safety regulations.
3The unit must be reliably earthed and connected to
the special earth device by the qualified electrician.
4The circuit breaker must have the functions of magnetic
tripping and heat tripping to prevent short circuit
and overload.
5The appliance shall be installed in accordance with
6Including an circuit breaker with suitable capacity, please
note the following table.
Model
Note:
• Make sure the live wire, neutral wire and earth wire in
the power socket are properly connected.
• Inadequate or incorrect electrical connections may cause
electric shock or fire.
Earthing Requirements
1Air conditioner is type I electric appliance. Please ensure
the unit is reliably earthed.
2 The yellow-green wire in air conditioner is the earthing
wire which can not be used for other purposes. Improper
earthing may cause electric shock.
3The earth resistance should accord to the national
wiring regulation.
4The user's power must have reliable earthing terminal.
Do not connect the earthing wire with the following:
1. Water pipe
2. Gas pipe
3. Contamination pipe
Installation Site Instructions
A proper installation site is vital for correct and efficient
operation of the unit. Avoid the following sites where:
• strong heat sources, vapours, ammable gas or volatile
liquids are emitted.
• high-frequency electro-magnetic waves are generated
by radio equipment, welders or medical equipment.
• salt-laden air prevails (such as close to coastal areas).
• the air is contaminated with industrial vapours and oils.
• the air contains sulphurous gas such as in hot spring
zones.
• corrosion or poor air quality exists.
Installation Site of Indoor Unit
1 The air inlet and outlet should be away from the
obstructions. Ensure the air can be blown through the
whole room.
2 Select a site where the condensing water can be
easily drained out, and where it is easily connected for
the outdoor unit.
3 Select a place where it is out of reach of children.
4 Select the place where the wall is strong enough to
withstand the full weight and vibration of the unit.
5 Be sure to leave enough space to allow access for routine
above the oor.
6
7 Select a place where the filter can be easily taken out.
8 Make sure that the indoor unit is installed in accordance
with installation dimension instructions (refer to page 5).
9 Do not use the unit in the laundry or by swimming
pool etc.
Installation Site of Outdoor Unit
1 Select a site where noise and outow air emitted by unit
will not annoy neighbors.
2 Select a site where there is sufficient ventilation.
3 Select a site where there is no obstruction blocking the
inlet and outlet.
4 The site should be able to withstand the full weight
and vibration of the unit.
5 Select a dry place, but do not expose the unit to direct
sunlight or strong wind.
6 Make sure that the outdoor unit is installed in accordance
with the installation instructions, and is convenient for
maintenance and repair.
7 The height difference between indoor and outdoor units
complies with the table on page 8.
8 Select a place where it is out of reach of children.
16
16
25
maintenance. The installation site should be 2m or more
Select a place about 1m or more away from a TV set or
national wiring regulations.
Circuit Breaker (Amps)
10
10
25
32
32
32
KSE26CRC
KSE26HRC
KSE35CRC
KSE35HRC
KSE53HRC
KSE62HRC
KSE70CRC
KSE70HRC
32
KSE88HRC
KSE88CRC
any other electric appliance.