Component Specifications
IWARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Component
Compressor run capacitor
Compressor
Electric damper control
Thermistor
Condenser motor
Evaporator fan motor
Overload/Relay
Thermostat (Defrost)
Evaporator heater
22 & 26 cu. ft
Evaporator heater
23 cu. ft
Control board
Auger Motor
Water Valve
Super CooI Fan
Light switch /Interlock
Solenoid (Ice Chute)
Specifications all parts
115VAC/60HZ unless noted
Volt ..................................................... 220 VAC
Capacitance ...................................... 15 __dd+ 10%
BTUH ................................................. 905 BTUH
Watt ................................................... 60 Hz /153 watts
Current Lock rotor .............................. 19.0 amps_+ 15%
Current Full load ................................ 1.26 amps_+ 15%
Resistance Run windings ................... 3.33 ohms_+ 15%
Resistance Start windings .................. 4.28 ohms_+ 15%
Maximum closing time 36 seconds
Temperature Rating 20°F- 110°F
RPM 1
Temperature Resistance
77°F .................................................... 10,000 ohms_+ 1.8%
36°F ................................................... 29,500 ohms_+ 1.0%
0°F ...................................................... 86,300 ohms_+ 1.8%
Rotation (facing end opposite shaft) Clockwise
RPM 1120 RPM
Watt .................................................... 3.4 watts _+15%@ 115VAC
Current ............................................... 0.085 amps_+ 15%@ 115VAC
Rotation (facing end opposite shaft) Clockwise
RPM .......................................... 2800 RPM
Watt ........................................... 6.0 -+15% watts@l!5 VAC
Note: Fan blade must be fully seated
on shaft to achieve proper airflow.
UIt. trip amps @ 158°F (70°C) ........... 2.67 amps-+ 15%
Close temperature ........................... 142°F +9°
Open temperature ............................ 284°F +9°
Short time trip (seconds) .................... 10 seconds _+5
Short time trip (amps @77°F (25°C).. 11 amps _+2amps
Volt .................................................... 120/240 VAC
Watt ................................................... 495 watts
Current ............................................... 5.8/2.9 amps
Resistance across terminals:
Above 42°F +5° .................................. Open
Below 12 °F +7° .................................. Closed
Volt ..................................................... 115 VAC
Wattage ............................................. 450 _+5%watts @ 115VAC
Resistance ......................................... 29 _+5% ohms
Volt ..................................................... 115 VAC
Wattage ............................................. 350 -+5% watts @ 115VAC
Resistance ......................................... 37.8 _+5%ohms
Volt ..................................................... 120VAC, 60 HZ
See Control board troubleshooting section
Rotation (facing end opposite shaft) Power to blue and white is clockwise. Power to orange and white is
counterclockwise
RPM ................................................... 17+ 3 RPM
Watts .................................................. Brown side 35w,YelIow side 20w
Rotation (facing end opposite leads) Counterclockwise
RPM .......................................... 1530 + 250
Watt .......................................... 1.2 @ 12 VDC
Type ............................................ SPDT NO/NC
Volt ............................................. 125/250 VAC
Current ......................................... 8/4 amps
Resistance across leads .................... 1Olohms + 10%
Service Specifications
I WARNING ]
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.
Programming Mode:
NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.
.
.
3.
4.
.
.
Open the Fresh Food door and press and hold the Door Alarm Keypad
Press and hold Freezer Temperature Down Keypad(_-I_.
Release the Door Alarm Keypad and wait 3 seconds.
The control will display PE to indicate the programming mode.
I Freezer O O r_<c_r _<Z_pl_ce O @ O O Refrigerator
Entry is confirmed by pressing the Freezer Temperature Down Keypad _ once more.
The control will display the current Program CODE. This value should be validated with the Program CODE printed on
the unit serial plate.
(_ Freezer o o_r _p_ace o ® o o Refrigerator
NOTE: If the Program CODE is correct, the Programming Mode is exited by closing the Refrigerator door(s).
7. Press the Refrigerator Temperature UP Keypad _ or Refrigerator Down Keypad ([_) to change the digit value
with each key press.
8. The decimal point indicates the selected digit. Press the Freezer Temperature UP Keypad (_ to select the next
digit.
9. Once the desired Program CODE is displayed, press and hold the Freezer Temperature DOWN Keypad (_ until the
Program CODE begins flashing indicating it has been saved.
NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will
NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is
exited by closing the Refrigerator door(s). If the new code is incorrect this process should be repeated after closing
the Refrigerator door(s).
The Programming mode can be exited at any time by closing the Refrigerator Door(s) or will exit if unattended for
four minutes.
Defrost Operation:
The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by
monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours compressor run
time. Defrost occurs immediately after the 4 hours.
December 2004 2 12893007 December 2004 3 12893007